Electrical Quantities and Ohm’s Law
BeginnerLesson 1 of 7 in Electrical Principles for Technicians Course
What you will learn
- Write every electrical value with the correct quantity, unit and prefix, and explain what charge, current and voltage mean in a working circuit.
- Write and convert values with SI units and prefixesName the symbol and SI unit of each electrical quantity, convert between prefixes and powers of ten, and get values into base units before calculating.
- Explain charge and current and calculate with Q = ItDescribe current as a flow of charge, use the coulomb, ampere and ampere-hour, and calculate charge, current or time.
- Explain voltage and the types of electrical supplyDefine voltage as energy per unit charge, distinguish emf from potential difference, measure voltage across a component and tell DC and AC supplies apart.
- Write and convert values with SI units and prefixes
- Explain resistance and Ohm’s law, find voltage, current or resistance from measurements and calculations, and use the law to explain open circuits, short circuits and poor connections.
- Explain resistance and Ohm’s law from measurementsDefine resistance as the ratio of voltage to current, investigate the relation between voltage and current by measuring, and tell ohmic from non-ohmic components.
- Calculate voltage, current and resistance with V = IRChoose and rearrange the right form of Ohm’s law, handle prefixes, and use proportional reasoning to predict how current changes.
- Use Ohm’s law to explain open circuits, short circuits and poor connectionsPredict currents and voltages when a circuit is broken, shorted or has a high-resistance connection, and read voltage and resistance measurements in that light.
- Explain resistance and Ohm’s law from measurements
- Explain how material, length, cross-section and temperature set a conductor’s resistance, and calculate cable resistance and voltage drop with resistivity.
- Explain how material, length, area and temperature affect resistanceRelate a conductor’s resistance to its length, cross-sectional area and material through resistivity, and describe how temperature changes it.
- Calculate conductor resistance and cable voltage drop with R = ρL/AUse and rearrange R = ρL/A with consistent units, include both conductors of a cable run, and work out the voltage lost along a cable.
- Explain how material, length, area and temperature affect resistance
- Calculate the power of loads with the power formulas, explain the heating effect of current in conductors and connections, and use efficiency to link electrical input to useful output.
- Calculate electrical power with P = VI, I²R and V²/RDefine power as the rate of energy transfer, choose the power formula that fits the known values, and read the power and voltage on a rating plate.
- Explain the heating effect of current in conductors and connectionsUse P = I²R to explain heating in elements, cables, connections and fuses, and why cable size must match the current.
- Calculate efficiency and link electrical and mechanical powerCalculate efficiency and losses, distinguish a motor’s input and output power, and calculate mechanical power from force, distance and time.
- Calculate electrical power with P = VI, I²R and V²/R
- Calculate the energy appliances and machines use in joules and kilowatt-hours, and turn it into running costs, bills and savings.
- Calculate energy in joules and kilowatt-hoursUse W = Pt with the right units, convert between joules and kilowatt-hours, and read energy use from meter readings and usage patterns.
- Calculate and compare electricity costsTurn energy use into cost with a price per kWh, work out bills with fixed charges and time-of-use prices, and compare running costs, savings and payback.
- Calculate energy in joules and kilowatt-hours
Ohm’s Law study guide
1Read units and explain electrical quantities
A reading of 12 V and a reading of 12 A tell you very different things. Units identify what has been measured, while prefixes make very large and very small values easier to handle. Charge, current and voltage then explain what happens in a circuit: charge moves, current measures its rate of flow, and voltage describes the energy transferred by each coulomb. These meanings guide both calculations and the way meters connect.
1.1 Use electrical symbols and convert prefixes
A value combines a number with a unit. In “4.7 kΩ,” the prefix k means one thousand, so the resistance is 4,700 ohms.
Match the quantity to its unit
| Quantity | Quantity symbol | Unit | Unit symbol |
|---|---|---|---|
| Charge | Q | coulomb | C |
| Current | I | ampere | A |
| Voltage | V, also U | volt | V |
| Resistance | R | ohm | Ω |
| Power | P | watt | W |
| Energy or work | W, also E | joule | J |
| Time | t | second | s |
A symbol's position tells you its job. In “V = 12 V,” the first V names voltage; the last V names volts. W can name work in a formula, but W after a number means watts. Many IEC and European texts use U for voltage, giving for the same relationship as .
The ampere, second, meter and kilogram are SI base units. Electrical derived units connect to them: a coulomb is an ampere-second, a volt is a joule per coulomb, an ohm is a volt per ampere, and a watt is a joule per second.
Replace a prefix with a power of ten
| Prefix | Symbol | Factor |
|---|---|---|
| pico | p | |
| nano | n | |
| micro | μ | |
| milli | m | |
| kilo | k | |
| mega | M | |
| giga | G |
Case matters: m is milli, M is mega, and kilo uses lowercase k. For 250 mA, replace milli with :
Similarly, 35 μA is , 2.2 MΩ is , and 1.5 kW is 1,500 W. Converting the other way, 0.0068 A is 6.8 mA.
Scientific notation gives one nonzero digit before the decimal point. Engineering notation uses exponents that are multiples of three: 0.00047 A is or , which is 470 μA. Enter “4.7 EXP 3” to obtain 4,700 on a calculator; “4.7 × 10 EXP 3” adds an unwanted factor of ten.
Keep the units consistent in a calculation
A 20 mA current through 330 Ω gives:
Using 20 without converting would make the voltage one thousand times too large. Base units are a reliable route. Compatible prefixes can also cancel: 2 mA through 4.7 kΩ gives 9.4 V because .
An area needs the length conversion twice:
Thus 2.5 mm² is . Use m² with resistivity in Ω·m; use mm² directly with resistivity in Ω·mm²/m. Write a space between a value and its unit, as in “12 V.” Keep full calculator precision during working, then round the final answer, usually to three significant figures.
Key Takeaways
- A prefix changes the value by its stated power of ten; upper and lower case matter.
- Quantity symbols and unit symbols can use the same letter for different jobs.
- Base units make substitution reliable; compatible prefix factors can also cancel.
- An area of 1 mm² equals .
- Keep full precision until the final answer and include its unit.
1.2 Follow charge through a circuit
Charge is a property of particles. Electrons carry negative charge and protons carry positive charge. A current tells you how quickly charge passes a chosen point in a circuit.
Count charge per second
The coulomb (C) measures charge. One electron carries approximately . About electrons therefore carry −1 C, whose magnitude is 1 C. In circuit calculations, the amount of charge passing is usually written as a positive magnitude.
Current is charge divided by elapsed time:
One ampere means one coulomb passes each second. In copper or aluminum, free electrons move through the metal. In an electrolyte, such as battery acid, moving ions carry current.
Suppose a current of 2.5 A flows for 4 minutes. First convert the time:
Then multiply the rate by the time:
That is a charge magnitude equal to about electrons. Using the number 4 as though it were seconds would give only 10 C. The time unit must match the ampere's meaning of coulombs per second.
To find current, 90 C passing in 30 s gives . To find time, delivering 120 C at 0.4 A takes , or 5 minutes.
Read battery capacity in ampere-hours
An ampere-hour is another unit of charge:
A 2 Ah battery represents 7,200 C of charge capacity. At a steady 0.5 A, its ideal running time is . High currents and low temperatures can reduce the usable capacity. Ah alone does not state energy; the battery voltage matters too.
Keep direction separate from energy transfer
Conventional current runs from the positive terminal through the external circuit to the negative terminal. Electrons in the metal drift in the opposite direction. Circuit arrows use conventional current, so there is no need to reverse an arrow to make it follow electrons.
Charge circulates around a closed path. A load transfers energy from the circuit, but does not use up current. In one closed loop, the current entering the load equals the current leaving it. Opening a switch breaks that path and stops the current throughout the loop.
Copper and aluminum conduct easily because they have many mobile electrons. PVC, rubber, glass and dry wood act as insulators, separating or covering conducting parts. The current's size depends on the load: an indicator LED commonly takes 10–20 mA; a phone charger's low-voltage output may be 1–3 A; a 230 V kettle draws roughly 9–13 A.
Put an ammeter in the path
An ammeter connects in series, so the current being measured passes through it. Its resistance is very low. Across a supply it would create a near short circuit, potentially blowing its fuse or damaging the meter. A voltage measurement needs a different connection.
Key Takeaways
- Current is charge passing per second: .
- Use seconds when calculating coulombs from amperes.
- One ampere-hour equals 3,600 C.
- Conventional current and electron drift have opposite directions in a metal.
- A load transfers energy; the current is not used up.
- An ammeter connects in series.
1.3 Understand voltage and DC or AC supplies
Voltage describes the energy transferred by each coulomb moving between two points. It can be present even when the circuit is open and no current flows. A disconnected battery still has voltage between its terminals.
Connect voltage, charge and energy
Potential difference, often shortened to p.d., is:
One volt means one joule per coulomb. A 9 V battery moving 2 C transfers . If a lamp receives 54 J while 6 C passes, the voltage across it is . A larger voltage gives more energy transfer for the same amount of charge.
Voltage always compares two points. A quoted “voltage at a point” uses an implied reference such as 0 V or earth. Say “current through the load” and “voltage across the load”; voltage itself does not flow.
A source's electromotive force, or emf, is the energy it supplies per coulomb by converting chemical, mechanical or light energy. Potential difference across a load describes energy transferred from electrical form. Both are measured in volts. A real source's internal resistance makes its terminal voltage lower than its emf while it supplies current.
Compare the two points with a voltmeter
Connect a voltmeter in parallel, with one lead at each end of the component. Its high resistance lets it compare the points while drawing very little current. An ideal voltmeter has infinite resistance. In series, a real voltmeter greatly reduces the loop current, so the load may stop and the meter can read nearly the whole supply voltage.
Tell supply types apart
| Supply | What the polarity does | Examples |
|---|---|---|
| DC | Keeps the same polarity | Cells, batteries, solar panels, DC power supplies |
| AC | Reverses repeatedly | Public mains supplies |
A 1.5 V cell, a 12 V vehicle battery and an 18 V tool battery are familiar DC sources. Public mains examples include 230 V at 50 Hz in much of Europe and 120 V at 60 Hz in the United States and Canada. Frequency in hertz counts complete cycles each second.
The stated AC voltage is an rms value, short for root mean square. A 230 V rms AC supply produces the same average heating in a fixed resistor as 230 V DC. This lets you use rms voltage and current in Ohm's law and the power formulas for resistive loads. Motors and other loads with coils require further AC relationships to calculate their input from voltage and current.
Read voltage-band names correctly
IEC-based terminology places extra-low voltage at up to 50 V AC rms or 120 V ripple-free DC. Low voltage is above those limits and extends up to 1,000 V AC or 1,500 V DC. Household mains belongs to the low-voltage band. That technical name describes a band, not freedom from shock danger: household mains can be fatal.
Key Takeaways
- Voltage is energy transferred per coulomb between two points.
- Emf describes energy supplied per coulomb; it is measured in volts.
- A voltmeter connects in parallel and has high resistance.
- DC keeps its polarity; AC reverses polarity.
- Rms AC values give the equivalent heating effect in a fixed resistor.
2Use resistance and Ohm’s law
Resistance links the voltage across a component to the current through it. Measurements show when that link stays proportional and when heating or component behavior changes it. From there, you can choose the right form of Ohm’s law, handle prefixes, and check the result. The same reasoning explains why a broken path stops current, a short circuit drives a large current, and a poor connection can become hot.
2.1 Find resistance from measurements
Resistance describes how much voltage is needed to drive a given current. Its unit is the ohm (Ω). A component has a resistance of 1 Ω at an operating point if 1 V across it produces 1 A through it.
Calculate the voltage-to-current ratio
At the same voltage, a larger resistance carries less current. Conductance describes the ease of conducting and is the reciprocal:
Its unit is the siemens (S). A 50 Ω component has a conductance of . Resistance and conductance describe the same component from opposite directions, but are different quantities.
In a metal, drifting electrons interact with vibrating atoms. Energy transfers to the metal as heat. Raising the metal's temperature usually makes these interactions stronger, increasing its resistance.
Test whether resistance stays constant
Ohm's law states that current through a metallic conductor at constant temperature is directly proportional to the voltage across it. Its resistance stays constant:
To investigate, use a variable DC supply, an ammeter in series with the component, and a voltmeter across it. Record several voltage–current pairs. Calculate the ratio for each pair or plot current vertically against voltage horizontally.
| Voltage | Current | Resistance |
|---|---|---|
| 2 V | 0.10 A | 20 Ω |
| 4 V | 0.20 A | 20 Ω |
| 6 V | 0.30 A | 20 Ω |
| 8 V | 0.40 A | 20 Ω |
Every ratio is 20 Ω. Doubling voltage doubles current, so these readings show ohmic behavior. The current–voltage plot is a straight line through the origin. Its slope is ; a steeper current–voltage line means lower resistance. A voltage–current graph with its axes reversed has slope R instead.
Recognize a changing resistance
The ratio gives resistance at a particular operating point even for a non-ohmic component. What fails is carrying that same resistance to a different point without checking it.
A filament lamp heats as current increases. At 6 V and 1.2 A its resistance is . At 12 V and 1.75 A it is about 6.9 Ω. Doubling voltage did not double current because the hotter filament had more resistance. Its current–voltage curve bends toward the voltage axis. The cold filament's lower resistance also explains its high switch-on current.
A diode mainly conducts in one direction. A thermistor changes resistance strongly with temperature; a light-dependent resistor decreases resistance as illumination increases. Even a fixed resistor may drift during measurements if it warms, so low-current or quick readings help keep temperature steady.
Allow for manufacturing tolerance
A stated resistance is a nominal value. A 4.7 kΩ resistor with ±5% tolerance permits a difference of either way. Its allowed range is therefore 4,465–4,935 Ω. A measured value within that range meets the stated tolerance.
Key Takeaways
- Resistance is voltage divided by current at the same operating point.
- Ohm’s law adds that resistance stays constant as voltage changes at constant temperature.
- A straight current–voltage line through the origin has slope .
- A hot filament has more resistance than a cold filament.
- Tolerance gives an allowed range around a nominal resistance.
2.2 Choose the right form of Ohm’s law
Start with the quantity you need, then choose the equation that leaves it alone on one side. The three forms of Ohm's law are rearrangements of one relationship, not three separate rules.
Match the equation to the unknown
| Find | Equation | Calculation |
|---|---|---|
| Voltage | Current × resistance | |
| Current | Voltage ÷ resistance | |
| Resistance | Voltage ÷ current |
Dividing both sides of by I leaves . This explains why the resistance formula is voltage divided by current. Reversing that ratio gives conductance instead.
A triangle with V above I and R is a useful memory aid. Cover V to see multiplication; cover I or R to see a division with V on top. The equation still needs the correct units and the readings for the same component.
Work a current calculation
A heating element with a working resistance of 46 Ω is connected across 230 V. The known values are voltage and resistance, so:
Check by multiplying back: 5 A through 46 Ω needs 230 V. For a 4.7 kΩ resistor across 12 V, convert resistance to 4,700 Ω first:
The larger resistance on the smaller voltage gives a much smaller current, which supports the size of the answer.
Find voltage or resistance
A current of 20 mA through 330 Ω requires:
For 2 mA through 4.7 kΩ, the prefixes cancel, giving 9.4 V directly. If unsure about prefix combinations, convert to amperes and ohms before multiplying.
A load draws 30 mA from 9 V. Convert the current to 0.030 A:
Dividing by 30 would give 0.3 Ω, one thousand times too small. A quick reverse check exposes it: 0.3 Ω on 9 V would carry 30 A, not 30 mA.
Predict a change before calculating
For a fixed resistance, voltage and current change in the same proportion. The 46 Ω element draws 2.5 A at 115 V because the voltage has halved. For fixed voltage, doubling resistance halves current. If both change, apply both factors: doubling voltage while tripling resistance makes the current of its former value.
These predictions rely on resistance staying fixed. A lamp whose filament temperature changes cannot use its cold resistance to predict its hot current. You can still calculate its resistance from a voltage and current measured together at the operating point.
Always pair the voltage across a component with the current through that component. A load directly connected to a supply receives approximately its supply voltage; the connecting leads can account for a small difference. A cable's own resistance must be paired with the voltage lost along that cable, not the full supply voltage.
Key Takeaways
- Use , or to isolate the required quantity.
- Convert prefixes before substitution and check with the original equation.
- At fixed resistance, current changes in proportion to voltage.
- At fixed voltage, current changes inversely with resistance.
- Use voltage and current for the same component.
- A non-ohmic component’s resistance belongs to its operating point.
2.3 Explain breaks, shorts and poor connections
A circuit that stops working can have very different electrical faults. The effect depends on whether the path is broken, bypasses the load, or still conducts through an unwanted resistance.
Compare an open circuit with a short circuit
| Fault | Path | Current in the simple loop |
|---|---|---|
| Open circuit | Broken | Zero |
| Short circuit | Very low resistance bypasses the load | Can become extremely large |
| Poor connection | Conducts through unwanted contact resistance | May continue, with local voltage loss and heating |
An open switch, broken conductor or blown fuse opens the path. In the ideal single loop, the break acts like infinite resistance. With no current, the intact load has no voltage drop, while the full supply voltage appears across the break. An open switch in a 230 V lamp loop can therefore have about 230 V across it while the lamp has 0 V.
A short creates a path of very low resistance. At 230 V, a total fault-path resistance of 0.5 Ω gives:
The resistance of the source, cables and fault path limits the current. A real short has small resistance, not a mathematical zero that allows division by zero. The source voltage has not simply vanished everywhere.
An overload leaves current flowing through a load, but the current exceeds what the circuit was designed to carry. Too much connected equipment or a jammed machine can cause it. A short-circuit current is often far larger; an overload can heat a cable more slowly. A protective device's disconnection time depends on the size of the excess current and its design.
Follow the voltage lost at a bad joint
A loose or corroded contact adds resistance at a small point in the path. If 16 A flows through 0.1 Ω:
That is energy transferred at the joint instead of being delivered to the load. Heating concentrated at the contact can damage terminals and insulation even though the circuit still works.
A sound closed switch or good joint has very low resistance, so its voltage drop under load is almost zero. Nearly the full supply voltage across a supposedly closed switch, fuse or joint suggests a break or a very high resistance at that location. A voltage reading must be interpreted with the circuit's operating state: a zero reading across a sound conductor does not mean the supply is absent.
Interpret a resistance reading
An ohmmeter sends a small test current from its own battery. Near 0 Ω indicates continuity through a low-resistance path. “OL” means the resistance exceeds the selected range; an open circuit is one possible reason. It is not a reading of zero resistance.
Measure resistance only with the circuit isolated from its supply and the component disconnected as required. Make live measurements only when trained and authorized, using a meter and leads rated for the circuit.
Key Takeaways
- An open path stops loop current, but voltage can remain across the break.
- A short circuit provides a very low-resistance path and can drive a large current.
- An overload still sends current through a load.
- A poor contact can lose voltage and concentrate heat.
- An ohmmeter’s “OL” display means over range, not zero ohms.
3Calculate cable resistance and voltage drop
A cable is a conductor with a length, cross-sectional area, material and operating temperature. Each of these helps set its resistance. The supply-to-load distance is only part of the current’s journey in a two-wire circuit: the return conductor matters too. Combining conductor resistance with the load current lets you calculate voltage lost in the cable and judge how a change of length or area affects delivery.
3.1 Relate resistance to material, size and temperature
Two pieces of wire can have different resistances even when they are made from the same metal. Material sets resistivity; the wire's dimensions and temperature turn that material property into the resistance of a particular piece.
Separate material from shape
Resistance increases in proportion to length and decreases in proportion to cross-sectional area. Double a wire's length at the same temperature and its resistance doubles. Double its area and resistance halves. A larger area provides more conducting paths side by side.
Resistivity, written ρ (rho), describes a material at a specified temperature. It can be understood as the resistance between opposite faces of a 1 m cube. Its SI unit is the ohm-meter, Ω·m. Resistance in ohms belongs to a piece; resistivity belongs to its material.
| Material at 20 °C | Approximate resistivity in Ω·m |
|---|---|
| Silver | |
| Annealed copper | |
| Conductor-grade aluminum | |
| Nichrome |
Glass and PVC have resistivities around or greater. Material grade and purity change published values, so use the resistivity supplied for a calculation.
Installers often express resistivity in Ω·mm²/m. This matches conductor areas in mm² without converting them to m². The conversion is:
Copper's value is therefore 0.0172 Ω·mm²/m, and conductor-grade aluminum is about 0.028 Ω·mm²/m. Copper combines low resistivity with useful bending and joining properties. Aluminum is lighter for a given resistance, making it useful for large cables and overhead lines. Nichrome's higher resistivity and resistance to oxidation at high temperature suit heating elements.
Distinguish diameter from area
Doubling the diameter does more than double the conducting area. For a circular cross-section:
Area increases with diameter squared. Doubling diameter gives four times the area and, for the same material, length and temperature, one quarter of the resistance. This is why a diameter ratio cannot be used directly as an area ratio.
Allow for warmer metal
Metals have a positive temperature coefficient: their resistance rises as they warm. For a moderate change from 20 °C:
Here T is the temperature in °C and α for copper is about 0.00393 per °C. A 10.0 Ω winding warming from 20 °C to 70 °C has a temperature increase of 50 °C:
Its resistance is about 12.0 Ω, nearly 20% above the cold value. Use the temperature rise of 50, not the final temperature 70, inside the correction. NTC thermistors behave differently: their resistance falls with rising temperature. Alloys such as constantan change relatively little.
Key Takeaways
- Resistance rises with length and falls with cross-sectional area.
- Resistivity describes a material at a stated temperature.
- Copper is about 0.0172 Ω·mm²/m at 20 °C.
- Doubling wire diameter gives four times the area and one quarter of the resistance.
- A metal’s temperature correction uses its change from the reference temperature.
3.2 Include the return path in cable calculations
A conductor's resistance follows from resistivity, length and area. Before entering numbers, decide which length carries current and which area unit matches the resistivity.
Set up a consistent calculation
With ρ in Ω·m, use L in m and A in m². With ρ in Ω·mm²/m, use m and mm². Mixing Ω·m with an area left in mm² makes resistance one million times too small.
A load is 20 m from its source. In a two-wire DC circuit, current travels 20 m out and 20 m back. Both conductors contribute resistance, so total L is 40 m. For 2.5 mm² copper at 20 °C:
Using SI area gives the same result:
Using only the source-to-load distance would halve the answer. If a task already gives total conductor length, use that length directly without doubling it again.
Start from diameter, length or a resistance limit
For wire of diameter 1.38 mm:
The division by four matters because the circle formula uses radius, which is half the diameter. Keep the unrounded area if another calculation follows.
A nichrome wire of 0.20 mm² area must have a resistance of 22 Ω. With resistivity :
For 50 m of copper limited to 0.5 Ω, the minimum calculated area is:
Among sizes 1.5, 2.5, 4, 6, 10 and 16 mm², the next size up is 2.5 mm² for this resistance requirement. Choosing the nearer 1.5 mm² would exceed the maximum resistance.
Turn cable resistance into voltage drop
At a known current:
The 0.2752 Ω cable carrying 16 A loses . From a 230 V source, the load receives about 225.6 V. As a percentage of supply voltage:
IEC-based guidance gives typical limits of 3% for lighting and 5% for other loads supplied from the public network; national requirements can differ.
Ratios help compare alternatives. For the same material and temperature, changing from 100 m of 1.5 mm² wire to 50 m of 2.5 mm² wire multiplies resistance by . The new resistance is 0.344 Ω. A warmer cable has more resistance, so its voltage drop at the same current is larger than its 20 °C value.
Key Takeaways
- Use Ω·m with m², or Ω·mm²/m with mm².
- Include outgoing and return conductors when both carry the load current.
- Calculate circular area from .
- Rearrange the conductor formula to find a required length or minimum area.
- Cable voltage drop is current times total cable resistance.
- Calculate a percentage drop using the supply voltage as the denominator.
4Calculate power, heating and useful output
Power describes how fast energy is transferred. In a load, that transfer can provide useful heat or mechanical work; in a cable or loose joint, it becomes unwanted heating. The right power formula depends on the quantities known and on what stays fixed. Efficiency then connects electrical input to useful output, including the extra input needed to run a motor and the losses through several machine stages.
4.1 Choose and use an electrical power formula
A watt is one joule transferred each second. A 2,000 W heater transfers energy twenty times as fast as a 100 W load while both are operating. Power is a rate, so it does not yet tell you the total energy used.
Connect the power formulas
Voltage is joules per coulomb and current is coulombs per second. Multiplying them cancels coulombs, leaving joules per second, or watts. For a resistive load, substitute Ohm's law to obtain:
Choose the form that uses the known values. If current and resistance are given, square the current. If voltage and resistance are given, square voltage and divide by resistance. The voltage must be across the resistance and the current must pass through that same resistance. DC values apply directly; for resistive AC loads use rms values.
Read a rating plate
A plate marked “230 V ~ 2000 W” describes a 2,000 W AC load at 230 V. For a heater at that operating point:
Its element resistance is:
Using unrounded current and resistance in returns 2,000 W. For a 1,500 W heater at 120 V, current is 12.5 A and resistance is 9.6 Ω. The lower-voltage heater draws more current for its stated power.
A 3 kW heater at 230 V needs about 13.0 A. Load current is a starting value for circuit design: the protective-device rating must suit the load, and the cable's permitted current must suit the device and installation conditions.
Predict power when voltage changes
For a fixed resistance, power is proportional to voltage squared. If the 230 V heater operates at 207 V with resistance treated as unchanged:
Voltage has fallen to 90%, but power has fallen to 81%. Current also falls. Keeping the rated power fixed and calculating a rising current would describe a different kind of load behavior, not this fixed resistor.
Check the power of a small resistor
A 330 Ω resistor carrying 20 mA dissipates:
A 0.25 W rating exceeds that calculated dissipation. The stated component rating applies under its specified operating conditions. Entering 20 as amperes before squaring would make the answer a million times too large: the conversion factor for milliamperes is squared along with the current.
The resistance of a short cable section is small, but the full supply voltage is not across that section in normal operation. Putting supply voltage into with only cable resistance would predict a short-circuit condition instead of the cable's actual heating. Use the current through the cable in or its measured voltage drop in .
Key Takeaways
- Power is energy transferred per second, measured in watts.
- Use , or with values for the same resistance.
- A rating plate gives power at the rated operating conditions.
- At fixed resistance, power changes with voltage squared.
- Convert current to amperes before squaring it.
4.2 Explain heat in cables and contacts
Resistance converts electrical energy into heat whenever current flows. The same effect heats a kettle element, warms a supply cable and can damage a loose terminal. Whether that heat is useful depends on where it is produced and where it can escape.
Follow the square of current
Joule heating occurs at the rate:
For a resistance of 0.1 Ω, 8 A produces . At 16 A, it produces . Doubling current gives four times the heating in the same resistance. This rapid increase explains why a modest overload can matter thermally.
In a copper cable run with total resistance 0.2752 Ω, 16 A produces about 70.5 W along the conductors. Keeping length and current the same but increasing conductor area from 2.5 to 4 mm² reduces resistance to 0.172 Ω and heating to about 44.0 W. More area lowers resistance and reduces loss at a given current.
Distinguish total heat from a hot spot
A cable spreads its heat along its length. A poor connection can produce tens of watts in a tiny contact area. That concentrated heat can discolor a terminal, soften insulation and worsen the connection. A thermal camera can reveal a local hot spot even while the load continues running.
Current alone therefore does not describe every heating problem. Two paths carrying 16 A can have different losses because their resistances differ. A damaged high-resistance joint can overheat without the load current exceeding the protective device's rating.
Include heat escaping to the surroundings
A conductor's final temperature depends on both heat produced and heat released. Cables surrounded by thermal insulation, grouped with other cables or installed in hot spaces cool less effectively. Their permitted current is lower. Standard PVC cable insulation commonly has a 70 °C conductor temperature limit; the applicable cable data and installation conditions determine the rating.
A cable reel still wound on its drum traps heat. This is why its coiled-load rating is lower than its fully unwound rating. As a metal warms, its resistance rises; at unchanged current, that increases its heating further.
Understand protective heating effects
A fuse element melts when excess current lasts long enough, breaking the path. A typical circuit breaker has a thermal bimetal response for overloads and a magnetic response to very large short-circuit currents. The response depends on both the current's size and duration.
Ask what stays fixed
“More resistance gives more heat” needs a fixed quantity. At the same current, a larger resistance dissipates more power through . At the same voltage, a larger resistance reduces current and dissipates less power through . At 230 V, 26.5 Ω produces about 2,000 W, while 53 Ω produces about 1,000 W. Always identify whether current or voltage is being held constant before predicting the change.
Key Takeaways
- Joule heating rises with current squared for a fixed resistance.
- A larger conductor area reduces cable loss at the same current.
- Contact resistance concentrates heat in a small area.
- Cable temperature depends on cooling as well as electrical loss.
- A fuse opens through heating; a typical breaker responds to overloads and shorts.
- The effect of changing resistance depends on whether current or voltage stays fixed.
4.3 Connect electrical input to useful mechanical power
A machine's useful output is smaller than its input because some energy transfers to unwanted forms. A motor loses energy through winding resistance, heating in its iron core, bearing friction, fan air resistance and sound.
Calculate efficiency and loss
Using efficiency as a decimal:
Multiply the ratio by 100% to express efficiency as a percentage. A motor taking 2.5 kW and delivering 2.0 kW has efficiency and loses 0.5 kW, or 500 W. Compare powers in the same units. An answer above 100% for these machines means the values, units or calculation need checking.
To find the required input, rearrange:
Enter 85% as 0.85 in this equation. Dividing by 85 would make the input one hundred times too small.
Read a motor rating as output
A motor's rated kW normally describes useful mechanical power at its shaft. A 2.2 kW saw motor at 85% efficiency needs:
For a DC motor delivering 270 W at 75% efficiency, input is . On an 18 V supply, its input current is . Using output directly in the current calculation would miss the power lost inside the motor.
Find mechanical output from a lift
Mechanical work is force times distance moved in the force's direction:
For steady speed, . Use newtons for force, meters for distance, seconds for time and meters per second for speed. For a lifted mass, weight is with .
A hoist lifts 50 kg through 6 m in 10 s. The weight is . Work is , so useful power is . If electrical input is 420 W, efficiency is . Mass is not force: entering 50 as newtons would omit gravity.
Follow power through several stages
Each stage passes on only a fraction of the power it receives. A motor with 85% efficiency driving a gearbox with 90% efficiency has overall efficiency:
For every 1,000 W entering the motor, 850 W reaches the gearbox and 765 W leaves it. The gearbox's 10% loss acts on its 850 W input. Adding or averaging the percentages misses this changing input. For the same useful output and operating time, a more efficient machine needs less input energy and costs less to run.
Key Takeaways
- Efficiency is useful output divided by input; losses are input minus useful output.
- Use decimal efficiency when calculating input from output.
- A motor’s rated shaft power is its mechanical output.
- Mechanical work is force times distance; power is work divided by time.
- A lifted mass has weight in newtons.
- Multiply stage efficiencies to find overall efficiency.
5Work out energy use and running costs
An appliance’s power tells you its rate of use; its running time tells you how much energy it consumes. Meter readings and kilowatt-hours connect that energy to a bill. Some loads cycle on and off, and some machines state useful output instead of electrical input. Accounting for those details lets you compare running costs, include fixed charges and decide how long a more efficient purchase takes to repay its extra cost.
5.1 Calculate joules and kilowatt-hours
Energy adds up while a load runs. A high-power load for a short time can use less energy than a small load left on for many hours. Keep power and elapsed operating time separate until you multiply them.
Choose the energy unit first
With power in watts and time in seconds, energy is in joules. For an electrical load this can also be written . A 60 W lamp on for one minute uses .
With power in kilowatts and time in hours, the product is kilowatt-hours:
Meters use kWh because joules give very large numbers for daily energy use. The h multiplies kW; “kW/h” divides by time and is not energy.
A 2 kW heater on for 3 h uses . Converting to megajoules gives . To convert joules to kWh, divide by 3.6 million.
Convert minutes and add repeated use
A 1,500 W appliance on for 20 minutes has power 1.5 kW and running time :
Twenty minutes is not 0.20 h; it is one third of an hour. For repeated use, multiply the daily on-time by the number of days. A 10 W LED on 5 h a day for 30 days runs for 150 h and uses .
A 3 W standby load running throughout 365 days uses . A small rate still produces a noticeable total over a long time.
Count actual on-time
A thermostat switches a load on and off. A 2 kW heater that is on for 40% of a 5-hour period has on-time and uses 4 kWh. Multiplying its rating by all five hours would give 10 kWh, as though the element ran continuously. When average input power is already given, multiply that average by the whole period without applying the on-time fraction again.
An electricity meter records cumulative energy. A change from 45,872 kWh to 46,262 kWh means used during that interval. The later total itself is not the interval's consumption.
Estimate battery energy
At a stated battery voltage, multiply volts by ampere-hours to obtain watt-hours. A 12 V, 50 Ah battery represents approximately . The usable amount is lower in practice. Ah measures charge, so two batteries with equal Ah but different voltages have different energy capacities. For power and running-time estimates, the voltage cannot be left out.
Key Takeaways
- Watts × seconds gives joules; kilowatts × hours gives kilowatt-hours.
- One kilowatt-hour equals 3.6 MJ.
- Convert minutes to hours by dividing by 60.
- Use actual on-time or average power for cycling loads.
- Subtract the earlier meter reading from the later reading.
- Battery voltage × Ah gives approximate energy in Wh.
5.2 Calculate bills, savings and payback
Electricity cost comes from energy use and the price charged for each kilowatt-hour. A bill can also include fixed charges. Separating those parts helps explain why reducing consumption does not remove every charge.
Turn energy into money
At an example price of $0.18 per kWh, a 2 kW heater running for 3 h uses 6 kWh and costs dollars, or $1.08. For repeated use, calculate kW × hours per day × days before multiplying by the price.
A 60 W lamp on for 5 h uses . Its cost is dollars, rounded to $0.05. Using 60 as kilowatts makes the answer a thousand times too large. Also keep cents and dollars consistent: 18 cents is $0.18, not $18. Round money at the end so repeated small amounts are not lost during working.
Add each billed charge
A meter interval of 390 kWh at $0.18 per kWh gives $70.20 in energy charges. A fixed charge of $0.50 per day over 30 days adds $15.00:
That gives $85.20 before any separately stated taxes or network fees. Use the charges and rates on the relevant bill; a quoted example price is not a current tariff.
Under time-of-use pricing, calculate each period separately. A 3 kWh dryer cycle costs $0.90 at $0.30 per kWh, or $0.36 at $0.12 per kWh. Moving the cycle changes cost even though the cycle's energy stays at 3 kWh.
Compare an upgrade over the same service
Replacing a 50 W halogen lamp with a 6 W LED providing the required light saves 44 W, or 0.044 kW. At 4 h a day for 365 days, the time is 1,460 h:
At $0.18 per kWh, the yearly saving is dollars, about $11.56. If the LED costs $4.00 more to buy, simple payback is:
That is about 4.15 months. Compare the extra purchase price with the annual saving, not with annual energy in kWh.
Use a machine's electrical input
A 2.2 kW shaft-output motor at 85% efficiency needs of electrical input at full load. Six hours uses about 15.5 kWh and costs about $2.80 at the example price. Using 2.2 kW directly would give about $2.38 and omit the motor's losses. If the machine operates at a different load or cycles, use its actual input and operating pattern for the cost.
Key Takeaways
- Cost equals kWh used multiplied by the price per kWh.
- Convert watts to kilowatts and cents to dollars before multiplying.
- Add fixed charges separately and price time-of-use periods individually.
- Compare appliances over the same useful service and operating time.
- Simple payback is extra purchase cost divided by annual money saved.
- Use electrical input power when costing a motor.
Ohm’s Law examples
1Read a small DC load’s electrical values
16 steps
- 1IntroductionGive each reading a meaning
A small DC load has a voltage across it, a current through it and a running time. Those readings answer different questions: how much energy each coulomb transfers, how quickly charge moves, and how long the transfer continues. Start by reading the units, then connect the readings to charge and energy. You will also see why measuring current and measuring voltage need different meter connections.
- 2ExplanationRead the symbol after the number
In “180 mA,” A names amperes and m makes the value one thousandth as large as the same number of amperes. The current is 0.180 A. In “2.2 kΩ,” k multiplies ohms by 1,000, giving 2,200 Ω.
Case matters: m means milli, M means mega, and kilo uses lowercase k. Read the complete number, prefix and unit before choosing a formula.
- 3ExampleConvert the load’s readings
A bench load draws 180 mA from 15 V for 3 minutes. Put the current and time into the units used by charge calculations:
The voltage is already in volts. Keep the converted current separate from the original milliampere value so the calculator does not receive 180 A by mistake.
- 4TipSquare an area’s conversion factor
An area conversion uses the length factor twice. Since 1 mm is one thousandth of a meter:
For a 3 mm² conductor, write 0.000003 m² when the resistivity uses Ω·m. With resistivity in Ω·mm²/m, keep the area in mm² instead. Matching the unit set avoids an extra factor of one million.
- 5ChallengeConvert a control current
A display gives 0.00024 A. What is this current in μA?
---reveal---
It is 240 μA, because . In engineering notation it is . Scientific notation for the same value is ; the value has not changed, only how it is written.
- 6ExplanationCurrent counts charge passing a point
Current is the amount of charge passing a point per second:
One ampere means one coulomb each second. In metal wires, free electrons carry charge; they drift opposite to conventional current. Circuit arrows follow conventional current from the source’s positive terminal through the external circuit toward its negative terminal.
- 7ExampleMultiply the rate by the running time
For the bench load, current is 0.180 A and running time is 180 s. Rearrange the current definition:
This is the charge magnitude that passes a chosen point during those three minutes. Multiplying 0.180 by 3 would account for only three seconds and give a result sixty times too small.
- 8Key InsightThe load takes energy, not current
Charge continues around a complete path. In a single loop, the current leaving a load equals the current entering it. The load transfers energy, while charge keeps circulating.
Opening the path stops current throughout that loop. Copper provides a conducting path with many mobile electrons; an insulating covering such as PVC helps keep that path separate from other conducting parts.
- 9ChallengeUse a charge capacity
An ideal battery has 1.8 Ah of charge capacity. How long can it supply a steady 0.30 A?
---reveal---
Ampere-hours divided by amperes gives hours. One Ah is also 3,600 C. Real usable capacity depends on conditions, so this calculation describes the ideal capacity and constant current given.
- 10ExplanationVoltage gives energy per coulomb
Voltage compares energy per charge between two points:
A 15 V supply gives an energy difference of 15 J per coulomb. It does not mean 15 C flows each second or that the source contains only 15 J. A source’s emf describes energy it supplies per coulomb; potential difference across a load describes energy transferred from electrical form.
- 11ExampleFind the energy transferred
The bench load has 15 V across it and passes 32.4 C during its run. Each coulomb transfers 15 J:
The voltage and total charge together determine energy. If the same current continued for twice as long, twice the charge would pass and twice the energy would transfer, while the voltage could stay at 15 V.
- 12ConnectionPut each meter in the right place
A voltmeter compares two points, so its leads connect across the load in parallel. Its high resistance keeps the current it draws small.
An ammeter connects in series so the current passes through its low resistance. Putting that low resistance across a supply would create a near short circuit. The desired quantity determines the connection, even when both functions share one meter.
- 13ExplanationRead DC, AC and rms
A DC source keeps its polarity. An AC source reverses polarity, with frequency counting complete cycles each second. Familiar mains examples are 230 V at 50 Hz and 120 V at 60 Hz.
The AC voltage is an rms value: in a fixed resistor, it produces the same average heating as the same numerical DC voltage. That equivalence lets resistive-load calculations use rms values directly.
- 14ChallengeLook across an open switch
A 12 V battery, an intact resistor and a switch form one loop. The switch is open. Can the switch have 12 V across it even though no current flows?
---reveal---
Yes. The break stops loop current, but voltage can still exist across the break. With zero current, the intact resistor has no voltage drop. Voltage measures an energy difference between two points; it does not require charge to be moving at that moment.
- 15TipRead a voltage-band name carefully
IEC-based extra-low voltage extends to 50 V AC rms or 120 V ripple-free DC. Low voltage extends above those limits to 1,000 V AC or 1,500 V DC.
Household mains is called low voltage in this technical classification, but can still cause fatal shock. The band name describes voltage magnitude and must not be read as a statement that touching the conductors is safe.
- 16RecapKeep rate, charge and energy distinct
Prefixes set the scale of a reading. Current is charge per second, so . Voltage is energy per coulomb, so . Use the time and unit conversions before multiplying. Meter connections follow those meanings: current through the ammeter, voltage across the voltmeter’s two test points.
2Use readings to explain a resistor and its faults
14 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionBegin with a pair of readings
- 2ExplanationResistance is a ratio
- 3ExampleCompare two operating points
- 4Key InsightA lamp changes as it heats
- 5ChallengeCheck a resistor’s tolerance
- 6ExplanationChoose the unknown first
- 7ExampleCalculate a current and check it
- 8ChallengePredict two changes together
- 9ExplanationA break can hold the full voltage
- 10ExampleA low-resistance bypass draws a large current
- 11ConnectionA joint can conduct and still waste voltage
- 12ChallengeSeparate a zero-current reading from a short
- 13TipDo not read “OL” as zero
- 14RecapInterpret the state before predicting
3Calculate a two-wire feed from size to voltage drop
13 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionFollow both conductors
- 2ExplanationSeparate resistivity from resistance
- 3ExampleCompare changes in shape
- 4ExampleCorrect for the temperature rise
- 5ChallengeUse diameter and length together
- 6ExplanationBuild the conductor formula
- 7ExampleRead the feed’s dimensions
- 8ExampleCalculate total feed resistance
- 9ExampleFind the voltage reaching the load
- 10TipFind area from diameter first
- 11ChallengeCompare a longer feed with thicker wire
- 12ConnectionUse a limit to calculate area
- 13RecapMove from dimensions to delivered voltage
4Connect power, heating and a machine’s output
15 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionTrack where the power goes
- 2ExplanationChoose a form from the known values
- 3ExampleUse the rated conditions
- 4ChallengeReduce the voltage
- 5TipUse the cable’s own electrical values
- 6ExplanationHeat follows current squared
- 7ExampleCalculate a contact’s heat
- 8ConnectionCooling determines the resulting temperature
- 9ChallengeHold the correct quantity fixed
- 10ExplanationDistinguish input from useful output
- 11ExampleFind a DC motor’s electrical input
- 12ExamplePass the shaft power through a gearbox
- 13ExplanationCalculate useful power in a lift
- 14ChallengeWork backward from useful power
- 15RecapFollow rates through the machine
5Turn an operating schedule into energy and cost
13 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart from the operating schedule
- 2ExplanationMatch the energy unit to the time
- 3ExampleConvert a short operating period
- 4ExampleCount an element’s actual on-time
- 5ChallengeUse two meter readings
- 6ConnectionInclude voltage in battery energy
- 7ExplanationApply the energy price
- 8ExampleAdd a daily fixed charge
- 9ChallengePrice each time period
- 10ExampleCalculate a replacement’s annual saving
- 11ChallengeFind when the extra price is recovered
- 12TipCost the input that actually runs the machine
- 13RecapKeep energy and charges in separate steps
Ohm’s Law practice questions
Set 1: Read values and use the core relationships10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Interpret measurements and operating conditions10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Connect cable losses, power and useful output10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Solve combined workshop and energy problems10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
A
Alternating current supply
Ammeter
Ampere-hour
Annual saving
C
Circuit breaker
Conductance
Conductor
Contact resistance
Continuity
Conventional current
Coulomb
Cross-sectional area
Cumulative meter reading
Current-carrying capacity
D
Direct current supply
Direct proportion
E
Efficiency
Electric charge
Electric current
Electrical energy
Electromotive force
Energy charge
Engineering notation
Extra-low voltage
F
Fixed charge
Fuse
H
Hot spot
I
Input power
Insulator
Inverse proportion
J
Joule heating
K
Kilowatt-hour
M
Mechanical work
Micro
Minimum conductor area
N
Non-ohmic component
NTC thermistor
O
Ohm’s law
Ohmic component
On-time fraction
Open circuit
Operating point
Over-range indication
Overall efficiency
Overload
P
Positive temperature coefficient
Potential difference
Power
Power dissipation
Power loss
Q
Quantity symbol
R
Rated power
Rating plate
Resistance
Resistance tolerance
Resistivity
Rms voltage
S
Scientific notation
Short circuit
SI unit
Simple payback time
T
Temperature coefficient of resistance
Time-of-use tariff
Total conductor length
U
Unit prefix
Useful output power
V
Voltage drop
Voltmeter
W
Watt-hour
Wire diameter
About this lesson
Make your own Study Materials
Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.