Series and Parallel Circuits

Learn how current and voltage share out in series, parallel and mixed DC circuits. Calculate equivalent resistance, voltage drops, branch currents and power, and use Kirchhoff's laws to find unknown values and check every result. Allow for the internal resistance of batteries and the voltage lost in supply cables, combine cells into battery packs, see how capacitors charge and discharge, and confirm your calculations with multimeter measurements.

BeginnerLesson 2 of 7 in Electrical Principles for Technicians Course

What you will learn

  1. Read circuit diagrams, tell series, parallel and mixed connections apart, and use the series rules and Kirchhoff's voltage law to find the current, the voltage drops and the power.
    • Read circuit diagrams and recognize series and parallel connections
      Use circuit symbols, nodes, branches and loops to decide whether components are connected in series, in parallel or in a mixed arrangement.
    • Calculate current, voltage drops and power in a series circuit
      Add resistances, find the shared current and the voltage across each component, and check the result with Kirchhoff's voltage law.
    • Use voltage dividers and predict faults in series circuits
      Apply the voltage divider rule, size a series dropping resistor, and explain what open circuits and short circuits do to a series circuit.
  2. Use Kirchhoff's current law and the rules for parallel resistors to find branch currents, total current, equivalent resistance and power, and predict what adding loads or faults does.
    • Find branch currents and equivalent resistance in a parallel circuit
      Apply the same-voltage rule, Kirchhoff's current law and the reciprocal formula for resistors in parallel.
    • Divide current, find power and predict faults in parallel circuits
      Share a known current between branches, find branch and total power, and explain how adding loads, open branches and short circuits change a parallel circuit.
  3. Reduce series-parallel circuits to one equivalent resistance, work back to every current, voltage and power, and use Kirchhoff's laws to find unknown values and check results.
    • Reduce a mixed circuit to one equivalent resistance
      Find groups of components that are purely in series or purely in parallel, replace them step by step and redraw the circuit after each step.
    • Work back to every current, voltage and power in a mixed circuit
      Use the supply current and the redrawn circuits to find each component's values, check them with Kirchhoff's laws and a power balance, and calculate loaded voltage dividers.
    • Use Kirchhoff's laws to find unknown values and check circuits
      Write current and voltage equations with consistent signs, solve for one unknown at a time, and handle sources that aid or oppose each other.
  4. Model batteries and other sources with an internal resistance, combine cells in series and parallel, and calculate the voltage lost in supply cables.
    • Calculate terminal voltage with internal resistance
      Tell EMF and terminal voltage apart, find a source's internal resistance from measurements, and explain short-circuit current and maximum power transfer.
    • Combine cells and batteries in series and parallel
      Calculate the EMF, internal resistance and capacity of series, parallel and series-parallel battery arrangements, and recognize combinations that are unsafe.
    • Calculate voltage drop in cables and choose a cable size
      Find a cable's resistance from its length, cross-section and material, calculate the voltage drop and power loss, and compare the drop with a design limit.
  5. Calculate charge, energy and combined capacitance, and describe and calculate how a capacitor charges and discharges through a resistor.
    • Calculate charge, energy and combined capacitance
      Relate charge, capacitance and voltage, combine capacitors in series and parallel, and explain how a capacitor behaves once a DC circuit has settled.
    • Calculate charging and discharging through a resistor
      Use the time constant to work out how quickly a capacitor charges and discharges, and discharge capacitors safely before work.
  6. Measure voltage, current and resistance correctly, allow for meter effects and tolerances, and use the differences between measured and calculated values to find faults.
    • Measure voltage, current and resistance in a DC circuit
      Connect a multimeter correctly for each quantity, read DC values and their polarity, and allow for the meter's own effect on the circuit.
    • Compare measurements with calculations and locate faults
      Predict values before measuring, judge whether differences are within tolerance, and use voltage and current readings to find open circuits, short circuits and high-resistance joints.

Series and Parallel Circuits study guide

6 chapters

1

Series paths and voltage division

Following the wires is the first step in a series calculation. A single path makes the current common to every component, while the source voltage is shared among their resistances. Circuit symbols and node labels show whether that model fits the drawing. From there, resistance, voltage, and power calculations explain normal operation, voltage dividers, and the changes caused by a break or a bypass.

1.1 Connections on a circuit diagram

A circuit diagram shows where current can flow. It describes the electrical connections, so the shape and position of the wires on the page can change without changing the circuit. Start by tracing a complete path from one source terminal, through the loads, and back to the other terminal.

Read the symbols

An IEC resistor is a rectangle; the ANSI resistor common in US drawings is a zigzag. Both mean resistance. A cell has one long line for positive and one shorter, thicker line for negative. Repeated cell symbols represent a battery. An IEC lamp is a circle with a cross. Circles marked V and A represent a voltmeter and an ammeter.

Conventional current travels from positive to negative through the external circuit. Electrons in metal move the other way. Use the conventional arrows when following the diagram and interpreting a meter's polarity.

Mark the nodes

A node is a connection shared by components. All points joined by uninterrupted wire form one node: following that wire through a bend does not create a new node. These points have the same potential in the circuit model. A component between two points separates their nodes. A branch is a path between nodes, containing one or more components. A loop is a closed path.

Label each stretch of connected wiring A, B, C, and so on. Then record the two node labels at each component's ends. This makes connections easier to recognize when a drawing has long return wires or components facing different directions.

ConnectionTest using the wiresElectrical result
SeriesComponents share a connection with no other path branching from itThey carry the same current
ParallelBoth ends connect to the same two nodesThey have the same voltage

Two resistors that merely share one node are not necessarily in series. A third wire at that connection can carry some of the current away. Likewise, two resistors drawn beside each other are parallel only if both node pairs match.

Follow a mixed circuit

A 12 V source feeds R₁, then the wiring splits through R₂ and R₃ before joining again on the return. Call the split node A and the rejoining node B. R₂ and R₃ both connect from A to B, so they are parallel. R₁ carries all the source current before it divides. It is in series with the whole parallel group, but it is not in series with either branch resistor alone.

Opening one branch stops current in that path. Opening the shared path through R₁ stops both branches because neither then has a complete route through the source.

Match quantities to the same part

Use voltage V, current I, resistance R, and power P. Many countries write U for voltage. For a resistor:

V=IR,P=VI=I2R=V2R

A component's voltage belongs with its own resistance and current. Whole-circuit values belong together too: total supply voltage divided by total equivalent resistance gives source current. Mixing a branch resistance with the whole supply voltage fails when another component takes part of the voltage.

Key Takeaways

  • Trace wires and label nodes before naming a connection.
  • Series components carry the same current; parallel components share both end nodes and the same voltage.
  • A branch is a path between nodes; a loop closes back on itself.
  • Apply Ohm’s law to matching voltage, current, and resistance values.

1.2 Current, voltage, and power in one path

In a series circuit, every component carries the same current. Charge cannot leave through another branch or build up steadily at a connection. A resistor transfers electrical energy into heat; it does not use up the current passing through it.

Find the shared current

Series resistances add because the source must drive current through every resistance along the path:

RT=R1+R2+R3+⋯ ,I=VSRT

The equivalent resistance is greater than any individual resistance in the string. Adding another series resistor to a fixed voltage supply therefore reduces the current everywhere.

Consider a 24 V supply connected to 100 Ω, 220 Ω, and 160 Ω in series. First find the resistance of the complete path:

RT=100+220+160=480 Ω

Then use the supply voltage with that total:

I=24480=0.050 A=50 mA

Dividing 24 V by 100 Ω would give 0.24 A, but the 100 Ω resistor does not have the entire supply across it. The other resistors also take voltage.

Calculate and check the voltage drops

Use the same 0.050 A for each resistor:

V1=0.050×100=5.0 V V2=0.050×220=11.0 V V3=0.050×160=8.0 V

Kirchhoff's voltage law, or KVL, says that the signed voltages around a closed loop add to zero. The source raises the potential by 24 V and the loads lower it by 5 V, 11 V, and 8 V:

24−5−11−8=0

Each coulomb receives energy at the source and gives it up in the loads. This is why the drops must account for the source voltage. The 220 Ω resistor takes the greatest drop because it offers the most resistance to the shared current. Equal current does not mean equal voltage.

Check component heating

For each resistor, use its own voltage and the series current, or use the current squared:

P1=0.0502×100=0.25 W

Similarly, the 220 Ω resistor dissipates 0.55 W and the 160 Ω resistor dissipates 0.40 W. Their total is 1.20 W, matching the source output:

PS=24×0.050=1.20 W

The greatest series resistance dissipates the most power because the current is fixed throughout the string. Choose each resistor's power rating above its calculated dissipation; a 0.5 W rating is too low for the 220 Ω resistor here.

Find a missing resistance

A separate 12 V circuit carries 0.20 A through a 40 Ω resistor and an unknown resistor. The complete path must be:

RT=120.20=60 Ω

Subtract the known 40 Ω to find 20 Ω. Its drop is 4 V; the 40 Ω resistor drops 8 V. Those drops add to 12 V. Finding the total first keeps the unknown component separate from the whole circuit.

Key Takeaways

  • Add series resistances before calculating the source current.
  • Current is the same throughout a series path; energy is transferred in each load.
  • The voltage drops around the loop add to the supply voltage.
  • At the same current, a larger resistance has a larger voltage drop and power dissipation.
  • Use a power rating above the calculated resistor dissipation.

1.3 Voltage dividers and series faults

Series resistors divide a supply voltage in proportion to their resistances. This lets a circuit produce a reference voltage or turn a sensor's resistance change into an output voltage. It also explains why bypassing one component can overload the others.

Take a share of the voltage

For one resistor in an unloaded series string:

Vn=VSRnRT

A 6 kΩ resistor and a 2 kΩ resistor on 12 V total 8 kΩ. The 2 kΩ resistor takes two eighths of the supply:

V2=1228=3 V

The 6 kΩ resistor takes the remaining 9 V. Their voltage ratio is 6:2, the same as their resistance ratio. In a thermistor divider, temperature changes one resistance and therefore changes the share of voltage at the junction.

The divider rule uses the same current through both resistors. Connecting a load across the output resistor adds another path. The load and output resistor form a parallel group; its resistance must be calculated before dividing the voltage.

Drop voltage for an LED

An LED's forward voltage is roughly constant over its working current. For an LED needing about 2.0 V at 20 mA from a 12 V supply, the series resistor must take 10 V:

R=12−2.00.020=500 Ω

A standard 510 Ω resistor gives about 19.6 mA. It dissipates about 0.20 W, so a 0.5 W resistor provides margin. The resistor calculation uses the voltage left after the LED's drop, not the whole 12 V.

Predict a break or bypass

Use a 24 V string of 100 Ω, 220 Ω, and 160 Ω. With all components working, the current is 50 mA.

FaultCurrent and voltage changes
The 220 Ω resistor opensCurrent becomes zero throughout; intact resistors drop 0 V; 24 V appears across the break
The 220 Ω resistor is shortedThe remaining 260 Ω carries about 92.3 mA; the bypassed resistor has 0 V across it

After the short, the 100 Ω resistor drops about 9.23 V and the 160 Ω resistor about 14.77 V. The 100 Ω resistor now dissipates about 0.85 W instead of 0.25 W. A zero voltage reading can therefore accompany either no current in an intact component or substantial current through a shorted part. Other readings distinguish the cases.

Series loads must share voltage correctly

A 12 V, 6 W lamp has a hot resistance of 24 Ω; a 12 V, 24 W lamp has a hot resistance of 6 Ω. Treating those values as fixed, the pair on 24 V carries 0.8 A. The lower-power lamp receives about 19.2 V and the higher-power lamp about 4.8 V. Actual filament resistance changes with temperature, so the figures are estimates; the lower-power lamp is at risk of overload.

Switches, fuses, and interlock contacts use series placement to control an entire current path. Opening any one of several series interlocks interrupts that path. Moving a resistor earlier or later in a string does not change its voltage share: resistance determines the share, not position.

Key Takeaways

  • An unloaded divider gives each resistor its resistance fraction of the supply voltage.
  • A load across the divider output changes the circuit into a mixed network.
  • A dropping resistor takes the supply voltage left after the device’s voltage drop.
  • An open series path stops all its current and puts the source voltage across the break.
  • A bypassed series resistor lowers total resistance and raises current and heating elsewhere.
  • Series placement lets a switch, fuse, or interlock interrupt the shared path.
2

Parallel loads and current sharing

Parallel connections let several loads operate from the same pair of supply points. Each branch can draw a different current, and the source must provide their combined demand. The shared voltage gives a direct route to branch current and power; the junctions provide a way to check the totals. Current sharing also explains why opening one load differs so much from shorting the supply nodes.

2.1 Branch currents and parallel resistance

Parallel branches connect across the same two nodes. Each branch therefore has the same voltage, even when their resistances differ. The current arriving at the split divides among the available conducting paths.

Calculate each branch first

If the branches connect directly across a 12 V source, use 12 V with each branch resistance. For parallel resistors of 6 Ω, 12 Ω, and 4 Ω:

I1=126=2 A,I2=1212=1 A,I3=124=3 A

Kirchhoff's current law, or KCL, says the total current entering a node equals the total leaving. Charge has no steady accumulation at the junction. The supply current is:

IT=2+1+3=6 A

The same 6 A returns after the branches rejoin. The smallest resistance carries the largest current, but current also flows through both other branches.

Replace the branches with one resistance

The equivalent resistance must draw that same total current at the same voltage:

RT=126=2 Ω

This is below the smallest branch value of 4 Ω. More paths make the whole group easier to drive. It would be wrong to add 6, 12, and 4 Ω: that would describe one path through all three resistors.

The general parallel formula is:

1RT=1R1+1R2+1R3+⋯

For the example, the reciprocal sum is 0.5 per ohm. Inverting that result gives 2 Ω. Stopping at 0.5 would confuse the group's conductance with its resistance.

Use a shortcut for two branches

For exactly two resistors, the reciprocal rule becomes:

RT=R1R2R1+R2

For 100 Ω and 150 Ω, the product is 15,000 Ω² and the sum is 250 Ω. Dividing gives 60 Ω, below 100 Ω as expected. To handle three resistors with this shortcut, replace a pair first, then combine that equivalent with the third. Multiplying all three and dividing by their sum is not the parallel rule.

For n equal parallel resistors of resistance R, the result is R divided by n. Four 80 Ω branches give 20 Ω. Each branch draws the same current because its voltage and resistance match the others; the supply carries four times one branch current.

Conductance describes the ease of current flow

Conductance is the reciprocal of resistance:

G=1R

Its unit is the siemens, S. Conductances add directly in parallel. A 4 Ω branch has 0.25 S; a 2 Ω branch has 0.50 S. Together they have 0.75 S, equivalent to about 1.33 Ω. Keep track of the unit when using a calculator: a value in siemens still needs inversion to become a resistance in ohms.

Key Takeaways

  • Parallel branches have equal voltage because they share both nodes.
  • Find branch current from the branch voltage divided by its resistance.
  • KCL makes total current the sum of the branch currents.
  • Parallel equivalent resistance is below the smallest positive branch resistance.
  • Invert the reciprocal sum to finish a parallel-resistance calculation.

2.2 Current sharing, power, and parallel faults

Each parallel load has its own current path. That makes it possible to switch one load without interrupting the others, while the shared supply conductor must carry the sum of their currents. Both branch calculations and supply ratings matter.

Divide a known total current

For two parallel resistances, current shares in inverse proportion to resistance:

I1=ITR2R1+R2,I2=ITR1R1+R2

The other branch's resistance goes in the numerator. A larger value of R₂ makes the R₁ path take more of the available total current.

For 30 mA entering 100 Ω in parallel with 150 Ω:

I100=30150250=18 mA I150=30100250=12 mA

Both give 1.8 V when current is multiplied by the branch resistance. The branch currents also add to 30 mA. Using the same branch's resistance on top would reverse the shares and fail the equal-voltage check.

Find power at the shared voltage

For a resistor in a parallel group:

Pn=V2Rn

At the same voltage, a smaller resistance dissipates more power. On 12 V, resistors of 6 Ω, 12 Ω, and 4 Ω dissipate 24 W, 12 W, and 36 W. Together they take 72 W, equal to 12 V multiplied by the 6 A supply current. This differs from series circuits, where the same current makes the largest resistance dissipate most power.

Add the demands on the shared conductor

A 24 V DC supply runs loads rated at 48 W, 96 W, and 120 W. Their currents are 2 A, 4 A, and 5 A. The shared conductor and its fuse carry 11 A, even though no single branch carries that much. This exceeds a 10 A fuse's rating; the rating alone does not specify the exact time at which it opens.

Adding a load in parallel lowers equivalent resistance and raises total current. With a stiff source and negligible wiring resistance, the existing branches keep their voltages and currents. A real battery or long cable can introduce a shared voltage drop when total current rises.

Distinguish an open branch from a short
FaultEffect on a parallel group supplied at fixed voltage
One branch opensIts current stops; the other branches keep working; total current falls
A conducting link shorts the group's two nodesThe link bypasses every load; very large current can flow in the shared supply path

In the 12 V group above, opening the 12 Ω branch removes its 1 A, so the total falls from 6 A to 5 A. The open branch still has the group voltage across its end nodes.

A short across the same two nodes bypasses the whole group. For a real source, internal and wiring resistance limit the resulting fault current, and the branch voltage collapses toward zero until protection operates. A short across a group inside a mixed network also changes voltage across the remaining series components.

Key Takeaways

  • For two parallel branches, the other resistance goes on top in the current divider rule.
  • The smallest parallel resistance draws the most current and dissipates the most power at the shared voltage.
  • Shared wiring and protection carry the total branch current.
  • An open branch removes its own current; a short across the group bypasses every branch.
3

Mixed networks and Kirchhoff’s laws

Mixed circuits need a clear record of what was combined and what each equivalent represents. Reduce valid groups to find source current, then restore those groups to find individual values. Kirchhoff’s laws connect the two directions of the calculation and handle unknowns that depend on polarity. They also show how a load on a divider or a fault in one branch can change values elsewhere.

3.1 Reducing mixed resistance networks

A mixed circuit becomes manageable when you replace one valid series or parallel group at a time. Each replacement must preserve the resistance seen at the group's two connection points. Keep the original drawing so you can later recover the individual component values.

Identify a group by its nodes

Label the connected wires before choosing a formula. Series resistors have no branching path at their shared connection. Parallel branches start and finish on the same two nodes. A series pair within one branch may need to be added before that branch can be combined with another.

After each replacement, redraw the remaining network and give the equivalent a clear name. For example, R₂₃ can represent the equivalent of R₂ and R₃. Keep that name distinct from either original resistor. Starting with a simple group far from the source often exposes the next group, but the electrical connections decide which reduction is valid.

Reduce a parallel group inside a series path

A 24 V source feeds R₁ = 4 Ω, then parallel resistors R₂ = 12 Ω and R₃ = 6 Ω, then R₄ = 2 Ω on the return. R₁ and R₄ both carry all the source current. First replace only the two resistors between the split and rejoining nodes:

R23=12×612+6=4 Ω

The reduced circuit has three series resistances: 4 Ω, 4 Ω, and 2 Ω. Add them:

RT=4+4+2=10 Ω

Now the source current follows from the complete equivalent:

IT=2410=2.4 A

The 4 Ω equivalent has the same voltage and total entering current as the original parallel pair. It does not mean both original branch resistors carry 2.4 A.

Reduce a series pair inside a parallel network

In a different network, 10 Ω and 20 Ω are in series in one branch. A 60 Ω resistor forms another branch across the same two end nodes. Add the resistors within the first branch:

R12=10+20=30 Ω

Then combine the complete branches:

RT=30×6030+60=20 Ω

Combining 20 Ω with 60 Ω first would be wrong. One end of the 20 Ω resistor is at the connection to the 10 Ω resistor, not at the supply node shared by the complete branches.

Check each replacement

A parallel equivalent must be smaller than its smallest positive branch resistance. A series equivalent must be greater than each positive resistance being added. Here, 20 Ω is below both complete branch resistances, 30 Ω and 60 Ω; it need not be below every individual resistor hidden inside those branches.

Some bridge networks have a resistor joining the middle of two branches. If that link prevents any valid series or parallel group, these replacement rules cannot complete the reduction. Kirchhoff equations then account for the interconnected currents. Do not force a pair into a series or parallel formula because it looks convenient on the page.

Key Takeaways

  • Replace only groups that pass the series or parallel node test.
  • Redraw and label each equivalent so every original resistor is counted once.
  • A series branch must be reduced before combining it with a parallel branch.
  • Check an equivalent against the complete groups being combined.

3.2 Recovering component values and loaded outputs

Equivalent resistance gives the current supplied to the whole circuit. To find what happens inside it, reverse the reductions. Restore each replaced group while keeping its terminal voltage and total entering current unchanged.

Work outward from the source current

Use the 24 V network with 4 Ω in series, then 12 Ω parallel with 6 Ω, then 2 Ω in series. Its total resistance is 10 Ω and its source current is 2.4 A. Both outside series resistors carry that current:

V1=2.4×4=9.6 V,V4=2.4×2=4.8 V

The parallel group has an equivalent of 4 Ω, so its voltage is:

V23=2.4×4=9.6 V

Restore the two branches. Each receives the group's 9.6 V:

I2=9.612=0.8 A,I3=9.66=1.6 A

The source's 24 V cannot be used across either branch because the outer series resistors take part of it.

Check current, voltage, and power

The branch currents add to 2.4 A, satisfying KCL. One complete source loop passes through R₁, either parallel branch, and R₄. Its drops are 9.6 V, 9.6 V, and 4.8 V, totaling 24 V. Do not add the two parallel drops into the same loop: the path goes through one branch or the other.

The resistor powers are 23.04 W, 7.68 W, 15.36 W, and 11.52 W. Their sum is 57.6 W, matching the source output of 24 V × 2.4 A. Count each physical resistor once in the power balance; counting the equivalent group as well would count the same power twice.

If the 6 Ω branch opens, the circuit becomes 4 Ω, 12 Ω, and 2 Ω in series. The total rises to 18 Ω and current falls to 1.333… A. Yet the 12 Ω resistor's voltage rises to 16 V. Less supply current does not mean every component receives less voltage: removing a parallel path changes the division.

Include a divider's load

A 12 V divider made of two 10 kΩ resistors gives 6 V with no load. Connect a 10 kΩ load across the lower resistor. The lower part becomes:

Rlower=10×1010+10=5 kΩ

The upper 10 kΩ is now in series with that 5 kΩ group. The output is:

Vout=12510+5=4 V

The upper resistor carries both the lower resistor current and the load current.

A 100 kΩ load instead gives a lower equivalent of about 9.09 kΩ and an output of about 5.71 V. Even a load ten times the lower resistor changes the output by about 5%. A much larger load resistance reduces this error. Reducing the divider resistances also helps, but increases the supply current. Carry unrounded intermediate values so small differences do not come from premature rounding.

Key Takeaways

  • Restore reduced groups in reverse order, keeping their terminal quantities.
  • Use the parallel group voltage to find each branch current.
  • Check KCL, a complete KVL loop, and the sum of physical resistor powers.
  • A fault in one branch can change voltages throughout a mixed network.
  • Combine a divider’s output resistor and load in parallel before calculating output voltage.

3.3 Signed currents and voltages

Kirchhoff's laws let you find a missing value without reducing an entire circuit. The signs record direction: current into or out of a node, and a rise or fall in voltage around a loop. Choose one convention and keep it through the equation.

Balance one node

Mark currents entering a node as positive and currents leaving as negative. If 5 A and 2 A enter while 3 A and an unknown current leave:

5+2−3−I=0

The unknown is 4 A outward. Add only currents meeting at that same node. A current elsewhere in the circuit belongs in a different node equation.

If the unknown direction is unclear, draw an arrow and solve using that direction. A result of −4 A means 4 A actually flows against the arrow. It is a useful direction result, not a reason to discard the calculation.

Walk around a loop

Choose a starting point and a direction, then follow one closed path. The signs depend on how you cross each component:

CrossingSigned voltage
Source from negative to positiveA rise, positive E
Source from positive to negativeA fall, negative E
Resistor along its current arrowA drop, negative IR
Resistor against its current arrowA rise, positive IR

Returning to the start returns to the same potential, so all signed terms sum to zero. Reversing the entire traversal reverses all signs and gives the same physical answer.

Combine sources with their polarities

A 12 V source and a 6 V source in series with 3 Ω can aid or oppose. With a rise through both sources:

12+6−3I=0,I=6 A

With a rise through the 12 V source and a fall through the 6 V source:

12−6−3I=0,I=2 A

In the opposing case, the 12 V source sets the current direction. Adding both voltages regardless of polarity would predict the wrong current.

Battery charging is an opposing-source calculation. A charger holds 14.0 V at its terminals and faces a battery EMF of 12.0 V. With battery internal resistance 0.1 Ω and lead resistance 0.4 Ω:

14.0−12.0−I(0.1+0.4)=0

Only the 2.0 V difference drives current through the combined 0.5 Ω, giving 4 A into the battery's positive terminal.

Use the laws as checks

For a 24 V loop with measured drops of 9.6 V and 4.8 V, the remaining drop must be 9.6 V. KVL accounts for energy around the chosen path; KCL accounts for charge at each junction. Equal series current and equal parallel voltage follow from these same laws.

When sources lie in several interconnected branches, several unknown currents may need simultaneous equations. For a single unknown, keep every source and resistor term visible with its sign. This prevents an opposing source from disappearing into an unsigned total.

Key Takeaways

  • At a node, incoming current equals outgoing current.
  • Mark an assumed current direction; a negative answer reverses it.
  • Crossing a source from negative to positive is a rise; following current through a resistor is a drop.
  • Aiding source voltages add; opposing source voltages subtract.
  • The charger–battery voltage difference drives charging current through the total loop resistance.
4

Real sources and cable losses

A working source and its cables have resistance as well as the intended load. Their voltage drops explain why a battery can look healthy without a load yet perform poorly when equipment starts. Cell arrangements change voltage and capacity in different ways, while conductor length, area, and temperature change cable losses. These calculations connect the circuit model with the voltage actually available at the equipment.

4.1 EMF, terminal voltage, and internal loss

A battery's printed voltage is a nominal value. The voltage available to a working load depends on the current and on resistance inside the source. Model a real source as an ideal EMF in series with an internal resistance.

Separate the two voltages

The electromotive force, E, is the energy supplied per coulomb, measured in volts. With no current, there is no internal drop, so open-circuit terminal voltage equals E in the model. During discharge:

I=ER+r,V=E−Ir

Here R is the external load and r the internal resistance. The term Ir is the lost volts. It is a voltage drop, not a quantity of energy; the internal heating power is current squared times internal resistance.

For E = 6.0 V, r = 0.5 Ω, and a 5.5 Ω load, the complete path is 6.0 Ω:

I=6.05.5+0.5=1.0 A

The source loses 0.5 V internally and supplies 5.5 V at its terminals. The load receives 5.5 W, while 0.5 W heats the source. The 6.0 W supplied by the ideal EMF accounts for both.

Estimate internal resistance from readings

Measure open-circuit voltage, then terminal voltage while the source delivers a known current:

r=E−VI

A battery reads 12.6 V open circuit and 12.2 V at 20 A. The 0.4 V change gives:

r=12.6−12.220=0.020 Ω

A normal open-circuit reading alone can miss a weak battery. Internal resistance commonly increases with age, discharge, and cold, so the voltage may fall much further when a load draws current. Compare the loaded reading with the load current, not just the label on the case.

Understand short-circuit current

With almost no external resistance, the model predicts:

Isc≈Er

For the 12.6 V battery and 0.020 Ω estimate, that is about 630 A before allowing for the connecting conductor and changes in the source. Such current can heat metal very quickly. Keep metal tools and jewelry away from battery terminals; never test short-circuit current by bridging the terminals.

A regulated supply can hold nearly constant terminal voltage as current changes, until it reaches its current limit. The small-resistance battery model describes voltage sag, but it does not replace the supply's current-limit behavior.

Maximum load power and efficiency

For a fixed EMF and internal resistance, maximum load power occurs when the load resistance equals r:

R=r,Pmax=E24r

With E = 6.0 V and r = 0.5 Ω, a 0.5 Ω load draws 6 A and receives 18 W. The source also dissipates 18 W internally. Half the generated power is lost, so maximum power transfer has only 50% efficiency. An efficient power supply instead has an internal resistance much smaller than the load, keeping internal heating and voltage sag low.

Key Takeaways

  • Use total resistance R + r to find the current from an EMF.
  • During discharge, terminal voltage is EMF minus the internal drop Ir.
  • Find internal resistance from voltage sag divided by load current.
  • A short can draw a very large current even from a low-voltage battery.
  • Maximum load power occurs at R = r, where half the generated power is lost inside the source.

4.2 Battery strings and parallel banks

Combining cells changes voltage, internal resistance, and charge capacity in different ways. Follow the polarity of every cell and distinguish ampere-hours, which measure charge capacity, from watt-hours, which measure energy.

Add cells in series

Connect the positive terminal of one cell to the negative of the next. Their EMFs and internal resistances add. For matching cells, the ampere-hour capacity remains that of one cell because the same current passes through every cell.

Four 1.5 V cells, each with 0.2 Ω internal resistance, form a 6.0 V source with 0.8 Ω internal resistance. On a 7.2 Ω load:

I=6.07.2+0.8=0.75 A

The terminal voltage is 5.4 V after subtracting the 0.6 V internal drop. Adding the EMFs while forgetting the internal resistances would overestimate both current and loaded terminal voltage.

A reversed cell subtracts its EMF. Three forward 1.5 V cells and one backward cell give 3.0 V. Reversing one cell reduces the total by twice its EMF: its contribution changes from +1.5 V to −1.5 V. Its internal resistance still adds to the series path.

Join identical sources in parallel

Parallel connections join positive to positive and negative to negative. Matching sources keep the voltage of one source, share the delivered current, and add their ampere-hour capacities. For n identical sources, the equivalent internal resistance is one source's r divided by n.

Three identical 12 V, 100 Ah batteries, each with 0.06 Ω internal resistance, give 12 V, 300 Ah, and 0.02 Ω. Their capacity to supply current increases without raising their EMF. The rated current available from a real bank also depends on the batteries and connections.

Match battery type, voltage, and state of charge before parallel connection. Unequal EMFs can drive current between sources even with no external load. Two sources at 12.8 V and 12.2 V, each with 0.05 Ω internal resistance, would drive:

I=12.8−12.20.05+0.05=6 A

The current circulates through both internal resistances. This wastes energy and heats the sources.

Combine strings into a pack

Sixteen cells of 3.2 V nominal in series give 51.2 V. Two matching strings in parallel keep 51.2 V and double the ampere-hour capacity. If each string has 100 Ah, the bank has 200 Ah; nominal energy is voltage multiplied by capacity, or 10,240 Wh. Series connection raises energy by raising voltage even though Ah stays unchanged.

Solar modules also add voltage in series and current in parallel at compatible operating points. Modules delivering 40 V and 10 A each give 160 V and 10 A in a four-module string. Two such strings give 160 V and 20 A, or 3200 W. All modules in a series string carry the same current, so shading one can limit the string; bypass diodes can provide a path around shaded sections.

Key Takeaways

  • Matching series cells add voltage and internal resistance while keeping one cell’s Ah capacity.
  • A reversed cell opposes the others but still adds internal resistance.
  • Identical parallel sources keep voltage, add Ah capacity, and reduce equivalent internal resistance.
  • Unequal parallel source voltages can drive circulating current without a load.
  • Series strings raise voltage; parallel strings raise capacity and available current.
  • Nominal energy in Wh equals voltage multiplied by Ah capacity.

4.3 Cable drop and conductor area

A supply cable is part of the current path. Its resistance takes some of the supply voltage and converts power into heat. This matters especially in low-voltage systems, where a modest loss in volts can be a large fraction of the supply.

Include both conductors

For a conductor:

R=ρLA

Resistivity ρ describes the material, L is conductor length, and A is cross-sectional area. With length in meters and area in mm², use ρ in Ω·mm²/m. At 20 °C, annealed copper is about 0.0172 Ω·mm²/m and aluminum about 0.028 Ω·mm²/m.

A load 10 m from its source has a 10 m outward conductor and a 10 m return conductor. The complete two-wire path is 20 m. For 2.5 mm² copper:

Rcable=0.0172×202.5=0.1376 Ω

At a design current of 10 A:

Vdrop=IRcable=1.376 V

On a 12 V supply the load receives about 10.6 V. The percentage drop is:

1.37612×100≈11.5%

The same 1.376 V is only about 0.6% of 230 V. This is why low-voltage installations often need comparatively large conductor areas.

Choose an area from a drop limit

For a two-wire route of length L, rearrange the resistance and voltage-drop equations:

A=ρ×2L×IVdrop,max

A 3% design limit on 12 V allows 0.36 V. With the same 10 m route and 10 A:

A=0.0172×20×100.36≈9.56 mm2

The next standard area is 10 mm². It drops about 0.34 V, or 2.9%. A 6 mm² cable would drop about 0.57 V, or 4.8%, and miss this limit. Common metric sizes include 1.5, 2.5, 4, 6, 10, 16, and 25 mm². Area is not diameter: a 2.5 mm² circular conductor is about 1.78 mm across.

IEC 60364-5-52 guidance gives 3% for lighting and 5% for other uses in installations fed directly from a public low-voltage network. NEC informational guidance recommends 3% for a branch circuit and 5% for feeder plus branch circuit. Use the design limit applicable to the installation. The chosen cable must also meet its current-carrying rating; passing the voltage-drop calculation alone does not establish the complete cable selection.

Allow for heat and temperature

Cable power loss is:

Ploss=I2Rcable

The 2.5 mm² path above loses about 13.8 W at 10 A. Doubling current doubles voltage drop and makes heating four times larger when resistance is unchanged.

Copper resistance increases by about 0.39% per °C. From 20 °C to 70 °C, the factor is about 1.20. A hot conductor therefore drops more voltage than a calculation using its 20 °C resistance. Published drop tables commonly use operating temperature. Check actual drop with the load running: subtract load voltage from supply-terminal voltage, or measure along the relevant conductor path.

Key Takeaways

  • Use the total outward-and-return conductor length in a two-wire DC circuit.
  • Voltage drop is IR; percentage drop uses the supply voltage as its denominator.
  • Round the required conductor area upward to an available standard size.
  • Check current rating separately from the voltage-drop requirement.
  • Cable loss is I²R and rises fourfold when current doubles at fixed resistance.
  • Higher copper temperature increases resistance and voltage drop.
5

Capacitors in DC circuits

Capacitors make a DC circuit change over time before it reaches a settled state. Charge and energy describe what a capacitor holds; connection rules determine the behavior of a group. A resistor controls how quickly the capacitor voltage changes, which makes timing and buffering possible. The same equations predict residual voltage after shutdown, while a meter checks the actual condition before contact.

5.1 Capacitance, stored energy, and combinations

A capacitor separates charge onto two conducting plates with an insulating dielectric between them. One plate gains positive charge and the other an equal negative charge. Energy is stored in the electric field; current is the movement of charge during charging or discharging.

Relate charge to voltage

Capacitance is charge stored per volt:

C=QV,Q=CV

Use farads for C, coulombs for Q, and volts for V. Practical capacitances are often in microfarads, nanofarads, or picofarads: 1 µF is 10⁻⁶ F, 1 nF is 10⁻⁹ F, and 1 pF is 10⁻¹² F. Larger plates, a thinner dielectric, or a dielectric with greater permittivity increase capacitance.

A 470 µF capacitor on 12 V stores:

Q=470×10−6×12=0.00564 C=5.64 mC

Its stored energy is:

W=12CV2=12×470×10−6×122≈0.0338 J

Doubling voltage doubles charge but quadruples energy for the same capacitance. The squared voltage in the energy formula is essential.

Combine capacitances
ConnectionEquivalent capacitanceWhat the capacitors share
ParallelAdd capacitancesThe same voltage
SeriesAdd reciprocals, then invertEqual charge magnitude for initially uncharged series capacitors

In parallel, 100 µF and 220 µF give 320 µF. Each is connected directly across the supply, so neither capacitor may have its working-voltage rating exceeded. The lowest voltage rating sets the group's limit.

In series:

CT=C1C2C1+C2=100×220100+220=68.75 μF

The result is below the smaller capacitance. These connection rules have the opposite pattern to the resistor rules.

Across 24 V, that initially uncharged series pair stores a charge magnitude of 1650 µC on each capacitor. Their voltages follow from charge divided by capacitance:

V100=1650100=16.5 V,V220=1650220=7.5 V

The smaller capacitance takes the larger voltage. Dividing 24 V equally would miss the different capacitances and could lead to exceeding a capacitor's rating.

Read a settled DC circuit

After charging has finished, an ideal capacitor carries no DC current; a real capacitor has a small leakage current. Treat the capacitor branch as open when finding settled resistor currents. A capacitor across the 2 kΩ resistor in a 12 V divider of 6 kΩ and 2 kΩ settles at 3 V. It takes the voltage of those two connection nodes, not necessarily the full supply.

Observe the working-voltage rating and the marked polarity of an electrolytic capacitor. Its positive terminal belongs at the more positive node. Reversed polarity or excessive voltage can cause overheating, venting, or bursting.

Key Takeaways

  • Charge is CV and stored energy is ½CV², with capacitance converted to farads.
  • Parallel capacitances add; series capacitances use the reciprocal rule.
  • In an initially uncharged series pair, equal charge gives the smaller capacitor the larger voltage.
  • A settled capacitor branch carries no ideal DC current but can retain a voltage.
  • Respect capacitor voltage ratings and electrolytic polarity.

5.2 Charging and discharging over time

A capacitor's voltage changes as charge moves onto or off its plates. A series resistor controls that current. The voltage changes quickly at first, then more slowly as the driving voltage across the resistor gets smaller.

Follow the start of charging

An initially uncharged capacitor has zero voltage. Immediately after connection to a DC source through R, the resistor takes the full supply voltage:

I0=VSR

As capacitor voltage rises, the resistor voltage falls because their drops must sum to the supply. Current then falls too. This is why charging is curved, not a straight rise at a constant rate.

The time constant gives the speed of the change:

τ=RC

Use ohms and farads to obtain seconds. For 10 kΩ and 470 µF:

τ=10 000×470×10−6=4.7 s

On 12 V, the initial current is 1.2 mA. After 4.7 s the capacitor has reached about 7.6 V. Doubling R or C doubles the time constant.

Use the charging curve

For charging from zero:

vC=VS(1−e−t/τ),i=I0e−t/τ
Elapsed timePercentage of final charging voltage
1τ63.2%
2τ86.5%
3τ95.0%
4τ98.2%
5τ99.3%

One time constant is not the full charging time. At 5τ, the capacitor is treated as practically full, although the ideal curve continues approaching the final voltage. In the example, 5τ is 23.5 s and the voltage is about 11.9 V.

Calculate discharge

Disconnect the supply and give the charged capacitor a resistor path. From an initial voltage V₀:

vC=V0e−t/τ

After one time constant, 36.8% remains. After five, about 0.67% remains. Charging's 63.2% is the amount gained toward a final value; discharge's 36.8% is the amount still left.

To find the time to a chosen remaining voltage:

t=τln⁡(V0vC)

A 1000 µF capacitor at 400 V discharging through 100 kΩ has a 100 s time constant. The calculated time to 50 V is about 208 s, or 3.5 minutes. The target is reached after about 2.08 time constants because the remaining voltage is one eighth of its initial value.

Apply the timing behavior

RC networks can delay an input until capacitor voltage reaches a switching level. A capacitor across a supply can deliver current during a short dip, and an RC input network can smooth the rapid changes caused by contact bounce.

Capacitors can remain charged after power is disconnected. Follow the manufacturer's discharge time and method, use a suitable discharge resistor, and confirm voltage is close to zero with a voltmeter before contact. Never discharge a capacitor by shorting it with a tool. Actual voltage verification is needed even when a calculated waiting time has passed.

Key Takeaways

  • The initial charging current is supply voltage divided by the series resistance.
  • Use R in ohms and C in farads to calculate τ in seconds.
  • Charging reaches 63.2% after τ and about 99.3% after 5τ.
  • Discharge leaves 36.8% after τ and follows an exponential decay.
  • Use the actual voltage check and manufacturer’s discharge procedure before contact.
6

Meter readings and fault finding

Calculations become more useful when they predict the readings at clear points in a circuit. Meter connections must match the quantity being measured, and the meter itself can alter a sensitive circuit. Comparing several readings helps distinguish tolerances from faults. Voltage, current, and resistance checks together can locate a broken path, a bypassed resistor, or a poor joint that heats under load.

6.1 Connecting a meter without changing the question

Voltage, current, and resistance require different meter connections. Before placing the probes, decide what quantity you want and predict its approximate value. The meter becomes part of the circuit, so its connection can also change the reading.

Measure voltage across two points

Select DC volts. Put the black lead in COM and the red lead in the V socket, then connect across the source or component in parallel. A negative reading means the red probe is at the lower potential. For example, −6.0 V has the same magnitude as +6.0 V with the probes reversed.

Choose a range above the expected voltage or use autoranging. Use a meter and leads rated for the circuit voltage and measurement category. An “OL” reading indicates an overrange value; on resistance it can indicate an open path.

Insert an ammeter in the path

To measure current, switch off, open the path, select DC current, and place the meter in the gap in series. Use the correct A or mA socket and check the expected current against the range and socket fuse rating before switching on.

An ammeter has very low resistance. Never connect it across a source: that makes a short circuit and can cause fuse failure, damage, or an arc. Return the red lead to the V socket after current measurement so the next voltage check does not create that fault.

A DC Hall-effect clamp meter measures current without opening the conductor. An AC-only clamp cannot measure a steady DC current.

Measure resistance with power removed

The resistance setting supplies its own small test current. Switch off, discharge capacitors, and disconnect at least one end of the resistor before measuring. Otherwise other connected paths can lower the reading. A 1 kΩ resistor with another 1 kΩ route across it reads 500 Ω in place, even when both resistors are correct.

Continuity testing also belongs on a de-energized circuit. A beep indicates a low-resistance path, useful when checking a conductor, fuse, or closed switch. It does not give a precise resistance value.

Allow for voltmeter loading

A digital voltmeter commonly has about 10 MΩ input resistance. Across a resistor, that input becomes a parallel path. For two 1 MΩ resistors dividing 10 V, the lower half becomes:

Rlower=1×101+10≈0.909 MΩ

The indicated lower voltage is:

V=100.90909…1+0.90909…≈4.76 V

The original unloaded value was 5 V. This difference is caused by the meter drawing current, even if its display is accurate. With 1 kΩ divider resistors, the same meter changes the reading by less than 0.01%.

An ammeter also introduces resistance through its shunt and leads. The resulting burden voltage is a small series drop. In a low-voltage, low-resistance circuit, it may reduce the current enough to matter. Treat loading and burden as circuit effects when comparing a prediction with a measurement.

Key Takeaways

  • A voltmeter connects across two points; an ammeter goes into the current path.
  • A negative DC voltage indicates reversed probe polarity.
  • Check current socket, range, and fuse before inserting an ammeter.
  • Measure resistance with power removed, capacitors discharged, and a component end disconnected.
  • A voltmeter loads high-resistance circuits; an ammeter adds a burden voltage.
  • A DC-capable clamp can measure steady current without opening the path.

6.2 Using readings to find the fault

A useful measurement tests a prediction. Calculate expected currents and voltage drops, measure the actual supply under load, then compare the readings as a connected set. Small differences can come from tolerances and the meter; a fault often produces a recognizable pattern across several measurements.

Allow for normal differences

A 220 Ω resistor with ±5% tolerance may be between 209 Ω and 231 Ω. The actual supply may also differ from its nominal value, and wiring adds resistance. Use the loaded supply voltage when predicting the circuit's working values.

For the 24 V series string of 100 Ω, 220 Ω, and 160 Ω, expected drops are 5 V, 11 V, and 8 V. Readings of 5.1 V, 10.8 V, and 8.1 V are close and total 24.0 V. Also compare current with the expected 50 mA: correct voltage proportions alone do not establish the correct total resistance. Doubling all three resistances preserves the division while halving the current.

Measured loop drops should total the measured source voltage, and branch currents should total source current within meter accuracy and resolution. Separate readings can load the circuit differently. For a larger mismatch, look for an omitted drop, an uncounted current path, a wrong range, or a connection error.

Read series-fault patterns

In a simple series circuit with one break, no current flows. Intact resistors then have no drop, while the supply appears across the break. On 24 V, readings of 0 V, 24 V, and 0 V across the three sections point to an open middle section or its connection.

A shorted resistor also has close to 0 V across it, but the rest of the pattern differs. Current still flows and is higher than expected; the remaining series resistors receive larger drops. A zero reading across one component is therefore insufficient on its own to choose between an open path elsewhere and a bypassed component.

Read parallel-fault patterns

An open branch can still show the full voltage across its end nodes. With a fixed source voltage, its current is zero while the other branches work normally. The source current falls by the missing branch current. Check branch current or test the de-energized branch when voltage readings look normal but its load does not run.

Find resistance where little should exist

A loose or corroded connection may pass current while wasting voltage and producing heat. Measure across the joint with the load operating. If a terminal drops 0.8 V at 10 A:

Rjoint=0.810=0.08 Ω Pjoint=0.8×10=8 W

Eight watts concentrated at a small terminal explains local heating. A sound connection at that current normally has a drop of only a few millivolts. An unloaded voltage check can miss the problem because the drop depends on current.

Apply the same difference method to a source or cable. Open-circuit voltage minus loaded terminal voltage gives internal source drop; divide by load current to estimate r. Loaded source-terminal voltage minus load-terminal voltage gives the cable drop. Keep these boundaries clear so a poor cable joint is not mistakenly blamed on the battery.

Key Takeaways

  • Use the actual loaded source voltage and allow for component and meter tolerances.
  • Compare both voltage division and current when checking a series string.
  • An open series section takes the supply voltage while current is zero.
  • A shorted series component has nearly zero voltage while current rises.
  • An open parallel branch can retain normal terminal voltage but carry no current.
  • A voltage drop across a loaded joint reveals unwanted resistance and local heating.

Series and Parallel Circuits examples

6 Walkthroughs

1

Follow one current path

14 steps
Read the connections, calculate a series string, then use voltage division to explain working loads and faults.
  1. 1
    IntroductionStart with the path

    A series circuit has one route through its components, so a break anywhere interrupts that route. Reading the connection correctly lets you use one current to calculate several different voltage drops.

    Follow a 24 V resistor string from its diagram to its operating values, then apply the same relationships to a divider, an LED resistor, and a fault.

  2. 2
    ExplanationRead the source and load symbols

    An IEC resistor is a rectangle; an ANSI resistor is a zigzag. A cell’s long line is positive and its short line negative. An IEC lamp is a circle with a cross; V and A mark meters.

    Conventional current leaves the source’s positive terminal, passes through the external loads, and returns to negative. Keep that direction when following arrows or reading meter polarity.

  3. 3
    TipMark the same wire with one node label

    All points joined by uninterrupted ideal wire belong to one node, even across bends. A branch runs between nodes; a loop returns to its start.

    Two resistors are parallel if both ends share the same two nodes. They are series if they share a connection with no other path branching from it. Components drawn side by side can have either connection: trace their endpoints.

  4. 4
    ChallengeDescribe the connections

    R₁ runs from A to B. R₂ and R₃ each run from B to C. A source connects from C back to A. How are the three resistors arranged?

    ---reveal---

    R₂ and R₃ are parallel because both connect B to C. R₁ is in series with the whole parallel group and carries its combined current. R₁ is not a series pair with R₂ alone, because the R₃ path branches off at B.

  5. 5
    ExplanationOne current, several drops

    In a series path, current leaving a resistor equals current entering it. The resistor transfers energy; it does not consume charge.

    Add series resistances before finding the shared current:

    RT=R1+R2+⋯ ,I=VS/RT

    Then use that current with each resistor’s own resistance to find its voltage drop. The largest resistance takes the largest drop.

  6. 6
    ExampleFind the current in the full string

    Connect 100 Ω, 220 Ω, and 160 Ω in series across 24 V. Their complete resistance is:

    RT=100+220+160=480 Ω

    The current is:

    I=24/480=0.050 A

    This 50 mA passes through every resistor. Dividing 24 V by only 100 Ω would treat that resistor as if it were alone across the source.

  7. 7
    ExampleAccount for the 24 V

    With the same 50 mA, multiply current by each resistance:

    V1=5 V,V2=11 V,V3=8 V

    The drops add to 24 V. Kirchhoff’s voltage law makes the signed loop sum zero:

    24−5−11−8=0

    The 220 Ω resistor takes most voltage because it has the greatest resistance, not because of its position in the string.

  8. 8
    ExampleCheck power before choosing ratings

    Use the shared 0.050 A with each resistance:

    P1=0.0502×100=0.25 W

    The other powers are 0.55 W and 0.40 W. They total 1.20 W, matching 24 V × 0.050 A from the source.

    A component’s power rating must exceed its dissipation. The 220 Ω resistor needs more than a 0.5 W rating because it dissipates 0.55 W.

  9. 9
    ChallengeRecover an unknown resistor

    A 10 V source drives 40 mA through 100 Ω and an unknown series resistor. Find the unknown resistance and its voltage drop.

    ---reveal---

    The whole path is 250 Ω because 10 V divided by 0.040 A gives 250 Ω. Subtract 100 Ω to get 150 Ω. Its drop is 6 V; the known resistor drops 4 V. The two drops account for the 10 V source.

  10. 10
    ExplanationTake a chosen voltage share

    A divider’s output is the voltage across its lower resistor. Without a load, use:

    V2=VSR2R1+R2

    A 6 kΩ upper resistor and 2 kΩ lower resistor across 12 V give 3 V at the output. A thermistor can replace one resistor so temperature changes this share. An attached load adds a parallel path and must be included in the calculation.

  11. 11
    ExampleLeave the LED its own drop

    A 2.0 V LED needs about 20 mA from 12 V. The resistor must take the remaining 10 V:

    R=(12−2.0)/0.020=500 Ω

    Choose the next standard value above it, 510 Ω. Current is about 19.6 mA and resistor power about 0.20 W, so a 0.5 W rating gives margin. Using 12 V for the resistor alone would miss the LED’s part of the voltage.

  12. 12
    Key InsightBreaks and bypasses leave different patterns

    A single open in a series string stops current everywhere. Intact resistors drop zero volts; the break takes the supply voltage.

    A short across one resistor bypasses it. Its drop is nearly zero while total resistance falls and current rises. The remaining resistors can overheat. A zero drop by itself therefore needs a current reading or other component voltages to explain it.

  13. 13
    ChallengePredict the effect of a bypass

    A 12 V source feeds 100 Ω and 200 Ω in series. A conducting link bypasses the 200 Ω resistor. What happens to current and the 100 Ω resistor’s power?

    ---reveal---

    Current rises from 40 mA to 120 mA because total resistance falls from 300 Ω to 100 Ω. Power in the remaining resistor rises from 0.16 W to 1.44 W. Tripling current multiplies its heating by nine, so a rating suitable before the fault may be inadequate afterward.

  14. 14
    RecapUse the same path for each calculation

    Recognize series and parallel from nodes, then pair each resistance with the voltage actually across it. In a series path, add resistances, find one current, and recover the individual drops and powers.

    Voltage division sets useful outputs, but a load or bypass changes the network. Fault predictions become stronger when voltage and current are considered together.

2

Share current between parallel loads

11 steps
Calculate each branch, check the source demand, and distinguish an open branch from a short across the group.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionOne voltage can supply several paths
  2. 2
    ExplanationBoth endpoints set branch voltage
  3. 3
    ExampleAdd the branch demands
  4. 4
    TipFinish the reciprocal calculation
  5. 5
    ChallengeFind a missing branch current
  6. 6
    ExplanationDivide a total between two branches
  7. 7
    ExampleCompare power at equal voltage
  8. 8
    ConnectionRate the shared path for every load
  9. 9
    Key InsightAn open removes a path; a short joins the nodes
  10. 10
    ChallengeCompare an added load with a broken branch
  11. 11
    RecapKeep branch and supply quantities distinct
3

Reduce a mixed network and work back

14 steps
Replace valid groups, recover component values, include divider loading, and use signed Kirchhoff equations.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionKeep a record of each replacement
  2. 2
    ExplanationChoose a group that really fits
  3. 3
    ExampleReplace the inner pair
  4. 4
    ChallengeReduce a complete branch
  5. 5
    ExampleRestore the outside drops
  6. 6
    ExampleRestore the branch currents
  7. 7
    TipCount power in the physical components
  8. 8
    ExamplePut the load into the divider
  9. 9
    ChallengeFind a loaded output
  10. 10
    ExplanationWrite directions before equations
  11. 11
    ExampleInclude the opposing battery
  12. 12
    ChallengeInterpret a negative current
  13. 13
    ChallengeRecalculate after a branch opens
  14. 14
    RecapUse both laws to test the reconstructed circuit
4

Find the voltage available at the load

17 steps
Model internal source resistance, combine cells, and calculate cable drop, heating, and required conductor area.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionFollow the losses before the load
  2. 2
    ExplanationSeparate EMF from terminal voltage
  3. 3
    ExampleAccount for internal heating
  4. 4
    ExampleUse sag to estimate internal resistance
  5. 5
    ChallengePredict another loaded reading
  6. 6
    Key InsightMaximum power can mean large internal loss
  7. 7
    ExplanationA series string adds voltage and resistance
  8. 8
    ExplanationA parallel bank adds capacity
  9. 9
    ConnectionBuild strings before combining them
  10. 10
    ChallengeCompare capacity with energy
  11. 11
    ExplanationCount the complete conductor path
  12. 12
    ExampleFind voltage drop at the design current
  13. 13
    ExampleCalculate a minimum area
  14. 14
    TipUse the right limit and operating temperature
  15. 15
    ChallengeInclude the return conductor
  16. 16
    ChallengeSeparate source sag from cable loss
  17. 17
    RecapChoose the boundary before taking a voltage difference
5

Calculate capacitor storage and timing

15 steps
Combine capacitances, find charge and energy, and follow RC charging and discharging to a chosen voltage.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionSeparate storage from charge flow
  2. 2
    ExplanationCharge sits on two insulated plates
  3. 3
    ExampleCalculate stored charge and energy
  4. 4
    ExplanationParallel adds capacitance
  5. 5
    ExampleSeries divides voltage unequally
  6. 6
    Key InsightThe settled capacitor can still have voltage
  7. 7
    ChallengeCheck the smaller capacitor’s rating
  8. 8
    ExplanationCharging starts with maximum current
  9. 9
    ExampleConvert prefixes before finding time
  10. 10
    ExplanationUse the correct exponential expression
  11. 11
    ExampleFind time to a remaining voltage
  12. 12
    TipVerify the voltage after shutdown
  13. 13
    ChallengePredict a discharge reading
  14. 14
    ChallengeChange the capacitance and the stored energy
  15. 15
    RecapUse storage equations and timing equations for different questions
6

Compare predicted values with meter readings

12 steps
Choose meter connections, allow for instrument effects, and use voltage and current patterns to find faults.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionPredict before probing
  2. 2
    ExplanationVoltage compares two potentials
  3. 3
    ExplanationCurrent requires a series connection
  4. 4
    TipRemove parallel paths for resistance
  5. 5
    ExampleThe voltmeter becomes a load
  6. 6
    ChallengeInterpret an in-circuit resistance
  7. 7
    ExplanationAllow for real component and meter values
  8. 8
    Key InsightZero volts needs a second clue
  9. 9
    ExampleMeasure a joint while it carries current
  10. 10
    ChallengeSeparate an open branch from a low supply
  11. 11
    ChallengeCheck which part of the path loses voltage
  12. 12
    RecapRead the measurements as one circuit

Series and Parallel Circuits practice questions

50 Practice Questions in 5 sets

Set 1: Connections and operating values10 Practice Questions

Question 1 of 10

A wire joins the lower ends of R₁ and R₂. A second wire joins their upper ends, with no components in either wire. How are R₁ and R₂ connected?
  1. In series with each other
  2. In parallel with each other
  3. In two separate open paths
  4. In series with the source
Show answerHide answer
Answer: B
Both resistors connect between the same pair of nodes, so they have the same voltage and are in parallel. Sharing one node alone would be insufficient, but the question gives a shared connection at both ends. Their positions on the drawing do not determine the connection.

Question 2 of 10

R₁ connects from node A to B, R₂ from B to C, and R₃ from A to C. No other connection meets B. How can the network between A and C be described?
  1. R₂ and R₃ in parallel, in series with R₁
  2. R₁ and R₃ in series, parallel with R₂
  3. R₁ and R₂ in parallel, in series with R₃
  4. R₁ and R₂ in series, parallel with R₃
Show answerHide answer
Answer: D
R₁ and R₂ share B with no branching there, so they form one series path from A to C. R₃ forms a second path between those same endpoints. R₂ and R₃ share only C, not both ends, so they cannot be treated as a parallel pair despite meeting at that node.

Question 3 of 10

An 8 Ω resistor and a 24 Ω resistor connect directly in parallel across 16 V. What current flows through the 24 Ω branch?
  1. 0.667 A
  2. 0.500 A
  3. 2.67 A
  4. 2.00 A
Show answerHide answer
Answer: A
The 24 Ω branch has the full 16 V across it, giving I=16/24≈0.667 A. The 2.00 A value belongs to the 8 Ω branch because that branch has a lower resistance. Adding the resistances before dividing would incorrectly treat the branches as one series path.

Question 4 of 10

A total of 40 mA enters two parallel resistors of 300 Ω and 100 Ω. How much current flows in the 100 Ω resistor?
  1. 10 mA
  2. 20 mA
  3. 30 mA
  4. 40 mA
Show answerHide answer
Answer: C
The 100 Ω branch takes three times the current of the 300 Ω branch because both have equal voltage. Dividing 40 mA in a 3:1 ratio gives 30 mA and 10 mA. Using the 100 Ω value in its own current-divider numerator would give 10 mA and reverse the shares.

Question 5 of 10

A 9 Ω resistor is in series with a parallel group of 18 Ω and 36 Ω. What equivalent resistance does the source see?
  1. 63 Ω
  2. 21 Ω
  3. 15 Ω
  4. 12 Ω
Show answerHide answer
Answer: B
The parallel group is 18×36/(18+36)=12 Ω, and the outside 9 Ω adds to give 21 Ω. The 12 Ω result represents only the parallel group. Adding all three resistances to get 63 Ω would ignore the split into separate current paths.

Question 6 of 10

A battery has an EMF of 9.0 V and internal resistance of 0.40 Ω. It supplies a 4.1 Ω load. What is its loaded terminal voltage?
  1. 8.12 V
  2. 9.00 V
  3. 8.20 V
  4. 0.80 V
Show answerHide answer
Answer: C
The total resistance is 4.5 Ω, so the load current is 2.0 A. The internal drop is 0.80 V, leaving 8.20 V at the terminals. Using 9.0 V as the loaded voltage would omit the internal resistance, while 0.80 V is the drop inside the battery rather than the load voltage.

Question 7 of 10

Three identical 2.0 V, 8 Ah cells are connected in series with aiding polarities. What are the nominal pack voltage and Ah capacity?
  1. 6.0 V and 8 Ah
  2. 2.0 V and 24 Ah
  3. 6.0 V and 24 Ah
  4. 2.0 V and 8 Ah
Show answerHide answer
Answer: A
Series EMFs add, giving 6.0 V, while the same current passes through all three cells and the capacity stays 8 Ah. Adding the Ah ratings to obtain 24 Ah would apply the parallel-capacity rule. The energy increases because the pack delivers its charge at a higher voltage.

Question 8 of 10

A 330 µF capacitor has 10 V across it. What charge magnitude is stored on either plate?
  1. 33.0 mC
  2. 0.330 mC
  3. 330 mC
  4. 3.30 mC
Show answerHide answer
Answer: D
Convert 330 µF to 0.000330 F and use Q=CV=0.000330×10=0.00330 C, or 3.30 mC. The 0.330 mC value misses the factor of 10 V. Capacitance is charge per volt, so multiplying by voltage is needed to obtain charge.

Question 9 of 10

A 22 kΩ resistor charges a 100 µF capacitor from zero on a 10 V supply. About what is the capacitor voltage after 2.2 s?
  1. 3.68 V
  2. 6.32 V
  3. 8.65 V
  4. 9.93 V
Show answerHide answer
Answer: B
The time constant is 22 000×100×10−6=2.2 s, so the elapsed time is one time constant. Charging from zero reaches about 63.2% of 10 V, or 6.32 V. The 3.68 V result is the fraction remaining during discharge, not the voltage gained during charging.

Question 10 of 10

Two 2 MΩ resistors form a divider across 12 V. A 6 MΩ voltmeter is connected across the lower resistor. By about what percentage does the meter reduce the unloaded output voltage?
  1. 16.7%
  2. 25.0%
  3. 14.3%
  4. 50.0%
Show answerHide answer
Answer: C
The unloaded output is 6 V; the meter makes the lower equivalent 1.5 MΩ and reduces output to about 5.14 V. The reduction relative to 6 V is about 14.3%. The lower resistance falls by 25%, but the output does not fall by that same percentage because the total divider resistance also changes.
Set 2: Voltage drops and circuit checks10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A 3.0 V LED is to run at no more than 15 mA from 9.0 V. Available series resistors are 330 Ω, 390 Ω, 430 Ω, and 470 Ω. What is the smallest suitable value?
  1. 390 Ω
  2. 330 Ω
  3. 470 Ω
  4. 430 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Three equal 90 Ω resistors are connected in parallel. What is their equivalent resistance?
  1. 30 Ω
  2. 45 Ω
  3. 90 Ω
  4. 270 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 20 V source feeds a 4 Ω resistor in series with a parallel pair of 12 Ω and 6 Ω. What voltage is across the 6 Ω resistor?
  1. 20.0 V
  2. 15.0 V
  3. 10.0 V
  4. 6.67 V
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

Currents of 1.8 A and 0.7 A enter a junction. A current of 0.9 A leaves through one wire. What current must leave through the only other wire?
  1. 0.2 A
  2. 1.6 A
  3. 2.5 A
  4. 3.4 A
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A two-wire copper circuit has a route length of 15 m and conductor area of 4 mm². It carries 8 A. Using ρ = 0.0172 Ω·mm²/m, what is the total cable voltage drop?
  1. 0.258 V
  2. 0.516 V
  3. 2.06 V
  4. 1.03 V
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Initially uncharged capacitors of 200 µF and 600 µF are connected in series across 16 V. What voltage is across the 200 µF capacitor after charging?
  1. 12 V
  2. 8 V
  3. 4 V
  4. 16 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 680 µF capacitor initially at 30 V discharges through 15 kΩ. About how long does it take to reach 6 V?
  1. 10.2 s
  2. 8.21 s
  3. 51.0 s
  4. 16.4 s
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A DC voltmeter reads −7.2 V with the black probe on point X and the red probe on point Y. How do the potentials of X and Y compare?
  1. Y is 7.2 V above X
  2. Y is 7.2 V below X
  3. X and Y have equal potential
  4. X is 14.4 V above Y
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

An ideal 18 V supply feeds three 100 Ω resistors in series. One resistor develops a fault. The source current is now 90 mA. What voltage pattern is expected across the three resistor positions?
  1. 6 V, 6 V, and 6 V
  2. 18 V, 0 V, and 0 V
  3. 9 V, 9 V, and 0 V
  4. 12 V, 3 V, and 3 V
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

An 18 V supply feeds 120 Ω, 180 Ω, and 300 Ω in series. What current flows through the 180 Ω resistor?
  1. 30 mA
  2. 100 mA
  3. 150 mA
  4. 50 mA
Show answerHide answer

Save this lesson to see this answer.

Set 3: Loads, losses, and changing conditions10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

An unloaded divider uses a 9 kΩ upper resistor and a 3 kΩ lower resistor across 20 V. What voltage is across the lower resistor?
  1. 5 V
  2. 15 V
  3. 10 V
  4. 6.67 V
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Three loads rated at 36 W, 60 W, and 84 W connect directly in parallel to a 12 V DC supply. What current flows in the shared supply wire?
  1. 7 A
  2. 5 A
  3. 10 A
  4. 15 A
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 5 Ω resistor is in series with two parallel branches. One branch contains 8 Ω and 16 Ω in series; the other contains 12 Ω. What is the total resistance?
  1. 17 Ω
  2. 13 Ω
  3. 29 Ω
  4. 9 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A 30 V divider has 6 kΩ above its output and 3 kΩ below. A 6 kΩ load is connected across the output. How much power does that load dissipate?
  1. 16.7 mW
  2. 37.5 mW
  3. 9.38 mW
  4. 75.0 mW
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A source reads 13.2 V open circuit and 12.6 V while delivering 15 A. What internal resistance does this model give?
  1. 0.040 Ω
  2. 0.840 Ω
  3. 0.880 Ω
  4. 0.020 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A 15 V source drives 25 mA through a 240 Ω resistor and an unknown resistor in series. What is the unknown resistance?
  1. 600 Ω
  2. 840 Ω
  3. 360 Ω
  4. 160 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 24 V load draws 6 A over a 20 m two-wire copper route. The design allows 4% cable drop. Using ρ = 0.0172 Ω·mm²/m and available areas 2.5, 4, 6, and 10 mm², what is the smallest area meeting the drop limit?
  1. 2.5 mm²
  2. 6 mm²
  3. 10 mm²
  4. 4 mm²
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 150 µF capacitor charged to 20 V is later charged to 40 V. What happens to its stored energy?
  1. It doubles
  2. It stays unchanged
  3. It becomes four times as large
  4. It becomes eight times as large
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A 470 Ω resistor has a tolerance of ±5%. What resistance interval meets that marking?
  1. 460.6–479.4 Ω
  2. 465.0–475.0 Ω
  3. 423.0–517.0 Ω
  4. 446.5–493.5 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

Six matching cells each have EMF 2.0 V, internal resistance 0.12 Ω, and capacity 10 Ah. They form two parallel strings of three series cells. What current does the pack supply to 2.82 Ω?
  1. 2.13 A
  2. 1.69 A
  3. 2.04 A
  4. 2.00 A
Show answerHide answer

Save this lesson to see this answer.

Set 4: Diagnosing networks and timing10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

An initially uncharged 220 µF capacitor charges through 47 kΩ from 12 V. An input switches when capacitor voltage reaches 9 V. About when does it switch?
  1. 7.17 s
  2. 10.3 s
  3. 14.3 s
  4. 51.7 s
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Two resistors initially share node B, with no other connection there. A third conducting branch is then connected from B to the return node. What can now be concluded about the first two resistors?
  1. They must carry equal current
  2. They can carry different currents
  3. They must have equal voltage
  4. They are now a parallel pair
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

Three positive resistances are in series. Their values are 82 Ω, 150 Ω, and 330 Ω. Which resistor dissipates the most power?
  1. The 330 Ω resistor
  2. The 82 Ω resistor
  3. The 150 Ω resistor
  4. All three dissipate equal power
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

Two resistors in parallel have a total conductance of 0.050 S. One is 50 Ω. What is the other resistance?
  1. 20.0 Ω
  2. 70.0 Ω
  3. 14.3 Ω
  4. 33.3 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

Across a 36 V source, one branch contains 4 Ω in series with an 8 Ω–8 Ω parallel pair. A second branch contains 24 Ω. What total current does the source deliver?
  1. 4.50 A
  2. 3.00 A
  3. 6.00 A
  4. 7.50 A
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

An ideal 16 V source opposes an ideal 10 V source in a closed loop with 2 Ω and 4 Ω resistors. What power is dissipated in the 4 Ω resistor?
  1. 4 W
  2. 16 W
  3. 6 W
  4. 12 W
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

Five matching 1.2 V cells are placed in series, but one is reversed. What is the string EMF?
  1. 6.0 V
  2. 4.8 V
  3. 2.4 V
  4. 3.6 V
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A copper cable has total out-and-back resistance 0.10 Ω at 20 °C. At 70 °C take its resistance as 1.20 times that value. A fixed 3.88 Ω load is supplied through it from an ideal 24 V source. What power heats the cable?
  1. 3.60 W
  2. 4.32 W
  3. 4.59 W
  4. 3.82 W
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A disconnected source is removed from a circuit before resistance testing. A 1.2 kΩ resistor remains connected in parallel with 3.6 kΩ. What resistance will a meter read across the pair?
  1. 0.90 kΩ
  2. 1.20 kΩ
  3. 2.40 kΩ
  4. 4.80 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A 12 V ideal source feeds a 2 Ω resistor, then two parallel branches of 6 Ω and 3 Ω. The 3 Ω branch opens. What happens to the current through the 6 Ω resistor?
  1. It falls from 1.0 A to 0.5 A
  2. It stays at 1.0 A
  3. It rises from 1.0 A to 1.5 A
  4. It rises from 1.0 A to 2.0 A
Show answerHide answer

Save this lesson to see this answer.

Set 5: Multistep circuit decisions10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A 2.4 V LED runs from 18 V through 820 Ω. Which available resistor rating is the smallest one above the calculated dissipation: 0.125 W, 0.25 W, 0.5 W, or 1 W?
  1. 0.25 W
  2. 0.5 W
  3. 0.125 W
  4. 1 W
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 15 Ω resistor and a 30 Ω resistor are connected in parallel across a fixed voltage. How does power in the 15 Ω resistor compare with power in the 30 Ω resistor?
  1. It is half as large
  2. It is four times as large
  3. It is the same
  4. It is twice as large
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

An unloaded 24 V divider has 4 kΩ above its output and 8 kΩ below. With a resistor load attached across the output, the output becomes 12 V. What is the load resistance?
  1. 8 kΩ
  2. 4 kΩ
  3. 12 kΩ
  4. 16 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A charger holds 28 V at its terminals against a battery EMF of 24 V. Battery internal resistance is 0.15 Ω and lead resistance is 0.25 Ω. What is the battery terminal voltage while charging?
  1. 24.0 V
  2. 28.0 V
  3. 25.5 V
  4. 26.5 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A source has a fixed EMF of 8.0 V and internal resistance of 2.0 Ω. What load resistance gives maximum load power, and what is that power?
  1. 4.0 Ω and 8.0 W
  2. 2.0 Ω and 8.0 W
  3. 2.0 Ω and 16 W
  4. 4.0 Ω and 16 W
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Initially uncharged capacitors of 100 µF and 300 µF, each rated 16 V, are connected in series across 24 V. What is the result after charging in the ideal circuit model?
  1. Both are within rating at 12 V each
  2. The 300 µF exceeds rating at 18 V
  3. Both are within rating at 8 V and 16 V
  4. The 100 µF exceeds rating at 18 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

An initially uncharged capacitor C charges through 10 kΩ from 20 V. It reaches 10 V after 3.47 s. About what is C?
  1. 501 µF
  2. 347 µF
  3. 250 µF
  4. 694 µF
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 1.0 Ω load is driven by an ideal 3.0 V source. Inserting an ammeter adds 0.20 Ω in series. What current does the meter measure?
  1. 3.0 A
  2. 3.6 A
  3. 2.4 A
  4. 2.5 A
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A source reads 25.0 V open circuit. Under load it reads 24.0 V at its terminals and 22.5 V at the load, with current 5.0 A. What are the source internal resistance and total cable resistance?
  1. 0.50 Ω and 0.30 Ω
  2. 0.20 Ω and 0.50 Ω
  3. 0.20 Ω and 0.30 Ω
  4. 0.30 Ω and 0.20 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A 12 V two-wire copper circuit carries a specified design current of 4 A over a 12 m route. Use ρ = 0.0172 Ω·mm²/m and a hot-resistance factor of 1.20. With a 3% drop limit, what is the smallest suitable area from 2.5, 4, 6, and 10 mm²?
  1. 4 mm²
  2. 6 mm²
  3. 2.5 mm²
  4. 10 mm²
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

71 Key Terms, each with its definition

A

Aiding sources
Aiding sources are series sources whose polarities produce voltage rises in the same loop direction, so their EMFs add.
The two aiding sources supply a net 18 V when the 12 V and 6 V rises are added around the loop.
Ampere-hour
An ampere-hour is a unit of charge capacity equal to 3600 coulombs, commonly used to rate the charge a battery can deliver.
A 20 ampere-hour capacity stays 20 Ah when matching cells are placed in a single series string.
Assumed current direction
An assumed current direction is a chosen arrow used to write equations before the actual direction is known from the solution.
A negative result reverses the assumed current direction without changing the calculated magnitude.

B

Battery string
A battery string is a series-connected group of cells or batteries whose voltages add while all members carry the same current.
A second matching battery string in parallel raises the bank’s capacity without raising its voltage.
Bleeder resistor
A bleeder resistor provides a discharge path for stored capacitor charge, reducing voltage over time after the supply is removed.
The bleeder resistor sets the discharge time constant together with the power supply’s capacitance.
Branch
A branch is a path between two circuit nodes that contains one or more components and carries the current through that path.
The lamp branch can be opened by its switch while another parallel branch remains complete.
Branch current
A branch current is the current through one path of a parallel network, determined by that path’s voltage and resistance.
The branch current in the 6 Ω resistor is twice that in a 12 Ω resistor across the same nodes.
Bridge network
A bridge network has linked branches, often with a component across their middle points, that can prevent simple series-parallel reduction.
The middle link in the bridge network means the adjacent resistors are not a simple series pair.
Burden voltage
A burden voltage is the voltage drop introduced by an ammeter’s current-measuring path, which can reduce current in the circuit.
The ammeter’s burden voltage matters when a low-voltage source drives a load of very small resistance.

C

Capacitance
Capacitance is the charge magnitude stored per volt across a capacitor, measured in farads and calculated as charge divided by voltage.
A larger capacitance stores more charge at the same voltage in the supply’s buffer capacitor.
Cell
A cell is one electrochemical source with its own EMF and internal resistance; several cells can be combined into a battery.
Four cells connected with aiding polarities make a higher-voltage series battery for the instrument.
Circuit diagram
A circuit diagram uses standard symbols and lines to show electrical connections, independent of the equipment’s physical layout.
The technician follows the circuit diagram to trace a complete return path through the control switch.
Circuit reduction
Circuit reduction replaces a valid series or parallel group by its equivalent resistance while preserving its terminal behavior.
Circuit reduction turns two equal parallel resistors into one value before an outside series resistor is added.
Circulating current
A circulating current flows between connected sources because their EMFs differ, even when no external load takes current.
Unequal parallel battery voltages drive circulating current through both batteries’ internal resistances.
Conductance
Conductance is the reciprocal of resistance and describes how readily a path carries current; parallel conductances add directly.
The technician adds branch conductance values before inverting the total to find resistance.
Continuity test
A continuity test checks for a low-resistance path, often with a beep, in a de-energized circuit such as a wire or closed switch.
The continuity test stays silent across the blown fuse because its internal conducting path is broken.
Conventional current
Conventional current is charge flow described in the direction positive charge would move, from positive to negative externally.
The conventional current arrow points from the battery’s positive terminal toward the resistor.
Cross-sectional area
Cross-sectional area is the conductor area perpendicular to current flow; a larger area gives lower resistance at fixed length and material.
A 6 mm² cross-sectional area names the copper area, not a conductor diameter of 6 mm.
Current divider
A current divider is a parallel network that shares total current among branches in inverse proportion to their resistances.
A current divider sends more current through a smaller branch resistor than a larger one while keeping equal branch voltage.

D

DC clamp meter
A DC clamp meter senses steady current magnetically around a conductor, using a DC-capable sensor without opening the current path.
The DC clamp meter reads the battery lead current while the load remains connected and operating.
Dielectric
A dielectric is the insulating material between capacitor plates that supports the electric field while separating the conductors.
A thinner dielectric increases capacitance when the plate area and dielectric material remain unchanged.
Dropping resistor
A dropping resistor is a series resistor chosen to take excess supply voltage at a device’s intended operating current.
The LED’s dropping resistor takes the voltage left after subtracting the LED’s forward drop.

E

Electromotive force
Electromotive force is the energy supplied per unit charge by a source, measured in volts and represented by E in the source model.
The battery’s electromotive force is estimated from its voltage with the external load disconnected.
Equivalent resistance
Equivalent resistance is the resistance of a single replacement that draws the same total current at the same terminal voltage.
In a circuit of three series resistors, their equivalent resistance is used to calculate the source current.
Exponential decay
An exponential decay reduces a quantity by the same fraction in each equal time interval, as in an RC capacitor discharge.
Exponential decay leaves about 36.8% of the capacitor voltage after each additional time constant.

F

Farad
A farad is the SI unit of capacitance, equal to one coulomb of stored charge magnitude per volt across the capacitor.
The technician converts 470 microfarads to 0.000470 farad before calculating stored energy.

H

High-resistance joint
A high-resistance joint is a connection with unwanted resistance that causes a voltage drop and local heating when load current flows.
The technician finds a high-resistance joint by measuring voltage directly across the terminal under load.

I

Initial charging current
The initial charging current is the current just after an uncharged capacitor is connected through a resistor to a DC source.
The initial charging current is 1.2 mA when 12 V is applied through a 10 kΩ series resistor.
Input resistance
The input resistance is the resistance a voltmeter presents between its probes, creating a parallel load on the measured circuit.
A 10 MΩ input resistance noticeably loads a divider made with megohm resistors but barely affects kilohm values.
Internal resistance
Internal resistance is the resistance inside a real source model that causes voltage loss and heating when current passes through it.
Increased internal resistance makes the aging battery’s terminal voltage sag when the load starts.

K

Kirchhoff’s current law
Kirchhoff’s current law states that total current entering a circuit node equals total current leaving, expressing charge balance.
Kirchhoff’s current law checks the supply reading against the sum of the measured branch currents.
Kirchhoff’s voltage law
Kirchhoff’s voltage law states that the signed voltage changes around a closed circuit loop add to zero, expressing energy balance.
Kirchhoff’s voltage law checks that three measured drops in a series loop account for the source voltage.

L

Leakage current
A leakage current is a small current through a real capacitor’s imperfect insulation after the ideal charging current has settled.
The small leakage current explains why a real charged capacitor is not a perfectly open DC branch.
Loaded voltage divider
A loaded voltage divider has an output load in parallel with one divider resistor, changing the resistance and the output voltage.
In a loaded voltage divider, the attached load lowers the lower-side equivalent resistance and with it the output voltage.
Loop
A loop is a closed path through a circuit that returns to its starting point and can be used to balance signed voltage changes.
A loop through the source and one parallel load contains the full source rise and that load’s drop.
Lost volts
Lost volts is the internal voltage drop Ir while a source supplies current, reducing its terminal voltage below the EMF.
At 2 A through 0.1 Ω internal resistance, the lost volts amount to 0.2 V inside the source.

M

Maximum power transfer
Maximum power transfer is the fixed-source condition where load resistance equals internal resistance and load power is greatest.
Maximum power transfer gives only 50% efficiency because the internal resistance dissipates equal power.
Meter accuracy
Meter accuracy describes how close a reading can be to the true quantity within the instrument’s stated error allowance.
Meter accuracy is considered when the measured loop drops differ slightly from the supply reading.
Mixed circuit
A mixed circuit contains both series and parallel connections, so its equivalent resistance usually needs more than one reduction.
A mixed circuit results when a shared resistor comes before the current divides between two separate loads.

N

Node
A node is a set of circuit points joined by uninterrupted ideal wire, so all those points have the same electrical potential.
Two resistor leads joined by ideal wire share one node even when a long wire separates them on a circuit drawing.

O

Open circuit
An open circuit is a broken conducting path that prevents current through that path, even though voltage can remain across the break.
An open circuit in one series interlock stops current through the complete control string.
Opposing sources
Opposing sources are sources whose polarities drive current in opposite loop directions, so their EMFs subtract in the loop equation.
The opposing sources in the charging loop leave only their voltage difference to drive current.
Output voltage
An output voltage is the potential difference supplied between a circuit’s output terminals, measured relative to the chosen return.
The divider’s output voltage falls when a lower-resistance load is connected across its output.
Overcurrent
An overcurrent is a current above the rating or allowable value for part of a circuit, which can cause excessive heating.
Adding several parallel loads can produce overcurrent in wiring that carries their combined demand.

P

Parallel connection
A parallel connection places components or complete branches across the same two nodes, giving them the same terminal voltage.
A parallel connection lets the indicator and buzzer each receive the control supply voltage.
Parallel load
A parallel load is a load connected across the same two nodes as another load, allowing it to operate on the shared voltage.
Switching off one parallel load removes its current without opening the other load’s path.
Percentage voltage drop
Percentage voltage drop is the cable voltage drop divided by supply voltage and multiplied by 100, showing its relative size.
The same drop in volts gives a larger percentage voltage drop on a 12 V system than on a 24 V system.
Polarized capacitor
A polarized capacitor has a required terminal polarity; connecting it in reverse can damage the component and cause overheating.
The positive lead of the polarized capacitor is connected to the more positive output node.
Power balance
A power balance compares power delivered by sources with power absorbed by components, accounting for every physical component once.
For a circuit of four resistors, the power balance matches their four powers with the voltage times current at the supply.
Power rating
A power rating states the power a component is designed to dissipate under specified operating conditions without overheating.
A resistor calculated to dissipate 0.55 W exceeds its 0.5 W power rating, so a higher rating is needed.

R

Resistivity
Resistivity is a material property relating conductor resistance to length and cross-sectional area, with a value that depends on temperature.
Copper resistivity at 20 °C is used with the total conductor length to estimate the cable resistance.
Resolution
Resolution is the smallest change that an instrument display can distinguish on its selected measurement range.
The meter’s resolution can make separately rounded branch readings sum slightly differently from the total.
Route length
The route length is the one-way distance between source and load, which must be doubled for equal outward and return conductors.
A route length of 10 m gives 20 m of conductor in the complete two-wire DC current path.

S

Series branch
A series branch is one path between two nodes containing components with no intermediate branching, so they share that path’s current.
The resistances in a series branch must be added before that branch is combined with a resistor in parallel with it.
Series connection
A series connection joins components along one current path with no branching at their shared connection, giving them equal current.
A series connection places the switch in the lamp’s current path so opening it turns the lamp off.
Short circuit
A short circuit is a very low-resistance path that bypasses part of a circuit and can cause excessive current in the remaining path.
A short circuit across one resistor in a series string leaves nearly zero voltage across that resistor.
Shunt
A shunt is the low-resistance element in an ammeter that produces a measurable voltage drop related to the current passing through it.
The shunt adds a small resistance in series with the branch while the meter measures current.
Siemens
A siemens is the SI unit of conductance, equal to one reciprocal ohm or one ampere of current per volt across a conducting path.
A path with a conductance of half a siemens has a resistance of two ohms.
Sign convention
A sign convention is a consistent rule for assigning positive and negative directions to currents or voltage changes in equations.
The loop sign convention makes a source crossing from negative to positive a positive voltage rise.
Significant figures
Significant figures are the meaningful digits used to report a value; retaining extra intermediate digits limits rounding error.
The final voltage is reported to three significant figures after the unrounded current is used.
Steady state
A steady state is the settled operating condition after transients have died away; an ideal capacitor then carries no constant DC current.
In steady state, the capacitor across the lower divider resistor has the divider’s output voltage.

T

Temperature coefficient
A temperature coefficient describes the fractional change in resistance per degree near a reference temperature for a material.
Copper’s temperature coefficient predicts roughly 20% more resistance at 70 °C than at 20 °C.
Terminal voltage
Terminal voltage is the potential difference across a source’s external terminals, which differs from EMF when internal current causes a drop.
The terminal voltage is measured directly at the battery posts while the equipment draws current.
Thermistor
A thermistor is a resistor whose resistance changes with temperature, allowing a divider to convert temperature into an output voltage.
A thermistor in the divider changes the sensor output as the equipment temperature changes.
Time constant
A time constant is the product RC in seconds, setting the speed of a capacitor’s exponential charging or discharging through resistance.
One time constant brings the initially uncharged capacitor to about 63.2% of the fixed supply voltage.
Tolerance
A tolerance is the allowed variation of a component’s actual value from its nominal value, commonly specified as a percentage.
A 220 Ω resistor with 5% tolerance may measure 209 Ω while still matching its marked specification.
Total current
The total current is the current supplied to a whole network; for parallel branches it equals the sum of their individual currents.
A fuse in the shared conductor feeding a radio, lamp, and fan carries the total current of all three.

V

Voltage divider
A voltage divider uses series resistances to produce an output that is a chosen fraction of the voltage applied across the string.
With no output load attached, a voltage divider built to give 3 V provides that 3 V across its lower resistor.
Voltage drop
A voltage drop is a decrease in potential along a component in the current direction, associated with energy transferred per unit charge.
The voltage drop across a larger series resistor accounts for a greater share of the supply than the drop across a smaller one.

W

Watt-hour
A watt-hour is an energy unit equal to 3600 joules; nominal battery energy is voltage multiplied by ampere-hour capacity.
The 24 V, 50 Ah pack has a nominal 1200 watt-hour energy capacity before allowing for losses.
Working voltage
A working voltage is the maximum voltage a capacitor is rated to withstand under its specified operating conditions.
A parallel capacitor receives the full supply, so that voltage must stay within its working voltage rating.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started