Electrical Quantities and Ohm’s Law

Learn the core electrical science behind every installation, machine and appliance. Write values with SI units and prefixes, explain charge, current and voltage, and use Ohm’s law to find voltage, current and resistance. Calculate the resistance of cables from resistivity, the power, heating and efficiency of loads, and the energy they use in kilowatt-hours and what it costs.

BeginnerLesson 1 of 7 in Electrical Principles for Technicians Course

What you will learn

  1. Write every electrical value with the correct quantity, unit and prefix, and explain what charge, current and voltage mean in a working circuit.
    • Write and convert values with SI units and prefixes
      Name the symbol and SI unit of each electrical quantity, convert between prefixes and powers of ten, and get values into base units before calculating.
    • Explain charge and current and calculate with Q = It
      Describe current as a flow of charge, use the coulomb, ampere and ampere-hour, and calculate charge, current or time.
    • Explain voltage and the types of electrical supply
      Define voltage as energy per unit charge, distinguish emf from potential difference, measure voltage across a component and tell DC and AC supplies apart.
  2. Explain resistance and Ohm’s law, find voltage, current or resistance from measurements and calculations, and use the law to explain open circuits, short circuits and poor connections.
    • Explain resistance and Ohm’s law from measurements
      Define resistance as the ratio of voltage to current, investigate the relation between voltage and current by measuring, and tell ohmic from non-ohmic components.
    • Calculate voltage, current and resistance with V = IR
      Choose and rearrange the right form of Ohm’s law, handle prefixes, and use proportional reasoning to predict how current changes.
    • Use Ohm’s law to explain open circuits, short circuits and poor connections
      Predict currents and voltages when a circuit is broken, shorted or has a high-resistance connection, and read voltage and resistance measurements in that light.
  3. Explain how material, length, cross-section and temperature set a conductor’s resistance, and calculate cable resistance and voltage drop with resistivity.
    • Explain how material, length, area and temperature affect resistance
      Relate a conductor’s resistance to its length, cross-sectional area and material through resistivity, and describe how temperature changes it.
    • Calculate conductor resistance and cable voltage drop with R = ρL/A
      Use and rearrange R = ρL/A with consistent units, include both conductors of a cable run, and work out the voltage lost along a cable.
  4. Calculate the power of loads with the power formulas, explain the heating effect of current in conductors and connections, and use efficiency to link electrical input to useful output.
    • Calculate electrical power with P = VI, I²R and V²/R
      Define power as the rate of energy transfer, choose the power formula that fits the known values, and read the power and voltage on a rating plate.
    • Explain the heating effect of current in conductors and connections
      Use P = I²R to explain heating in elements, cables, connections and fuses, and why cable size must match the current.
    • Calculate efficiency and link electrical and mechanical power
      Calculate efficiency and losses, distinguish a motor’s input and output power, and calculate mechanical power from force, distance and time.
  5. Calculate the energy appliances and machines use in joules and kilowatt-hours, and turn it into running costs, bills and savings.
    • Calculate energy in joules and kilowatt-hours
      Use W = Pt with the right units, convert between joules and kilowatt-hours, and read energy use from meter readings and usage patterns.
    • Calculate and compare electricity costs
      Turn energy use into cost with a price per kWh, work out bills with fixed charges and time-of-use prices, and compare running costs, savings and payback.

Ohm’s Law study guide

5 chapters

1

Read units and explain electrical quantities

A reading of 12 V and a reading of 12 A tell you very different things. Units identify what has been measured, while prefixes make very large and very small values easier to handle. Charge, current and voltage then explain what happens in a circuit: charge moves, current measures its rate of flow, and voltage describes the energy transferred by each coulomb. These meanings guide both calculations and the way meters connect.

1.1 Use electrical symbols and convert prefixes

A value combines a number with a unit. In “4.7 kΩ,” the prefix k means one thousand, so the resistance is 4,700 ohms.

Match the quantity to its unit
QuantityQuantity symbolUnitUnit symbol
ChargeQcoulombC
CurrentIampereA
VoltageV, also UvoltV
ResistanceRohmΩ
PowerPwattW
Energy or workW, also EjouleJ
Timetseconds

A symbol's position tells you its job. In “V = 12 V,” the first V names voltage; the last V names volts. W can name work in a formula, but W after a number means watts. Many IEC and European texts use U for voltage, giving U=RI for the same relationship as V=IR.

The ampere, second, meter and kilogram are SI base units. Electrical derived units connect to them: a coulomb is an ampere-second, a volt is a joule per coulomb, an ohm is a volt per ampere, and a watt is a joule per second.

Replace a prefix with a power of ten
PrefixSymbolFactor
picop10−12
nanon10−9
microμ10−6
millim10−3
kilok103
megaM106
gigaG109

Case matters: m is milli, M is mega, and kilo uses lowercase k. For 250 mA, replace milli with 10−3:

250×10−3=0.250 A

Similarly, 35 μA is 3.5×10−5 A, 2.2 MΩ is 2.2×106 Ω, and 1.5 kW is 1,500 W. Converting the other way, 0.0068 A is 6.8 mA.

Scientific notation gives one nonzero digit before the decimal point. Engineering notation uses exponents that are multiples of three: 0.00047 A is 4.7×10−4 A or 470×10−6 A, which is 470 μA. Enter “4.7 EXP 3” to obtain 4,700 on a calculator; “4.7 × 10 EXP 3” adds an unwanted factor of ten.

Keep the units consistent in a calculation

A 20 mA current through 330 Ω gives:

V=0.020×330=6.6 V

Using 20 without converting would make the voltage one thousand times too large. Base units are a reliable route. Compatible prefixes can also cancel: 2 mA through 4.7 kΩ gives 9.4 V because 10−3×103=1.

An area needs the length conversion twice:

1 mm2=(10−3 m)2=10−6 m2

Thus 2.5 mm² is 2.5×10−6 m2. Use m² with resistivity in Ω·m; use mm² directly with resistivity in Ω·mm²/m. Write a space between a value and its unit, as in “12 V.” Keep full calculator precision during working, then round the final answer, usually to three significant figures.

Key Takeaways

  • A prefix changes the value by its stated power of ten; upper and lower case matter.
  • Quantity symbols and unit symbols can use the same letter for different jobs.
  • Base units make substitution reliable; compatible prefix factors can also cancel.
  • An area of 1 mm² equals 10−6 m2.
  • Keep full precision until the final answer and include its unit.

1.2 Follow charge through a circuit

Charge is a property of particles. Electrons carry negative charge and protons carry positive charge. A current tells you how quickly charge passes a chosen point in a circuit.

Count charge per second

The coulomb (C) measures charge. One electron carries approximately −1.602×10−19 C. About 6.24×1018 electrons therefore carry −1 C, whose magnitude is 1 C. In circuit calculations, the amount of charge passing is usually written as a positive magnitude.

Current is charge divided by elapsed time:

I=Qt,Q=It,t=QI

One ampere means one coulomb passes each second. In copper or aluminum, free electrons move through the metal. In an electrolyte, such as battery acid, moving ions carry current.

Suppose a current of 2.5 A flows for 4 minutes. First convert the time:

t=4×60=240 s

Then multiply the rate by the time:

Q=2.5×240=600 C

That is a charge magnitude equal to about 3.75×1021 electrons. Using the number 4 as though it were seconds would give only 10 C. The time unit must match the ampere's meaning of coulombs per second.

To find current, 90 C passing in 30 s gives I=90/30=3 A. To find time, delivering 120 C at 0.4 A takes t=120/0.4=300 s, or 5 minutes.

Read battery capacity in ampere-hours

An ampere-hour is another unit of charge:

1 Ah=1 A×3600 s=3600 C

A 2 Ah battery represents 7,200 C of charge capacity. At a steady 0.5 A, its ideal running time is 2/0.5=4 h. High currents and low temperatures can reduce the usable capacity. Ah alone does not state energy; the battery voltage matters too.

Keep direction separate from energy transfer

Conventional current runs from the positive terminal through the external circuit to the negative terminal. Electrons in the metal drift in the opposite direction. Circuit arrows use conventional current, so there is no need to reverse an arrow to make it follow electrons.

Charge circulates around a closed path. A load transfers energy from the circuit, but does not use up current. In one closed loop, the current entering the load equals the current leaving it. Opening a switch breaks that path and stops the current throughout the loop.

Copper and aluminum conduct easily because they have many mobile electrons. PVC, rubber, glass and dry wood act as insulators, separating or covering conducting parts. The current's size depends on the load: an indicator LED commonly takes 10–20 mA; a phone charger's low-voltage output may be 1–3 A; a 230 V kettle draws roughly 9–13 A.

Put an ammeter in the path

An ammeter connects in series, so the current being measured passes through it. Its resistance is very low. Across a supply it would create a near short circuit, potentially blowing its fuse or damaging the meter. A voltage measurement needs a different connection.

Key Takeaways

  • Current is charge passing per second: I=Q/t.
  • Use seconds when calculating coulombs from amperes.
  • One ampere-hour equals 3,600 C.
  • Conventional current and electron drift have opposite directions in a metal.
  • A load transfers energy; the current is not used up.
  • An ammeter connects in series.

1.3 Understand voltage and DC or AC supplies

Voltage describes the energy transferred by each coulomb moving between two points. It can be present even when the circuit is open and no current flows. A disconnected battery still has voltage between its terminals.

Connect voltage, charge and energy

Potential difference, often shortened to p.d., is:

V=WQ,W=VQ

One volt means one joule per coulomb. A 9 V battery moving 2 C transfers 9×2=18 J. If a lamp receives 54 J while 6 C passes, the voltage across it is 54/6=9 V. A larger voltage gives more energy transfer for the same amount of charge.

Voltage always compares two points. A quoted “voltage at a point” uses an implied reference such as 0 V or earth. Say “current through the load” and “voltage across the load”; voltage itself does not flow.

A source's electromotive force, or emf, is the energy it supplies per coulomb by converting chemical, mechanical or light energy. Potential difference across a load describes energy transferred from electrical form. Both are measured in volts. A real source's internal resistance makes its terminal voltage lower than its emf while it supplies current.

Compare the two points with a voltmeter

Connect a voltmeter in parallel, with one lead at each end of the component. Its high resistance lets it compare the points while drawing very little current. An ideal voltmeter has infinite resistance. In series, a real voltmeter greatly reduces the loop current, so the load may stop and the meter can read nearly the whole supply voltage.

Tell supply types apart
SupplyWhat the polarity doesExamples
DCKeeps the same polarityCells, batteries, solar panels, DC power supplies
ACReverses repeatedlyPublic mains supplies

A 1.5 V cell, a 12 V vehicle battery and an 18 V tool battery are familiar DC sources. Public mains examples include 230 V at 50 Hz in much of Europe and 120 V at 60 Hz in the United States and Canada. Frequency in hertz counts complete cycles each second.

The stated AC voltage is an rms value, short for root mean square. A 230 V rms AC supply produces the same average heating in a fixed resistor as 230 V DC. This lets you use rms voltage and current in Ohm's law and the power formulas for resistive loads. Motors and other loads with coils require further AC relationships to calculate their input from voltage and current.

Read voltage-band names correctly

IEC-based terminology places extra-low voltage at up to 50 V AC rms or 120 V ripple-free DC. Low voltage is above those limits and extends up to 1,000 V AC or 1,500 V DC. Household mains belongs to the low-voltage band. That technical name describes a band, not freedom from shock danger: household mains can be fatal.

Key Takeaways

  • Voltage is energy transferred per coulomb between two points.
  • Emf describes energy supplied per coulomb; it is measured in volts.
  • A voltmeter connects in parallel and has high resistance.
  • DC keeps its polarity; AC reverses polarity.
  • Rms AC values give the equivalent heating effect in a fixed resistor.
2

Use resistance and Ohm’s law

Resistance links the voltage across a component to the current through it. Measurements show when that link stays proportional and when heating or component behavior changes it. From there, you can choose the right form of Ohm’s law, handle prefixes, and check the result. The same reasoning explains why a broken path stops current, a short circuit drives a large current, and a poor connection can become hot.

2.1 Find resistance from measurements

Resistance describes how much voltage is needed to drive a given current. Its unit is the ohm (Ω). A component has a resistance of 1 Ω at an operating point if 1 V across it produces 1 A through it.

Calculate the voltage-to-current ratio
R=VI

At the same voltage, a larger resistance carries less current. Conductance describes the ease of conducting and is the reciprocal:

G=1R

Its unit is the siemens (S). A 50 Ω component has a conductance of 1/50=0.020 S. Resistance and conductance describe the same component from opposite directions, but are different quantities.

In a metal, drifting electrons interact with vibrating atoms. Energy transfers to the metal as heat. Raising the metal's temperature usually makes these interactions stronger, increasing its resistance.

Test whether resistance stays constant

Ohm's law states that current through a metallic conductor at constant temperature is directly proportional to the voltage across it. Its resistance stays constant:

V=IR

To investigate, use a variable DC supply, an ammeter in series with the component, and a voltmeter across it. Record several voltage–current pairs. Calculate the ratio for each pair or plot current vertically against voltage horizontally.

VoltageCurrentResistance
2 V0.10 A20 Ω
4 V0.20 A20 Ω
6 V0.30 A20 Ω
8 V0.40 A20 Ω

Every ratio is 20 Ω. Doubling voltage doubles current, so these readings show ohmic behavior. The current–voltage plot is a straight line through the origin. Its slope is I/V=1/R; a steeper current–voltage line means lower resistance. A voltage–current graph with its axes reversed has slope R instead.

Recognize a changing resistance

The ratio R=V/I gives resistance at a particular operating point even for a non-ohmic component. What fails is carrying that same resistance to a different point without checking it.

A filament lamp heats as current increases. At 6 V and 1.2 A its resistance is 6/1.2=5.0 Ω. At 12 V and 1.75 A it is about 6.9 Ω. Doubling voltage did not double current because the hotter filament had more resistance. Its current–voltage curve bends toward the voltage axis. The cold filament's lower resistance also explains its high switch-on current.

A diode mainly conducts in one direction. A thermistor changes resistance strongly with temperature; a light-dependent resistor decreases resistance as illumination increases. Even a fixed resistor may drift during measurements if it warms, so low-current or quick readings help keep temperature steady.

Allow for manufacturing tolerance

A stated resistance is a nominal value. A 4.7 kΩ resistor with ±5% tolerance permits a difference of 4700×0.05=235 Ω either way. Its allowed range is therefore 4,465–4,935 Ω. A measured value within that range meets the stated tolerance.

Key Takeaways

  • Resistance is voltage divided by current at the same operating point.
  • Ohm’s law adds that resistance stays constant as voltage changes at constant temperature.
  • A straight current–voltage line through the origin has slope 1/R.
  • A hot filament has more resistance than a cold filament.
  • Tolerance gives an allowed range around a nominal resistance.

2.2 Choose the right form of Ohm’s law

Start with the quantity you need, then choose the equation that leaves it alone on one side. The three forms of Ohm's law are rearrangements of one relationship, not three separate rules.

Match the equation to the unknown
FindEquationCalculation
VoltageV=IRCurrent × resistance
CurrentI=V/RVoltage ÷ resistance
ResistanceR=V/IVoltage ÷ current

Dividing both sides of V=IR by I leaves V/I=R. This explains why the resistance formula is voltage divided by current. Reversing that ratio gives conductance instead.

A triangle with V above I and R is a useful memory aid. Cover V to see multiplication; cover I or R to see a division with V on top. The equation still needs the correct units and the readings for the same component.

Work a current calculation

A heating element with a working resistance of 46 Ω is connected across 230 V. The known values are voltage and resistance, so:

I=23046=5.00 A

Check by multiplying back: 5 A through 46 Ω needs 230 V. For a 4.7 kΩ resistor across 12 V, convert resistance to 4,700 Ω first:

I=124700=0.002553… A≈2.55 mA

The larger resistance on the smaller voltage gives a much smaller current, which supports the size of the answer.

Find voltage or resistance

A current of 20 mA through 330 Ω requires:

V=0.020×330=6.6 V

For 2 mA through 4.7 kΩ, the prefixes cancel, giving 9.4 V directly. If unsure about prefix combinations, convert to amperes and ohms before multiplying.

A load draws 30 mA from 9 V. Convert the current to 0.030 A:

R=90.030=300 Ω

Dividing by 30 would give 0.3 Ω, one thousand times too small. A quick reverse check exposes it: 0.3 Ω on 9 V would carry 30 A, not 30 mA.

Predict a change before calculating

For a fixed resistance, voltage and current change in the same proportion. The 46 Ω element draws 2.5 A at 115 V because the voltage has halved. For fixed voltage, doubling resistance halves current. If both change, apply both factors: doubling voltage while tripling resistance makes the current 2/3 of its former value.

These predictions rely on resistance staying fixed. A lamp whose filament temperature changes cannot use its cold resistance to predict its hot current. You can still calculate its resistance from a voltage and current measured together at the operating point.

Always pair the voltage across a component with the current through that component. A load directly connected to a supply receives approximately its supply voltage; the connecting leads can account for a small difference. A cable's own resistance must be paired with the voltage lost along that cable, not the full supply voltage.

Key Takeaways

  • Use V=IR, I=V/R or R=V/I to isolate the required quantity.
  • Convert prefixes before substitution and check with the original equation.
  • At fixed resistance, current changes in proportion to voltage.
  • At fixed voltage, current changes inversely with resistance.
  • Use voltage and current for the same component.
  • A non-ohmic component’s resistance belongs to its operating point.

2.3 Explain breaks, shorts and poor connections

A circuit that stops working can have very different electrical faults. The effect depends on whether the path is broken, bypasses the load, or still conducts through an unwanted resistance.

Compare an open circuit with a short circuit
FaultPathCurrent in the simple loop
Open circuitBrokenZero
Short circuitVery low resistance bypasses the loadCan become extremely large
Poor connectionConducts through unwanted contact resistanceMay continue, with local voltage loss and heating

An open switch, broken conductor or blown fuse opens the path. In the ideal single loop, the break acts like infinite resistance. With no current, the intact load has no voltage drop, while the full supply voltage appears across the break. An open switch in a 230 V lamp loop can therefore have about 230 V across it while the lamp has 0 V.

A short creates a path of very low resistance. At 230 V, a total fault-path resistance of 0.5 Ω gives:

I=2300.5=460 A

The resistance of the source, cables and fault path limits the current. A real short has small resistance, not a mathematical zero that allows division by zero. The source voltage has not simply vanished everywhere.

An overload leaves current flowing through a load, but the current exceeds what the circuit was designed to carry. Too much connected equipment or a jammed machine can cause it. A short-circuit current is often far larger; an overload can heat a cable more slowly. A protective device's disconnection time depends on the size of the excess current and its design.

Follow the voltage lost at a bad joint

A loose or corroded contact adds resistance at a small point in the path. If 16 A flows through 0.1 Ω:

Vjoint=16×0.1=1.6 V

That is energy transferred at the joint instead of being delivered to the load. Heating concentrated at the contact can damage terminals and insulation even though the circuit still works.

A sound closed switch or good joint has very low resistance, so its voltage drop under load is almost zero. Nearly the full supply voltage across a supposedly closed switch, fuse or joint suggests a break or a very high resistance at that location. A voltage reading must be interpreted with the circuit's operating state: a zero reading across a sound conductor does not mean the supply is absent.

Interpret a resistance reading

An ohmmeter sends a small test current from its own battery. Near 0 Ω indicates continuity through a low-resistance path. “OL” means the resistance exceeds the selected range; an open circuit is one possible reason. It is not a reading of zero resistance.

Measure resistance only with the circuit isolated from its supply and the component disconnected as required. Make live measurements only when trained and authorized, using a meter and leads rated for the circuit.

Key Takeaways

  • An open path stops loop current, but voltage can remain across the break.
  • A short circuit provides a very low-resistance path and can drive a large current.
  • An overload still sends current through a load.
  • A poor contact can lose voltage and concentrate heat.
  • An ohmmeter’s “OL” display means over range, not zero ohms.
3

Calculate cable resistance and voltage drop

A cable is a conductor with a length, cross-sectional area, material and operating temperature. Each of these helps set its resistance. The supply-to-load distance is only part of the current’s journey in a two-wire circuit: the return conductor matters too. Combining conductor resistance with the load current lets you calculate voltage lost in the cable and judge how a change of length or area affects delivery.

3.1 Relate resistance to material, size and temperature

Two pieces of wire can have different resistances even when they are made from the same metal. Material sets resistivity; the wire's dimensions and temperature turn that material property into the resistance of a particular piece.

Separate material from shape

Resistance increases in proportion to length and decreases in proportion to cross-sectional area. Double a wire's length at the same temperature and its resistance doubles. Double its area and resistance halves. A larger area provides more conducting paths side by side.

Resistivity, written ρ (rho), describes a material at a specified temperature. It can be understood as the resistance between opposite faces of a 1 m cube. Its SI unit is the ohm-meter, Ω·m. Resistance in ohms belongs to a piece; resistivity belongs to its material.

Material at 20 °CApproximate resistivity in Ω·m
Silver1.59×10−8
Annealed copper1.72×10−8
Conductor-grade aluminum2.8×10−8
Nichrome1.1×10−6

Glass and PVC have resistivities around 1010 Ω⋅m or greater. Material grade and purity change published values, so use the resistivity supplied for a calculation.

Installers often express resistivity in Ω·mm²/m. This matches conductor areas in mm² without converting them to m². The conversion is:

1 Ω⋅mm2/m=10−6 Ω⋅m

Copper's value is therefore 0.0172 Ω·mm²/m, and conductor-grade aluminum is about 0.028 Ω·mm²/m. Copper combines low resistivity with useful bending and joining properties. Aluminum is lighter for a given resistance, making it useful for large cables and overhead lines. Nichrome's higher resistivity and resistance to oxidation at high temperature suit heating elements.

Distinguish diameter from area

Doubling the diameter does more than double the conducting area. For a circular cross-section:

A=πd24

Area increases with diameter squared. Doubling diameter gives four times the area and, for the same material, length and temperature, one quarter of the resistance. This is why a diameter ratio cannot be used directly as an area ratio.

Allow for warmer metal

Metals have a positive temperature coefficient: their resistance rises as they warm. For a moderate change from 20 °C:

RT=R20[1+α(T−20)]

Here T is the temperature in °C and α for copper is about 0.00393 per °C. A 10.0 Ω winding warming from 20 °C to 70 °C has a temperature increase of 50 °C:

R70=10.0[1+0.00393×50]=11.965 Ω

Its resistance is about 12.0 Ω, nearly 20% above the cold value. Use the temperature rise of 50, not the final temperature 70, inside the correction. NTC thermistors behave differently: their resistance falls with rising temperature. Alloys such as constantan change relatively little.

Key Takeaways

  • Resistance rises with length and falls with cross-sectional area.
  • Resistivity describes a material at a stated temperature.
  • Copper is about 0.0172 Ω·mm²/m at 20 °C.
  • Doubling wire diameter gives four times the area and one quarter of the resistance.
  • A metal’s temperature correction uses its change from the reference temperature.

3.2 Include the return path in cable calculations

A conductor's resistance follows from resistivity, length and area. Before entering numbers, decide which length carries current and which area unit matches the resistivity.

Set up a consistent calculation
R=ρLA,L=RAρ,A=ρLR

With ρ in Ω·m, use L in m and A in m². With ρ in Ω·mm²/m, use m and mm². Mixing Ω·m with an area left in mm² makes resistance one million times too small.

A load is 20 m from its source. In a two-wire DC circuit, current travels 20 m out and 20 m back. Both conductors contribute resistance, so total L is 40 m. For 2.5 mm² copper at 20 °C:

R=0.0172×402.5=0.2752 Ω

Using SI area gives the same result:

R=1.72×10−8×402.5×10−6=0.2752 Ω

Using only the source-to-load distance would halve the answer. If a task already gives total conductor length, use that length directly without doubling it again.

Start from diameter, length or a resistance limit

For wire of diameter 1.38 mm:

A=π×1.3824≈1.50 mm2

The division by four matters because the circle formula uses radius, which is half the diameter. Keep the unrounded area if another calculation follows.

A nichrome wire of 0.20 mm² area must have a resistance of 22 Ω. With resistivity 1.1×10−6 Ω⋅m:

L=22×0.20×10−61.1×10−6=4.0 m

For 50 m of copper limited to 0.5 Ω, the minimum calculated area is:

A=0.0172×500.5=1.72 mm2

Among sizes 1.5, 2.5, 4, 6, 10 and 16 mm², the next size up is 2.5 mm² for this resistance requirement. Choosing the nearer 1.5 mm² would exceed the maximum resistance.

Turn cable resistance into voltage drop

At a known current:

Vdrop=IRcable

The 0.2752 Ω cable carrying 16 A loses 16×0.2752=4.4032 V. From a 230 V source, the load receives about 225.6 V. As a percentage of supply voltage:

4.4032230×100%≈1.91%

IEC-based guidance gives typical limits of 3% for lighting and 5% for other loads supplied from the public network; national requirements can differ.

Ratios help compare alternatives. For the same material and temperature, changing from 100 m of 1.5 mm² wire to 50 m of 2.5 mm² wire multiplies resistance by 50100×1.52.5=0.30. The new resistance is 0.344 Ω. A warmer cable has more resistance, so its voltage drop at the same current is larger than its 20 °C value.

Key Takeaways

  • Use Ω·m with m², or Ω·mm²/m with mm².
  • Include outgoing and return conductors when both carry the load current.
  • Calculate circular area from A=πd2/4.
  • Rearrange the conductor formula to find a required length or minimum area.
  • Cable voltage drop is current times total cable resistance.
  • Calculate a percentage drop using the supply voltage as the denominator.
4

Calculate power, heating and useful output

Power describes how fast energy is transferred. In a load, that transfer can provide useful heat or mechanical work; in a cable or loose joint, it becomes unwanted heating. The right power formula depends on the quantities known and on what stays fixed. Efficiency then connects electrical input to useful output, including the extra input needed to run a motor and the losses through several machine stages.

4.1 Choose and use an electrical power formula

A watt is one joule transferred each second. A 2,000 W heater transfers energy twenty times as fast as a 100 W load while both are operating. Power is a rate, so it does not yet tell you the total energy used.

Connect the power formulas
P=Wt,P=VI

Voltage is joules per coulomb and current is coulombs per second. Multiplying them cancels coulombs, leaving joules per second, or watts. For a resistive load, substitute Ohm's law to obtain:

P=I2R,P=V2R

Choose the form that uses the known values. If current and resistance are given, square the current. If voltage and resistance are given, square voltage and divide by resistance. The voltage must be across the resistance and the current must pass through that same resistance. DC values apply directly; for resistive AC loads use rms values.

Read a rating plate

A plate marked “230 V ~ 2000 W” describes a 2,000 W AC load at 230 V. For a heater at that operating point:

I=PV=2000230≈8.70 A

Its element resistance is:

R=V2P=23022000=26.45 Ω

Using unrounded current and resistance in I2R returns 2,000 W. For a 1,500 W heater at 120 V, current is 12.5 A and resistance is 9.6 Ω. The lower-voltage heater draws more current for its stated power.

A 3 kW heater at 230 V needs about 13.0 A. Load current is a starting value for circuit design: the protective-device rating must suit the load, and the cable's permitted current must suit the device and installation conditions.

Predict power when voltage changes

For a fixed resistance, power is proportional to voltage squared. If the 230 V heater operates at 207 V with resistance treated as unchanged:

P=2000(207230)2=1620 W

Voltage has fallen to 90%, but power has fallen to 81%. Current also falls. Keeping the rated power fixed and calculating a rising current would describe a different kind of load behavior, not this fixed resistor.

Check the power of a small resistor

A 330 Ω resistor carrying 20 mA dissipates:

P=0.0202×330=0.132 W

A 0.25 W rating exceeds that calculated dissipation. The stated component rating applies under its specified operating conditions. Entering 20 as amperes before squaring would make the answer a million times too large: the conversion factor for milliamperes is squared along with the current.

The resistance of a short cable section is small, but the full supply voltage is not across that section in normal operation. Putting supply voltage into V2/R with only cable resistance would predict a short-circuit condition instead of the cable's actual heating. Use the current through the cable in I2R or its measured voltage drop in VI.

Key Takeaways

  • Power is energy transferred per second, measured in watts.
  • Use P=VI, P=I2R or P=V2/R with values for the same resistance.
  • A rating plate gives power at the rated operating conditions.
  • At fixed resistance, power changes with voltage squared.
  • Convert current to amperes before squaring it.

4.2 Explain heat in cables and contacts

Resistance converts electrical energy into heat whenever current flows. The same effect heats a kettle element, warms a supply cable and can damage a loose terminal. Whether that heat is useful depends on where it is produced and where it can escape.

Follow the square of current

Joule heating occurs at the rate:

P=I2R

For a resistance of 0.1 Ω, 8 A produces 82×0.1=6.4 W. At 16 A, it produces 162×0.1=25.6 W. Doubling current gives four times the heating in the same resistance. This rapid increase explains why a modest overload can matter thermally.

In a copper cable run with total resistance 0.2752 Ω, 16 A produces about 70.5 W along the conductors. Keeping length and current the same but increasing conductor area from 2.5 to 4 mm² reduces resistance to 0.172 Ω and heating to about 44.0 W. More area lowers resistance and reduces loss at a given current.

Distinguish total heat from a hot spot

A cable spreads its heat along its length. A poor connection can produce tens of watts in a tiny contact area. That concentrated heat can discolor a terminal, soften insulation and worsen the connection. A thermal camera can reveal a local hot spot even while the load continues running.

Current alone therefore does not describe every heating problem. Two paths carrying 16 A can have different losses because their resistances differ. A damaged high-resistance joint can overheat without the load current exceeding the protective device's rating.

Include heat escaping to the surroundings

A conductor's final temperature depends on both heat produced and heat released. Cables surrounded by thermal insulation, grouped with other cables or installed in hot spaces cool less effectively. Their permitted current is lower. Standard PVC cable insulation commonly has a 70 °C conductor temperature limit; the applicable cable data and installation conditions determine the rating.

A cable reel still wound on its drum traps heat. This is why its coiled-load rating is lower than its fully unwound rating. As a metal warms, its resistance rises; at unchanged current, that increases its heating further.

Understand protective heating effects

A fuse element melts when excess current lasts long enough, breaking the path. A typical circuit breaker has a thermal bimetal response for overloads and a magnetic response to very large short-circuit currents. The response depends on both the current's size and duration.

Ask what stays fixed

“More resistance gives more heat” needs a fixed quantity. At the same current, a larger resistance dissipates more power through I2R. At the same voltage, a larger resistance reduces current and dissipates less power through V2/R. At 230 V, 26.5 Ω produces about 2,000 W, while 53 Ω produces about 1,000 W. Always identify whether current or voltage is being held constant before predicting the change.

Key Takeaways

  • Joule heating rises with current squared for a fixed resistance.
  • A larger conductor area reduces cable loss at the same current.
  • Contact resistance concentrates heat in a small area.
  • Cable temperature depends on cooling as well as electrical loss.
  • A fuse opens through heating; a typical breaker responds to overloads and shorts.
  • The effect of changing resistance depends on whether current or voltage stays fixed.

4.3 Connect electrical input to useful mechanical power

A machine's useful output is smaller than its input because some energy transfers to unwanted forms. A motor loses energy through winding resistance, heating in its iron core, bearing friction, fan air resistance and sound.

Calculate efficiency and loss

Using efficiency as a decimal:

η=PoutPin,Ploss=Pin−Pout

Multiply the ratio by 100% to express efficiency as a percentage. A motor taking 2.5 kW and delivering 2.0 kW has efficiency 2.0/2.5=0.80=80% and loses 0.5 kW, or 500 W. Compare powers in the same units. An answer above 100% for these machines means the values, units or calculation need checking.

To find the required input, rearrange:

Pin=Poutη

Enter 85% as 0.85 in this equation. Dividing by 85 would make the input one hundred times too small.

Read a motor rating as output

A motor's rated kW normally describes useful mechanical power at its shaft. A 2.2 kW saw motor at 85% efficiency needs:

Pin=2.20.85=2.588… kW≈2.59 kW

For a DC motor delivering 270 W at 75% efficiency, input is 270/0.75=360 W. On an 18 V supply, its input current is 360/18=20 A. Using output directly in the current calculation would miss the power lost inside the motor.

Find mechanical output from a lift

Mechanical work is force times distance moved in the force's direction:

W=Fs,P=Fst

For steady speed, P=Fv. Use newtons for force, meters for distance, seconds for time and meters per second for speed. For a lifted mass, weight is F=mg with g≈9.81 N/kg.

A hoist lifts 50 kg through 6 m in 10 s. The weight is 50×9.81=490.5 N. Work is 490.5×6=2943 J, so useful power is 2943/10=294.3 W. If electrical input is 420 W, efficiency is 294.3/420×100%≈70.1%. Mass is not force: entering 50 as newtons would omit gravity.

Follow power through several stages

Each stage passes on only a fraction of the power it receives. A motor with 85% efficiency driving a gearbox with 90% efficiency has overall efficiency:

ηoverall=0.85×0.90=0.765=76.5%

For every 1,000 W entering the motor, 850 W reaches the gearbox and 765 W leaves it. The gearbox's 10% loss acts on its 850 W input. Adding or averaging the percentages misses this changing input. For the same useful output and operating time, a more efficient machine needs less input energy and costs less to run.

Key Takeaways

  • Efficiency is useful output divided by input; losses are input minus useful output.
  • Use decimal efficiency when calculating input from output.
  • A motor’s rated shaft power is its mechanical output.
  • Mechanical work is force times distance; power is work divided by time.
  • A lifted mass has weight mg in newtons.
  • Multiply stage efficiencies to find overall efficiency.
5

Work out energy use and running costs

An appliance’s power tells you its rate of use; its running time tells you how much energy it consumes. Meter readings and kilowatt-hours connect that energy to a bill. Some loads cycle on and off, and some machines state useful output instead of electrical input. Accounting for those details lets you compare running costs, include fixed charges and decide how long a more efficient purchase takes to repay its extra cost.

5.1 Calculate joules and kilowatt-hours

Energy adds up while a load runs. A high-power load for a short time can use less energy than a small load left on for many hours. Keep power and elapsed operating time separate until you multiply them.

Choose the energy unit first
W=Pt

With power in watts and time in seconds, energy is in joules. For an electrical load this can also be written W=VIt. A 60 W lamp on for one minute uses 60×60=3600 J.

With power in kilowatts and time in hours, the product is kilowatt-hours:

1 kWh=1000 W×3600 s=3.6×106 J=3.6 MJ

Meters use kWh because joules give very large numbers for daily energy use. The h multiplies kW; “kW/h” divides by time and is not energy.

A 2 kW heater on for 3 h uses 2×3=6 kWh. Converting to megajoules gives 6×3.6=21.6 MJ. To convert joules to kWh, divide by 3.6 million.

Convert minutes and add repeated use

A 1,500 W appliance on for 20 minutes has power 1.5 kW and running time 20/60=1/3 h:

W=1.5×13=0.5 kWh

Twenty minutes is not 0.20 h; it is one third of an hour. For repeated use, multiply the daily on-time by the number of days. A 10 W LED on 5 h a day for 30 days runs for 150 h and uses 0.010×150=1.5 kWh.

A 3 W standby load running throughout 365 days uses 0.003×24×365=26.28 kWh. A small rate still produces a noticeable total over a long time.

Count actual on-time

A thermostat switches a load on and off. A 2 kW heater that is on for 40% of a 5-hour period has on-time 5×0.40=2 h and uses 4 kWh. Multiplying its rating by all five hours would give 10 kWh, as though the element ran continuously. When average input power is already given, multiply that average by the whole period without applying the on-time fraction again.

An electricity meter records cumulative energy. A change from 45,872 kWh to 46,262 kWh means 46262−45872=390 kWh used during that interval. The later total itself is not the interval's consumption.

Estimate battery energy

At a stated battery voltage, multiply volts by ampere-hours to obtain watt-hours. A 12 V, 50 Ah battery represents approximately 12×50=600 Wh=0.6 kWh. The usable amount is lower in practice. Ah measures charge, so two batteries with equal Ah but different voltages have different energy capacities. For power and running-time estimates, the voltage cannot be left out.

Key Takeaways

  • Watts × seconds gives joules; kilowatts × hours gives kilowatt-hours.
  • One kilowatt-hour equals 3.6 MJ.
  • Convert minutes to hours by dividing by 60.
  • Use actual on-time or average power for cycling loads.
  • Subtract the earlier meter reading from the later reading.
  • Battery voltage × Ah gives approximate energy in Wh.

5.2 Calculate bills, savings and payback

Electricity cost comes from energy use and the price charged for each kilowatt-hour. A bill can also include fixed charges. Separating those parts helps explain why reducing consumption does not remove every charge.

Turn energy into money
cost=energy in kWh×price per kWh

At an example price of $0.18 per kWh, a 2 kW heater running for 3 h uses 6 kWh and costs 6×0.18=1.08 dollars, or $1.08. For repeated use, calculate kW × hours per day × days before multiplying by the price.

A 60 W lamp on for 5 h uses 0.060×5=0.3 kWh. Its cost is 0.3×0.18=0.054 dollars, rounded to $0.05. Using 60 as kilowatts makes the answer a thousand times too large. Also keep cents and dollars consistent: 18 cents is $0.18, not $18. Round money at the end so repeated small amounts are not lost during working.

Add each billed charge

A meter interval of 390 kWh at $0.18 per kWh gives $70.20 in energy charges. A fixed charge of $0.50 per day over 30 days adds $15.00:

70.20+15.00=85.20

That gives $85.20 before any separately stated taxes or network fees. Use the charges and rates on the relevant bill; a quoted example price is not a current tariff.

Under time-of-use pricing, calculate each period separately. A 3 kWh dryer cycle costs $0.90 at $0.30 per kWh, or $0.36 at $0.12 per kWh. Moving the cycle changes cost even though the cycle's energy stays at 3 kWh.

Compare an upgrade over the same service

Replacing a 50 W halogen lamp with a 6 W LED providing the required light saves 44 W, or 0.044 kW. At 4 h a day for 365 days, the time is 1,460 h:

ΔW=0.044×1460=64.24 kWh/year

At $0.18 per kWh, the yearly saving is 64.24×0.18=11.5632 dollars, about $11.56. If the LED costs $4.00 more to buy, simple payback is:

payback=4.0011.5632≈0.346 year

That is about 4.15 months. Compare the extra purchase price with the annual saving, not with annual energy in kWh.

Use a machine's electrical input

A 2.2 kW shaft-output motor at 85% efficiency needs 2.2/0.85=2.588… kW of electrical input at full load. Six hours uses about 15.5 kWh and costs about $2.80 at the example price. Using 2.2 kW directly would give about $2.38 and omit the motor's losses. If the machine operates at a different load or cycles, use its actual input and operating pattern for the cost.

Key Takeaways

  • Cost equals kWh used multiplied by the price per kWh.
  • Convert watts to kilowatts and cents to dollars before multiplying.
  • Add fixed charges separately and price time-of-use periods individually.
  • Compare appliances over the same useful service and operating time.
  • Simple payback is extra purchase cost divided by annual money saved.
  • Use electrical input power when costing a motor.

Ohm’s Law examples

5 Walkthroughs

1

Read a small DC load’s electrical values

16 steps
Connect units, charge flow and energy per coulomb, then distinguish meter connections and supply types.
  1. 1
    IntroductionGive each reading a meaning

    A small DC load has a voltage across it, a current through it and a running time. Those readings answer different questions: how much energy each coulomb transfers, how quickly charge moves, and how long the transfer continues. Start by reading the units, then connect the readings to charge and energy. You will also see why measuring current and measuring voltage need different meter connections.

  2. 2
    ExplanationRead the symbol after the number

    In “180 mA,” A names amperes and m makes the value one thousandth as large as the same number of amperes. The current is 0.180 A. In “2.2 kΩ,” k multiplies ohms by 1,000, giving 2,200 Ω.

    Case matters: m means milli, M means mega, and kilo uses lowercase k. Read the complete number, prefix and unit before choosing a formula.

  3. 3
    ExampleConvert the load’s readings

    A bench load draws 180 mA from 15 V for 3 minutes. Put the current and time into the units used by charge calculations:

    I=180×10−3=0.180 A t=3×60=180 s

    The voltage is already in volts. Keep the converted current separate from the original milliampere value so the calculator does not receive 180 A by mistake.

  4. 4
    TipSquare an area’s conversion factor

    An area conversion uses the length factor twice. Since 1 mm is one thousandth of a meter:

    1 mm2=(10−3)2 m2=10−6 m2

    For a 3 mm² conductor, write 0.000003 m² when the resistivity uses Ω·m. With resistivity in Ω·mm²/m, keep the area in mm² instead. Matching the unit set avoids an extra factor of one million.

  5. 5
    ChallengeConvert a control current

    A display gives 0.00024 A. What is this current in μA?

    ---reveal---

    It is 240 μA, because 0.00024/10−6=240. In engineering notation it is 240×10−6 A. Scientific notation for the same value is 2.4×10−4 A; the value has not changed, only how it is written.

  6. 6
    ExplanationCurrent counts charge passing a point

    Current is the amount of charge passing a point per second:

    I=Qt

    One ampere means one coulomb each second. In metal wires, free electrons carry charge; they drift opposite to conventional current. Circuit arrows follow conventional current from the source’s positive terminal through the external circuit toward its negative terminal.

  7. 7
    ExampleMultiply the rate by the running time

    For the bench load, current is 0.180 A and running time is 180 s. Rearrange the current definition:

    Q=It=0.180×180=32.4 C

    This is the charge magnitude that passes a chosen point during those three minutes. Multiplying 0.180 by 3 would account for only three seconds and give a result sixty times too small.

  8. 8
    Key InsightThe load takes energy, not current

    Charge continues around a complete path. In a single loop, the current leaving a load equals the current entering it. The load transfers energy, while charge keeps circulating.

    Opening the path stops current throughout that loop. Copper provides a conducting path with many mobile electrons; an insulating covering such as PVC helps keep that path separate from other conducting parts.

  9. 9
    ChallengeUse a charge capacity

    An ideal battery has 1.8 Ah of charge capacity. How long can it supply a steady 0.30 A?

    ---reveal---

    t=1.80.30=6 h

    Ampere-hours divided by amperes gives hours. One Ah is also 3,600 C. Real usable capacity depends on conditions, so this calculation describes the ideal capacity and constant current given.

  10. 10
    ExplanationVoltage gives energy per coulomb

    Voltage compares energy per charge between two points:

    V=WQ

    A 15 V supply gives an energy difference of 15 J per coulomb. It does not mean 15 C flows each second or that the source contains only 15 J. A source’s emf describes energy it supplies per coulomb; potential difference across a load describes energy transferred from electrical form.

  11. 11
    ExampleFind the energy transferred

    The bench load has 15 V across it and passes 32.4 C during its run. Each coulomb transfers 15 J:

    W=VQ=15×32.4=486 J

    The voltage and total charge together determine energy. If the same current continued for twice as long, twice the charge would pass and twice the energy would transfer, while the voltage could stay at 15 V.

  12. 12
    ConnectionPut each meter in the right place

    A voltmeter compares two points, so its leads connect across the load in parallel. Its high resistance keeps the current it draws small.

    An ammeter connects in series so the current passes through its low resistance. Putting that low resistance across a supply would create a near short circuit. The desired quantity determines the connection, even when both functions share one meter.

  13. 13
    ExplanationRead DC, AC and rms

    A DC source keeps its polarity. An AC source reverses polarity, with frequency counting complete cycles each second. Familiar mains examples are 230 V at 50 Hz and 120 V at 60 Hz.

    The AC voltage is an rms value: in a fixed resistor, it produces the same average heating as the same numerical DC voltage. That equivalence lets resistive-load calculations use rms values directly.

  14. 14
    ChallengeLook across an open switch

    A 12 V battery, an intact resistor and a switch form one loop. The switch is open. Can the switch have 12 V across it even though no current flows?

    ---reveal---

    Yes. The break stops loop current, but voltage can still exist across the break. With zero current, the intact resistor has no voltage drop. Voltage measures an energy difference between two points; it does not require charge to be moving at that moment.

  15. 15
    TipRead a voltage-band name carefully

    IEC-based extra-low voltage extends to 50 V AC rms or 120 V ripple-free DC. Low voltage extends above those limits to 1,000 V AC or 1,500 V DC.

    Household mains is called low voltage in this technical classification, but can still cause fatal shock. The band name describes voltage magnitude and must not be read as a statement that touching the conductors is safe.

  16. 16
    RecapKeep rate, charge and energy distinct

    Prefixes set the scale of a reading. Current is charge per second, so Q=It. Voltage is energy per coulomb, so W=VQ. Use the time and unit conversions before multiplying. Meter connections follow those meanings: current through the ammeter, voltage across the voltmeter’s two test points.

2

Use readings to explain a resistor and its faults

14 steps
Test constant resistance, calculate current and interpret open paths, shorts and poor contacts.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionBegin with a pair of readings
  2. 2
    ExplanationResistance is a ratio
  3. 3
    ExampleCompare two operating points
  4. 4
    Key InsightA lamp changes as it heats
  5. 5
    ChallengeCheck a resistor’s tolerance
  6. 6
    ExplanationChoose the unknown first
  7. 7
    ExampleCalculate a current and check it
  8. 8
    ChallengePredict two changes together
  9. 9
    ExplanationA break can hold the full voltage
  10. 10
    ExampleA low-resistance bypass draws a large current
  11. 11
    ConnectionA joint can conduct and still waste voltage
  12. 12
    ChallengeSeparate a zero-current reading from a short
  13. 13
    TipDo not read “OL” as zero
  14. 14
    RecapInterpret the state before predicting
3

Calculate a two-wire feed from size to voltage drop

13 steps
Use material, area, temperature and total length to calculate resistance and delivered voltage.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionFollow both conductors
  2. 2
    ExplanationSeparate resistivity from resistance
  3. 3
    ExampleCompare changes in shape
  4. 4
    ExampleCorrect for the temperature rise
  5. 5
    ChallengeUse diameter and length together
  6. 6
    ExplanationBuild the conductor formula
  7. 7
    ExampleRead the feed’s dimensions
  8. 8
    ExampleCalculate total feed resistance
  9. 9
    ExampleFind the voltage reaching the load
  10. 10
    TipFind area from diameter first
  11. 11
    ChallengeCompare a longer feed with thicker wire
  12. 12
    ConnectionUse a limit to calculate area
  13. 13
    RecapMove from dimensions to delivered voltage
4

Connect power, heating and a machine’s output

15 steps
Calculate resistor power and contact heat, then follow efficiency from a DC motor to useful motion.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionTrack where the power goes
  2. 2
    ExplanationChoose a form from the known values
  3. 3
    ExampleUse the rated conditions
  4. 4
    ChallengeReduce the voltage
  5. 5
    TipUse the cable’s own electrical values
  6. 6
    ExplanationHeat follows current squared
  7. 7
    ExampleCalculate a contact’s heat
  8. 8
    ConnectionCooling determines the resulting temperature
  9. 9
    ChallengeHold the correct quantity fixed
  10. 10
    ExplanationDistinguish input from useful output
  11. 11
    ExampleFind a DC motor’s electrical input
  12. 12
    ExamplePass the shaft power through a gearbox
  13. 13
    ExplanationCalculate useful power in a lift
  14. 14
    ChallengeWork backward from useful power
  15. 15
    RecapFollow rates through the machine
5

Turn an operating schedule into energy and cost

13 steps
Calculate on-time, kWh, a bill and the payback of a lower-power replacement.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart from the operating schedule
  2. 2
    ExplanationMatch the energy unit to the time
  3. 3
    ExampleConvert a short operating period
  4. 4
    ExampleCount an element’s actual on-time
  5. 5
    ChallengeUse two meter readings
  6. 6
    ConnectionInclude voltage in battery energy
  7. 7
    ExplanationApply the energy price
  8. 8
    ExampleAdd a daily fixed charge
  9. 9
    ChallengePrice each time period
  10. 10
    ExampleCalculate a replacement’s annual saving
  11. 11
    ChallengeFind when the extra price is recovered
  12. 12
    TipCost the input that actually runs the machine
  13. 13
    RecapKeep energy and charges in separate steps

Ohm’s Law practice questions

40 Practice Questions in 4 sets

Set 1: Read values and use the core relationships10 Practice Questions

Question 1 of 10

A control drawing labels a resistance as 3.3 kΩ. What is its value in ohms?
  1. 0.0033 Ω
  2. 330 Ω
  3. 3,300 Ω
  4. 33,000 Ω
Show answerHide answer
Answer: C
Kilo multiplies the unit by 1,000, so 3.3×1000=3300 Ω. The value 330 Ω uses a factor of 100 instead of 1,000.

Question 2 of 10

A steady 0.8 A flows through a pump for 2.5 minutes. What charge magnitude passes a point in the wire?
  1. 120 C
  2. 2.00 C
  3. 32.0 C
  4. 200 C
Show answerHide answer
Answer: A
The time is 2.5×60=150 s, so Q=0.8×150=120 C. A result of 2.00 C treats the number of minutes as seconds. Since an ampere is one coulomb per second, the time used with amperes must be in seconds to obtain charge in coulombs.

Question 3 of 10

A component has 7.5 V across it and carries 0.25 A. What is its resistance at this operating point?
  1. 1.875 Ω
  2. 0.0333 Ω
  3. 1.00 Ω
  4. 30.0 Ω
Show answerHide answer
Answer: D
Resistance is voltage divided by current, giving R=7.5/0.25=30.0 Ω at this operating point. Multiplying 7.5 by 0.25 gives 1.875 W, which is power instead of resistance.

Question 4 of 10

A lamp carries 0.20 A at 3 V and 0.30 A at 6 V. How has its resistance changed between these readings?
  1. It stayed at a value of 15 Ω.
  2. It rose from 15 Ω to 20 Ω.
  3. It fell from 20 Ω to 15 Ω.
  4. It rose from 15 Ω to 30 Ω.
Show answerHide answer
Answer: B
The first ratio is 3/0.20=15 Ω and the second is 6/0.30=20 Ω. Its resistance increased, consistent with a warming filament. A final value of 30 Ω would follow from doubling the original resistance without calculating the actual second voltage-to-current ratio.

Question 5 of 10

A uniform wire is replaced by one of the same material, length and temperature but twice the cross-sectional area. How does its resistance change?
  1. It becomes twice as large.
  2. It becomes one quarter as large.
  3. It becomes one half as large.
  4. It stays at its original value.
Show answerHide answer
Answer: C
Resistance is inversely proportional to cross-sectional area when material, length and temperature stay fixed. Doubling area therefore halves resistance. One quarter would follow from doubling the diameter of circular wire, because that change makes the area four times as large.

Question 6 of 10

A 24 V source supplies a load 25 m away through two copper conductors, each 2.5 mm². The load current is 6 A. With ρ = 0.0172 Ω·mm²/m, what voltage reaches the load?
  1. 23.0 V
  2. 24.0 V
  3. 19.9 V
  4. 21.9 V
Show answerHide answer
Answer: D
Current travels through 50 m of conductor, giving R=0.0172×50/2.5=0.344 Ω. The drop is 6×0.344=2.064 V, so the load receives about 21.9 V. Using only the 25 m outward distance halves the drop and produces about 23.0 V.

Question 7 of 10

A resistive load has 48 V across it and carries 2.5 A. What power does it receive?
  1. 120 W
  2. 19.2 W
  3. 50.5 W
  4. 300 W
Show answerHide answer
Answer: A
Electrical power is voltage times current, so P=48×2.5=120 W. Dividing voltage by current gives 19.2 Ω, the resistance, not the power.

Question 8 of 10

The current through a fixed contact resistance rises from 4 A to 12 A. By what factor does its heating power rise?
  1. 3
  2. 9
  3. 6
  4. 12
Show answerHide answer
Answer: B
The current becomes three times as large, while Joule heating depends on current squared. The heating factor is therefore 32=9 for the unchanged contact resistance. A factor of three would treat heating as directly proportional to current and miss the second current factor in P=I2R.

Question 9 of 10

A 1,200 W drying element runs continuously for 35 minutes. How much energy does it use?
  1. 0.420 kWh
  2. 42.0 kWh
  3. 0.700 kWh
  4. 7.00 kWh
Show answerHide answer
Answer: C
Power is 1.2 kW and time is 35/60 h, so energy is 1.2×35/60=0.700 kWh. The value 0.420 kWh treats 35 minutes as 0.35 h. Minutes describe sixtieths of an hour, so their conversion requires division by 60.

Question 10 of 10

A soldering station draws 80 W for 5 h a day over 20 days. At $0.18 per kWh, what is its energy cost?
  1. $1.44
  2. $0.72
  3. $7.20
  4. $14.40
Show answerHide answer
Answer: A
The station runs for 5×20=100 h and uses 0.080×100=8 kWh. Its cost is 8×0.18=1.44 dollars. A cost of $14.40 is ten times too large and can result from treating 80 W as 0.8 kW instead of 0.080 kW.
Set 2: Interpret measurements and operating conditions10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A disconnected 18 V battery supplies no current. What does the 18 V reading between its terminals mean?
  1. 18 C would pass every second in a closed path.
  2. Each coulomb has an energy difference of 18 J.
  3. The battery stores a total energy of 18 J.
  4. Each second transfers 18 J without a load.
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A cable calculation uses resistivity in Ω·m. What area in m² represents 6 mm²?
  1. 6×10−3 m²
  2. 6×106 m²
  3. 6×10−9 m²
  4. 6×10−6 m²
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

In a single loop, an ideal 36 V source feeds an intact resistive load and a switch. The switch is open. What voltage is across the load and across the switch?
  1. 36 V across each
  2. 18 V across each
  3. 0 V load; 36 V switch
  4. 36 V load; 0 V switch
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A fixed 3.6 kΩ resistor carries 5.0 mA. What voltage is across it?
  1. 18.0 V
  2. 0.018 V
  3. 720 V
  4. 1,800 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A two-wire 48 V feed must deliver at least 46.8 V while carrying 10 A to a load 18 m away. Copper has ρ = 0.0172 Ω·mm²/m. What is the smallest area among 2.5, 4, 6 and 10 mm² that meets this voltage-drop requirement?
  1. 2.5 mm²
  2. 6 mm²
  3. 4 mm²
  4. 10 mm²
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A copper winding measures 8.00 Ω at 20 °C. Using α = 0.00393 per °C, what is its approximate resistance at 60 °C?
  1. 8.31 Ω
  2. 9.89 Ω
  3. 9.26 Ω
  4. 11.1 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A DC motor delivers 640 W at 80% efficiency. What electrical input power does it need?
  1. 512 W
  2. 160 W
  3. 1,440 W
  4. 800 W
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A fixed-resistance heater is rated 1,000 W at 200 V. What power does it produce at 180 V?
  1. 810 W
  2. 900 W
  3. 1,110 W
  4. 1,230 W
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

Why does a cable reel usually have a lower permitted load while coiled than while fully unwound?
  1. Coiling increases the conductor length.
  2. The wound cable releases heat less easily.
  3. Coiling reduces the copper cross-section.
  4. The wound cable always draws more current.
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A 1.8 kW thermostatic heater is observed for 4 h. Its element is on for 25% of the first 2 h and 75% of the next 2 h. What energy does it use in the full period?
  1. 1.8 kWh
  2. 5.4 kWh
  3. 3.6 kWh
  4. 7.2 kWh
Show answerHide answer

Save this lesson to see this answer.

Set 3: Connect cable losses, power and useful output10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A battery has an ideal charge capacity of 4.5 Ah. A constant load draws 0.75 A. How long would the battery supply it ideally?
  1. 3.38 h
  2. 0.167 h
  3. 4.50 h
  4. 6.00 h
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

The same fixed resistor is supplied first by 24 V DC, then by 24 V rms AC. How does its average heating power compare?
  1. It is the same for both supplies.
  2. It is twice as large on AC.
  3. It is one half as large on AC.
  4. It is zero over a full AC cycle.
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A fixed resistor’s applied voltage is tripled without changing its temperature. How does its current change?
  1. It falls to one third.
  2. It becomes three times as large.
  3. It becomes nine times as large.
  4. It stays at its original value.
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A conducting contact has 0.90 V across it while 15 A passes through it. What contact resistance do these readings indicate?
  1. 16.7 Ω
  2. 13.5 Ω
  3. 0.060 Ω
  4. 0.0060 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A uniform copper wire is 12 m long and 1.0 mm in diameter. With ρ = 0.0172 Ω·mm²/m, what voltage is lost along this one wire at 4.0 A?
  1. 0.263 V
  2. 2.10 V
  3. 0.826 V
  4. 1.05 V
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Wire B has the same material and temperature as wire A, but is twice as long and has 1.5 times its diameter. If wire A has resistance 0.90 Ω, what is wire B’s resistance?
  1. 0.80 Ω
  2. 1.20 Ω
  3. 0.40 Ω
  4. 2.70 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A uniform copper feed carrying a regulated 10 A loses 20 W in its conductors. The conductors are replaced with ones of the same material and length but twice the area, and current becomes 15 A. What is the new conductor heating power?
  1. 15.0 W
  2. 30.0 W
  3. 22.5 W
  4. 45.0 W
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 24 V DC drive must deliver 432 W after a gearbox. The motor is 80% efficient and the gearbox is 90% efficient. What current must the supply provide?
  1. 14.4 A
  2. 20.0 A
  3. 22.5 A
  4. 25.0 A
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A 200 Ω resistor carries 0.030 A. What power does it dissipate?
  1. 0.18 W
  2. 0.006 W
  3. 6.0 W
  4. 18 W
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

An energy bill lists 180 kWh at $0.18 per kWh plus a fixed charge of $0.35 per day for 28 days. No other charges apply. What is the total?
  1. $32.40
  2. $42.20
  3. $38.70
  4. $49.00
Show answerHide answer

Save this lesson to see this answer.

Set 4: Solve combined workshop and energy problems10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A fixed-resistance load draws 0.40 A from 24 V. A replacement load has 1.5 times that resistance and is operated at 36 V. What current does the replacement draw?
  1. 0.60 A
  2. 0.267 A
  3. 0.90 A
  4. 0.40 A
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 12 V source has 0.08 Ω internal resistance. A short forms through leads with 0.04 Ω resistance. The total fault path includes both. What is the prospective fault current?
  1. 300 A
  2. 100 A
  3. 150 A
  4. 1.44 A
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A two-wire copper feed serves a load 30 m away at 8 A. Its 2.5 mm² conductors have ρ = 0.0172 Ω·mm²/m. What minimum supply voltage is needed to provide 24 V at the load?
  1. 25.7 V
  2. 24.4 V
  3. 27.3 V
  4. 30.6 V
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A current is written as 0.000056 A. How is the same current written in microamperes?
  1. 0.056 μA
  2. 5.6 μA
  3. 56 μA
  4. 560 μA
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

An ideal battery starts with 3.6 Ah of charge capacity. It supplies 0.60 A for 2 h, then 1.20 A. How long can it supply the second current before its capacity is used?
  1. 1.00 h
  2. 2.00 h
  3. 3.00 h
  4. 4.00 h
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A source transfers 144 J while moving 12 C through a load. What voltage is across the load?
  1. 1,728 V
  2. 0.0833 V
  3. 132 V
  4. 12.0 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

What measured behavior supports calling a metallic component ohmic at constant temperature?
  1. Its current-to-voltage ratio stays constant.
  2. Its current stays constant as voltage changes.
  3. Its resistance rises in proportion to voltage.
  4. Its current rises in proportion to voltage squared.
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A hoist lifts 80 kg through 5 m in 8 s at steady speed. Its motor is 75% efficient and its gearbox is 90% efficient. Using g = 9.81 N/kg, what electrical input power is required for the lift?
  1. 727 W
  2. 654 W
  3. 545 W
  4. 491 W
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

Two ideal batteries each have capacity 15 Ah. One is 12 V and the other 24 V. How much more energy does the 24 V battery store?
  1. 0.180 kWh
  2. 0.015 kWh
  3. 0.360 kWh
  4. 0.540 kWh
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

Two machines provide the same 1.20 kW useful output for 600 h per year. Their efficiencies are 75% and 90%. The more efficient machine costs $72 more. At $0.18 per kWh, what is its simple payback time?
  1. 3.70 years
  2. 2.78 years
  3. 2.50 years
  4. 3.33 years
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

70 Key Terms, each with its definition

A

Alternating current supply
An alternating current supply repeatedly reverses its polarity, with its frequency in hertz stating the number of complete cycles per second.
A 50 Hz mains supply completes 50 cycles each second as its voltage alternates.
Ammeter
An ammeter is an instrument that measures current by being connected in series with the path, with low internal resistance.
To measure a load’s current, the meter is placed so that the load current passes through it.
Ampere-hour
An ampere-hour is a unit of charge equal to a steady current of one ampere for one hour, corresponding to 3,600 coulombs.
A 4 Ah battery could ideally supply 1 A for 4 h, with actual usable capacity depending on conditions.
Annual saving
An annual saving is the reduction in energy use or cost over one year when two options are compared for the same useful service.
A reduction of 60 kWh per year saves $10.80 annually at an illustrative $0.18 per kWh.

C

Circuit breaker
A circuit breaker is a protective switching device that interrupts excess current; typical designs use thermal overload and magnetic short-circuit responses.
A large short-circuit current triggers a typical breaker’s rapid magnetic response.
Conductance
Conductance is the reciprocal of resistance and describes how readily a component conducts current, with the SI unit siemens.
A component of resistance 100 Ω has conductance 0.010 S, found by taking its reciprocal.
Conductor
A conductor is a material in which electric charge moves readily; metal conductors such as copper have many free electrons.
Copper carries current inside a cable while its outer covering separates the conductor from nearby parts.
Contact resistance
Contact resistance is the resistance at a joint between conducting parts, which can cause local voltage loss and heating while current flows.
A corroded terminal with 0.05 Ω contact resistance loses 0.5 V while carrying 10 A.
Continuity
Continuity is an unbroken conducting path between test points, often indicated by a low resistance when tested on an isolated circuit.
An isolated intact wire gives a low resistance reading between its two ends.
Conventional current
Conventional current is the assigned direction of current from positive to negative through an external circuit, opposite to electron drift in metals.
A circuit arrow points away from a battery’s positive terminal along the external conducting path.
Coulomb
A coulomb is the SI unit of electric charge, equal to the charge magnitude passing a point in one second at a steady current of one ampere.
At a steady 3 A, 3 C passes a point in each second and 30 C passes in ten seconds.
Cross-sectional area
Cross-sectional area is the area of a cut perpendicular to a conductor’s length, measured in m² or commonly in mm² for cables.
A 4 mm² conductor has more conducting area than a 2.5 mm² conductor of the same material.
Cumulative meter reading
A cumulative meter reading is the total energy recorded by an electricity meter up to that time, usually shown in kilowatt-hours.
Readings of 8,100 and 8,175 kWh show that 75 kWh was used between the readings.
Current-carrying capacity
Current-carrying capacity is the current a conductor can carry under stated installation conditions while staying within its temperature limit.
Bundling cables or surrounding them with thermal insulation reduces their permitted current.

D

Direct current supply
A direct current supply maintains the same polarity between its terminals, as in a battery, solar panel or DC power supply.
A tool battery has designated positive and negative terminals that keep their polarity during use.
Direct proportion
Direct proportion means two quantities change by the same factor while their ratio stays constant under the stated conditions.
For a fixed resistor, increasing applied voltage by 50% increases current by 50%.

E

Efficiency
Efficiency is the ratio of useful output power or energy to input power or energy, expressed as a decimal or a percentage.
A motor delivering 600 W from 750 W of electrical input has an efficiency of 80%.
Electric charge
Electric charge is a property of particles that can be positive or negative and is measured in coulombs; electrons carry negative charge.
A group of moving electrons carries a negative charge even when its charge magnitude is quoted as positive.
Electric current
Electric current is the rate at which charge passes a point in a circuit, measured in amperes, with one ampere equal to one coulomb per second.
A current of 0.5 A moves 15 C past a point during a 30 s interval.
Electrical energy
Electrical energy is the amount transferred during operation, equal to power multiplied by operating time when power is constant.
A 100 W load running for 30 s transfers 3,000 J of energy.
Electromotive force
Electromotive force is the energy a source supplies per coulomb of charge by converting another form of energy into electrical form.
A battery’s emf describes chemical energy supplied per coulomb, and its unit is the volt.
Energy charge
An energy charge is the part of an electricity bill calculated from the kilowatt-hours used multiplied by the applicable price per kilowatt-hour.
At $0.18 per kWh, 50 kWh creates an energy charge of $9.00 before fixed or other charges.
Engineering notation
Engineering notation writes a value using a power of ten whose exponent is a multiple of three, matching common SI prefixes.
A current of 0.00039 A can be written as 390×10−6 A, or 390 μA.
Extra-low voltage
Extra-low voltage is an IEC-based voltage band extending up to 50 V AC rms or 120 V ripple-free DC between the relevant points.
A 24 V DC control supply falls within the extra-low-voltage band in this classification.

F

Fixed charge
A fixed charge is a billed amount that does not depend on energy consumed, often calculated as a daily rate times the billing days.
A fixed rate of $0.40 per day contributes $12.00 over a 30-day billing period.
Fuse
A fuse is a protective device whose element melts after sufficient excess-current heating, breaking the current path in the circuit.
A fuse that has melted leaves an open path and must not be treated as a conducting link.

H

Hot spot
A hot spot is a small region at a higher temperature than nearby parts, often caused by concentrated heating at a poor electrical contact.
A thermal image can show one terminal much hotter than the neighboring sound terminals.

I

Input power
Input power is the rate at which energy enters a machine or component, providing both useful output and losses during operation.
A 900 W shaft output at 90% efficiency requires 1,000 W of electrical input.
Insulator
An insulator is a material with very high electrical resistivity that is used to separate conductors and restrict current through unwanted paths.
PVC around a cable conductor keeps the metal separated from other conducting surfaces.
Inverse proportion
Inverse proportion means one quantity changes by the reciprocal factor of another while their product remains constant.
At fixed voltage, tripling resistance reduces current to one third of its original value.

J

Joule heating
Joule heating is the conversion of electrical energy into heat in a resistance carrying current, at a rate given by current squared times resistance.
A contact of 0.2 Ω carrying 5 A produces 5 W of heat at the joint.

K

Kilowatt-hour
A kilowatt-hour is a unit of energy equal to one kilowatt sustained for one hour, corresponding to 3.6 million joules.
A 0.5 kW appliance operating for 4 h uses 2 kWh of energy.

M

Mechanical work
Mechanical work is energy transferred by a force acting through a distance in the force’s direction, measured in joules.
A steady 100 N lifting force acting through 2 m transfers 200 J of mechanical energy.
Micro
Micro is the prefix for one millionth of a unit, written with the symbol μ and corresponding to the factor 10−6.
A sensor current of 45 μA can be entered as 0.000045 A when a calculation needs amperes.
Minimum conductor area
A minimum conductor area is the smallest calculated cross-section that meets a stated resistance or voltage-drop requirement under specified conditions.
If a calculation requires at least 3.2 mm², a listed 4 mm² size meets that area requirement.

N

Non-ohmic component
A non-ohmic component does not keep a constant voltage-to-current ratio as operating conditions change, so its current–voltage plot is not one straight line through the origin.
A lamp’s hot filament has a larger resistance than its cold filament, changing the current–voltage relationship.
NTC thermistor
An NTC thermistor is a temperature-sensitive resistor with a negative temperature coefficient, so its resistance decreases as it warms.
A temperature-sensing NTC thermistor falls in resistance while a copper conductor rises in resistance.

O

Ohm’s law
Ohm’s law states that current in a metallic conductor at constant temperature is directly proportional to the voltage across it.
Doubling voltage across a fixed-temperature metal resistor doubles its current.
Ohmic component
An ohmic component has a constant resistance over the conditions considered, so its current is directly proportional to its applied voltage.
A resistor drawing 0.1 A at 5 V and 0.2 A at 10 V shows the same 50 Ω resistance at both settings.
On-time fraction
An on-time fraction is the share of an observation period during which a cycling load is powered, used to calculate its actual operating time.
An element on for 40% of a 10 h period operates for 4 h at its on-state power.
Open circuit
An open circuit is a break in a conducting path that stops current in a simple loop even though voltage can remain across the break.
With a switch open in a single lamp loop, the switch can have supply voltage across it.
Operating point
An operating point is a particular combination of voltage and current at which a component is working and its resistance can be calculated.
A lamp at 8 V and 0.4 A has a resistance of 20 Ω at that operating point.
Over-range indication
An over-range indication means a measured value exceeds an instrument’s selected range; an ohmmeter may show “OL” for a very high resistance.
A broken wire can give an “OL” resistance reading, whereas an intact low-resistance path reads near zero.
Overall efficiency
Overall efficiency is the fraction of the initial input reaching the final useful output through several stages, found by multiplying stage efficiencies.
An 80% efficient motor followed by a 90% efficient gearbox has an overall efficiency of 72%.
Overload
An overload is a condition in which current through a load exceeds the current that the circuit or equipment was designed to carry.
A jammed machine can draw excessive current while current still passes through its motor.

P

Positive temperature coefficient
A positive temperature coefficient means resistance rises as temperature rises over the temperature interval being considered.
A warm copper winding measures a higher resistance than the same winding at 20 °C.
Potential difference
Potential difference is the energy transferred per unit charge between two points, measured in volts, with one volt equal to one joule per coulomb.
A load receiving 20 J as 4 C passes has a potential difference of 5 V across it.
Power
Power is the rate of energy transfer, measured in watts, with one watt equal to one joule transferred in each second.
A 500 W element transfers 500 J each second while it operates at that power.
Power dissipation
Power dissipation is the rate at which a component transfers electrical energy into heat, which must remain within its thermal capability.
A resistor dissipating 0.12 W has a calculated heat rate below a 0.25 W rating under the rated conditions.
Power loss
Power loss is the difference between input power and useful output power, transferred into unwanted forms such as heat, friction and sound.
A motor taking 1,000 W and delivering 850 W has 150 W of power loss.

Q

Quantity symbol
A quantity symbol is a letter used to represent a physical quantity in a formula, such as I for current or R for resistance.
In the formula V=IR, R represents resistance, while Ω after a number names its unit.

R

Rated power
Rated power is the specified power of a device at its stated operating conditions; a resistive heater’s rating is tied to its rated voltage.
A fixed-resistance heater supplied below rated voltage produces less than its rated power.
Rating plate
A rating plate states equipment ratings such as voltage, power and current for specified operating conditions, identifying its intended use.
A resistive heater marked “120 V 900 W” draws 7.5 A at its stated operating voltage.
Resistance
Resistance is the ratio of voltage across a component to current through it at an operating point, measured in ohms.
A component carrying 0.5 A with 10 V across it has a resistance of 20 Ω at that point.
Resistance tolerance
Resistance tolerance is the permitted difference between a resistor’s measured resistance and its nominal value, usually expressed as a percentage.
A 100 Ω resistor marked ±5% may measure from 95 Ω to 105 Ω and still meet its tolerance.
Resistivity
Resistivity is a material property at a stated temperature that relates a conductor’s resistance to its length and cross-sectional area.
Copper at 20 °C has resistivity about 0.0172 Ω·mm²/m for calculations using area in mm².
Rms voltage
Rms voltage is the AC voltage value that produces the same average heating in a fixed resistor as an equal numerical DC voltage.
A fixed resistor has the same average heating at 12 V rms AC and at 12 V DC.

S

Scientific notation
Scientific notation expresses a nonzero number as a value from 1 up to, but not including, 10 multiplied by an integer power of ten.
A resistance of 56,000 Ω is 5.6×104 Ω when written in scientific notation.
Short circuit
A short circuit is a very low-resistance path that bypasses a load and can allow a large current limited by the source and path resistances.
A damaged cable creating a low-resistance bypass can draw much more than the normal load current.
SI unit
An SI unit belongs to the International System of Units, which provides a consistent basis for stating and calculating physical quantities.
A technician writes current in amperes and time in seconds before calculating charge in coulombs.
Simple payback time
Simple payback time is the extra purchase cost of an upgrade divided by its annual money saving, giving the years needed to recover that extra cost.
An upgrade costing $45 extra and saving $15 each year has a simple payback of three years.

T

Temperature coefficient of resistance
A temperature coefficient of resistance describes the fractional change in resistance per degree of temperature change near a reference temperature.
Using 0.00393 per °C for copper predicts an increase in resistance when a winding warms above 20 °C.
Time-of-use tariff
A time-of-use tariff charges different prices per kilowatt-hour in different time periods, so cost depends on when energy is used.
Running a 2 kWh cycle in a cheaper period lowers its cost without changing its energy use.
Total conductor length
Total conductor length is the combined length of the current-carrying conductors included in a resistance calculation, including the return path.
A two-wire feed to a load 22 m away includes 44 m of outgoing and return conductor.

U

Unit prefix
A unit prefix multiplies a unit by a stated power of ten, allowing very small or large values to be written with convenient numbers.
The prefix kilo in 6.8 kΩ makes the resistance 6,800 Ω without changing the quantity being measured.
Useful output power
Useful output power is the rate at which a machine supplies the intended form of energy, such as mechanical power delivered at a motor shaft.
The useful output of a hoist is the rate at which it increases the lifted load’s gravitational energy.

V

Voltage drop
Voltage drop is the potential difference along a current-carrying resistance, equal to the current multiplied by that resistance.
A cable carrying 5 A through 0.2 Ω loses 1 V between the supply and the load terminals combined.
Voltmeter
A voltmeter is an instrument that measures potential difference between two points and connects in parallel with high internal resistance.
The two meter leads touch opposite ends of a load to compare their potentials.

W

Watt-hour
A watt-hour is a unit of energy equal to one watt sustained for one hour, with 1,000 watt-hours making one kilowatt-hour.
A 12 V battery of 8 Ah has approximately 96 Wh of stored energy before practical limits are applied.
Wire diameter
Wire diameter is the distance across a circular conductor through its center, equal to twice the radius used in calculating its area.
For a 2 mm diameter conductor, use a 1 mm radius when finding the circular cross-sectional area.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started