Magnetism and Electromagnetic Induction
BeginnerLesson 3 of 7 in Electrical Principles for Technicians Course
What you will learn
- Describe the field around a magnet with poles and field lines, measure it as flux and flux density, and explain how materials are magnetized, keep their magnetism and lose it.
- Describe magnets, poles and field linesUse poles, attraction and repulsion, and field-line diagrams to describe the magnetic field around permanent magnets.
- Calculate magnetic flux and flux densityUse magnetic flux in webers and flux density in teslas, and calculate one from the other with Φ = B × A.
- Explain magnetizing, demagnetizing and remanent magnetismExplain why some materials are easily magnetized, choose soft or hard magnetic materials for a job, and describe remanence, saturation and how magnetism is removed.
- Describe magnets, poles and field lines
- Find the field around a straight conductor and a coil, and explain what sets the strength of an electromagnet and how solenoids and electromagnets are used in equipment.
- Find the field around a conductor and a coilDraw the circular field around a straight conductor and the bar-magnet field of a coil, and find directions and poles with the right-hand grip rule.
- Explain what makes an electromagnet strongUse ampere-turns, magnetic field strength and permeability to explain and calculate how current, turns, core material and air gaps affect an electromagnet.
- Explain how solenoids and electromagnets work in equipmentExplain the action of solenoid actuators, lifting magnets and magnetic trips, and the differences between DC and AC electromagnets.
- Find the field around a conductor and a coil
- Describe the parts and contacts of relays and contactors, read their terminal markings, follow simple control circuits and check that a relay or contactor suits its job.
- Explain how a relay worksDescribe a relay's coil, armature and contacts, and explain how a small control current switches a separate, larger load current.
- Explain contactors and self-holding control circuitsDistinguish contactors from relays, read contactor terminal markings, and explain how start and stop buttons with a holding contact control a load safely.
- Choose and check relays and contactorsMatch a relay or contactor to its supply and load, recognize the signs of common faults, and test coils and contacts safely.
- Explain how a relay works
- Calculate the force on a conductor in a magnetic field, find its direction, and explain how the motor effect drives motors, loudspeakers and meters and stresses busbars.
- Calculate the size and direction of the forceUse F = B × I × l to calculate the force on a conductor and Fleming's left-hand rule to find its direction.
- Explain the motor effect in machines, speakers and busbarsExplain how the motor effect turns a coil, drives loudspeakers and moving-coil meters, and produces large forces between conductors carrying fault currents.
- Calculate the size and direction of the force
- Explain how a changing magnetic field induces a voltage, calculate induced voltages, find their direction, and apply induction to generators, coupled coils, eddy currents and sensors.
- Explain and calculate induced voltageUse Faraday's and Lenz's laws and Fleming's right-hand rule to predict when a voltage is induced, how large it is and which way the current flows.
- Apply induction in generators, coupled coils, eddy currents and sensorsExplain how a simple generator produces an alternating voltage and how mutual induction, eddy currents and induction sensors work in equipment.
- Explain and calculate induced voltage
- Explain how a coil opposes changes in its own current, calculate inductance, induced voltage, stored energy and time constant, and protect contacts and electronics when inductive loads are switched off.
- Explain and calculate self-inductanceDefine inductance and the henry, explain the back emf of a coil, and calculate induced voltage, stored energy and the time constant of an inductive DC circuit.
- Control voltage spikes when switching inductive loadsExplain why breaking an inductive circuit causes a voltage spike and arcing, how ignition coils and lamp chokes use it, and how diodes, RC snubbers and varistors suppress it.
- Explain and calculate self-inductance
Magnetism and Electromagnetic Induction study guide
1Magnetic fields and materials
An invisible field explains why a magnet pulls steel, why a compass turns and why pole faces concentrate magnetic effects. Learn to read that field with poles and field lines, then distinguish total flux from flux density through a measured area. The behavior of magnetic materials completes the picture: some serve as permanent magnets, while others make cores whose magnetism can be changed easily by a coil.
1.1 Read a magnetic field
A magnet can pull an unmagnetized steel part toward either end. Bring two magnets together and a second behavior appears: they can push apart. These forces help identify poles and make sense of a field drawing.
Poles and magnetic materials
Every magnet has a north pole (N) and a south pole (S). Like poles repel; unlike poles attract. The magnetic effect is strongest near the poles. Cutting a bar magnet makes two smaller magnets, each with its own N and S. It does not separate north from south.
Attraction alone cannot identify a magnet: an ordinary piece of iron is attracted by either pole. Repulsion gives the useful test. If a known magnet repels an object, that object is also a magnet, presenting the same kind of pole.
Iron, ordinary steel, nickel and cobalt are strongly attracted. Copper, aluminum, brass and common austenitic stainless steels such as grade 304 are only weakly affected in this test. A metal object need not be strongly magnetic just because it conducts electricity.
What the lines show
A magnetic field is the region in which magnetic forces act. Field lines are a drawing model, not threads in space. Their arrows show where the north end of a small compass points; their spacing shows relative strength.
- Outside a magnet, lines run from N to S.
- Inside it, they continue from S to N, making closed loops.
- Lines never cross: the field has one direction at each point.
- Closer lines show a stronger field.
Around a bar magnet, lines curve from one pole to the other. Across a narrow gap between unlike poles, they can be nearly straight, parallel and evenly spaced: a nearly uniform field. Between facing like poles, the patterns bend away from each other. With identical magnets placed symmetrically, their equal opposing fields cancel at the midpoint, creating a neutral point.
Use a compass to add direction
To plot a field, place a compass at a point, mark the needle's N-end direction, then move it a short distance along that direction. Repeat and join the marks smoothly. Start again from other positions to build the pattern. Iron filings reveal a pattern too, but their shapes alone do not supply arrows.
For example, a compass to the right of a bar magnet's S pole points left, toward that pole. This follows the outside N-to-S direction. The compass's north end is attracted to the magnet's south end.
Earth's surface field is roughly 25–65 µT. The magnetic pole near geographic north behaves as a magnetic south pole, which attracts the compass's N end. Geographic and magnetic pole names describe different things.
Guide a field around equipment
Air, wood, plastic and copper allow a steady magnetic field through with little change. A soft-iron or special-alloy screen gives flux an easier path around a protected space. A plastic cover can prevent contact with a magnet, but it does not provide the magnetic screening of a suitable iron enclosure.
Key Takeaways
- Like poles repel and unlike poles attract; repulsion identifies a magnet.
- Field lines form closed loops and run N to S outside a magnet.
- Line spacing shows relative field strength; arrows show compass direction.
- Equal opposing fields cancel at a neutral point.
- Magnetic screening redirects flux through a suitable magnetic material.
1.2 Flux, flux density and area
A wide magnetic pole face may carry more total field than a narrow one without having a more concentrated field. Flux and flux density describe these two different quantities.
Total field and concentration
Magnetic flux, , is the total magnetic field passing through an area. Its SI unit is the weber (Wb). A milliweber is not a separate kind of field: 1 mWb is 0.001 Wb. A microweber is 0.000001 Wb.
Flux density, , is the flux per square meter measured across the field. Its unit is the tesla (T); 1 T equals 1 Wb/m². A high flux density means the field is concentrated. Two cores can carry the same flux but have different flux densities if their cross-sectional areas differ.
For a uniform field perpendicular to an area:
Use teslas, webers and square meters in these forms. Increasing area at fixed flux density increases total flux. Increasing area at fixed total flux reduces flux density. Identify which quantity stays fixed before predicting a change.
Convert the area first
Area conversions are squared length conversions:
A pole face 25 mm by 20 mm can be converted two ways. Convert the sides to 0.025 m and 0.020 m and multiply, or calculate 500 mm² and multiply by one millionth. Both give:
At 0.8 T, the flux is:
Using 0.001 as the conversion factor for mm² would make the area 1,000 times too large. That factor converts millimeters to meters, not square millimeters to square meters.
Work backward from flux
A core carries 1.2 mWb through 15 cm². Convert both quantities before dividing:
A quick unit check helps: webers divided by square meters must give teslas. Dividing area by flux reverses that relationship and gives the wrong unit.
Orientation and scale
The simple product uses the area facing directly across the field. Tilt the face and less flux passes through it. Turn it until its plane lies along the lines and no flux passes through that face, even though a field is still present.
Earth's field is about 50 µT, or 0.00005 T. A fridge magnet has a few millitesla at its surface; a motor or relay air gap may have roughly 0.5–1 T. Common hospital MRI scanners use 1.5–3 T. These values show why the unit prefix matters: 50 µT is a very different field from 50 mT.
Key Takeaways
- Flux is total field through an area; flux density is flux per square meter.
- Use Φ = BA for a uniform field perpendicular to the area.
- Convert both area dimensions, or square the length conversion factor.
- Tilting an area changes the flux through it.
1.3 Choose and change magnetic materials
The same magnetic field can leave one material strongly magnetized and another easy to demagnetize. This difference matters when choosing a permanent magnet or a core that must respond to a changing current.
A domain model
Ferromagnetic materials include iron, nickel, cobalt and many of their alloys. They contain tiny magnetic regions called domains. In an unmagnetized piece their effects largely cancel. An applied field lines many domains up, so their contributions add.
Stroking a suitable material with a magnet, placing it inside an energized coil or exposing it to a strong field can magnetize it. Eventually the domains that can align have done so. The material is saturated: more magnetizing field then adds little extra flux density.
Soft and hard magnetic materials
| Material group | Magnetic behavior | Useful jobs |
|---|---|---|
| Soft iron, silicon steel and other soft magnetic materials | Easy to magnetize and demagnetize; low coercivity | Relay and contactor cores, electromagnets, transformers and motors |
| Hardened steel, hard ferrite, alnico and neodymium-iron-boron | Resist demagnetization and retain magnetism | Permanent magnets in speakers, motors, sensors and catches |
Here soft describes magnetic behavior. Low coercivity means only a small opposing field is needed to demagnetize the material. It does not mean that all magnetism disappears as soon as current stops. Ferrite materials also come in soft varieties, so a permanent-magnet example is specifically hard ferrite.
Magnetism that remains
Remanence, or residual magnetism, is what remains after the magnetizing field is removed. Its amount depends on the material, its magnetic history and the magnetic circuit. Even soft materials can retain substantial remanence.
A relay armature can stay against its core because of residual attraction. A small non-magnetic gap or stop pin weakens this unwanted holding effect. Residual magnetism also has a useful role: in a self-excited DC generator, it supplies the small initial field from which output builds up.
Coercivity and remanence answer separate design questions. Remanence asks how much magnetism remains when the applied field returns to zero. Coercivity asks how strongly an opposing field must act to remove magnetization. A material can retain a strong field yet need only a small opposing field to demagnetize, so the word “soft” cannot by itself predict the residual pull of an assembled relay.
Remove magnetism or reverse it
Demagnetizing reduces the net alignment of domains. Heating iron above its Curie temperature, about 770 °C, removes its ferromagnetic ordering. Strong shocks and vibration can weaken a magnet. Degaussing uses an alternating magnetic field whose strength is gradually reduced to zero; successive reversals leave little overall alignment.
Repeated reversal also explains hysteresis loss. Some energy is turned into heat each time a core is magnetized in one direction and then the other. Soft magnetic materials need little energy for reversal, making them useful on AC. Hard materials resist reversal and would waste more energy in that job.
Strong neodymium magnets can trap fingers between steel parts and disturb implanted medical devices. Use appropriate non-magnetic handling tools, control nearby steel objects, and keep people with implants away from strong magnets; keep magnetic cards and sensitive equipment clear too.
Key Takeaways
- Domains explain how ferromagnetic materials become magnetized.
- Saturation limits the extra field gained from further magnetizing effort.
- Soft magnetic materials have low coercivity; hard materials suit permanent magnets.
- Soft cores can retain residual magnetism after switch-off.
- Degaussing uses a gradually reduced alternating field.
- Repeated magnetic reversal causes hysteresis heating.
2Fields from electric current
A current-carrying wire makes a magnetic field. Shape that wire into a coil and add a suitable core, and the field becomes useful for movement and control. Direction rules locate the poles; turns, current, magnetic path and air gap explain strength. Solenoids and circuit-breaker trips show how the field does work, while the differences between AC and DC coils explain several common equipment faults.
2.1 Find the field of a wire or coil
Current produces a magnetic field even without an iron core. Winding the wire into a coil brings the fields of many turns together, making a useful pattern with a north end and a south end.
Start with a straight wire
Around a long straight conductor, field lines are concentric circles centered on the wire. Each circle lies in a plane perpendicular to the conductor. The field is strongest near the wire and becomes weaker farther away. Reversing current reverses every field arrow.
Direction rules use conventional current: from the positive terminal through the external circuit to the negative terminal. Electron motion in a metal is opposite. Mixing the two conventions reverses an otherwise correct answer.
For the straight-wire right-hand grip rule, point your right thumb along conventional current. Your curled fingers follow the circular field. The thumb represents the straight quantity, current; the fingers represent the circular quantity, field.
Read an end-on view
A dot shows current coming out of the page, like the approaching tip of an arrow. A cross shows current going into the page, like the feathers of an arrow moving away.
| Current viewed end-on | Field direction |
|---|---|
| Dot: toward you | Counterclockwise |
| Cross: away from you | Clockwise |
Imagine current directed toward you. Point the right thumb toward your face and let your fingers curl. Seen from your position, they turn counterclockwise. Check the viewing direction before applying a remembered clockwise rule: looking from the other end changes the view.
Bring the turns together
A solenoid is wire wound into many turns. Within it, the fields of neighboring turns add to make a strong, nearly uniform field along the coil's axis. Outside, the pattern resembles a bar magnet: lines leave the N end and return to the S end.
For the coil grip rule, curl your right fingers in the direction current travels around the turns. Your thumb points to the coil's N pole. This swaps the roles from the straight-wire rule: the current is now circular, so the fingers follow it.
Seen from the left end of a horizontal coil, suppose current is counterclockwise. Curl the fingers that way. The thumb points left, toward the viewer, so the left end is N. The opposite end is S. The quick end-view check is counterclockwise current → N, clockwise current → S.
Change one feature at a time
Reverse a coil's supply connections and the current reverses, swapping N and S. Reverse the winding direction while keeping the supply connections and current path otherwise equivalent, and the poles swap too. Reverse both and the original polarity returns.
For example, a coil end that was N with counterclockwise current becomes S when the current is reversed to clockwise. Adding a core strengthens the field, but it does not change which hand or current convention identifies the pole. Some electron-flow texts use a left-hand grip rule; keep the conventional-current right-hand rule consistent through a calculation or drawing.
Key Takeaways
- A straight wire produces circular field lines.
- With conventional current, a dot gives a counterclockwise field and a cross a clockwise field.
- For a wire, the right thumb follows current; for a coil, the right fingers follow current.
- Counterclockwise current viewed from a coil end makes that end N.
2.2 Set the strength of an electromagnet
A soft magnetic core inside a coil makes a controllable magnet. Current produces its working field, and reversing current reverses its poles. Residual magnetism may remain when the current stops.
Turns, current and magnetic path
The coil's magnetizing effort is its magnetomotive force, or mmf:
Here N is the number of turns and I is current in amperes. The result is commonly written in ampere-turns (At). A 600-turn coil at 0.25 A gives 150 At. A 1,200-turn coil at 0.125 A also gives 150 At; either turns or current can contribute to the same mmf.
Magnetic field strength is mmf per meter of magnetic path:
Its unit is A/m. The length is the magnetic path, not the total length of copper wire wound onto the core. For the same mmf, a shorter path gives a larger field strength.
How the core responds
Permeability describes how readily a material supports magnetic flux. Relative permeability compares it with free space:
Air, copper, aluminum and plastic have relative permeability close to 1. Iron and steel can have values from hundreds to many thousands. Replacing air with copper will not provide the field increase of a suitable iron core.
For 500 turns, 0.4 A and a 0.1 m magnetic path:
With an air core:
With a core whose relative permeability is 400 at that operating point, the result is about 1.0 T. Relative permeability is not a fixed constant for iron. Near saturation, roughly 1.5–2 T for silicon steel, extra current gives little extra flux and mainly increases heating.
Why an air gap matters
Reluctance is opposition to magnetic flux. Mmf drives flux through a magnetic path much as voltage drives current through resistance. Iron has low reluctance; air has high reluctance. A 1 mm air gap can require more magnetizing effort than the rest of an iron path.
This explains a relay's stronger pull when the armature is close to the core. It also explains why adding turns may not solve a problem caused by a large gap. More current, more turns, higher permeability, a shorter path and a smaller gap all help strengthen an electromagnet, until saturation limits the response.
Include the electrical circuit
On steady DC, coil resistance sets current. A 24 V coil of 96 Ω draws 0.25 A; its 600 turns then produce 150 At. As copper warms, resistance rises. With the same supply voltage, current falls and the field weakens slightly. More turns do not guarantee more mmf at a fixed voltage if the added wire also changes resistance and current.
Key Takeaways
- Mmf is NI in ampere-turns; field strength is NI/l in A/m.
- Permeability connects field strength H with flux density B.
- Saturation limits the gain from extra current.
- Air gaps add high reluctance and weaken pull.
- Steady DC coil current depends on voltage and winding resistance.
2.3 Use electromagnets in equipment
An electromagnet can turn a control signal into movement or release a protective mechanism. Its construction must match both the mechanical job and the kind of supply.
Pull a plunger
A solenoid actuator has a movable soft-iron plunger inside a coil. Energizing the coil draws the plunger inward, shortening the magnetic path and reducing the air gap. A spring returns it when current stops. This produces a short straight stroke for a valve, door strike, lock or fuel injector.
A starter solenoid first engages the starter gear and closes heavy contacts for the starter motor. Lifting magnets use attraction to pick up steel scrap. Electric bells and buzzers use repeated movement. In all these jobs, the largest holding force occurs with a small gap; a solenoid selected only for its seated holding force may fail to pull in from the start of a long stroke.
Trip on a high current
The magnetic trip of a circuit breaker has a coil in series with the protected circuit. Normal current produces too little pull to release the latch. A large short-circuit current produces a much larger pull and trips it rapidly. The thermal bimetal element responds to smaller overloads that persist.
Common IEC miniature-breaker magnetic bands are 3–5 times rated current for type B and 5–10 times for type C. For a 16 A type C device, the band is 80–160 A. Below the lower magnetic threshold, magnetic tripping is not expected; at the upper test threshold it must trip within the specified short test time. “Instantaneous” describes this rapid action, not zero elapsed time. Within the band, the precise magnetic operating point varies. Thermal action still matters below it.
For comparison, the magnetic band of a 16 A type B device is 48–80 A. A 100 A fault is above its upper magnetic threshold but inside the 80–160 A band of the 16 A type C device. The same rated current therefore does not mean the same magnetic response. The curve letter matters as well as the ampere rating; neither band alone specifies the full thermal response to a sustained overload.
Compare DC and AC coils
| Feature | DC electromagnet | AC electromagnet |
|---|---|---|
| Core | Can be solid | Laminated to reduce eddy-current heating |
| Steady operating current | Set by winding resistance | Strongly affected by inductance and the air gap |
| Armature open | No sustained AC-style inrush | High inrush persists until the armature seats |
| Pole-face shading ring | Usually unnecessary | Maintains some pull around main-flux zeros |
An AC armature jammed open leaves a large air gap and low inductance. Its high current then continues and can burn the coil. A DC coil's settled current is set by resistance; movement still produces brief current changes while its magnetic conditions change.
Keep an AC armature seated
AC flux passes through zero twice per cycle: 100 times each second at 50 Hz and 120 times at 60 Hz. A copper shading ring around part of the pole face carries induced current. Its delayed flux maintains some attraction when the main flux passes through zero, reducing hum and chatter.
Coil voltage and AC/DC type must match the supply. An AC coil on equal-voltage DC can overheat because only its low resistance limits settled current. A DC coil on AC may draw too little current to pull in reliably and can chatter. Similar-looking coils with the same printed voltage can have very different electrical behavior.
Key Takeaways
- A solenoid pulls a plunger toward a smaller air gap.
- Pull-in force at a large gap is lower than seated holding force.
- A breaker’s magnetic trip responds rapidly to high fault current; thermal action handles sustained overloads.
- AC cores use laminations to reduce eddy-current loss.
- A jammed-open AC armature can leave damaging inrush current flowing.
- A shading ring maintains some attraction around AC flux zeros.
- Match both the voltage and AC/DC type of a coil.
3Relay and contactor control
Relays and contactors let a small control circuit operate a separate power circuit. Learn how coil current moves contacts, how terminal numbers identify each path, and how a holding contact keeps a machine running after START is released. Following the stop and interlock paths makes circuit behavior easier to predict. Separate coil and contact ratings then guide selection and a sensible sequence of fault checks.
3.1 Trace a relay from coil to load
A small switch or electronic output can control a much larger load through a relay. The coil provides movement; the contacts carry the load current. These are separate electrical jobs with separate ratings.
Follow the movement
A relay has a coil on a soft-iron core, a movable armature, a return spring and contacts. Current in the coil magnetizes the core. The armature moves toward it and changes the contacts. When the coil current stops, the spring returns the mechanism.
The control circuit supplies the coil. The load circuit passes through the contacts. They are electrically separate, so a low-voltage controller can switch a load at another voltage. The contacts do not receive the coil current and amplify it: a separate supply delivers the load's energy.
Read the resting state
Contact names describe the coil de-energized:
| Contact | Coil off | Coil energized |
|---|---|---|
| Normally open, NO | Open | Closed |
| Normally closed, NC | Closed | Open |
| Changeover | Common connected to NC | Common connected to NO |
“Normally open” does not mean open during the machine's usual operating cycle. Circuit diagrams show the de-energized state. Contacts and coils drawn far apart share a device label, such as K1; all K1 contacts operate with that coil.
Separate the two currents
A 12 V relay has a 240 Ω coil and switches a 12 V, 120 W fan. First find the coil current:
The coil uses 0.6 W. Now find the load current independently:
The control switch carries 50 mA. The relay contacts and load wiring carry 10 A. Using the coil current to size the load path would leave that path far too small.
Identify vehicle terminals
Common vehicle markings are 85–86 for the coil, 30 for the common fused feed, 87 for the NO output and 87a for the NC output. A typical circuit connects 85 to chassis ground, 86 to the control switch, 30 to the fused battery feed and 87 to the load. A built-in suppression diode makes coil polarity important, so use the device diagram for the actual connections.
Check operating and contact ratings
A relay needs enough voltage to pull in, but often remains held at a lower voltage. For example, a 12 V device might operate at 9 V or above and release below 1.2 V. Use its specified pull-in and drop-out limits to interpret a sagging supply.
Coil ratings include voltage and AC/DC type. Contact ratings include voltage, current, AC/DC and load type. A 10 A, 250 V AC contact rating cannot establish a safe DC rating. DC lacks the natural current zero that helps extinguish an AC arc. Read the manufacturer's rating at the actual DC voltage and load type.
Key Takeaways
- Coil current creates movement; a separate circuit supplies load current.
- NO and NC describe contacts with the coil de-energized.
- Shared device labels connect coils and contacts across a drawing.
- Vehicle terminals 85–86 are the coil; 30 is common, 87 NO and 87a NC.
- Use the actual voltage and load type when checking contact ratings.
3.2 Start, hold and stop a contactor
A contactor is a heavy-duty relay designed for repeated switching of power loads. Its main poles carry load current, while smaller auxiliary contacts help control its coil and coordinate other devices.
Recognize terminals and duties
A three-pole contactor commonly has coil terminals A1–A2, supply terminals 1, 3, 5 and corresponding load terminals 2, 4, 6. The main paths are therefore 1–2, 3–4 and 5–6. L1/L2/L3 and T1/T2/T3 are alternate supply/load labels.
Auxiliary numbers identify contact functions: 13–14 is NO and 21–22 is NC. In the two-digit convention the final digits 3–4 identify NO, and 1–2 identify NC. These auxiliary contacts carry control duties, not the main motor current.
Arc chutes and double-break contacts help interrupt power current. A contactor plus an overload relay forms a motor starter, often called a magnetic starter. The contactor switches; the overload relay detects sustained excess current and opens the coil circuit.
Build the holding path
A self-holding circuit uses an NC STOP button in series with a parallel pair: the NO START button and the contactor's NO holding contact. That pair then feeds the coil.
- At rest, STOP is closed; START and the holding contact are open.
- Press START. The coil energizes and the contactor closes.
- Its auxiliary contact closes across START.
- Release START. Current continues through STOP and the holding contact.
- Press STOP. The series path opens, the coil drops out and the holding contact opens.
STOP must interrupt both possible coil paths. Putting the holding contact across STOP would bypass the stopping function whenever the contactor was on.
What happens after supply failure?
Loss of supply drops out the coil and opens the holding contact. Once power returns, START is still open and the coil stays off until START is pressed again. This is no-volt protection against an uncommanded restart. A maintained switch directly feeding a coil instead leaves a complete path when power returns, allowing a restart.
Prevent conflicting commands
Forward and reverse contactors must not close together. The NC auxiliary contact of each is placed in series with the other's coil. Energizing one opens the other's control path. A mechanical interlock can add a physical barrier against simultaneous closure.
Match the load category
| Category | Typical duty |
|---|---|
| AC-1 | Resistive or slightly inductive loads, such as heaters |
| AC-3 | Starting squirrel-cage motors and opening the circuit while they run |
A contactor's AC-3 current rating is usually lower than its AC-1 rating because starting motors imposes heavier switching duty. A large AC-1 number alone does not establish motor suitability. North American equipment may instead use NEMA sizes and motor ratings.
Key Takeaways
- A1–A2 is the coil; main poles and auxiliary contacts have separate duties.
- Put the holding NO contact across START and leave NC STOP in series.
- Supply loss opens the holding path, preventing an automatic restart.
- NC cross-interlocks prevent opposing contactors from energizing together.
- AC-1 and AC-3 describe different switching duties.
- A motor starter combines a contactor with overload protection.
3.3 Select a device and follow a fault
A relay can click and still fail to supply its load. Selection and fault finding both become clearer when the coil, mechanism and contacts are treated as separate parts of the device.
Select two ratings
First match the coil to the control supply: voltage and AC/DC type. Then match the contacts to the load voltage, current, AC/DC type and duty, allowing the required margin and starting behavior.
For a 400 V three-phase heater drawing 18 A per phase with 24 V DC control, choose a 24 V DC coil and contacts with adequate AC-1 capacity at 400 V. If the load changes to an 18 A motor, inspect the AC-3 rating at that voltage. The heater rating cannot answer the motor question.
Prepare a safe test
Before resistance or continuity checks, isolate and lock out both control and power circuits, verify absence of voltage, and disconnect at least one coil lead. A dropped-out contactor is not isolation. Keep stored-energy terminals clear during switching; use an approved, guarded test arrangement for any powered functional or voltage-drop check.
Check the winding
Compare coil resistance with the data sheet at a comparable temperature. An OL or infinite reading on the disconnected coil indicates an open winding. A much lower value than specified suggests a winding fault. Copper resistance rises with temperature, so a warm coil can read higher than its room-temperature figure.
Shorted turns can affect magnetic behavior without producing a large, easily measured change in DC resistance. A normal resistance reading therefore leaves other checks to do. It is useful evidence about the winding, not a complete test of coil performance.
Check switching behavior
With the coil off, an NO path should be open and an NC path should conduct. Applying the correct coil supply in a controlled test should reverse those states. A mechanical click only confirms movement; it says little about how well a worn contact carries load current.
For a contact checked at a known current, measure its closed-contact voltage drop and calculate resistance if needed:
At 4 A, a measured 0.08 V corresponds to 0.02 Ω. Whether that is acceptable depends on the manufacturer's test conditions and limits. Low-current continuity checks can miss a contact problem that appears during load operation; specified test load and operating conditions matter.
The 0.08 V drop at 4 A also represents contact heating: W. If deterioration doubled that contact resistance while current stayed at 4 A, the drop would become 0.16 V and heating 0.64 W. A contact can therefore move correctly yet waste increasing power at its conducting surfaces. That is why a functional movement check and an appropriate loaded contact check answer different questions.
Connect symptoms to causes
| Symptom | Causes to investigate |
|---|---|
| No pull-in | Open winding, wrong coil supply, open control path |
| Chatter or loud hum | Low voltage, damaged shading ring, dirt or rust on pole faces |
| Failure to release | Welded contacts, jamming, residual magnetism |
| Burned AC coil | Excess voltage or armature held open |
Use symptoms to choose the next check, not to declare a single cause without evidence. Welded contacts can keep a load connected with the coil off. Solid-state relays remove moving-contact wear and arcing, but have conducting voltage drop and heat, often need a heat sink, and can fail short-circuited. They also do not provide isolation for work.
Key Takeaways
- Match coil supply and contact load ratings independently.
- Compare coil resistance with specified values and temperature conditions.
- OL identifies an open disconnected winding; normal resistance alone leaves other faults possible.
- A click or continuity reading cannot establish full load-switching performance.
- Judge contact voltage drop using known current and manufacturer limits.
- Coil-off and an off command are not safe isolation.
4Force from current and field
Current produces force when a conductor crosses a magnetic field. Calculate its size from field strength, current, length and angle, then use a direction rule to locate the force. Opposite forces can turn a motor coil or move a loudspeaker cone. The same interaction between current and field also acts between parallel conductors, explaining why high fault currents put severe mechanical loads on busbars and their supports.
4.1 Calculate a magnetic force and find its direction
A wire carrying current across a magnetic field experiences a force. This motor effect turns electrical input into mechanical action. Its size and its direction are separate questions.
Calculate the size
For a straight wire perpendicular to a uniform field:
F is force in newtons, B is flux density in teslas, I is current in amperes, and l is the length of wire inside the field in meters. Doubling one factor doubles the force when the others remain unchanged.
A wire carries 12 A through a 0.5 T field, with 0.15 m inside the field:
A total cable length of 2 m would not belong in this calculation if only 0.15 m crosses the field. Convert lengths such as 150 mm to 0.15 m before multiplying.
Include an angle
If the wire makes an angle θ with the field:
The perpendicular part of the current produces the force. At 90°, sine is 1 and force is greatest. At 30°, sine is 0.5, so the same wire experiences 0.45 N. At 0°, the wire lies along the field and force is zero.
The angle is between the conductor's current direction and the field, not between the force and the field. The force itself is perpendicular to both current and field. A negative current direction should be handled by the direction rule while the magnitude calculation uses the current's size.
Use Fleming's left hand
Hold the left thumb, first finger and second finger mutually perpendicular:
- First finger: field, N to S.
- Second finger: conventional current.
- Thumb: force or resulting motion.
Set the field and current fingers first, then read the thumb. Do not choose the thumb direction and twist the other fingers to make it fit. Fleming's right hand is a different rule for a conductor moved to generate voltage.
Work a direction example
Let the field point right across the page and current point into the page. Point the left first finger right and the second finger away from you. The thumb points down, so the force is down the page.
The circular field of this current is clockwise. Above the wire it adds to the rightward external field; below it, it opposes that field. The wire is pushed toward the weaker field below. This field pattern supports the hand-rule result.
Reverse the current alone and force is upward. Reverse the field alone and force is also upward. Reverse both and the two reversals cancel, leaving force downward again. Increasing current without reversing it changes the force's size, not its direction.
Key Takeaways
- For a perpendicular wire, force is BIl and uses only the length inside the field.
- At an angle, multiply by sin θ; a parallel wire has zero force.
- Fleming’s left hand gives motor force from conventional current and N-to-S field.
- Reversing one of current or field reverses force; reversing both leaves its direction unchanged.
4.2 Turn coils, move speakers and brace busbars
The motor effect can produce rotation, straight movement or a load on a support. In each case, current-carrying conductors experience force because they lie across a magnetic field.
Make a coil turn
The two active sides of a rectangular coil carry current in opposite directions. In the same external field, their forces point in opposite directions. Because the forces act on opposite sides of the shaft, they form a turning effect called torque.
Torque is greatest when the plane of the coil lies along the field. It falls to zero when the coil faces directly across the field. Position matters: a strong field and current do not give the same torque at every angle.
A simple DC motor uses a commutator, a split ring touched by brushes, to reverse coil current every half turn. As the sides exchange positions, their currents also reverse. The forces therefore continue to drive rotation in the same sense. Practical machines use many coils and an iron rotor to smooth the turning effect.
More current or a stronger field produces more torque. A heavily loaded or stalled motor can draw a large current, which is why protection must accommodate starting current while still protecting against sustained excess current.
Move a cone or a pointer
A loudspeaker's voice coil sits in the ring-shaped gap of a permanent magnet. Audio current changes direction, so magnetic force on the coil reverses with the signal. The attached cone moves back and forth, pushing air to produce sound. The permanent magnet need not reverse polarity for the cone to reverse motion.
A moving-coil meter also places a coil in a permanent magnetic field. A spring opposes its torque. The pointer settles where the spring balances the magnetic turning effect; deflection is proportional to current through the coil. The spring makes a steady reading possible instead of continuous rotation.
Two wires exert forces on each other
Each parallel conductor creates a field around itself. The other conductor lies in that field, so it experiences a force:
| Parallel current directions | Force |
|---|---|
| Same direction | Attraction |
| Opposite directions | Repulsion |
A pair of loosely suspended wires can move toward or away from each other when large currents flow. The interaction comes from both currents, not from a permanent magnet nearby.
Why fault-current forces are severe
At fixed spacing and geometry, force is proportional to the product of the two currents. When both rise by the same factor, force rises by that factor squared. If a fault takes both currents to 50 times normal:
A support carrying the normal magnetic force may face 2,500 times that force during the fault. Busbars, cable supports and switchgear therefore need mechanical bracing as well as electrical current capacity. If only one conductor's current doubled while the other stayed fixed, force would double; the square relationship applies when both currents scale together.
Key Takeaways
- Opposing forces on a coil produce torque; a commutator maintains rotation in a simple DC motor.
- A speaker’s alternating coil current reverses the force on its cone.
- A moving-coil meter balances magnetic torque against a spring.
- Parallel currents attract when alike in direction and repel when opposite.
- When both parallel currents scale together, their force scales with current squared.
5Voltage from changing flux
Changing magnetic flux can produce voltage in a wire or coil. Learn to separate induced voltage from the current it can drive, calculate the voltage from the rate of change, and identify the opposing effect described by Lenz’s law. Generators, coupled windings, eddy currents and speed sensors apply this shared principle in different ways. Their operation depends on how flux changes, not simply on the presence of a strong magnet.
5.1 Produce and calculate an induced voltage
A magnet held still inside a coil can provide a strong field and produce no voltage. Electromagnetic induction requires a change in the flux linked with the conductor. That change can come from motion or from a changing current nearby.
Voltage first, current if a path exists
An induced emf is an induced voltage. It can exist across an open coil. A closed circuit then allows induced current to flow. Moving a magnet into a coil, moving a wire across a field, or changing current in a neighboring coil can produce emf. Steady linked flux produces none; motion along field lines does not cut them.
Faraday's law gives the magnitude of average emf during a flux change:
N is turns, flux change is in webers, time in seconds and emf in volts. More turns, a larger flux change or a shorter time increases the result. For 200 turns and a 3 mWb change in 0.02 s:
The same change over 0.2 s gives 3 V. The final field can be the same while the voltages differ, because the rate of change differs.
Move a straight conductor
When wire, motion and field are mutually perpendicular:
Use teslas, meters and meters per second. A 0.25 m wire moving at 8 m/s across 0.6 T gives:
For a wire perpendicular to both the motion and the field, but with motion at angle θ to the field lines, multiply by sin θ. At 30° the result is 0.6 V; along the field it is zero. The orientations of both the wire and its motion matter.
Find the opposing effect
Lenz's law says induced current acts to oppose the change producing it. Push a magnet's N pole toward a coil: the near coil end becomes N and repels the approaching pole. Withdraw that pole: the near end becomes S and attracts it, opposing withdrawal. The induced effect opposes change, so it can either reinforce or oppose the existing field depending on what is changing.
This opposition explains why a loaded generator is harder to turn. Mechanical work supplies electrical output; induction does not create energy.
Use Fleming's right hand
Hold the right thumb, first finger and second finger mutually perpendicular. The thumb follows motion, the first finger follows field from N to S, and the second finger gives induced conventional current in a closed circuit.
With field right and motion up the page, the second finger points into the page. Mark that current with a cross. Reversing motion or field reverses induced polarity. Use the right hand when motion produces electrical output; use the left when current produces force.
Key Takeaways
- Changing flux linkage induces emf; a closed path is needed for induced current.
- Faraday’s law uses turns and flux change per second.
- The simple Blv formula requires wire, motion and field to be mutually perpendicular.
- Lenz’s law opposes the change and accounts for the mechanical work of generation.
- Fleming’s right hand gives generator current direction.
5.2 Use induction in generators and sensors
Induction works whenever linked flux changes. Rotating a coil, changing current in a nearby winding, or passing a steel tooth near a sensor can all provide that change.
Generate a repeating voltage
A simple AC generator rotates a coil in a magnetic field, or a magnet within fixed coils. The induced emf reverses every half turn. At constant speed in a uniform field, the simple coil produces a sinusoidal voltage.
The largest emf occurs where flux changes fastest: when the plane of the coil lies along the field and linked flux passes through zero. When the coil faces across the field, flux is greatest but momentarily changes at zero rate, so emf is zero. Maximum flux and maximum emf occur at different positions.
For a generator with one pole pair, one revolution produces one cycle:
At 3,000 r/min the frequency is 50 Hz; at 3,600 r/min it is 60 Hz. The one-pole-pair condition belongs with this simple relationship.
Slip rings take the rotating coil's alternating output to brushes without reversing its connections. A commutator reverses those connections every half turn, giving the external circuit a pulsating direct voltage. The coil's induced emf still alternates.
Reverse the energy flow
A motor converts electrical input into mechanical work. When its shaft is driven mechanically, a suitable machine can generate electrical output. During regenerative braking, a vehicle's wheels drive the machine and energy returns toward the battery. This reverses energy conversion; it does not require the vehicle or shaft to reverse its direction of rotation.
Link two coils
With mutual induction, changing current in one coil changes the flux linking a second coil and induces emf there. A shared iron core improves magnetic coupling. AC repeatedly changes current and supports transformer action. Steady DC in the first coil produces no continuing emf in the second; switching transients can produce brief pulses.
Currents within a metal part
Changing flux can drive loops of eddy current inside solid metal. The currents heat the metal. Thin core laminations, insulated from each other, interrupt large current paths and reduce unwanted heating in AC equipment.
Eddy currents are useful too. They heat suitable cookware on an induction cooktop and produce drag in non-contact brakes. Metal detectors and inductive proximity sensors detect changes in a coil's field caused by nearby metal.
Sense teeth passing a coil
A passive variable-reluctance speed sensor has a coil and permanent magnet facing a toothed steel ring. Each tooth changes the magnetic path and flux, inducing a pulse. More teeth pass per second at higher speed, so pulse frequency rises. The faster flux change also raises signal size. At very low speed the signal becomes weak; newer active sensors can avoid that low-speed limitation.
Key Takeaways
- A generator’s emf depends on flux-change rate, not flux alone.
- One pole pair gives one electrical cycle per revolution.
- Slip rings preserve AC output; a commutator gives pulsating DC externally.
- Mutual induction requires changing flux shared by two coils.
- Laminations reduce unwanted eddy currents; heating and braking can use them.
- A passive toothed-ring sensor produces weaker, slower signals at low speed.
6Self-inductance and switching
A coil responds when its own current changes: its magnetic field stores energy and produces a voltage that opposes the change. Inductance sets that response, while resistance helps set the time scale of a DC circuit. Follow a coil from switch-on to steady current and then to switch-off. The energy released at opening explains both useful ignition pulses and the need for suppression that protects contacts and electronic drivers.
6.1 Follow current as a coil switches on
A changing current changes a coil's own magnetic flux. That changing flux induces voltage in the same winding. Self-induction makes the coil oppose changes in current, delaying its rise and sustaining it during switch-off.
Measure inductance
Inductance L measures flux linkage per ampere:
Its unit is the henry (H). For 400 turns, 2.5 mWb and 5 A:
More turns, a larger core area, higher permeability or a shorter magnetic path increases inductance for otherwise unchanged geometry and material behavior. Turns have a square effect: doubling them gives four times L. An air gap lowers inductance.
Calculate back emf
The magnitude of self-induced emf is:
One henry gives 1 V for a current change of 1 A each second. In a 0.5 H coil, a fall from 2 A to zero in 5 ms gives:
Lenz's law supplies the direction. At switch-on, back emf opposes the rising current. At switch-off, its polarity supports current in the original direction as it falls. It opposes the change, not current at every moment.
Account for stored energy
Energy is stored in the magnetic field:
The 0.5 H coil carrying 2 A stores 1 J. Doubling current would store four times as much energy at unchanged L. When the coil is switched off, that energy must be transferred elsewhere, for example into winding heat or a suppression circuit.
Find the DC time constant
For a fixed inductance and total series resistance:
The time constant is in seconds. After one time constant, switch-on current has reached about 63% of its final value. After five it is practically at its final value. The rising curve becomes less steep as the current approaches its limit.
Take a 12 V supply, 0.2 H coil and 10 Ω resistance. The final current and time constant are:
After 20 ms the current is about 0.76 A. After 100 ms it is nearly 1.2 A. The final current comes from V/R; the time to approach it comes from L/R. Increasing resistance shortens the time constant but also lowers final current at the same voltage.
A lamp in series with a suitable iron-cored coil can light later than an identical lamp with an equal-resistance resistor. Back emf delays current in the coil branch. Once DC current is steady, its flux is steady too: self-induced emf is zero, and winding resistance sets the current. The coil has not lost its inductance; there is simply no current change for it to oppose.
Key Takeaways
- Self-induced emf opposes a change in the coil’s own current.
- Inductance is NΦ/I; induced-emf magnitude is L times the rate of current change.
- Magnetic energy is ½LI² and must be released at switch-off.
- The DC time constant is L/R, while final current is V/R.
- Current reaches about 63% after one time constant and nearly its final value after five.
- Steady DC produces no self-induced emf.
6.2 Control the energy at switch-off
Opening a coil circuit tries to stop current very quickly. The coil's collapsing field induces a voltage that supports the falling current. Without a controlled path for that energy, the voltage can rise enough to arc across contacts or damage electronics.
A small supply can produce a large spike
The relationship is:
A shorter stopping time gives a larger emf for the same current change. A 12 V or 24 V coil can therefore generate hundreds of volts at switch-off. This voltage is not limited to the supply rating: it comes from the rapid release of stored magnetic energy.
A coil can produce a visible spark where a resistor carrying similar current gives little spark. In a protected classroom setup, a neon indicator needing about 70–90 V can flash across a coil supplied by a 1.5 V cell when its circuit opens. Such demonstrations reveal the spike; they are not a reason to touch coil terminals or pull live connectors.
Arcing pits contacts. The spike can also damage insulation, disturb nearby electronics, destroy a transistor or PLC output, and cause shock. Use the proper switch, keep clear of terminals during switching, let energy dissipate, then isolate, lock out and verify absence of voltage before touching the circuit.
For a fixed 0.08 H coil carrying 0.5 A, the initial energy is J. Stopping the current in 0.4 ms gives an average induced magnitude of 100 V; allowing 4 ms gives 10 V. The energy at the start is unchanged. These are two independent suppression requirements: the circuit must tolerate the voltage and provide a destination for the full released energy.
Use the pulse deliberately
A gasoline engine's ignition coil builds current in a primary winding, then interrupts it. Collapsing flux induces emf; a secondary winding with many turns develops the tens of thousands of volts needed at the spark plug. Self-induction in the primary and mutual induction into the secondary work together.
In an older fluorescent fitting, the starter opens and the choke produces a pulse to strike the tube. During operation the choke limits AC current. The pulse is useful only because the surrounding circuit is designed for it.
Give DC current a return path
A flyback diode connects across a DC coil, reverse-biased during normal operation. Its cathode, usually marked by a band, connects to the coil's positive side. It normally blocks current.
At switch-off the coil's polarity reverses and drives current around the coil-diode loop. Energy is dissipated mainly in winding resistance, with some diode loss. A conducting silicon diode holds the reversed coil voltage near its forward drop, typically below about 1 V at suitable current. The current decays over time, so release becomes slower.
Connecting this diode forward across the supply creates a short circuit. Putting one directly across an AC coil makes it conduct during one half-cycle. A plain flyback diode is therefore a DC solution, with polarity essential.
Choose other suppression when needed
An RC snubber places a resistor and capacitor in series to absorb a transient. A varistor or suitable bidirectional transient-suppression diode clamps voltage at a selected level. These can serve AC coils and DC applications needing faster release than a plain diode permits. Use a device or plug-in A1–A2 module rated for the actual coil and driver. A clamp limits voltage; it still has to handle the stored energy and meet the required release time.
Key Takeaways
- An interrupted coil can produce a voltage far above its supply voltage.
- Ignition coils and older lamp chokes use induced pulses deliberately.
- A DC flyback diode is reverse-biased during normal operation, with cathode at coil positive.
- The diode provides a decay path and slows release.
- AC coils need suitable suppression such as an RC snubber or varistor.
Magnetism and Electromagnetic Induction examples
1Read a field and calculate its flux
13 steps
- 1IntroductionStart with the physical change
A magnet can attract steel without touching it. A field drawing shows where this influence points and where it is concentrated. We will read that drawing, calculate flux through a pole face, and choose a material that can change its magnetism easily. Keep two questions separate: how much total flux passes through a face, and how concentrated is that flux?
- 2ExplanationIdentify poles by their forces
Every magnet has N and S poles. Like poles repel; unlike poles attract. Cutting it produces smaller magnets with both poles.
A known magnet attracts ordinary iron too. Repulsion is the useful test that identifies another magnet and a like facing pole.
- 3ExampleAdd arrows to a field pattern
Outside a bar magnet, draw arrows from N to S. Inside it, the lines continue S to N, closing each loop. Lines do not cross, and closer spacing shows greater strength.
A compass supplies the arrows because its north end follows the field. Filings show the curved pattern but no direction. Across a narrow gap between unlike poles, nearly parallel, evenly spaced lines show a nearly uniform field.
- 4ChallengeInterpret an unfamiliar pole
A known S pole repels the left end of a small bar. What pole is that end, and which way would a compass’s north end point just outside it?
---reveal---
The left end is S, because like poles repel. A compass’s N end points toward it along the outside field. Attraction alone would not have identified the bar as a magnet, but repulsion does. Use the same outside N-to-S convention when adding arrows to a diagram.
- 5ExplanationSeparate total flux from concentration
Flux Φ is total magnetic field through an area, in webers. Flux density B is flux per square meter, in teslas. For a uniform field perpendicular to the area:
A wider face carries more flux at unchanged B. A smaller face carrying unchanged flux has greater B. Those are different changes, so decide which quantity is fixed before predicting the result.
- 6ExampleConvert both sides of a pole face
A pole face measures 25 mm by 20 mm. Convert each side to meters before multiplying:
Alternatively, its area is 500 mm² and each mm² is one millionth of a m². This gives the same 0.0005 m². Using the millimeter-to-meter factor only once would be a length conversion applied to an area.
- 7ExampleUse the converted area
Keep that 0.0005 m² face and give it a uniform perpendicular flux density of 0.8 T:
That is 0.4 mWb. Multiplying concentration by area gives a total. As a reverse check, divide 0.0004 Wb by 0.0005 m² and recover 0.8 T. Tilting the face would reduce the flux through it, so the stated orientation is part of the calculation.
- 8ChallengeFind density from a new face
A core carries 0.63 mWb through a 14 cm² cross-section, uniformly and perpendicularly. What flux density does it carry?
---reveal---
Convert to 0.00063 Wb and 0.0014 m², then divide:
The area conversion squares the centimeter-to-meter factor. Dividing flux by area, instead of multiplying them, answers the question about concentration.
- 9AnalogyPicture domains adding together
Think of magnetic domains as many tiny compass-like regions inside a material. If their directions largely cancel, the whole piece has little net magnetism. An applied field lines many up so their contributions add.
This is a model of magnetic alignment, not loose needles moving through the metal. When most domains that can align have done so, the material is saturated and extra effort adds little flux density.
- 10ExplanationChoose a core that can change
Soft magnetic materials have low coercivity: a small opposing field can demagnetize them. This suits relay and AC cores. Hard magnetic materials resist demagnetization and suit permanent magnets.
Soft does not mean zero residual magnetism. Remanence can still hold an armature against its core. A non-magnetic stop gap reduces this unwanted holding effect. Repeated reversal also produces hysteresis heat, reduced by suitable soft material.
- 11ChallengeExplain a release problem
A relay’s supply is removed and coil current has decayed, but residual magnetic attraction holds its armature closed. Why is replacing the core with a hard permanent-magnet material a poor response?
---reveal---
The problem is retained attraction, and a hard magnetic material resists demagnetization. A suitable soft magnetic core is easier to demagnetize; a small non-magnetic gap helps reduce residual holding force. The ability to magnetize strongly is not the only useful selection property for a relay that must release.
- 12ChallengeConnect material and field measurements
Two soft cores carry the same uniform perpendicular flux. Core Q has half the cross-sectional area of P. Which has greater flux density, and why might increasing the magnetizing current eventually give little further increase?
---reveal---
Q has twice the flux density because at unchanged flux. Further current can eventually bring a core near saturation, where extra magnetizing effort adds little B. The area comparison describes concentration; saturation describes how the material responds to additional effort.
- 13RecapKeep the useful distinctions
Use repulsion to identify a magnet and a compass to give field arrows. Keep flux separate from flux density, convert area to m², and preserve the perpendicular-field condition. For changing fields, choose soft magnetic material for easy reversal; allow for remanence and saturation when explaining real magnetic behavior.
2Build a field that can pull a plunger
15 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the physical change
- 2ExplanationUse the wire grip rule
- 3TipSwap the roles for a coil
- 4ChallengeFollow a supply reversal
- 5ExampleCalculate ampere-turns
- 6ExampleFind field strength along a path
- 7ExampleInclude permeability
- 8Key InsightA short air gap can dominate
- 9ChallengeChoose the complete calculation
- 10ConnectionTurn pull into a useful stroke
- 11ExplanationUnderstand AC inrush
- 12ExplanationKeep some pull through AC zeros
- 13ChallengeDiagnose without changing the voltage rating
- 14ChallengeConnect resistance with a weak pull
- 15RecapKeep the useful distinctions
3Trace a start-and-stop control circuit
18 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the physical change
- 2ExplanationSeparate control from power
- 3ExplanationRead contacts with the coil off
- 4ChallengeRead a changeover path
- 5ExampleFind the control current
- 6ExampleCalculate the fan path separately
- 7TipIdentify the contactor paths
- 8ExplanationSet up the holding circuit
- 9ExampleRelease START, then press STOP
- 10ChallengeCheck the location of a bypass
- 11Key InsightA power failure breaks the holding path
- 12ConnectionBlock an opposing contactor
- 13ExampleRead both sets of ratings
- 14TipCheck a winding as one part of diagnosis
- 15ChallengeUse a specified contact test
- 16Key InsightDo not turn an off command into isolation
- 17ChallengeCombine a rating with a circuit state
- 18RecapKeep the useful distinctions
4Predict force, rotation and busbar stress
12 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the physical change
- 2ExplanationSeparate size and direction
- 3ExampleWork the perpendicular case
- 4ExampleTurn the wire toward the field
- 5TipSet the left hand in order
- 6ChallengeChoose the active length and direction
- 7ExplanationArrange forces to turn a coil
- 8ConnectionLet a signal move a cone or pointer
- 9ExplanationLet each conductor supply the other’s field
- 10ChallengeScale two unequal current changes
- 11ChallengeCombine an angle with a current change
- 12RecapKeep the useful distinctions
5Make voltage from changing flux
14 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the physical change
- 2ExplanationFind what changes the linked flux
- 3ExampleCalculate the flux change per second
- 4ExampleMultiply the rate by turns
- 5Key InsightOppose approach and withdrawal differently
- 6ChallengeInfer a new rate and magnetic response
- 7ExampleMove a wire and find its current direction
- 8ExplanationTurn a coil through a field
- 9ExampleMatch rotation and output connections
- 10ConnectionChange which way energy moves
- 11ExplanationLink a second winding or a metal loop
- 12ChallengeExplain a passive speed signal
- 13ChallengeConnect generation with the load
- 14RecapKeep the useful distinctions
6Switch a coil without losing track of its energy
14 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the physical change
- 2ExplanationOppose a change, not every current
- 3ExampleCalculate inductance from linkage
- 4ExampleFind final current separately from delay
- 5ExampleRead one and five time constants
- 6ChallengeFind current after 20 ms
- 7ExamplePut a number on stored energy
- 8ExampleMake the stopping time visible
- 9ConnectionUse a pulse when the circuit needs one
- 10ExplanationLet a diode carry the decay current
- 11ChallengeSpot a polarity error
- 12TipChoose a clamp for the job
- 13ChallengeConnect stored energy with the clamp
- 14RecapKeep the useful distinctions
Magnetism and Electromagnetic Induction practice questions
Set 1: Electromagnet strength and actuator behavior10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Fields, flux and magnetic materials10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Relay contacts, holding circuits and fault checks10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Motor force and fault-current loads10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 5: Generators, changing flux and sensors10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 6: Self-inductance, stored energy and suppression10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
A
Active conductor length
Air gap
Alternator
Armature
Auxiliary contact
B
Back emf
Busbar
C
Changeover contact
Choke
Coercivity
Coil rating
Commutator
Contact rating
Contact resistance
Contactor
Conventional current
D
Degaussing
Drop-out voltage
E
Eddy current
Electromagnet
Electromagnetic induction
End-on current symbol
F
Faraday’s law
Fault-current force
Ferromagnetic material
Field line
Fleming’s left-hand rule
Fleming’s right-hand rule
Flux density
Flux linkage
Flyback diode
H
Henry
Hysteresis loss
I
Ignition coil
Inductance
Inductive proximity sensor
Inductive voltage spike
Inrush current
Interlock
L
Laminated core
Lenz’s law
M
Magnetic domain
Magnetic field
Magnetic field strength
Magnetic flux
Magnetic pole
Magnetic screening
Magnetic trip
Magnetomotive force
Motor effect
Motor starter
Moving-coil meter
Mutual induction
N
Neutral point
No-volt protection
Normally closed contact
Normally open contact
P
Perpendicular component
Pull-in voltage
R
RC snubber
Regenerative braking
Relative permeability
Relay
Reluctance
Remanence
Right-hand grip rule
S
Saturation
Self-holding circuit
Self-induction
Shading ring
Slip ring
Solenoid
Solenoid actuator
Solid-state relay
Stored magnetic energy
T
Tesla
Time constant
Torque
U
Uniform magnetic field
Utilization category
V
Variable-reluctance sensor
Varistor
Voice coil
W
Weber
- 1Ohm’s Law
- 2Series and Parallel Circuits
- 3Magnetism and Electromagnetic Induction
- 4Alternating Current
- 5Transformers and Motors
- 6Electrical Safety at Work
- 7Electrical Measuring and Test Instruments