- Learn
- Engineering
- Mechanical & Civil Engineering
- Materials Science and Engineering
- Corrosion and Materials Selection
Corrosion and Materials Selection
IntermediateLesson 9 of 9 in Materials Science and Engineering Course
What you will learn
- Describe the corrosion of metals as linked oxidation and reduction reactions, predict which metal corrodes from electrode potentials, calculate corrosion rates and explain how metals oxidize in hot, dry gases.
- Describe the corrosion cell and its half-reactionsWrite the anodic and cathodic half-reactions for a metal in water and name the four parts every wet corrosion cell needs.
- Predict which metal corrodes using electrode potentialsUse the standard emf series, the Nernst equation and the galvanic series to decide which metal in a couple is oxidized and how strong the driving force is.
- Calculate corrosion rates and explain polarization and passivityExpress corrosion rates as penetration rate or current density, convert between them with Faraday's law, and use polarization and passivity to explain why real rates differ from what potentials suggest.
- Explain oxidation of metals at high temperatureDescribe dry oxidation in hot gases, judge whether an oxide scale protects the metal with the Pilling–Bedworth ratio, and apply linear, parabolic and logarithmic growth laws.
- Describe the corrosion cell and its half-reactions
- Recognize each form of corrosion from its appearance and conditions, explain why it happens, and prevent it through material choice, the environment, design, coatings and cathodic protection.
- Recognize uniform, galvanic, crevice and pitting corrosionIdentify these forms from their appearance and conditions, explain their mechanisms and name the changes that control them.
- Recognize intergranular attack, selective leaching, erosion–corrosion, stress corrosion and hydrogen embrittlementExplain the mechanism, typical alloys and conditions of the forms that act along grain boundaries, on one element of an alloy, under fluid flow or under stress, and how each is controlled.
- Prevent corrosion through material choice, environment control and designChoose materials that suit the environment, change the environment with inhibitors and other measures, and design details that keep water out and avoid harmful metal couples.
- Protect metals with coatings and cathodic protectionExplain how barrier, sacrificial and noble coatings work, and how sacrificial-anode and impressed-current cathodic protection keep a structure from corroding.
- Recognize uniform, galvanic, crevice and pitting corrosion
- Explain the physical and chemical ways in which polymers and ceramics deteriorate in service, and choose materials and additives that slow this deterioration.
- Explain swelling, dissolution and environmental stress cracking of polymersExplain how liquids enter and weaken polymers, predict which polymer–liquid pairs are risky, and recognize environmental stress cracking.
- Explain bond rupture, weathering and the degradation of ceramicsExplain how radiation, chemical attack and heat break polymer chains, how weathering is slowed with stabilizers, and how ceramics and glasses are attacked.
- Explain swelling, dissolution and environmental stress cracking of polymers
- Translate design requirements into constraints and an objective, derive material performance indices, and use Ashby property charts to screen and rank candidate materials.
- Translate a design into function, constraints, objective and free variablesTurn a design brief into the statements that drive materials selection, then screen candidates with limits before ranking them.
- Derive performance indices for ties, beams, panels and shaftsWrite the objective as an equation, eliminate the free variable with the constraint, and read off the performance index to maximize.
- Use Ashby property charts to screen and rank materialsRead logarithmic property charts, draw selection lines for a performance index, and combine limits and indices to arrive at a short list.
- Translate a design into function, constraints, objective and free variables
- Compare materials by cost per function and over a product's whole life, judge the environmental burden across the materials cycle, and design products whose materials can be recovered.
- Compare materials by cost per unit of functionUse cost-based performance indices and component cost estimates to compare materials that do the same job.
- Estimate life-cycle cost, including the cost of corrosionAdd up the costs of a design over its whole service life, discount future costs, and use the result to judge corrosion-resistant choices.
- Judge environmental impact across the materials cycleFollow a material from extraction to end of life, compare embodied energy, and find the life phase that dominates a product's environmental burden.
- Design for recycling and explain how each material class is recycledExplain how metals, glass, thermoplastics, thermosets, elastomers and composites are recovered, what limits recycling, and how design choices make it easier.
- Compare materials by cost per unit of function
Corrosion and Materials Selection study guide
1Explain corrosion as an electrochemical process
Corrosion links chemistry to the loss of useful metal. Half-reactions show where atoms dissolve and where electrons are consumed; potentials show the driving force. Rate calculations then connect mass or charge to thickness loss, while polarization and passive films explain why voltage alone cannot predict service life. In hot gases, oxide scales create a different transport barrier whose growth can slow or continue at a steady rate.
1.1 Follow the reactions in a corrosion cell
A metal can lose atoms while looking like a single, continuous piece. Different areas of its surface carry out different reactions. To explain the damage, follow both the electrons in the metal and the ions in the water.
Connect oxidation and reduction
At the anode, metal atoms lose electrons and enter solution:
At the cathode, a reduction reaction consumes those electrons. In acid, hydrogen ions can be reduced: . In neutral or basic aerated water, oxygen is usually reduced: . In acid, oxygen reduction instead uses hydrogen ions: . Dissolved metal ions can also accept electrons, for example .
The anode and cathode reactions must transfer equal numbers of electrons. If the cathodic reaction slows, the connected anodic reaction must also slow. Oxygen is therefore important in many water systems, but it is not essential to every corrosion reaction: acid can support hydrogen evolution without it.
Trace the four parts
A wet corrosion cell needs an anode, a cathode, an electron-conducting metallic path, and an ion-conducting electrolyte. Electrons travel through the metal from anode to cathode. Ions move in the electrolyte and maintain charge balance. Removing any part stops that cell. Paint can exclude electrolyte; electrical insulation can interrupt a connection between unlike metals.
These parts need not be separate objects. Surface films, grain structure, stress and local composition can create anodic and cathodic regions on one steel plate. Different oxygen supplies also create a concentration cell. Beneath a deposit, oxygen is consumed and poorly replaced; that oxygen-poor region becomes anodic to the exposed surface.
Balance an iron example
For iron in neutral aerated water, write the anode reaction as . Oxygen reduction consumes four electrons, so multiply the iron reaction by two. Adding and canceling electrons gives:
Iron ions and hydroxide ions form iron(II) hydroxide. Further oxidation produces iron(III)-containing products; rust is a mixture of hydrated oxides and oxyhydroxides. Metal dissolves at the anode, but its solid products may collect elsewhere after ions move through the water. A thick rust deposit need not mark the deepest loss of metal.
For zinc in hydrochloric acid, the two-electron zinc oxidation already balances hydrogen evolution. The net reaction is . Hydrogen bubbles are the visible cathodic product while zinc atoms enter solution.
Key Takeaways
- Oxidation dissolves metal at the anode; reduction consumes electrons at the cathode.
- A wet cell requires both a metallic electron path and an electrolyte ion path.
- Balance electrons before adding half-reactions.
- An oxygen-poor area can become anodic on a single metal surface.
- Rust deposits can form away from the site of metal loss.
1.2 Use potentials to predict the reaction
Electrode potentials help identify which half-reaction supplies electrons and which accepts them. Keep the reference conditions attached to the numbers: a standard metal-ion half-cell and an alloy surface in seawater are different systems.
Read reduction potentials
Standard potentials are measured against the standard hydrogen electrode, assigned 0 V. At 25 °C, introductory tables use unit ion activity, commonly approximated by a 1 M solution. A more positive reduction potential means a stronger tendency for the reduction as written. In a connected metal couple under standard conditions, the more negative metal is oxidized.
Useful approximate values in volts are Mg −2.37, Al −1.66, Zn −0.76, Fe²⁺/Fe −0.44, Ni −0.25, Sn −0.14, Pb −0.13, H⁺/H₂ 0, Cu +0.34, Ag +0.80 and Au +1.50. The gold value refers to the Au³⁺/Au couple. Always retain the ion identity when a metal has several oxidation states.
Calculate the spontaneous cell voltage by subtracting the anode reduction potential from the cathode reduction potential:
For iron and copper, iron is the anode and . For zinc and copper it is 1.10 V. Doubling a half-reaction to balance electrons does not double its potential. Voltage is energy per charge, not the total energy of the reacting batch.
Allow for concentration
For a cell in which metal 1 is oxidized and metal 2 is reduced, both exchanging the same number of electrons, the 25 °C Nernst expression is:
Use a base-10 logarithm. With Fe²⁺ at 0.10 M and Cu²⁺ at 0.0010 M, the ratio is 100. Its logarithm is 2 and the correction is . The voltage falls from 0.78 V to about 0.72 V, remaining positive for iron oxidation. Reversing the concentration ratio changes the sign of the correction. At other temperatures replace 0.0592 V with using temperature in kelvin.
Choose the series for the environment
A galvanic series ranks actual metals and alloys by measured potential in a named environment. In seawater, magnesium and zinc are active; steel lies below copper alloys; passive stainless steels, titanium and noble metals lie toward the noble end. Stainless steel and nickel have separate active and passive positions because their surface films change their behavior.
Titanium illustrates why standard potentials alone are inadequate for service selection. Its Ti²⁺/Ti potential is about −1.63 V, yet its protective film places it near the noble end in seawater. Aluminum also has a negative standard potential but can corrode slowly under an intact oxide film. Potential difference indicates driving force; surface films, reaction rates and electrode areas determine how rapidly metal is lost. For an alloy joint, use a galvanic series for its service environment, then check those rate-controlling factors.
Key Takeaways
- Use cathode minus anode reduction potential for the cell voltage.
- Potentials stay unchanged when half-reactions are multiplied.
- The Nernst correction depends on the reaction quotient and temperature.
- Use an environment-specific galvanic series for alloys in service.
- Potential difference predicts tendency, while kinetics and films govern rate.
1.3 Calculate metal loss and explain the corrosion rate
A voltage tells you whether a reaction is favored. A corrosion rate tells you how quickly a component loses material. Mass measurements, electric current and surface-film behavior connect these two questions to service life.
Convert mass loss to penetration
For a cleaned coupon, the average corrosion penetration rate is:
Here mass loss is in mg, density in g/cm³, total exposed area in cm², and time in hours; the result is mm/yr. Include both faces and exposed edges. A 100 cm² steel coupon losing 250 mg in 720 h, at density 7.9 g/cm³, gives . A year contains 8,760 h for this conversion. In US industrial reports, 1 mil is 0.0254 mm, so this is about 1.5 mils per year.
An average penetration rate describes uniform thinning. A narrow pit can pass through a wall while producing little overall mass loss. Allowable rates therefore depend on the component's required life, thickness and failure mode; about 0.50 mm/yr is only a rough comparison value used for some applications.
Convert current to dissolved mass
Faraday's law relates charge to metal loss:
Use amperes and seconds. The molar-mass unit determines the mass unit of the result. For iron dissolving as Fe²⁺, . A pipe area of 5,000 cm² at 2 µA/cm² carries . Over s, using 55.85 g/mol, the loss is about 91 g. For uniform iron corrosion, 1 µA/cm² corresponds to about 0.0116 mm/yr. Current density, not total current alone, describes the intensity of loss over an exposed surface.
Find what limits the reactions
Polarization is the potential shift from equilibrium when a net current flows. The shift is the overvoltage, . Activation polarization reflects a slow reaction step and can follow . Concentration polarization reflects limited delivery of reactant, such as oxygen. The limiting current density rises when flow brings oxygen to the surface faster.
At the freely corroding mixed potential, total anodic and cathodic currents balance. On potential–log-current-density axes, their intersection gives the corrosion potential and corrosion current density. Faster oxygen reduction increases corrosion of actively dissolving steel. If the potential moves the metal into a passive region, the response can instead be a low corrosion current.
Recognize the passive region
Passivity comes from a thin, adherent oxide film. Aluminum, titanium and chromium-containing alloys benefit from it. Stainless steel contains at least about 10.5% chromium by mass and forms a chromium-rich film only a few nanometers thick. Its anodic current rises during active dissolution, falls on passivation, stays low in the passive range, and rises again in the transpassive region.
Chlorides can break a passive film locally. Stagnant, oxygen-poor gaps can hinder its repair. Temperature and flow also matter: flow can deliver reactants or strip films. Stainless steel must therefore be matched to the water chemistry and geometry; its low passive current is not a guarantee against local attack.
Key Takeaways
- The 87.6 penetration-rate constant requires mg, g/cm³, cm² and hours.
- Faraday calculations use charge in coulombs and the correct electron count.
- Mass-loss penetration rates average over the exposed area.
- The mixed-potential current balance determines the freely corroding rate.
- Activation and reactant transport can each limit current.
- A passive film lowers current but can fail locally.
1.4 Judge oxide scales and their growth
An oxide scale protects hot metal in dry gas if it stays attached and restricts further reaction.
Compare oxide and metal volumes
Metal oxidation supplies electrons for oxygen reduction. A compact scale restricts ion and electron transport; porous scale admits gas. An interface reaction can also control the rate.
The Pilling–Bedworth ratio compares the volume of oxide formed with the volume of metal consumed. For an oxide of formula :
Here is oxide formula mass, metal atomic mass, and their densities; counts metal atoms in the oxide formula, so Al₂O₃ has .
Magnesium gives . Aluminum gives . Below one, too little oxide volume tends to leave gaps. Between about one and two, a compact protective layer is possible. Well above two, large compressive stress promotes cracking and flaking, called spalling; tungsten has a ratio near 3.4.
A protective scale also needs adhesion, slow transport, a high melting point and low vapor pressure. Thermal-expansion mismatch can crack it on cooling. Molybdenum oxide evaporates at high temperature and gives no lasting barrier.
Recognize three growth laws
Let be mass gain per unit area and time.
| Growth law | Equation | Physical interpretation |
|---|---|---|
| Linear | Constant rate, possible with porous scale, repeated spalling or interface-reaction control | |
| Parabolic | Growth slows as transport through a thickening compact scale becomes harder | |
| Logarithmic | Very thin films, often at relatively low temperatures |
The constants apply to the specified temperature and units. Under , a gain of 2.0 mg/cm² at 100 h gives . At 400 h, the gain is . Four times the exposure doubles the gain. Linear growth through the first measurement would instead give 8.0 mg/cm².
Interpret mass gain correctly
Mass gain is added oxygen; oxide stoichiometry gives the metal consumed. Chromium, aluminum and silicon additions form slowly growing Cr₂O₃, Al₂O₃ and SiO₂ scales in heat-resistant steels and nickel-based superalloys.
Key Takeaways
- The Pilling–Bedworth ratio compares oxide volume with consumed metal volume.
- A ratio near one to two permits protection but does not establish it.
- Parabolic growth slows as the compact scale thickens.
- Linear kinetics can result from porous scale or interface-reaction control.
- Oxidation mass gain measures oxygen uptake.
2Identify forms of corrosion and choose ways to prevent them
The location and shape of damage help identify the conditions that caused it. Broad thinning, deep pits, attacked grain boundaries and delayed cracks each point toward a different combination of material, environment and stress. Choosing a remedy starts with that mechanism. Material selection, drainage, controlled water chemistry, coatings and electrochemical protection can then be combined to provide the required service life.
2.1 Identify thinning, galvanic attack, crevices and pits
The shape and location of corrosion damage are clues to its mechanism. Start with the service environment and the geometry of the damaged part, then connect them to the electrochemical cell.
Distinguish widespread and coupled attack
Uniform corrosion thins most of the exposed surface at a similar rate. Bare steel rusting over a broad area is a common example. Its predictable average loss allows inspection, planned replacement and added thickness.
Galvanic corrosion requires unlike potentials, electrical contact and a shared electrolyte. The more active metal becomes the anode and corrodes faster; the more noble surface supports cathodic reactions. A steel fastener in a copper plate is therefore vulnerable in seawater.
Area matters. If cathodic reactant supply controls the total current, a large cathode collects current that must be supplied by the anode. Delivering it through a tiny anode creates high anodic current density. An exposed steel rivet of 1 cm² in 100 cm² of copper has roughly 100 times the anodic current density of an equal-area arrangement under that model. A copper rivet in a broad steel plate spreads the anodic loss over a much larger steel area.
Choose nearby metals in the service galvanic series or insulate them with sleeves, washers and gaskets. If coating only one of the coupled metals, coat the cathode. Coating the anode alone can turn a scratch into a tiny exposed anode beside a large bare cathode. Coating both also reduces the exposed cell area.
Trace a crevice cell
Crevice corrosion occurs under gaskets, deposits or lap joints where liquid enters but is poorly exchanged. Oxygen inside is depleted; the exposed surface remains oxygenated. The gap becomes anodic. Dissolved metal ions accumulate, chloride enters to maintain charge balance, and hydrolysis acidifies the trapped liquid. These changes accelerate dissolution inside the gap.
Continuous welds, sealed joints, nonabsorbent gaskets, clean surfaces and complete drainage remove the geometry or retained liquid that sustains the cell. Replacing a grade without addressing an avoidable water trap can leave the cause in place.
Recognize pits and compare stainless steels
Pitting starts at a local breakdown of a passive film, often in chloride-containing water. Once established, a pit develops an acidic, chloride-rich interior much like a crevice. A small opening can hide deep penetration under corrosion products. Low coupon mass loss can therefore accompany a perforated wall.
For stainless steels, a common comparative composition index is:
Use mass percentages and the same nitrogen coefficient for all comparisons. Typical compositions give 18.8 for 304, about 26 for 316 and about 35 for duplex 2205. Molybdenum and nitrogen raise this index. Higher PREN indicates better relative pitting resistance within the comparison, but does not specify a safe temperature or guarantee seawater suitability. Type 316 can still pit or suffer crevice attack in seawater. Check the actual grade, chloride level, temperature, flow and joint design before selecting it.
Key Takeaways
- Galvanic attack needs electrical contact and a shared electrolyte.
- A small active anode next to a large cathode is a severe geometry.
- Stagnant crevices become oxygen-poor, acidic anodic regions.
- Pits can penetrate deeply with very little total mass loss.
- PREN compares stainless compositions; service suitability needs further checks.
- Coat the cathode or both metals of a galvanic couple.
2.2 Diagnose attack along grains, in flow and under stress
A component can lose strength without broad visible thinning. Grain-boundary chemistry, selective dissolution, moving liquid and tensile stress each produce characteristic damage and call for different remedies.
Examine boundaries and alloy constituents
Intergranular corrosion follows grain boundaries. In sensitized austenitic stainless steel, exposure around 500–800 °C allows chromium carbides to form there. Nearby metal loses chromium and may no longer remain passive. A band beside a weld can suffer this weld decay. Solution treatment around 1000–1100 °C followed by rapid cooling redissolves carbides. Low-carbon 304L or 316L, at most 0.03% carbon, limits carbide formation; titanium-stabilized 321 and niobium-stabilized 347 tie up carbon with other carbide-forming elements.
Selective leaching removes one alloy constituent. Dezincification removes zinc from susceptible brass and leaves a weak, porous, copper-rich red surface. Lower-zinc or dezincification-resistant brass reduces the risk. In gray cast iron, graphitic corrosion removes iron and leaves a graphite network. The pipe can retain its shape while losing most of its strength.
Look at the flow pattern
Erosion–corrosion combines chemical attack with mechanical film removal. Grooves and rounded channels aligned with flow often appear at elbows, tees, valves and impellers. Turbulence, solids and bubbles aggravate it. Lower velocity, smooth changes of direction, larger-radius bends and resistant materials address the mechanism. Cavitation adds damage from collapsing vapor bubbles near the surface.
Connect cracking to environment and stress
| Mechanism | Conditions and clues | Useful controls |
|---|---|---|
| Stress corrosion cracking (SCC) | Tensile stress plus an alloy-specific environment; cracks with little thinning | Reduce tensile stress, remove the species, or select a resistant alloy |
| Hydrogen embrittlement | Atomic hydrogen enters a susceptible metal; delayed brittle cracking under tension | Control hydrogen entry, use suitable heat treatment, and apply a specified post-plating bake |
SCC can occur below yield stress. Welding or cold working can leave enough residual tension. Brass is susceptible in ammonia-containing environments, austenitic stainless steel in warm chlorides, and carbon steel in hot concentrated caustic solutions. Stress-relief heat treatment lowers residual tension; shot peening places the surface in compression.
Hydrogen can enter during acid pickling, electroplating, welding with moisture, sulfide exposure or excessive cathodic protection. High-strength martensitic steel is particularly sensitive. Baking near 200 °C soon after plating can drive out diffusible hydrogen; the required schedule depends on the part and process.
Use the history to choose the remedy
A cold-worked brass fitting cracking in an ammonia-containing building points to SCC. A gray cast iron main that keeps its shape but cuts easily points to graphitic corrosion. A hardened bolt snapping hours after electroplating points to hydrogen embrittlement. Similar-looking cracks do not justify identical treatments: cathodic protection can suppress SCC in some systems, while excessive polarization can introduce hydrogen into high-strength steel.
Key Takeaways
- Sensitization depletes chromium beside grain-boundary carbides.
- Selective leaching can leave a weak part that keeps its shape.
- Flow-aligned damage suggests erosion–corrosion.
- SCC needs a susceptible alloy, tensile stress and a matching environment.
- Atomic hydrogen can cause delayed cracking in high-strength steel.
- Process and exposure history help distinguish cracking mechanisms.
- Cathodic overprotection can worsen hydrogen damage.
2.3 Choose material, environment and design controls
Corrosion resistance belongs to a material in an environment. Choosing an alloy, changing a liquid and removing a water trap can all be effective, but they address different causes of damage.
Match the material to the service
Stainless steels generally resist nitric acid well but can be attacked rapidly by hydrochloric acid. Aluminum performs well in neutral water yet dissolves in strong alkalis. Titanium and copper–nickel alloys are useful candidates for seawater equipment; plastics and fiber-reinforced plastics can suit acids that attack metals. Among stainless steels, 316 often improves chloride resistance over 304, but detailed service checks still matter.
Weathering steel forms an adherent rust layer during outdoor wet–dry cycles. Small alloy additions, including copper, chromium and nickel, support that layer. Constant dampness or accumulated chloride prevents it from giving the same benefit. A sheltered pocket that stays wet can therefore undermine a design that performs well on freely draining exposed faces.
Change the reaction conditions
Lower temperature usually slows corrosion. Reducing excessive fluid velocity limits film removal. Deaeration and oxygen scavengers reduce oxygen available for cathodic reduction in boiler water. Raising water pH can reduce steel corrosion in a suitable operating range.
An inhibitor is added at a small controlled concentration to lower the rate. Organic film-formers adsorb on metal; passivating inhibitors such as nitrites or molybdates promote protective films; scavengers remove oxygen. These methods fit contained, recirculating fluids where concentration can be maintained. Dosing open seawater around an entire ship hull is impractical.
Passivating inhibitors require adequate concentration. An incomplete film may leave a few active spots surrounded by a large passive surface, concentrating anodic current and accelerating pitting. Establish and monitor the required dose. Historical chromate inhibitors contain toxic hexavalent chromium and are restricted in many uses; inhibitor selection includes compatibility and exposure controls.
Remove the geometry that sustains attack
Design joints to exclude or release liquid. Prefer sealed or continuous welded joints where suitable, avoid absorbent gaskets, and make tanks drain completely. Keep dissimilar metals electrically isolated. Avoid tiny active fasteners in large noble surfaces, sharp flow changes, stress concentrations and unnecessary residual tension.
Provide room for inspection, cleaning and recoating. A surface that cannot be reached may be cheap to build but expensive to maintain. Replaceable wear or corrosion parts can keep the main structure in service.
Add thickness for predictable uniform loss
A corrosion allowance is added to the structural or pressure-required thickness:
At 0.10 mm/yr for 25 years, add 2.5 mm to the thickness needed to carry the load. This calculation assumes uniform loss continues at the adopted rate. Extra thickness does not remove an SCC mechanism or reliably control deep pits. Choose a separate treatment for local or cracking damage. The final choice compares material, design and protection together over the required life: painted steel with cathodic protection may be more economical than a much more resistant alloy.
Key Takeaways
- Select a material–environment pair, including temperature and exposure conditions.
- Weathering steel needs wet–dry cycles and performs poorly with persistent dampness or high chlorides.
- Contained systems allow inhibitor concentration to be controlled.
- Drainage, electrical isolation and inspection access are design controls.
- A corrosion allowance covers expected uniform loss.
2.4 Combine coatings and electrochemical protection
A coating reduces contact with the environment. Electrochemical protection changes which reaction the structure supports. Using both can reduce current demand while protecting exposed metal at coating defects.
Separate barrier and metallic coatings
Paints, lacquers and polymer linings act mainly as barriers. Surface cleaning and preparation, often grit blasting, give adhesion; edges and scratches are common starting points for underfilm corrosion. Primers may add inhibiting pigments or zinc dust.
| Coating on steel | Behavior at a wet scratch |
|---|---|
| Zinc, more active than steel | Zinc supplies electrons and is consumed; exposed steel is cathodic |
| Tin, nickel or chromium, more noble than steel | Exposed steel becomes a small anode beside a large coated cathode |
Hot-dip galvanizing applies zinc near 450 °C. Vitreous enamel fuses a glass layer onto steel. Anodizing thickens aluminum's oxide electrochemically, and phosphate conversion coatings help paint adhere. Their protection mechanisms and damage response differ, so the coating name alone is insufficient.
Supply electrons to the structure
Cathodic protection suppresses metal oxidation by making the structure cathodic. Sacrificial anodes of magnesium, zinc or aluminum alloy corrode to supply electrons. Magnesium gives a large driving voltage useful in high-resistivity soil; zinc and aluminum alloys are widely used in seawater. The anodes need electrical connection and an electrolyte path and must be replaced as they are consumed.
Impressed-current protection uses a DC source. Its negative terminal connects to the structure and its positive terminal to inert or slowly consumed auxiliary anodes in the electrolyte. Adjustable current suits large structures. Reversing the terminals would drive oxidation of the structure.
For a 0.20 A demand lasting one year, ideal magnesium consumption is:
At about 50% current efficiency, approximately 1.6 kg is consumed. Add the planned service-life and utilization margins separately; theoretical mass is not the installed anode size.
Interpret protection and access
A widely used buried or submerged steel criterion is −0.85 V or more negative against a saturated copper/copper-sulfate reference electrode, with protective current applied. Voltage drops outside the steel–electrolyte boundary must be considered. A negative reading containing substantial soil voltage drop does not by itself establish the interface potential.
Driving the potential too negative wastes current, can lift coatings and can introduce hydrogen into high-strength steel. Shielded regions may receive too little current, and surfaces above the electrolyte are not protected. Stray current can attack nearby metal where it leaves that metal.
Anodic protection uses a controller to hold a suitable active–passive metal within its passive potential range, for example in some sulfuric-acid equipment. This is a different operating principle from making the structure cathodic.
Key Takeaways
- Barrier coatings depend on adhesion and continuity.
- Zinc protects exposed steel sacrificially; a damaged noble coating can accelerate steel loss.
- Sacrificial and impressed-current systems both supply electrons to the protected structure.
- Connect the structure to the negative terminal in impressed-current protection.
- Correct reference-electrode readings for relevant external voltage drops.
- Coating defects and shielded regions require different current-access checks.
3Explain how polymers and ceramics degrade
Polymers and ceramics deteriorate through mechanisms tied to their structures. Liquids can enter polymer chains, while light, heat and reactive chemicals can change the chains themselves. Stress can turn a tolerable exposure into a cracking problem. Ceramics usually resist chemical attack well, yet particular liquids and high-temperature environments can dissolve them. Each case calls for a matching material or environmental control.
3.1 Explain why liquids soften or crack polymers
A polymer can deteriorate without a corrosion cell. Liquids may enter between its chains, dissolve them, or assist cracking under stress. The result depends on both the polymer structure and the contacting liquid.
Follow solvent molecules into the material
During swelling, small liquid molecules diffuse between polymer chains and push them apart. The part grows, softens and loses stiffness and strength. Its glass transition temperature falls as chain movement becomes easier. Dissolution goes further: separate chains disperse into a suitable solvent.
Linear and branched thermoplastics can dissolve. A cross-linked network cannot disperse into individual chains without breaking network bonds, so a thermoset or vulcanized rubber can swell while remaining connected. A change in dimensions is therefore possible even when a material does not dissolve.
Match chemical structure and exposure
“Like dissolves like” is a useful screening guide: similar chemical structure and polarity favor liquid uptake or dissolution. Hydrocarbon rubbers swell strongly in hydrocarbon fuels and mineral oils. Nitrile rubber is often used for fuel hoses and seals because its acrylonitrile-containing structure gives better resistance to those liquids.
Higher crystallinity limits accessible regions for liquid molecules. More cross-linking restricts swelling, and higher molecular weight and lower temperature generally improve resistance within a polymer–solvent comparison. These factors guide a choice, but compatibility data at service conditions decide whether the dimensional change is acceptable.
Polystyrene foam in acetone shrinks dramatically as the solid polymer dissolves and its cellular structure collapses. Vulcanized rubber in a suitable solvent can grow substantially while retaining its network. It may partly recover after the solvent leaves; the swelling during use can still destroy a seal's fit.
Account for moisture conditioning
Polar polyamides, including nylon, absorb water. At saturation, uptake can reach several percent by mass. Water acts as a plasticizer, lowering stiffness and strength while often increasing toughness. A nylon gear tested dry can therefore behave differently after prolonged humid service. Select dimensions and properties for the expected moisture condition, including dimensional tolerances as well as strength.
Recognize environmental stress cracking
Environmental stress cracking (ESC) combines stress with a liquid that may cause little damage to an unstressed specimen. Stressed polyethylene can crack in some detergent solutions. Polycarbonate and acrylic parts can craze or crack in contact with particular oils or solvents. Residual molding stresses count as stress even if the external load is small.
Reduce stress concentrations and residual stress, exclude the liquid, or choose a more resistant grade. Higher-molecular-weight polyethylene can improve ESC resistance. The mechanism resembles metal SCC in its need for stress and a matching environment, but it is not an electrochemical metal-dissolution cell. Cathodic protection does not prevent swelling or ESC. For a plastic container, identify the liquid, concentration, temperature and loading before accepting a chemical-resistance rating.
Key Takeaways
- Swelling absorbs liquid between chains; dissolution disperses chains into the liquid.
- Cross-linked networks swell but need bond breaking before they can dissolve.
- Chemical similarity, crystallinity and temperature affect liquid uptake.
- Moisture-conditioned nylon properties can differ greatly from dry values.
- ESC depends on the combination of stress and a particular liquid.
3.2 Explain weathering, bond damage and ceramic attack
Polymer degradation can change the chains themselves. Light, oxygen, water and heat may shorten chains or add cross-links, while ceramics and glass can suffer chemical attack despite their generally strong resistance.
Identify the molecular change
Chain scission breaks backbone bonds and lowers molecular weight. Strength and toughness often fall, and the material may discolor or become brittle. Extra cross-linking can also cause embrittlement by restricting chain movement. Similar surface symptoms can therefore arise from different molecular changes.
A photon's energy increases as wavelength decreases:
At 300 nm the energy is about 399 kJ/mol, compared with roughly 350 kJ/mol for a typical carbon–carbon single bond. At 600 nm it is about 199 kJ/mol. Absorption by the polymer or impurities is necessary for photochemical damage; a photon-energy comparison explains why ultraviolet light is particularly important, but energy alone does not specify a weathering rate.
Connect the chemical agent to the bond
Ozone attacks backbone double bonds in natural rubber and styrene–butadiene rubber. On a stretched part, characteristic cracks run across the stretch direction. Saturated-backbone rubbers such as EPDM and silicone resist this attack.
Hydrolysis uses water to break susceptible bonds, including ester links in PET and PLA and amide links in polyamides. Heat, acids and bases accelerate it. Drying PET before melt processing limits hydrolysis in the hot melt. Thermal degradation can also break chains and release gases; PMMA can depolymerize toward monomer, while overheated PVC releases hydrogen chloride. Strong carbon–fluorine bonds and aromatic backbone structures help PTFE, polyimides and PEEK tolerate higher service temperatures. Thermosets char instead of melting for reuse.
Slow outdoor weathering
Weathering combines ultraviolet light, oxygen, moisture, temperature cycling and pollutants. Yellowing, chalking, loss of gloss and surface cracks are useful clues. Carbon black and UV absorbers reduce light reaching vulnerable bonds. Hindered amine light stabilizers (HALS) capture reactive radicals. Antioxidants slow oxidation during processing and service; an opaque coating can shield the surface.
Biodegradation also needs the appropriate environment. PLA generally needs the heat and moisture of industrial composting for useful breakdown rates. A “biodegradable” label gives no service-life estimate in seawater or cool soil.
Check ceramics and glass against their chemicals
Strong ionic and covalent bonding gives many ceramics good chemical resistance. At high temperature, molten slag or glass can dissolve refractory linings. Silicate glass is attacked by hydrofluoric acid and by hot strong alkaline solutions. Water at a loaded glass crack tip can assist slow crack growth, so failure may occur long after loading without any increase in applied force.
Select a ceramic or polymer for the actual agent and temperature. UV stabilizers address light-driven polymer reactions; they do not stop a solvent from swelling a seal or a molten slag from dissolving a refractory.
Key Takeaways
- Chain scission lowers molecular weight; added cross-links can also embrittle polymers.
- Shorter-wavelength photons carry more energy.
- Ozone attacks susceptible double bonds, while hydrolysis attacks ester and amide links.
- UV screens, HALS and antioxidants act on different parts of weathering.
- Biodegradation depends on the disposal environment.
- Ceramics can dissolve chemically, and moisture can assist loaded glass cracks.
4Select materials using property charts and performance indices
A design brief becomes a materials decision when its job, limits and priorities are made explicit. Screening removes candidates that fail a requirement; ranking compares the survivors on equal performance. Deriving an index shows how material properties and the dimensions you may change work together. Logarithmic charts make that ranking visible, and grade-specific evidence turns a promising family into a practical shortlist.
4.1 Turn a design brief into a selection problem
A useful materials decision begins with the job the part must do. Separate requirements that every candidate must meet from the quantity you want to improve, then compare materials on that common basis.
Translate the brief
Record four statements:
| Statement | Question | Example for a lightweight tie |
|---|---|---|
| Function | What does the part do? | Carry an axial tensile load |
| Constraints | What must it achieve? | Fixed length, limited extension, outdoor resistance |
| Objective | What should be minimized or maximized? | Minimize mass |
| Free variables | What may change? | Material and cross-sectional area |
A required stiffness expresses the extension limit. A maximum permitted mass is a constraint, while “as light as possible” is an objective. A brief may contain several constraints even when ranking uses one objective. If mass and cost both matter, their conflict needs a trade-off decision.
Free variables determine which performance equation applies. If area can change, a lower-modulus material can compensate with a larger section. If the entire geometry is fixed, that compensation is unavailable. Write dimensional limits explicitly before choosing an index.
Screen with pass/fail requirements
Screening rejects materials that fail any constraint. A service temperature of 120 °C requires adequate properties at that temperature, not just a room-temperature melting point. A toughness requirement of 15 MPa·m^1/2 removes materials below that limit. Chemical resistance, electrical insulation and available processing routes can also serve as screening attributes.
A candidate that performs exceptionally well on one property cannot make up for failing a mandatory limit. Check all limits before spending effort on a detailed ranking. A chemically incompatible polymer remains unsuitable even if its low density is attractive.
Rank the survivors
Ranking compares feasible materials by a derived combination of properties, a performance index. For a light stiff tie with free area, the index is . It rewards stiffness while penalizing density and arises from meeting the same required stiffness for every candidate. It does not simply choose the highest modulus.
Separating the objective into fixed functional and geometric factors and a material factor can make one index useful across a whole class of designs. The derivation states which loads, dimensions and failure limits are held fixed. Change those conditions and the ranking can change.
Document the short list
The leading candidate still needs grade-specific evidence. Check availability, supplied shapes, manufacturing, joining, corrosion under the actual exposure, damage resistance and experience in similar products. Family-level chart bubbles span ranges; a heat treatment or fiber direction can move the relevant properties substantially.
For the tie, an aluminum alloy might pass the outdoor-resistance screen and have competitive specific stiffness. Documentation must still establish a suitable grade, joint details, section size and fabrication route. A shortlist is the start of that detailed engineering decision, not a complete component design.
Key Takeaways
- Translation separates function, constraints, objective and free variables.
- A constraint is mandatory; an objective ranks feasible choices.
- Screen all mandatory limits before ranking.
- A performance index depends on loading and available geometric changes.
- Document grade, processing, joining and service behavior for the short list.
4.2 Derive an index from the objective and constraint
A performance index follows from a physical model. Write the quantity to minimize, use the active constraint to eliminate a free dimension, and collect the material properties that remain.
Derive a light stiff tie
For length , area and density , mass is . Axial stiffness is . At the minimum area that meets the stiffness requirement, . Substitution gives:
With length and required stiffness fixed, minimize or maximize . This is specific stiffness. A strong tie instead requires , producing and the index . For a ductile metal, failure strength in this model normally means the allowable yield-based strength.
Derive a light stiff beam
A square beam has . Its bending stiffness is , where the support and loading determine ; a simply supported beam with a central load has . Solving for area gives:
Then . The material index is . Modulus enters with a smaller exponent because increasing section size improves the second moment of area strongly.
Compare the appropriate models
| Minimum-mass function | Index to maximize |
|---|---|
| Stiff tie, area free | |
| Strong tie, area free | |
| Stiff beam, similar section shape and size free | |
| Strong beam, similar section shape and size free | |
| Stiff panel, length and width fixed, thickness free | |
| Strong panel under the same geometric freedom | |
| Strong solid shaft, diameter free |
If beam depth is fixed and only width changes, is proportional to width and the stiffness index becomes . The name “beam” alone does not determine the exponent.
Read a ranking as a mass comparison
Using GPa and Mg/m³ consistently, steel with 210 and 7.85 has specific stiffness 26.8; aluminum with 70 and 2.70 has 25.9. They are close for stiff ties. For a 2.0 m tie needing stiffness , gives 476 mm² of steel or 1429 mm² of aluminum. Multiplying area by length and density gives 7.48 kg and 7.71 kg. The aluminum tie needs more area, so its lower density does not give a mass saving here. Their stiff-beam indices are 1.85 and 3.10, so the aluminum mass for equal bending stiffness is of the steel mass.
For CFRP at 60 GPa and 1.55 Mg/m³, the beam index is 5.00; spruce along the grain at 10 GPa and 0.45 Mg/m³ gives 7.03. Low density is rewarded strongly, but the required section may be much larger. Screen size, directionality, strength, buckling and damage separately. Use one unit system across all candidates.
Key Takeaways
- Eliminate the free geometric variable using the binding constraint.
- Light stiff ties maximize specific stiffness.
- Light stiff beams with scalable similar sections maximize the square-root modulus index.
- Panel and shaft indices have their own geometry-dependent exponents.
- For a shared model, equal-function mass is inversely proportional to the index.
- Fixed depth can change the beam index.
4.3 Read and use logarithmic property charts
Property charts compare material ranges; constant-index lines rank them under a shared design model.
Read the axes and bubbles
An Ashby chart commonly plots modulus vertically against density horizontally. Each step between decade marks multiplies the value by ten. The halfway position between 10 and 100 GPa is , not 55 GPa.
Material classes occupy envelopes, and individual grade ranges appear as bubbles. Metals typically occupy relatively high stiffness and density; engineering polymers are mostly around 0.2–5 GPa and 1–2 Mg/m³. Elastomers can be near 0.001–0.1 GPa. Foams are light and compliant; woods and composites have strong directional and processing effects. A bubble represents a range, not an exact design value.
Convert an index into a line
Let the mass index be . Rearranging yields . Therefore:
| Index | Slope on modulus–density log axes |
|---|---|
| 1 | |
| 2 | |
| 3 |
These slopes require modulus vertically and density horizontally. On strength–density axes, the corresponding slopes are 1 for , 1.5 for and 2 for .
Points on one line have equal index. Move it parallel upward or toward lower density to seek better performance; materials above it have a higher index.
Combine screens with ranking
First apply the mandatory property limits. A stiffness screen of excludes ordinary magnesium alloys near 45 GPa, woods and unreinforced polymers. Steel, aluminum alloys, suitable CFRP and many ceramics remain. A toughness screen may then eliminate brittle ceramics; environmental resistance further narrows the set.
For a stiff-beam comparison, a slope-2 line through steel has index 1.85 in GPa and Mg/m³ units. At aluminum's density of 2.70 Mg/m³, the equal-performance line requires . Aluminum's 70 GPa is above it, explaining its better mass performance for this beam model.
Finish with actual grade data
Other charts compare strength, toughness, cost per volume and embodied energy. Add chemical-resistance screens, then verify the shortlisted grade, heat treatment, fiber orientation and temperature.
Key Takeaways
- Log-axis midpoints are geometric means.
- A bubble shows a property range.
- The index exponent determines the selection-line slope.
- Screen mandatory limits and then move a parallel ranking line toward higher index.
- Chart candidates still need grade-specific documentation.
5Weigh cost, life cycle and recycling in material choices
Mass, purchase price and environmental impact describe different parts of a material choice. An equal-function comparison reveals how much material and processing each design needs. Life-cycle cost adds the timing of maintenance and replacement, while an eco-audit tracks where energy or emissions arise. Recovery at end of life depends on clean material streams and separable products, so durability and recycling belong in the original design decision.
5.1 Compare the cost of doing the same job
Compare the material quantity and processing needed for the same function, not price per kilogram alone.
Replace mass with material cost
If is price per kilogram, material cost is . In a minimum-mass derivation, replacing density by gives the corresponding material-cost index:
| Function | Index for minimum material cost |
|---|---|
| Stiff tie | |
| Stiff beam with similar scalable sections | |
| Strong solid shaft |
These indices rank raw material cost under the original loading and geometry assumptions.
Using illustrative relative prices per kilogram of steel 1, aluminum 3.5, CFRP 50 and spruce 1.5, their stiff-beam cost indices are about 1.85, 0.88, 0.10 and 4.7. Steel beats aluminum and CFRP on raw material cost, even though those candidates can make lighter beams. Spruce's high index is useful only if its required size, directionality and environmental resistance pass the design screens.
Identify a real trade-off
For parts providing the same function, plot cost against mass. A candidate is dominated if another feasible candidate is no heavier and no more expensive, with an improvement in at least one. The Pareto front contains choices for which improving mass requires accepting higher cost, or improving cost requires accepting higher mass.
Choose a point using the product’s value for mass saving: a launch vehicle can justify a greater cost per kilogram saved than a stationary support.
Add manufacturing and batch costs
Component cost includes material, processing, energy, labor, tooling, joining, finishing and quality checks. Machining a titanium part from a large billet may discard much of an expensive input. A suitable near-net-shape route can reduce scrap and machining time.
Tooling is spread across production quantity. A mold costing 50,000 cost units adds 5 per part over 10,000 parts, but only 0.05 over 1,000,000 parts. Fixed tooling and variable costs together determine when molding becomes cheaper than machining.
Simplifying geometry and reducing joints can lower cost without changing material. A corrosion-resistant alloy may remove painting and finishing steps, offsetting a higher purchase price. Treat chart prices as estimates and obtain current supplier and process data before committing to production.
Key Takeaways
- Compare cost per function using the mass actually required.
- Material-cost indices replace density with price per kilogram times density.
- Pareto choices trade mass against cost without being dominated.
- Processing, tooling, joining and finishing contribute to component cost.
- Divide fixed tooling cost by the production quantity.
5.2 Compare costs over the service life
Life-cycle cost compares acquisition, maintenance and end of life, including when each payment occurs.
Set the comparison period and boundary
Life-cycle cost (LCC) includes material, fabrication and installation; operation, inspection, maintenance and downtime; and removal or disposal minus residual scrap value. Compare designs that deliver the same function for the same service period. Lost production can cost more than the repair itself.
A 40-year handrail example uses neutral cost units. Painted carbon steel costs 1,000 initially and 400 to repaint in years 8, 16, 24 and 32. Undiscounted cost is . A 316 stainless handrail costs 2,200 initially with negligible maintenance in this example. Stainless saves 400 before discounting.
Bring future payments to the present
Discount a cost paid at the end of year using annual discount rate :
Enter 3% as 0.03. Discount each payment for its own year, then add the present values to the initial cost. For the handrail at 3%, the four repaintings total about 917 in present value, so painted steel costs about 1,917. At 5%, its total is about 1,662. Both are below the stainless initial cost in this simplified comparison.
A higher rate lowers distant payments’ present value. Divide by the growth factor; multiplying finds a future equivalent. Initial payments are not discounted.
Test what could change the choice
Maintenance intervals, service life, access cost and downtime can reverse the ranking. Repainting on an easily reached indoor handrail differs from repainting above operating equipment. Include scaffolding or closure costs when they apply, and count a higher scrap value as an end-of-life benefit at its actual date.
A long life can justify durable materials, but a component replaced in a few years for other reasons may gain little from 50-year corrosion resistance. Where failure could harm people or cause a serious release, the design first needs acceptable reliability; a low calculated LCC cannot make an unacceptable failure risk satisfactory.
Corrosion costs are substantial at system level. The 2016 NACE IMPACT study estimated about 2.5 trillion US dollars annually, based on roughly 3.4% of world GDP in 2013, and estimated that existing corrosion-control practices could save 15–35%.
Key Takeaways
- Compare equal functions over a shared service period.
- Include downtime, access and end-of-life value where relevant.
- Discount each future payment by its own date.
- Higher discount rates reduce the present weight of distant maintenance.
- Reliability requirements remain constraints on a cost choice.
5.3 Compare environmental burden per useful function
Compare equal-function designs through production, use and end of life: lower mass can require more production energy.
Follow the materials cycle
The cycle runs from extraction through refining or synthesis, material processing, manufacture and use to reuse, remanufacturing, recycling, energy recovery or disposal. Use can require energy, maintenance and replacement. Recycling returns material to processing; reuse preserves the component.
Embodied energy measures energy used to produce material from resources, usually per kilogram. A carbon footprint measures greenhouse-gas emissions as carbon dioxide equivalent. They are related but different quantities: energy sources can have different emissions per unit of energy. Compare candidates using one consistent data source and boundary.
Multiply by the mass needed
Illustrative values are 25 MJ/kg for primary steel, within a common 20–30 range, and 186 MJ/kg for primary aluminum versus 8.3 MJ/kg for remelted scrap aluminum in the cited 2019 industry data. A 10 kg steel beam embodies 250 MJ. An equal-stiffness aluminum beam of 6 kg embodies 1,116 MJ from primary metal, about 870 MJ more, or about 50 MJ using the recycled-metal value.
The correct denominator is a functional unit: a part delivering the same required stiffness and service life. Comparing 1 kg of each material ignores the different quantity required to provide the function. Check that both designs also meet strength, space and durability requirements.
Find the dominant phase
An eco-audit estimates energy or carbon in material production, manufacture, transport, use and end of life. Energy-consuming products often have a large use-phase burden. In such a case a mass saving can repay higher embodied energy through lower operating energy. A stationary beam has no comparable vehicle propulsion saving; its material production and replacement frequency can dominate instead.
For the primary-aluminum beam, lifetime use savings must exceed about 870 MJ just to repay the material-energy difference. Compare that saving with any extra manufacturing or maintenance burden before concluding that the total is lower.
Include durability and recovery
Longer service life spreads production burdens over more years and avoids replacement. Protection also uses resources: sacrificial anodes are consumed and coatings require manufacture and maintenance. A low-mass product that fails early may require several replacements to perform the same lifetime function.
Key Takeaways
- Follow extraction, manufacture, use and every relevant end-of-life route.
- Embodied energy and carbon footprint measure different quantities.
- Compare equal-function designs, including service life.
- A primary-aluminum mass saving can need substantial use-phase energy savings to repay production energy.
- An eco-audit identifies the dominant life phase.
- Durability and protection affect lifetime resource use.
5.4 Design products whose materials can be recovered
Recovery depends on how a product is collected, separated and reprocessed. A material may be technically recyclable yet enter a waste stream that cannot deliver clean feedstock at a useful cost.
Preserve value before remelting
Reuse and remanufacturing keep whole products or components functioning and usually save more manufacturing effort than material recycling. Recycled content describes input to a new product. The end-of-life recycling rate describes the fraction of discarded material actually recovered. A high value for one does not establish the other.
Metals can be remelted repeatedly with controlled composition. Magnetic separation recovers steel; eddy-current equipment separates nonferrous metals. Aluminum remelting at 8.3 GJ/t compared with primary production at 186 GJ/t gives an energy saving of , about 95%.
Contamination limits the value of scrap. Copper and tin are difficult to remove from steelmaking streams, and copper can cause cracking in hot working. Mixed aluminum alloys often become casting alloys that tolerate more silicon and iron. Separating alloy streams preserves options for higher-value reuse.
Match recovery to material structure
| Material | Common route | Main limitation |
|---|---|---|
| Glass | Crush into cullet and remelt | Sort by color and exclude ceramics, stones and incompatible glass |
| Thermoplastic | Sort, melt and remold | Incompatible resin mixtures and molecular degradation |
| Thermoset or vulcanized rubber | Grind into filler or use specialist recovery | Cross-linked networks do not remelt |
| Fiber composite | Grind, or recover fibers by thermal or chemical processing | Separating matrix and fibers while preserving useful quality |
Resin identification codes are 1 PET, 2 HDPE, 3 PVC, 4 LDPE, 5 PP, 6 PS and 7 other or mixed plastics. They identify resin types; local collection acceptance is a separate question. Moisture-sensitive polymers such as PET and polyamides can undergo hydrolysis during reprocessing, while other polymers may undergo scission, branching or additional cross-linking. Sorting and conditioning help preserve quality.
Chemical recycling can depolymerize suitable polymers toward monomers or use pyrolysis to form oils and gases. It can handle some streams unsuitable for mechanical recycling, but uses more energy than direct remelting. Ground tires become crumb rubber; devulcanization recovers only part of the original properties. Thermoset composite recovery can preserve carbon-fiber length, although cutting and handling may shorten fibers. Glass-fiber composites can enter cement-kiln routes, using resin as fuel and mineral content as feedstock.
Make separation possible
Use fewer compatible materials, mark plastic types and make parts accessible. Screws or snap fits can allow unlike parts to separate; inseparable adhesive joints and multilayer laminates can contaminate a stream. Avoid unnecessary coatings and inserts that reduce scrap value. Where performance permits, a thermoplastic can offer a remelting route unavailable to a thermoset. Design the recovery route alongside the service requirements, then check collection, sorting and markets for the intended destination.
Key Takeaways
- Reuse and remanufacturing preserve component value before material reprocessing.
- Recycled content and end-of-life recycling rate describe different flows.
- Clean, separated alloy streams retain more value.
- Thermoplastics remelt; cross-linked thermosets and rubbers do not.
- Glass recycling needs clean, composition-compatible cullet.
- Composite recovery must manage both matrix and fibers.
- Accessible, separable joints improve recovery.
Corrosion and Materials Selection examples
1From electrode reactions to a metal-loss prediction
17 steps
- 1IntroductionFollow matter and charge
Metal oxidation supplies electrons to a connected reduction reaction. Trace the cell’s paths, then separate its driving voltage from its metal-loss current.
In dry oxidation, ask whether the growing scale restricts transport.
- 2ExplanationBuild the complete cell
A wet cell needs anodic oxidation, cathodic reduction, a metallic electron path and an electrolyte ion path.
Different areas of one plate can provide the two reactions; electrons travel through metal and ions through liquid.
- 3ExampleBalance the electron transfer
Iron releases two electrons per atom: . Oxygen reduction in neutral water consumes four: .
Double the iron reaction before adding them. Two iron atoms dissolve for each oxygen molecule reduced, and no electrons remain in the net equation.
- 4ChallengeCan acid corrosion continue without oxygen?
A zinc sample is in oxygen-free acid. Can a corrosion cell still operate? Name the cathodic reaction.
---reveal---
Yes. Zinc oxidation supplies electrons to hydrogen-ion reduction: . The metal path and acid electrolyte connect the reactions. Removing oxygen stops oxygen reduction, but does not remove this alternative cathodic reactant.
- 5ExampleFind the standard driving voltage
Take an iron–copper cell under standard conditions. The reduction potentials are −0.44 V for Fe²⁺/Fe and +0.34 V for Cu²⁺/Cu.
Iron has the more negative value and supplies the oxidation reaction. Subtract its tabulated reduction potential from copper's: . Keep both signs when subtracting.
- 6ExampleApply the concentration correction
Keep the same cell at 25 °C, but use Fe²⁺ at 0.10 M and Cu²⁺ at 0.0010 M. Both ions exchange two electrons.
The ratio is , whose base-10 logarithm is 2. Thus . The voltage falls but remains positive for iron oxidation.
- 7ChallengeChoose the right evidence for a seawater joint
An engineer ranks a titanium–steel seawater joint only with standard metal-ion potentials. What important effect is missing, and which evidence includes it?
---reveal---
The surface films are missing. Passive titanium behaves much more nobly in seawater than its pure-metal standard potential suggests. Use a seawater galvanic series that includes the relevant surface states, then check geometry and reaction rates.
- 8ExamplePut the coupon data in the right units
A steel coupon has 100 cm² total exposed area and loses 250 mg in 30 days. Its density is 7.9 g/cm³.
The constant 87.6 requires hours, so use . Include all wetted faces in the stated area. The average penetration calculation is .
- 9ExampleConvert current density into current
A steel surface of 5,000 cm² corrodes at 2 µA/cm². Multiply before applying Faraday's law:
For one year, use seconds. Current density describes the rate per area; total current measures charge per second over the complete exposed region.
- 10ExampleTurn charge into iron loss
Assume iron dissolves as Fe²⁺, so each mole of iron releases two moles of electrons. With molar mass 55.85 g/mol:
The same charge would imply a different mass for a different electron count or molar mass. Those quantities come from the actual dissolution reaction.
- 11Key InsightWhy voltage and rate can disagree
A favorable voltage need not produce a large corrosion current. Surface kinetics, reactant delivery and passive films can slow the reactions.
Local film breakdown can concentrate attack while much of the surface remains resistant.
- 12ChallengeInterpret faster flow in an active system
Actively corroding steel is limited by oxygen delivery. Flow increases oxygen transport, and the steel stays active. What happens to its corrosion current?
---reveal---
It increases. Faster cathodic oxygen reduction requires a larger balancing anodic current, which means faster iron dissolution. The result depends on the stated active behavior; a transition into a passive region would require a different reading of the polarization curve.
- 13ExplanationLook for a protective scale
A compact oxide can slow transport through the surface layer. A Pilling–Bedworth ratio near one to two permits coverage.
Adhesion, slow diffusion and resistance to thermal cracking or evaporation are also needed for protection.
- 14ExampleUse parabolic growth
For zero-intercept parabolic oxidation, . A gain of 2.0 mg/cm² in 100 h gives in compatible units.
At 400 h, . The thickening scale slows further growth. A linear model through the first point would predict 8.0 mg/cm² instead.
- 15ChallengeDistinguish oxygen uptake from metal consumption
A dry oxidation test records a 10 mg mass gain with no scale loss. Has exactly 10 mg of metal been consumed? Explain.
---reveal---
No. The gain is oxygen added to the retained specimen. Calculate metal consumption from the oxide formula and molar masses. For example, one mole of a simple MO oxide contains one mole of metal but only one mole of oxygen atoms; these masses are different.
- 16ChallengeCombine an average rate with a failure clue
A steel wall shows a low coupon-average corrosion rate but develops a leak at one narrow hole. Why can these observations agree, and what should be measured next?
---reveal---
Localized pitting can remove little total metal while penetrating deeply. Measure pit depth and remaining wall thickness at the damaged sites. An average mass-loss rate spreads the loss over the coupon and cannot describe the maximum local penetration.
- 17RecapKeep three questions separate
Identify the oxidation and reduction reactions, use potentials for direction, and use current or mass loss for rate.
For dry oxidation, establish the scale behavior and growth law before extrapolating exposure time.
2Diagnose damage and choose a matching control
18 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the evidence of damage
- 2ExplanationCompare broad thinning with local holes
- 3ExampleFind the concentrated anode
- 4ChallengeDecide which coupled surface to coat
- 5ConnectionSee why a gap becomes aggressive
- 6ExplanationConnect weld heat to grain boundaries
- 7ExampleRead flow damage and selective loss
- 8ChallengeUse the plating history
- 9Key InsightResidual tension still counts as stress
- 10ExplanationChoose a compatible material and exposure
- 11ExampleAdd thickness for uniform loss
- 12ChallengeExplain an inhibitor failure
- 13ExplanationCompare two damaged metal coatings
- 14ExampleTrace an impressed-current connection
- 15ChallengeCorrect the ideal anode estimate
- 16TipRead a potential at the right interface
- 17ChallengeCombine geometry and protection
- 18RecapMatch the intervention to the cause
3Explain a nonmetallic part failure
11 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionAsk what changed in the material
- 2ExplanationSeparate uptake from dissolution
- 3ExampleCondition a nylon part for service
- 4ChallengeDiagnose a detergent-exposed corner
- 5ExampleCompare photon energies
- 6ExplanationConnect the agent to a vulnerable bond
- 7Key InsightChoose the additive for its job
- 8ChallengeExplain delayed failure of glass
- 9ConnectionCheck the disposal environment too
- 10ChallengeSeparate two causes of loss of stiffness
- 11RecapUse structure to explain the symptom
4Derive and use a lightweight-material ranking
15 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionCompare equal jobs
- 2ExampleTranslate a lightweight tie
- 3ChallengeSeparate a limit from a priority
- 4ExampleWrite the tie's two equations
- 5ExampleEliminate the free area
- 6ExplanationLet bending change the exponent
- 7ExampleCompare steel and aluminum beams
- 8ChallengeChange the free dimension
- 9ConnectionKeep panel and shaft models distinct
- 10ExplanationRead ratios on a logarithmic axis
- 11ExampleTurn the beam index into a line
- 12ChallengeCheck a chart point against the line
- 13TipScreen before chasing the highest bubble
- 14ChallengeCombine screening and ranking
- 15RecapKeep the model attached to the index
5Choose between competing lifetime designs
16 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionSet one useful basis for comparison
- 2ExplanationInclude the mass needed for the job
- 3ExampleSpread the tooling cost
- 4ChallengeRemove a dominated candidate
- 5ExampleList the payments before discounting
- 6ExampleApply the time value of money
- 7ChallengeFind a missing lifetime cost
- 8ExplanationTrack the environmental life phases
- 9ExampleCalculate the production-energy difference
- 10ExampleFind the energy break-even point
- 11ChallengeInclude an extra replacement
- 12ExplanationPreserve clean material streams
- 13ConnectionLet structure determine the recovery route
- 14ChallengeImprove the product's exit route
- 15ChallengeCombine durability, cost and energy
- 16RecapChoose the trade-off with evidence
Corrosion and Materials Selection practice questions
Set 1: Connect corrosion mechanisms with material choices10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Apply rates, compatibility and design constraints10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Compare damage, performance and lifetime burdens10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Check assumptions in corrosion and selection models10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 5: Resolve multistep material and lifetime decisions10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
A
Activation polarization
Anode
Anodic protection
Antioxidant
Ashby chart
B
Barrier coating
Biodegradation
C
Carbon footprint
Cathode
Cathode-to-anode area ratio
Cathodic protection
Cell potential
Chain scission
Chemical compatibility
Chemical recycling
Concentration polarization
Corrosion
Corrosion allowance
Corrosion inhibitor
Corrosion penetration rate
Cost per function
Crevice corrosion
Cullet
Current density
D
Deaeration
Design constraint
Design for disassembly
Design objective
Differential aeration cell
Discount rate
Dissolution
Dominated candidate
Downtime cost
E
Eco-audit
Electrolyte
Embodied energy
End-of-life recycling rate
Environmental stress cracking
Erosion–corrosion
F
Faraday's law
Free variable
Functional unit
G
Galvanic corrosion
Galvanic series
Graphitic corrosion
H
Half-reaction
Hindered amine light stabilizer
Hydrogen embrittlement
Hydrolysis
I
Impressed-current protection
Intergranular corrosion
L
Life-cycle cost
Linear oxidation
Logarithmic axis
M
Materials cycle
Materials documentation
Materials screening
Mechanical recycling
Mixed potential
N
Near-net-shape processing
Nernst equation
Noble coating
Noble metal behavior
O
Oxide scale
Oxygen scavenger
P
Parabolic oxidation
Pareto front
Passivity
Performance index
Pilling–Bedworth ratio
Pitting corrosion
Pitting resistance equivalent number
Plasticization
Polarization
Present value
Property envelope
R
Recycled content
S
Sacrificial coating
Second moment of area
Selection line
Selective leaching
Sensitization
Spalling
Specific stiffness
Specific strength
Standard electrode potential
Standard hydrogen electrode
Stiffness-limited design
Strength-limited design
Stress corrosion cracking
Subcritical crack growth
Swelling
T
Tooling cost
U
Ultraviolet absorber
Uniform corrosion
W
Weathering
Weathering steel
Weld decay
About this lesson
Make your own Study Materials
Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.