Magnetism and Electromagnetic Induction

Learn how magnets and electric currents produce magnetic fields, and how those fields are put to work in electrical equipment. Describe fields with poles, field lines, flux and flux density, and explain what makes an electromagnet strong. Follow how relays and contactors switch circuits, calculate the force on a current-carrying conductor, and explain how a changing field induces a voltage in generators, coils and sensors. Finish with self-inductance: why coils resist changes in current, and how to switch relay coils, solenoids and other inductive loads without damaging contacts and electronics.

BeginnerLesson 3 of 7 in Electrical Principles for Technicians Course

What you will learn

  1. Describe the field around a magnet with poles and field lines, measure it as flux and flux density, and explain how materials are magnetized, keep their magnetism and lose it.
    • Describe magnets, poles and field lines
      Use poles, attraction and repulsion, and field-line diagrams to describe the magnetic field around permanent magnets.
    • Calculate magnetic flux and flux density
      Use magnetic flux in webers and flux density in teslas, and calculate one from the other with Φ = B × A.
    • Explain magnetizing, demagnetizing and remanent magnetism
      Explain why some materials are easily magnetized, choose soft or hard magnetic materials for a job, and describe remanence, saturation and how magnetism is removed.
  2. Find the field around a straight conductor and a coil, and explain what sets the strength of an electromagnet and how solenoids and electromagnets are used in equipment.
    • Find the field around a conductor and a coil
      Draw the circular field around a straight conductor and the bar-magnet field of a coil, and find directions and poles with the right-hand grip rule.
    • Explain what makes an electromagnet strong
      Use ampere-turns, magnetic field strength and permeability to explain and calculate how current, turns, core material and air gaps affect an electromagnet.
    • Explain how solenoids and electromagnets work in equipment
      Explain the action of solenoid actuators, lifting magnets and magnetic trips, and the differences between DC and AC electromagnets.
  3. Describe the parts and contacts of relays and contactors, read their terminal markings, follow simple control circuits and check that a relay or contactor suits its job.
    • Explain how a relay works
      Describe a relay's coil, armature and contacts, and explain how a small control current switches a separate, larger load current.
    • Explain contactors and self-holding control circuits
      Distinguish contactors from relays, read contactor terminal markings, and explain how start and stop buttons with a holding contact control a load safely.
    • Choose and check relays and contactors
      Match a relay or contactor to its supply and load, recognize the signs of common faults, and test coils and contacts safely.
  4. Calculate the force on a conductor in a magnetic field, find its direction, and explain how the motor effect drives motors, loudspeakers and meters and stresses busbars.
    • Calculate the size and direction of the force
      Use F = B × I × l to calculate the force on a conductor and Fleming's left-hand rule to find its direction.
    • Explain the motor effect in machines, speakers and busbars
      Explain how the motor effect turns a coil, drives loudspeakers and moving-coil meters, and produces large forces between conductors carrying fault currents.
  5. Explain how a changing magnetic field induces a voltage, calculate induced voltages, find their direction, and apply induction to generators, coupled coils, eddy currents and sensors.
    • Explain and calculate induced voltage
      Use Faraday's and Lenz's laws and Fleming's right-hand rule to predict when a voltage is induced, how large it is and which way the current flows.
    • Apply induction in generators, coupled coils, eddy currents and sensors
      Explain how a simple generator produces an alternating voltage and how mutual induction, eddy currents and induction sensors work in equipment.
  6. Explain how a coil opposes changes in its own current, calculate inductance, induced voltage, stored energy and time constant, and protect contacts and electronics when inductive loads are switched off.
    • Explain and calculate self-inductance
      Define inductance and the henry, explain the back emf of a coil, and calculate induced voltage, stored energy and the time constant of an inductive DC circuit.
    • Control voltage spikes when switching inductive loads
      Explain why breaking an inductive circuit causes a voltage spike and arcing, how ignition coils and lamp chokes use it, and how diodes, RC snubbers and varistors suppress it.

Magnetism and Electromagnetic Induction study guide

6 chapters

1

Magnetic fields and materials

An invisible field explains why a magnet pulls steel, why a compass turns and why pole faces concentrate magnetic effects. Learn to read that field with poles and field lines, then distinguish total flux from flux density through a measured area. The behavior of magnetic materials completes the picture: some serve as permanent magnets, while others make cores whose magnetism can be changed easily by a coil.

1.1 Read a magnetic field

A magnet can pull an unmagnetized steel part toward either end. Bring two magnets together and a second behavior appears: they can push apart. These forces help identify poles and make sense of a field drawing.

Poles and magnetic materials

Every magnet has a north pole (N) and a south pole (S). Like poles repel; unlike poles attract. The magnetic effect is strongest near the poles. Cutting a bar magnet makes two smaller magnets, each with its own N and S. It does not separate north from south.

Attraction alone cannot identify a magnet: an ordinary piece of iron is attracted by either pole. Repulsion gives the useful test. If a known magnet repels an object, that object is also a magnet, presenting the same kind of pole.

Iron, ordinary steel, nickel and cobalt are strongly attracted. Copper, aluminum, brass and common austenitic stainless steels such as grade 304 are only weakly affected in this test. A metal object need not be strongly magnetic just because it conducts electricity.

What the lines show

A magnetic field is the region in which magnetic forces act. Field lines are a drawing model, not threads in space. Their arrows show where the north end of a small compass points; their spacing shows relative strength.

  • Outside a magnet, lines run from N to S.
  • Inside it, they continue from S to N, making closed loops.
  • Lines never cross: the field has one direction at each point.
  • Closer lines show a stronger field.

Around a bar magnet, lines curve from one pole to the other. Across a narrow gap between unlike poles, they can be nearly straight, parallel and evenly spaced: a nearly uniform field. Between facing like poles, the patterns bend away from each other. With identical magnets placed symmetrically, their equal opposing fields cancel at the midpoint, creating a neutral point.

Use a compass to add direction

To plot a field, place a compass at a point, mark the needle's N-end direction, then move it a short distance along that direction. Repeat and join the marks smoothly. Start again from other positions to build the pattern. Iron filings reveal a pattern too, but their shapes alone do not supply arrows.

For example, a compass to the right of a bar magnet's S pole points left, toward that pole. This follows the outside N-to-S direction. The compass's north end is attracted to the magnet's south end.

Earth's surface field is roughly 25–65 µT. The magnetic pole near geographic north behaves as a magnetic south pole, which attracts the compass's N end. Geographic and magnetic pole names describe different things.

Guide a field around equipment

Air, wood, plastic and copper allow a steady magnetic field through with little change. A soft-iron or special-alloy screen gives flux an easier path around a protected space. A plastic cover can prevent contact with a magnet, but it does not provide the magnetic screening of a suitable iron enclosure.

Key Takeaways

  • Like poles repel and unlike poles attract; repulsion identifies a magnet.
  • Field lines form closed loops and run N to S outside a magnet.
  • Line spacing shows relative field strength; arrows show compass direction.
  • Equal opposing fields cancel at a neutral point.
  • Magnetic screening redirects flux through a suitable magnetic material.

1.2 Flux, flux density and area

A wide magnetic pole face may carry more total field than a narrow one without having a more concentrated field. Flux and flux density describe these two different quantities.

Total field and concentration

Magnetic flux, Φ, is the total magnetic field passing through an area. Its SI unit is the weber (Wb). A milliweber is not a separate kind of field: 1 mWb is 0.001 Wb. A microweber is 0.000001 Wb.

Flux density, B, is the flux per square meter measured across the field. Its unit is the tesla (T); 1 T equals 1 Wb/m². A high flux density means the field is concentrated. Two cores can carry the same flux but have different flux densities if their cross-sectional areas differ.

For a uniform field perpendicular to an area:

Φ=B×A,B=ΦA,A=ΦB

Use teslas, webers and square meters in these forms. Increasing area at fixed flux density increases total flux. Increasing area at fixed total flux reduces flux density. Identify which quantity stays fixed before predicting a change.

Convert the area first

Area conversions are squared length conversions:

1 cm2=10−4 m2,1 mm2=10−6 m2

A pole face 25 mm by 20 mm can be converted two ways. Convert the sides to 0.025 m and 0.020 m and multiply, or calculate 500 mm² and multiply by one millionth. Both give:

A=0.025×0.020=0.0005 m2

At 0.8 T, the flux is:

Φ=0.8×0.0005=0.0004 Wb=0.4 mWb

Using 0.001 as the conversion factor for mm² would make the area 1,000 times too large. That factor converts millimeters to meters, not square millimeters to square meters.

Work backward from flux

A core carries 1.2 mWb through 15 cm². Convert both quantities before dividing:

Φ=0.0012 Wb,A=15×10−4=0.0015 m2 B=0.00120.0015=0.8 T

A quick unit check helps: webers divided by square meters must give teslas. Dividing area by flux reverses that relationship and gives the wrong unit.

Orientation and scale

The simple product uses the area facing directly across the field. Tilt the face and less flux passes through it. Turn it until its plane lies along the lines and no flux passes through that face, even though a field is still present.

Earth's field is about 50 µT, or 0.00005 T. A fridge magnet has a few millitesla at its surface; a motor or relay air gap may have roughly 0.5–1 T. Common hospital MRI scanners use 1.5–3 T. These values show why the unit prefix matters: 50 µT is a very different field from 50 mT.

Key Takeaways

  • Flux is total field through an area; flux density is flux per square meter.
  • Use Φ = BA for a uniform field perpendicular to the area.
  • Convert both area dimensions, or square the length conversion factor.
  • Tilting an area changes the flux through it.

1.3 Choose and change magnetic materials

The same magnetic field can leave one material strongly magnetized and another easy to demagnetize. This difference matters when choosing a permanent magnet or a core that must respond to a changing current.

A domain model

Ferromagnetic materials include iron, nickel, cobalt and many of their alloys. They contain tiny magnetic regions called domains. In an unmagnetized piece their effects largely cancel. An applied field lines many domains up, so their contributions add.

Stroking a suitable material with a magnet, placing it inside an energized coil or exposing it to a strong field can magnetize it. Eventually the domains that can align have done so. The material is saturated: more magnetizing field then adds little extra flux density.

Soft and hard magnetic materials
Material groupMagnetic behaviorUseful jobs
Soft iron, silicon steel and other soft magnetic materialsEasy to magnetize and demagnetize; low coercivityRelay and contactor cores, electromagnets, transformers and motors
Hardened steel, hard ferrite, alnico and neodymium-iron-boronResist demagnetization and retain magnetismPermanent magnets in speakers, motors, sensors and catches

Here soft describes magnetic behavior. Low coercivity means only a small opposing field is needed to demagnetize the material. It does not mean that all magnetism disappears as soon as current stops. Ferrite materials also come in soft varieties, so a permanent-magnet example is specifically hard ferrite.

Magnetism that remains

Remanence, or residual magnetism, is what remains after the magnetizing field is removed. Its amount depends on the material, its magnetic history and the magnetic circuit. Even soft materials can retain substantial remanence.

A relay armature can stay against its core because of residual attraction. A small non-magnetic gap or stop pin weakens this unwanted holding effect. Residual magnetism also has a useful role: in a self-excited DC generator, it supplies the small initial field from which output builds up.

Coercivity and remanence answer separate design questions. Remanence asks how much magnetism remains when the applied field returns to zero. Coercivity asks how strongly an opposing field must act to remove magnetization. A material can retain a strong field yet need only a small opposing field to demagnetize, so the word “soft” cannot by itself predict the residual pull of an assembled relay.

Remove magnetism or reverse it

Demagnetizing reduces the net alignment of domains. Heating iron above its Curie temperature, about 770 °C, removes its ferromagnetic ordering. Strong shocks and vibration can weaken a magnet. Degaussing uses an alternating magnetic field whose strength is gradually reduced to zero; successive reversals leave little overall alignment.

Repeated reversal also explains hysteresis loss. Some energy is turned into heat each time a core is magnetized in one direction and then the other. Soft magnetic materials need little energy for reversal, making them useful on AC. Hard materials resist reversal and would waste more energy in that job.

Strong neodymium magnets can trap fingers between steel parts and disturb implanted medical devices. Use appropriate non-magnetic handling tools, control nearby steel objects, and keep people with implants away from strong magnets; keep magnetic cards and sensitive equipment clear too.

Key Takeaways

  • Domains explain how ferromagnetic materials become magnetized.
  • Saturation limits the extra field gained from further magnetizing effort.
  • Soft magnetic materials have low coercivity; hard materials suit permanent magnets.
  • Soft cores can retain residual magnetism after switch-off.
  • Degaussing uses a gradually reduced alternating field.
  • Repeated magnetic reversal causes hysteresis heating.
2

Fields from electric current

A current-carrying wire makes a magnetic field. Shape that wire into a coil and add a suitable core, and the field becomes useful for movement and control. Direction rules locate the poles; turns, current, magnetic path and air gap explain strength. Solenoids and circuit-breaker trips show how the field does work, while the differences between AC and DC coils explain several common equipment faults.

2.1 Find the field of a wire or coil

Current produces a magnetic field even without an iron core. Winding the wire into a coil brings the fields of many turns together, making a useful pattern with a north end and a south end.

Start with a straight wire

Around a long straight conductor, field lines are concentric circles centered on the wire. Each circle lies in a plane perpendicular to the conductor. The field is strongest near the wire and becomes weaker farther away. Reversing current reverses every field arrow.

Direction rules use conventional current: from the positive terminal through the external circuit to the negative terminal. Electron motion in a metal is opposite. Mixing the two conventions reverses an otherwise correct answer.

For the straight-wire right-hand grip rule, point your right thumb along conventional current. Your curled fingers follow the circular field. The thumb represents the straight quantity, current; the fingers represent the circular quantity, field.

Read an end-on view

A dot shows current coming out of the page, like the approaching tip of an arrow. A cross shows current going into the page, like the feathers of an arrow moving away.

Current viewed end-onField direction
Dot: toward youCounterclockwise
Cross: away from youClockwise

Imagine current directed toward you. Point the right thumb toward your face and let your fingers curl. Seen from your position, they turn counterclockwise. Check the viewing direction before applying a remembered clockwise rule: looking from the other end changes the view.

Bring the turns together

A solenoid is wire wound into many turns. Within it, the fields of neighboring turns add to make a strong, nearly uniform field along the coil's axis. Outside, the pattern resembles a bar magnet: lines leave the N end and return to the S end.

For the coil grip rule, curl your right fingers in the direction current travels around the turns. Your thumb points to the coil's N pole. This swaps the roles from the straight-wire rule: the current is now circular, so the fingers follow it.

Seen from the left end of a horizontal coil, suppose current is counterclockwise. Curl the fingers that way. The thumb points left, toward the viewer, so the left end is N. The opposite end is S. The quick end-view check is counterclockwise current → N, clockwise current → S.

Change one feature at a time

Reverse a coil's supply connections and the current reverses, swapping N and S. Reverse the winding direction while keeping the supply connections and current path otherwise equivalent, and the poles swap too. Reverse both and the original polarity returns.

For example, a coil end that was N with counterclockwise current becomes S when the current is reversed to clockwise. Adding a core strengthens the field, but it does not change which hand or current convention identifies the pole. Some electron-flow texts use a left-hand grip rule; keep the conventional-current right-hand rule consistent through a calculation or drawing.

Key Takeaways

  • A straight wire produces circular field lines.
  • With conventional current, a dot gives a counterclockwise field and a cross a clockwise field.
  • For a wire, the right thumb follows current; for a coil, the right fingers follow current.
  • Counterclockwise current viewed from a coil end makes that end N.

2.2 Set the strength of an electromagnet

A soft magnetic core inside a coil makes a controllable magnet. Current produces its working field, and reversing current reverses its poles. Residual magnetism may remain when the current stops.

Turns, current and magnetic path

The coil's magnetizing effort is its magnetomotive force, or mmf:

Fm=N×I

Here N is the number of turns and I is current in amperes. The result is commonly written in ampere-turns (At). A 600-turn coil at 0.25 A gives 150 At. A 1,200-turn coil at 0.125 A also gives 150 At; either turns or current can contribute to the same mmf.

Magnetic field strength is mmf per meter of magnetic path:

H=NIl

Its unit is A/m. The length is the magnetic path, not the total length of copper wire wound onto the core. For the same mmf, a shorter path gives a larger field strength.

How the core responds

Permeability describes how readily a material supports magnetic flux. Relative permeability compares it with free space:

B=μ0μrH,μ0≈1.257×10−6 H/m

Air, copper, aluminum and plastic have relative permeability close to 1. Iron and steel can have values from hundreds to many thousands. Replacing air with copper will not provide the field increase of a suitable iron core.

For 500 turns, 0.4 A and a 0.1 m magnetic path:

Fm=500×0.4=200 At,H=200/0.1=2000 A/m

With an air core:

B=4π×10−7×2000≈0.0025 T

With a core whose relative permeability is 400 at that operating point, the result is about 1.0 T. Relative permeability is not a fixed constant for iron. Near saturation, roughly 1.5–2 T for silicon steel, extra current gives little extra flux and mainly increases heating.

Why an air gap matters

Reluctance is opposition to magnetic flux. Mmf drives flux through a magnetic path much as voltage drives current through resistance. Iron has low reluctance; air has high reluctance. A 1 mm air gap can require more magnetizing effort than the rest of an iron path.

This explains a relay's stronger pull when the armature is close to the core. It also explains why adding turns may not solve a problem caused by a large gap. More current, more turns, higher permeability, a shorter path and a smaller gap all help strengthen an electromagnet, until saturation limits the response.

Include the electrical circuit

On steady DC, coil resistance sets current. A 24 V coil of 96 Ω draws 0.25 A; its 600 turns then produce 150 At. As copper warms, resistance rises. With the same supply voltage, current falls and the field weakens slightly. More turns do not guarantee more mmf at a fixed voltage if the added wire also changes resistance and current.

Key Takeaways

  • Mmf is NI in ampere-turns; field strength is NI/l in A/m.
  • Permeability connects field strength H with flux density B.
  • Saturation limits the gain from extra current.
  • Air gaps add high reluctance and weaken pull.
  • Steady DC coil current depends on voltage and winding resistance.

2.3 Use electromagnets in equipment

An electromagnet can turn a control signal into movement or release a protective mechanism. Its construction must match both the mechanical job and the kind of supply.

Pull a plunger

A solenoid actuator has a movable soft-iron plunger inside a coil. Energizing the coil draws the plunger inward, shortening the magnetic path and reducing the air gap. A spring returns it when current stops. This produces a short straight stroke for a valve, door strike, lock or fuel injector.

A starter solenoid first engages the starter gear and closes heavy contacts for the starter motor. Lifting magnets use attraction to pick up steel scrap. Electric bells and buzzers use repeated movement. In all these jobs, the largest holding force occurs with a small gap; a solenoid selected only for its seated holding force may fail to pull in from the start of a long stroke.

Trip on a high current

The magnetic trip of a circuit breaker has a coil in series with the protected circuit. Normal current produces too little pull to release the latch. A large short-circuit current produces a much larger pull and trips it rapidly. The thermal bimetal element responds to smaller overloads that persist.

Common IEC miniature-breaker magnetic bands are 3–5 times rated current for type B and 5–10 times for type C. For a 16 A type C device, the band is 80–160 A. Below the lower magnetic threshold, magnetic tripping is not expected; at the upper test threshold it must trip within the specified short test time. “Instantaneous” describes this rapid action, not zero elapsed time. Within the band, the precise magnetic operating point varies. Thermal action still matters below it.

For comparison, the magnetic band of a 16 A type B device is 48–80 A. A 100 A fault is above its upper magnetic threshold but inside the 80–160 A band of the 16 A type C device. The same rated current therefore does not mean the same magnetic response. The curve letter matters as well as the ampere rating; neither band alone specifies the full thermal response to a sustained overload.

Compare DC and AC coils
FeatureDC electromagnetAC electromagnet
CoreCan be solidLaminated to reduce eddy-current heating
Steady operating currentSet by winding resistanceStrongly affected by inductance and the air gap
Armature openNo sustained AC-style inrushHigh inrush persists until the armature seats
Pole-face shading ringUsually unnecessaryMaintains some pull around main-flux zeros

An AC armature jammed open leaves a large air gap and low inductance. Its high current then continues and can burn the coil. A DC coil's settled current is set by resistance; movement still produces brief current changes while its magnetic conditions change.

Keep an AC armature seated

AC flux passes through zero twice per cycle: 100 times each second at 50 Hz and 120 times at 60 Hz. A copper shading ring around part of the pole face carries induced current. Its delayed flux maintains some attraction when the main flux passes through zero, reducing hum and chatter.

Coil voltage and AC/DC type must match the supply. An AC coil on equal-voltage DC can overheat because only its low resistance limits settled current. A DC coil on AC may draw too little current to pull in reliably and can chatter. Similar-looking coils with the same printed voltage can have very different electrical behavior.

Key Takeaways

  • A solenoid pulls a plunger toward a smaller air gap.
  • Pull-in force at a large gap is lower than seated holding force.
  • A breaker’s magnetic trip responds rapidly to high fault current; thermal action handles sustained overloads.
  • AC cores use laminations to reduce eddy-current loss.
  • A jammed-open AC armature can leave damaging inrush current flowing.
  • A shading ring maintains some attraction around AC flux zeros.
  • Match both the voltage and AC/DC type of a coil.
3

Relay and contactor control

Relays and contactors let a small control circuit operate a separate power circuit. Learn how coil current moves contacts, how terminal numbers identify each path, and how a holding contact keeps a machine running after START is released. Following the stop and interlock paths makes circuit behavior easier to predict. Separate coil and contact ratings then guide selection and a sensible sequence of fault checks.

3.1 Trace a relay from coil to load

A small switch or electronic output can control a much larger load through a relay. The coil provides movement; the contacts carry the load current. These are separate electrical jobs with separate ratings.

Follow the movement

A relay has a coil on a soft-iron core, a movable armature, a return spring and contacts. Current in the coil magnetizes the core. The armature moves toward it and changes the contacts. When the coil current stops, the spring returns the mechanism.

The control circuit supplies the coil. The load circuit passes through the contacts. They are electrically separate, so a low-voltage controller can switch a load at another voltage. The contacts do not receive the coil current and amplify it: a separate supply delivers the load's energy.

Read the resting state

Contact names describe the coil de-energized:

ContactCoil offCoil energized
Normally open, NOOpenClosed
Normally closed, NCClosedOpen
ChangeoverCommon connected to NCCommon connected to NO

“Normally open” does not mean open during the machine's usual operating cycle. Circuit diagrams show the de-energized state. Contacts and coils drawn far apart share a device label, such as K1; all K1 contacts operate with that coil.

Separate the two currents

A 12 V relay has a 240 Ω coil and switches a 12 V, 120 W fan. First find the coil current:

Icoil=12/240=0.05 A=50 mA

The coil uses 0.6 W. Now find the load current independently:

Iload=120/12=10 A

The control switch carries 50 mA. The relay contacts and load wiring carry 10 A. Using the coil current to size the load path would leave that path far too small.

Identify vehicle terminals

Common vehicle markings are 85–86 for the coil, 30 for the common fused feed, 87 for the NO output and 87a for the NC output. A typical circuit connects 85 to chassis ground, 86 to the control switch, 30 to the fused battery feed and 87 to the load. A built-in suppression diode makes coil polarity important, so use the device diagram for the actual connections.

Check operating and contact ratings

A relay needs enough voltage to pull in, but often remains held at a lower voltage. For example, a 12 V device might operate at 9 V or above and release below 1.2 V. Use its specified pull-in and drop-out limits to interpret a sagging supply.

Coil ratings include voltage and AC/DC type. Contact ratings include voltage, current, AC/DC and load type. A 10 A, 250 V AC contact rating cannot establish a safe DC rating. DC lacks the natural current zero that helps extinguish an AC arc. Read the manufacturer's rating at the actual DC voltage and load type.

Key Takeaways

  • Coil current creates movement; a separate circuit supplies load current.
  • NO and NC describe contacts with the coil de-energized.
  • Shared device labels connect coils and contacts across a drawing.
  • Vehicle terminals 85–86 are the coil; 30 is common, 87 NO and 87a NC.
  • Use the actual voltage and load type when checking contact ratings.

3.2 Start, hold and stop a contactor

A contactor is a heavy-duty relay designed for repeated switching of power loads. Its main poles carry load current, while smaller auxiliary contacts help control its coil and coordinate other devices.

Recognize terminals and duties

A three-pole contactor commonly has coil terminals A1–A2, supply terminals 1, 3, 5 and corresponding load terminals 2, 4, 6. The main paths are therefore 1–2, 3–4 and 5–6. L1/L2/L3 and T1/T2/T3 are alternate supply/load labels.

Auxiliary numbers identify contact functions: 13–14 is NO and 21–22 is NC. In the two-digit convention the final digits 3–4 identify NO, and 1–2 identify NC. These auxiliary contacts carry control duties, not the main motor current.

Arc chutes and double-break contacts help interrupt power current. A contactor plus an overload relay forms a motor starter, often called a magnetic starter. The contactor switches; the overload relay detects sustained excess current and opens the coil circuit.

Build the holding path

A self-holding circuit uses an NC STOP button in series with a parallel pair: the NO START button and the contactor's NO holding contact. That pair then feeds the coil.

  1. At rest, STOP is closed; START and the holding contact are open.
  2. Press START. The coil energizes and the contactor closes.
  3. Its auxiliary contact closes across START.
  4. Release START. Current continues through STOP and the holding contact.
  5. Press STOP. The series path opens, the coil drops out and the holding contact opens.

STOP must interrupt both possible coil paths. Putting the holding contact across STOP would bypass the stopping function whenever the contactor was on.

What happens after supply failure?

Loss of supply drops out the coil and opens the holding contact. Once power returns, START is still open and the coil stays off until START is pressed again. This is no-volt protection against an uncommanded restart. A maintained switch directly feeding a coil instead leaves a complete path when power returns, allowing a restart.

Prevent conflicting commands

Forward and reverse contactors must not close together. The NC auxiliary contact of each is placed in series with the other's coil. Energizing one opens the other's control path. A mechanical interlock can add a physical barrier against simultaneous closure.

Match the load category
CategoryTypical duty
AC-1Resistive or slightly inductive loads, such as heaters
AC-3Starting squirrel-cage motors and opening the circuit while they run

A contactor's AC-3 current rating is usually lower than its AC-1 rating because starting motors imposes heavier switching duty. A large AC-1 number alone does not establish motor suitability. North American equipment may instead use NEMA sizes and motor ratings.

Key Takeaways

  • A1–A2 is the coil; main poles and auxiliary contacts have separate duties.
  • Put the holding NO contact across START and leave NC STOP in series.
  • Supply loss opens the holding path, preventing an automatic restart.
  • NC cross-interlocks prevent opposing contactors from energizing together.
  • AC-1 and AC-3 describe different switching duties.
  • A motor starter combines a contactor with overload protection.

3.3 Select a device and follow a fault

A relay can click and still fail to supply its load. Selection and fault finding both become clearer when the coil, mechanism and contacts are treated as separate parts of the device.

Select two ratings

First match the coil to the control supply: voltage and AC/DC type. Then match the contacts to the load voltage, current, AC/DC type and duty, allowing the required margin and starting behavior.

For a 400 V three-phase heater drawing 18 A per phase with 24 V DC control, choose a 24 V DC coil and contacts with adequate AC-1 capacity at 400 V. If the load changes to an 18 A motor, inspect the AC-3 rating at that voltage. The heater rating cannot answer the motor question.

Prepare a safe test

Before resistance or continuity checks, isolate and lock out both control and power circuits, verify absence of voltage, and disconnect at least one coil lead. A dropped-out contactor is not isolation. Keep stored-energy terminals clear during switching; use an approved, guarded test arrangement for any powered functional or voltage-drop check.

Check the winding

Compare coil resistance with the data sheet at a comparable temperature. An OL or infinite reading on the disconnected coil indicates an open winding. A much lower value than specified suggests a winding fault. Copper resistance rises with temperature, so a warm coil can read higher than its room-temperature figure.

Shorted turns can affect magnetic behavior without producing a large, easily measured change in DC resistance. A normal resistance reading therefore leaves other checks to do. It is useful evidence about the winding, not a complete test of coil performance.

Check switching behavior

With the coil off, an NO path should be open and an NC path should conduct. Applying the correct coil supply in a controlled test should reverse those states. A mechanical click only confirms movement; it says little about how well a worn contact carries load current.

For a contact checked at a known current, measure its closed-contact voltage drop and calculate resistance if needed:

Rcontact=Vdrop/I

At 4 A, a measured 0.08 V corresponds to 0.02 Ω. Whether that is acceptable depends on the manufacturer's test conditions and limits. Low-current continuity checks can miss a contact problem that appears during load operation; specified test load and operating conditions matter.

The 0.08 V drop at 4 A also represents contact heating: P=VI=0.08×4=0.32 W. If deterioration doubled that contact resistance while current stayed at 4 A, the drop would become 0.16 V and heating 0.64 W. A contact can therefore move correctly yet waste increasing power at its conducting surfaces. That is why a functional movement check and an appropriate loaded contact check answer different questions.

Connect symptoms to causes
SymptomCauses to investigate
No pull-inOpen winding, wrong coil supply, open control path
Chatter or loud humLow voltage, damaged shading ring, dirt or rust on pole faces
Failure to releaseWelded contacts, jamming, residual magnetism
Burned AC coilExcess voltage or armature held open

Use symptoms to choose the next check, not to declare a single cause without evidence. Welded contacts can keep a load connected with the coil off. Solid-state relays remove moving-contact wear and arcing, but have conducting voltage drop and heat, often need a heat sink, and can fail short-circuited. They also do not provide isolation for work.

Key Takeaways

  • Match coil supply and contact load ratings independently.
  • Compare coil resistance with specified values and temperature conditions.
  • OL identifies an open disconnected winding; normal resistance alone leaves other faults possible.
  • A click or continuity reading cannot establish full load-switching performance.
  • Judge contact voltage drop using known current and manufacturer limits.
  • Coil-off and an off command are not safe isolation.
4

Force from current and field

Current produces force when a conductor crosses a magnetic field. Calculate its size from field strength, current, length and angle, then use a direction rule to locate the force. Opposite forces can turn a motor coil or move a loudspeaker cone. The same interaction between current and field also acts between parallel conductors, explaining why high fault currents put severe mechanical loads on busbars and their supports.

4.1 Calculate a magnetic force and find its direction

A wire carrying current across a magnetic field experiences a force. This motor effect turns electrical input into mechanical action. Its size and its direction are separate questions.

Calculate the size

For a straight wire perpendicular to a uniform field:

F=B×I×l

F is force in newtons, B is flux density in teslas, I is current in amperes, and l is the length of wire inside the field in meters. Doubling one factor doubles the force when the others remain unchanged.

A wire carries 12 A through a 0.5 T field, with 0.15 m inside the field:

F=0.5×12×0.15=0.9 N

A total cable length of 2 m would not belong in this calculation if only 0.15 m crosses the field. Convert lengths such as 150 mm to 0.15 m before multiplying.

Include an angle

If the wire makes an angle θ with the field:

F=BIlsin⁡θ

The perpendicular part of the current produces the force. At 90°, sine is 1 and force is greatest. At 30°, sine is 0.5, so the same wire experiences 0.45 N. At 0°, the wire lies along the field and force is zero.

The angle is between the conductor's current direction and the field, not between the force and the field. The force itself is perpendicular to both current and field. A negative current direction should be handled by the direction rule while the magnitude calculation uses the current's size.

Use Fleming's left hand

Hold the left thumb, first finger and second finger mutually perpendicular:

  • First finger: field, N to S.
  • Second finger: conventional current.
  • Thumb: force or resulting motion.

Set the field and current fingers first, then read the thumb. Do not choose the thumb direction and twist the other fingers to make it fit. Fleming's right hand is a different rule for a conductor moved to generate voltage.

Work a direction example

Let the field point right across the page and current point into the page. Point the left first finger right and the second finger away from you. The thumb points down, so the force is down the page.

The circular field of this current is clockwise. Above the wire it adds to the rightward external field; below it, it opposes that field. The wire is pushed toward the weaker field below. This field pattern supports the hand-rule result.

Reverse the current alone and force is upward. Reverse the field alone and force is also upward. Reverse both and the two reversals cancel, leaving force downward again. Increasing current without reversing it changes the force's size, not its direction.

Key Takeaways

  • For a perpendicular wire, force is BIl and uses only the length inside the field.
  • At an angle, multiply by sin θ; a parallel wire has zero force.
  • Fleming’s left hand gives motor force from conventional current and N-to-S field.
  • Reversing one of current or field reverses force; reversing both leaves its direction unchanged.

4.2 Turn coils, move speakers and brace busbars

The motor effect can produce rotation, straight movement or a load on a support. In each case, current-carrying conductors experience force because they lie across a magnetic field.

Make a coil turn

The two active sides of a rectangular coil carry current in opposite directions. In the same external field, their forces point in opposite directions. Because the forces act on opposite sides of the shaft, they form a turning effect called torque.

Torque is greatest when the plane of the coil lies along the field. It falls to zero when the coil faces directly across the field. Position matters: a strong field and current do not give the same torque at every angle.

A simple DC motor uses a commutator, a split ring touched by brushes, to reverse coil current every half turn. As the sides exchange positions, their currents also reverse. The forces therefore continue to drive rotation in the same sense. Practical machines use many coils and an iron rotor to smooth the turning effect.

More current or a stronger field produces more torque. A heavily loaded or stalled motor can draw a large current, which is why protection must accommodate starting current while still protecting against sustained excess current.

Move a cone or a pointer

A loudspeaker's voice coil sits in the ring-shaped gap of a permanent magnet. Audio current changes direction, so magnetic force on the coil reverses with the signal. The attached cone moves back and forth, pushing air to produce sound. The permanent magnet need not reverse polarity for the cone to reverse motion.

A moving-coil meter also places a coil in a permanent magnetic field. A spring opposes its torque. The pointer settles where the spring balances the magnetic turning effect; deflection is proportional to current through the coil. The spring makes a steady reading possible instead of continuous rotation.

Two wires exert forces on each other

Each parallel conductor creates a field around itself. The other conductor lies in that field, so it experiences a force:

Parallel current directionsForce
Same directionAttraction
Opposite directionsRepulsion

A pair of loosely suspended wires can move toward or away from each other when large currents flow. The interaction comes from both currents, not from a permanent magnet nearby.

Why fault-current forces are severe

At fixed spacing and geometry, force is proportional to the product of the two currents. When both rise by the same factor, force rises by that factor squared. If a fault takes both currents to 50 times normal:

FfaultFnormal=50×50=2500

A support carrying the normal magnetic force may face 2,500 times that force during the fault. Busbars, cable supports and switchgear therefore need mechanical bracing as well as electrical current capacity. If only one conductor's current doubled while the other stayed fixed, force would double; the square relationship applies when both currents scale together.

Key Takeaways

  • Opposing forces on a coil produce torque; a commutator maintains rotation in a simple DC motor.
  • A speaker’s alternating coil current reverses the force on its cone.
  • A moving-coil meter balances magnetic torque against a spring.
  • Parallel currents attract when alike in direction and repel when opposite.
  • When both parallel currents scale together, their force scales with current squared.
5

Voltage from changing flux

Changing magnetic flux can produce voltage in a wire or coil. Learn to separate induced voltage from the current it can drive, calculate the voltage from the rate of change, and identify the opposing effect described by Lenz’s law. Generators, coupled windings, eddy currents and speed sensors apply this shared principle in different ways. Their operation depends on how flux changes, not simply on the presence of a strong magnet.

5.1 Produce and calculate an induced voltage

A magnet held still inside a coil can provide a strong field and produce no voltage. Electromagnetic induction requires a change in the flux linked with the conductor. That change can come from motion or from a changing current nearby.

Voltage first, current if a path exists

An induced emf is an induced voltage. It can exist across an open coil. A closed circuit then allows induced current to flow. Moving a magnet into a coil, moving a wire across a field, or changing current in a neighboring coil can produce emf. Steady linked flux produces none; motion along field lines does not cut them.

Faraday's law gives the magnitude of average emf during a flux change:

e=N∣ΔΦ∣Δt

N is turns, flux change is in webers, time in seconds and emf in volts. More turns, a larger flux change or a shorter time increases the result. For 200 turns and a 3 mWb change in 0.02 s:

e=200×0.0030.02=30 V

The same change over 0.2 s gives 3 V. The final field can be the same while the voltages differ, because the rate of change differs.

Move a straight conductor

When wire, motion and field are mutually perpendicular:

e=B×l×v

Use teslas, meters and meters per second. A 0.25 m wire moving at 8 m/s across 0.6 T gives:

e=0.6×0.25×8=1.2 V

For a wire perpendicular to both the motion and the field, but with motion at angle θ to the field lines, multiply by sin θ. At 30° the result is 0.6 V; along the field it is zero. The orientations of both the wire and its motion matter.

Find the opposing effect

Lenz's law says induced current acts to oppose the change producing it. Push a magnet's N pole toward a coil: the near coil end becomes N and repels the approaching pole. Withdraw that pole: the near end becomes S and attracts it, opposing withdrawal. The induced effect opposes change, so it can either reinforce or oppose the existing field depending on what is changing.

This opposition explains why a loaded generator is harder to turn. Mechanical work supplies electrical output; induction does not create energy.

Use Fleming's right hand

Hold the right thumb, first finger and second finger mutually perpendicular. The thumb follows motion, the first finger follows field from N to S, and the second finger gives induced conventional current in a closed circuit.

With field right and motion up the page, the second finger points into the page. Mark that current with a cross. Reversing motion or field reverses induced polarity. Use the right hand when motion produces electrical output; use the left when current produces force.

Key Takeaways

  • Changing flux linkage induces emf; a closed path is needed for induced current.
  • Faraday’s law uses turns and flux change per second.
  • The simple Blv formula requires wire, motion and field to be mutually perpendicular.
  • Lenz’s law opposes the change and accounts for the mechanical work of generation.
  • Fleming’s right hand gives generator current direction.

5.2 Use induction in generators and sensors

Induction works whenever linked flux changes. Rotating a coil, changing current in a nearby winding, or passing a steel tooth near a sensor can all provide that change.

Generate a repeating voltage

A simple AC generator rotates a coil in a magnetic field, or a magnet within fixed coils. The induced emf reverses every half turn. At constant speed in a uniform field, the simple coil produces a sinusoidal voltage.

The largest emf occurs where flux changes fastest: when the plane of the coil lies along the field and linked flux passes through zero. When the coil faces across the field, flux is greatest but momentarily changes at zero rate, so emf is zero. Maximum flux and maximum emf occur at different positions.

For a generator with one pole pair, one revolution produces one cycle:

f=revolutions per minute60

At 3,000 r/min the frequency is 50 Hz; at 3,600 r/min it is 60 Hz. The one-pole-pair condition belongs with this simple relationship.

Slip rings take the rotating coil's alternating output to brushes without reversing its connections. A commutator reverses those connections every half turn, giving the external circuit a pulsating direct voltage. The coil's induced emf still alternates.

Reverse the energy flow

A motor converts electrical input into mechanical work. When its shaft is driven mechanically, a suitable machine can generate electrical output. During regenerative braking, a vehicle's wheels drive the machine and energy returns toward the battery. This reverses energy conversion; it does not require the vehicle or shaft to reverse its direction of rotation.

Link two coils

With mutual induction, changing current in one coil changes the flux linking a second coil and induces emf there. A shared iron core improves magnetic coupling. AC repeatedly changes current and supports transformer action. Steady DC in the first coil produces no continuing emf in the second; switching transients can produce brief pulses.

Currents within a metal part

Changing flux can drive loops of eddy current inside solid metal. The currents heat the metal. Thin core laminations, insulated from each other, interrupt large current paths and reduce unwanted heating in AC equipment.

Eddy currents are useful too. They heat suitable cookware on an induction cooktop and produce drag in non-contact brakes. Metal detectors and inductive proximity sensors detect changes in a coil's field caused by nearby metal.

Sense teeth passing a coil

A passive variable-reluctance speed sensor has a coil and permanent magnet facing a toothed steel ring. Each tooth changes the magnetic path and flux, inducing a pulse. More teeth pass per second at higher speed, so pulse frequency rises. The faster flux change also raises signal size. At very low speed the signal becomes weak; newer active sensors can avoid that low-speed limitation.

Key Takeaways

  • A generator’s emf depends on flux-change rate, not flux alone.
  • One pole pair gives one electrical cycle per revolution.
  • Slip rings preserve AC output; a commutator gives pulsating DC externally.
  • Mutual induction requires changing flux shared by two coils.
  • Laminations reduce unwanted eddy currents; heating and braking can use them.
  • A passive toothed-ring sensor produces weaker, slower signals at low speed.
6

Self-inductance and switching

A coil responds when its own current changes: its magnetic field stores energy and produces a voltage that opposes the change. Inductance sets that response, while resistance helps set the time scale of a DC circuit. Follow a coil from switch-on to steady current and then to switch-off. The energy released at opening explains both useful ignition pulses and the need for suppression that protects contacts and electronic drivers.

6.1 Follow current as a coil switches on

A changing current changes a coil's own magnetic flux. That changing flux induces voltage in the same winding. Self-induction makes the coil oppose changes in current, delaying its rise and sustaining it during switch-off.

Measure inductance

Inductance L measures flux linkage per ampere:

L=NΦI

Its unit is the henry (H). For 400 turns, 2.5 mWb and 5 A:

L=400×0.00255=0.2 H

More turns, a larger core area, higher permeability or a shorter magnetic path increases inductance for otherwise unchanged geometry and material behavior. Turns have a square effect: doubling them gives four times L. An air gap lowers inductance.

Calculate back emf

The magnitude of self-induced emf is:

e=L∣ΔI∣Δt

One henry gives 1 V for a current change of 1 A each second. In a 0.5 H coil, a fall from 2 A to zero in 5 ms gives:

e=0.5×20.005=200 V

Lenz's law supplies the direction. At switch-on, back emf opposes the rising current. At switch-off, its polarity supports current in the original direction as it falls. It opposes the change, not current at every moment.

Account for stored energy

Energy is stored in the magnetic field:

W=12LI2

The 0.5 H coil carrying 2 A stores 1 J. Doubling current would store four times as much energy at unchanged L. When the coil is switched off, that energy must be transferred elsewhere, for example into winding heat or a suppression circuit.

Find the DC time constant

For a fixed inductance and total series resistance:

τ=LR

The time constant is in seconds. After one time constant, switch-on current has reached about 63% of its final value. After five it is practically at its final value. The rising curve becomes less steep as the current approaches its limit.

Take a 12 V supply, 0.2 H coil and 10 Ω resistance. The final current and time constant are:

Ifinal=12/10=1.2 A,τ=0.2/10=0.02 s

After 20 ms the current is about 0.76 A. After 100 ms it is nearly 1.2 A. The final current comes from V/R; the time to approach it comes from L/R. Increasing resistance shortens the time constant but also lowers final current at the same voltage.

A lamp in series with a suitable iron-cored coil can light later than an identical lamp with an equal-resistance resistor. Back emf delays current in the coil branch. Once DC current is steady, its flux is steady too: self-induced emf is zero, and winding resistance sets the current. The coil has not lost its inductance; there is simply no current change for it to oppose.

Key Takeaways

  • Self-induced emf opposes a change in the coil’s own current.
  • Inductance is NΦ/I; induced-emf magnitude is L times the rate of current change.
  • Magnetic energy is ½LI² and must be released at switch-off.
  • The DC time constant is L/R, while final current is V/R.
  • Current reaches about 63% after one time constant and nearly its final value after five.
  • Steady DC produces no self-induced emf.

6.2 Control the energy at switch-off

Opening a coil circuit tries to stop current very quickly. The coil's collapsing field induces a voltage that supports the falling current. Without a controlled path for that energy, the voltage can rise enough to arc across contacts or damage electronics.

A small supply can produce a large spike

The relationship is:

∣e∣=L∣ΔI∣Δt

A shorter stopping time gives a larger emf for the same current change. A 12 V or 24 V coil can therefore generate hundreds of volts at switch-off. This voltage is not limited to the supply rating: it comes from the rapid release of stored magnetic energy.

A coil can produce a visible spark where a resistor carrying similar current gives little spark. In a protected classroom setup, a neon indicator needing about 70–90 V can flash across a coil supplied by a 1.5 V cell when its circuit opens. Such demonstrations reveal the spike; they are not a reason to touch coil terminals or pull live connectors.

Arcing pits contacts. The spike can also damage insulation, disturb nearby electronics, destroy a transistor or PLC output, and cause shock. Use the proper switch, keep clear of terminals during switching, let energy dissipate, then isolate, lock out and verify absence of voltage before touching the circuit.

For a fixed 0.08 H coil carrying 0.5 A, the initial energy is W=12×0.08×0.52=0.01 J. Stopping the current in 0.4 ms gives an average induced magnitude of 100 V; allowing 4 ms gives 10 V. The energy at the start is unchanged. These are two independent suppression requirements: the circuit must tolerate the voltage and provide a destination for the full released energy.

Use the pulse deliberately

A gasoline engine's ignition coil builds current in a primary winding, then interrupts it. Collapsing flux induces emf; a secondary winding with many turns develops the tens of thousands of volts needed at the spark plug. Self-induction in the primary and mutual induction into the secondary work together.

In an older fluorescent fitting, the starter opens and the choke produces a pulse to strike the tube. During operation the choke limits AC current. The pulse is useful only because the surrounding circuit is designed for it.

Give DC current a return path

A flyback diode connects across a DC coil, reverse-biased during normal operation. Its cathode, usually marked by a band, connects to the coil's positive side. It normally blocks current.

At switch-off the coil's polarity reverses and drives current around the coil-diode loop. Energy is dissipated mainly in winding resistance, with some diode loss. A conducting silicon diode holds the reversed coil voltage near its forward drop, typically below about 1 V at suitable current. The current decays over time, so release becomes slower.

Connecting this diode forward across the supply creates a short circuit. Putting one directly across an AC coil makes it conduct during one half-cycle. A plain flyback diode is therefore a DC solution, with polarity essential.

Choose other suppression when needed

An RC snubber places a resistor and capacitor in series to absorb a transient. A varistor or suitable bidirectional transient-suppression diode clamps voltage at a selected level. These can serve AC coils and DC applications needing faster release than a plain diode permits. Use a device or plug-in A1–A2 module rated for the actual coil and driver. A clamp limits voltage; it still has to handle the stored energy and meet the required release time.

Key Takeaways

  • An interrupted coil can produce a voltage far above its supply voltage.
  • Ignition coils and older lamp chokes use induced pulses deliberately.
  • A DC flyback diode is reverse-biased during normal operation, with cathode at coil positive.
  • The diode provides a decay path and slows release.
  • AC coils need suitable suppression such as an RC snubber or varistor.

Magnetism and Electromagnetic Induction examples

6 Walkthroughs

1

Read a field and calculate its flux

13 steps
Use poles, field diagrams, area conversions and magnetic materials to understand a relay’s magnetic path.
  1. 1
    IntroductionStart with the physical change

    A magnet can attract steel without touching it. A field drawing shows where this influence points and where it is concentrated. We will read that drawing, calculate flux through a pole face, and choose a material that can change its magnetism easily. Keep two questions separate: how much total flux passes through a face, and how concentrated is that flux?

  2. 2
    ExplanationIdentify poles by their forces

    Every magnet has N and S poles. Like poles repel; unlike poles attract. Cutting it produces smaller magnets with both poles.

    A known magnet attracts ordinary iron too. Repulsion is the useful test that identifies another magnet and a like facing pole.

  3. 3
    ExampleAdd arrows to a field pattern

    Outside a bar magnet, draw arrows from N to S. Inside it, the lines continue S to N, closing each loop. Lines do not cross, and closer spacing shows greater strength.

    A compass supplies the arrows because its north end follows the field. Filings show the curved pattern but no direction. Across a narrow gap between unlike poles, nearly parallel, evenly spaced lines show a nearly uniform field.

  4. 4
    ChallengeInterpret an unfamiliar pole

    A known S pole repels the left end of a small bar. What pole is that end, and which way would a compass’s north end point just outside it?

    ---reveal---

    The left end is S, because like poles repel. A compass’s N end points toward it along the outside field. Attraction alone would not have identified the bar as a magnet, but repulsion does. Use the same outside N-to-S convention when adding arrows to a diagram.

  5. 5
    ExplanationSeparate total flux from concentration

    Flux Φ is total magnetic field through an area, in webers. Flux density B is flux per square meter, in teslas. For a uniform field perpendicular to the area:

    Φ=BA

    A wider face carries more flux at unchanged B. A smaller face carrying unchanged flux has greater B. Those are different changes, so decide which quantity is fixed before predicting the result.

  6. 6
    ExampleConvert both sides of a pole face

    A pole face measures 25 mm by 20 mm. Convert each side to meters before multiplying:

    A=0.025×0.020=0.0005 m2

    Alternatively, its area is 500 mm² and each mm² is one millionth of a m². This gives the same 0.0005 m². Using the millimeter-to-meter factor only once would be a length conversion applied to an area.

  7. 7
    ExampleUse the converted area

    Keep that 0.0005 m² face and give it a uniform perpendicular flux density of 0.8 T:

    Φ=0.8×0.0005=0.0004 Wb

    That is 0.4 mWb. Multiplying concentration by area gives a total. As a reverse check, divide 0.0004 Wb by 0.0005 m² and recover 0.8 T. Tilting the face would reduce the flux through it, so the stated orientation is part of the calculation.

  8. 8
    ChallengeFind density from a new face

    A core carries 0.63 mWb through a 14 cm² cross-section, uniformly and perpendicularly. What flux density does it carry?

    ---reveal---

    Convert to 0.00063 Wb and 0.0014 m², then divide:

    B=0.00063/0.0014=0.45 T

    The area conversion squares the centimeter-to-meter factor. Dividing flux by area, instead of multiplying them, answers the question about concentration.

  9. 9
    AnalogyPicture domains adding together

    Think of magnetic domains as many tiny compass-like regions inside a material. If their directions largely cancel, the whole piece has little net magnetism. An applied field lines many up so their contributions add.

    This is a model of magnetic alignment, not loose needles moving through the metal. When most domains that can align have done so, the material is saturated and extra effort adds little flux density.

  10. 10
    ExplanationChoose a core that can change

    Soft magnetic materials have low coercivity: a small opposing field can demagnetize them. This suits relay and AC cores. Hard magnetic materials resist demagnetization and suit permanent magnets.

    Soft does not mean zero residual magnetism. Remanence can still hold an armature against its core. A non-magnetic stop gap reduces this unwanted holding effect. Repeated reversal also produces hysteresis heat, reduced by suitable soft material.

  11. 11
    ChallengeExplain a release problem

    A relay’s supply is removed and coil current has decayed, but residual magnetic attraction holds its armature closed. Why is replacing the core with a hard permanent-magnet material a poor response?

    ---reveal---

    The problem is retained attraction, and a hard magnetic material resists demagnetization. A suitable soft magnetic core is easier to demagnetize; a small non-magnetic gap helps reduce residual holding force. The ability to magnetize strongly is not the only useful selection property for a relay that must release.

  12. 12
    ChallengeConnect material and field measurements

    Two soft cores carry the same uniform perpendicular flux. Core Q has half the cross-sectional area of P. Which has greater flux density, and why might increasing the magnetizing current eventually give little further increase?

    ---reveal---

    Q has twice the flux density because B=Φ/A at unchanged flux. Further current can eventually bring a core near saturation, where extra magnetizing effort adds little B. The area comparison describes concentration; saturation describes how the material responds to additional effort.

  13. 13
    RecapKeep the useful distinctions

    Use repulsion to identify a magnet and a compass to give field arrows. Keep flux separate from flux density, convert area to m², and preserve the perpendicular-field condition. For changing fields, choose soft magnetic material for easy reversal; allow for remanence and saturation when explaining real magnetic behavior.

2

Build a field that can pull a plunger

15 steps
Find coil polarity, calculate magnetizing effort and explain AC and DC actuator behavior.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart with the physical change
  2. 2
    ExplanationUse the wire grip rule
  3. 3
    TipSwap the roles for a coil
  4. 4
    ChallengeFollow a supply reversal
  5. 5
    ExampleCalculate ampere-turns
  6. 6
    ExampleFind field strength along a path
  7. 7
    ExampleInclude permeability
  8. 8
    Key InsightA short air gap can dominate
  9. 9
    ChallengeChoose the complete calculation
  10. 10
    ConnectionTurn pull into a useful stroke
  11. 11
    ExplanationUnderstand AC inrush
  12. 12
    ExplanationKeep some pull through AC zeros
  13. 13
    ChallengeDiagnose without changing the voltage rating
  14. 14
    ChallengeConnect resistance with a weak pull
  15. 15
    RecapKeep the useful distinctions
3

Trace a start-and-stop control circuit

18 steps
Follow relay states, separate coil and contact currents, and check a holding circuit and device ratings.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart with the physical change
  2. 2
    ExplanationSeparate control from power
  3. 3
    ExplanationRead contacts with the coil off
  4. 4
    ChallengeRead a changeover path
  5. 5
    ExampleFind the control current
  6. 6
    ExampleCalculate the fan path separately
  7. 7
    TipIdentify the contactor paths
  8. 8
    ExplanationSet up the holding circuit
  9. 9
    ExampleRelease START, then press STOP
  10. 10
    ChallengeCheck the location of a bypass
  11. 11
    Key InsightA power failure breaks the holding path
  12. 12
    ConnectionBlock an opposing contactor
  13. 13
    ExampleRead both sets of ratings
  14. 14
    TipCheck a winding as one part of diagnosis
  15. 15
    ChallengeUse a specified contact test
  16. 16
    Key InsightDo not turn an off command into isolation
  17. 17
    ChallengeCombine a rating with a circuit state
  18. 18
    RecapKeep the useful distinctions
4

Predict force, rotation and busbar stress

12 steps
Calculate conductor force, use the left-hand rule and scale forces when both conductor currents rise.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart with the physical change
  2. 2
    ExplanationSeparate size and direction
  3. 3
    ExampleWork the perpendicular case
  4. 4
    ExampleTurn the wire toward the field
  5. 5
    TipSet the left hand in order
  6. 6
    ChallengeChoose the active length and direction
  7. 7
    ExplanationArrange forces to turn a coil
  8. 8
    ConnectionLet a signal move a cone or pointer
  9. 9
    ExplanationLet each conductor supply the other’s field
  10. 10
    ChallengeScale two unequal current changes
  11. 11
    ChallengeCombine an angle with a current change
  12. 12
    RecapKeep the useful distinctions
5

Make voltage from changing flux

14 steps
Calculate induced emf and connect Lenz’s law to generators, coupled coils and passive speed sensors.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart with the physical change
  2. 2
    ExplanationFind what changes the linked flux
  3. 3
    ExampleCalculate the flux change per second
  4. 4
    ExampleMultiply the rate by turns
  5. 5
    Key InsightOppose approach and withdrawal differently
  6. 6
    ChallengeInfer a new rate and magnetic response
  7. 7
    ExampleMove a wire and find its current direction
  8. 8
    ExplanationTurn a coil through a field
  9. 9
    ExampleMatch rotation and output connections
  10. 10
    ConnectionChange which way energy moves
  11. 11
    ExplanationLink a second winding or a metal loop
  12. 12
    ChallengeExplain a passive speed signal
  13. 13
    ChallengeConnect generation with the load
  14. 14
    RecapKeep the useful distinctions
6

Switch a coil without losing track of its energy

14 steps
Follow a DC coil’s rise, calculate its stored energy and induced voltage, and choose the principle of suitable suppression.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart with the physical change
  2. 2
    ExplanationOppose a change, not every current
  3. 3
    ExampleCalculate inductance from linkage
  4. 4
    ExampleFind final current separately from delay
  5. 5
    ExampleRead one and five time constants
  6. 6
    ChallengeFind current after 20 ms
  7. 7
    ExamplePut a number on stored energy
  8. 8
    ExampleMake the stopping time visible
  9. 9
    ConnectionUse a pulse when the circuit needs one
  10. 10
    ExplanationLet a diode carry the decay current
  11. 11
    ChallengeSpot a polarity error
  12. 12
    TipChoose a clamp for the job
  13. 13
    ChallengeConnect stored energy with the clamp
  14. 14
    RecapKeep the useful distinctions

Magnetism and Electromagnetic Induction practice questions

60 Practice Questions in 6 sets

Set 1: Electromagnet strength and actuator behavior10 Practice Questions

Question 1 of 10

A coil has 750 turns and carries 0.2 A. What is its magnetomotive force?
  1. 3,750 At
  2. 0.00027 At
  3. 750.2 At
  4. 150 At
Show answerHide answer
Answer: D
Mmf is 750×0.2=150 At. Dividing the turns by current gives 3,750, but magnetizing effort depends on their product.

Question 2 of 10

Viewed from one end, a coil carries counterclockwise conventional current. What pole is that end?
  1. South
  2. North
  3. A neutral point
  4. An alternating pair of poles
Show answerHide answer
Answer: B
Curl the right fingers with the counterclockwise current; the thumb points toward you, so that end is N. Clockwise current would make the same viewed end S.

Question 3 of 10

An AC solenoid’s plunger jams fully out. What electrical behavior can damage the coil?
  1. Its holding current drops to zero
  2. Its supply frequency doubles
  3. Its high inrush current persists
  4. Its coil resistance becomes infinite
Show answerHide answer
Answer: C
The open armature leaves a large air gap and low inductance, so the AC coil can keep drawing its high inrush current. Once seated, it would normally draw a lower holding current. Treating the jam as an open electrical circuit misses that the winding is still connected to the supply.

Question 4 of 10

A 24 V DC coil has 120 Ω resistance and 900 turns. What mmf does it produce at steady current?
  1. 180 At
  2. 108 At
  3. 216 At
  4. 4,500 At
Show answerHide answer
Answer: A
Current is 24/120=0.2 A, so mmf is 900×0.2=180 At. Using 24 as the current would confuse volts with amperes.

Question 5 of 10

How often does the main magnetic flux of a 60 Hz AC electromagnet pass through zero?
  1. 30 times per second
  2. 60 times per second
  3. 120 times per second
  4. 240 times per second
Show answerHide answer
Answer: C
Each AC cycle crosses zero twice, giving 120 crossings per second at 60 Hz. Counting 60 assigns only one crossing to each full cycle.

Question 6 of 10

Two coils each produce 240 At. Coil P has a 0.12 m uniform magnetic path and Q a 0.24 m path. How do their field strengths compare?
  1. P has half Q’s field strength
  2. P has twice Q’s field strength
  3. P has four times Q’s field strength
  4. P and Q have equal field strength
Show answerHide answer
Answer: B
Field strength is mmf divided by magnetic-path length. P gives 240/0.12=2000 A/m and Q gives 1,000 A/m, so P is twice Q. Equal ampere-turns alone do not ensure equal H; the same effort is distributed along different path lengths.

Question 7 of 10

Why can a solenoid hold a seated plunger but fail to pull it in from its fully extended position?
  1. The seated winding has fewer turns
  2. The spring becomes a permanent magnet
  3. The extended plunger reverses the supply
  4. The larger starting air gap weakens pull
Show answerHide answer
Answer: D
A large air gap has high reluctance and gives weaker starting attraction. Once seated, the small gap allows a stronger holding pull from the same coil. A holding-force rating therefore cannot by itself establish adequate starting force over a long stroke; the turn count does not change with plunger position.

Question 8 of 10

A uniform closed core has a 0.20 m magnetic path and relative permeability 300 at its operating point. A 1,000-turn coil of 150 Ω is connected to 30 V DC. Approximately what flux density results? Use μ₀ = 1.257 × 10⁻⁶ H/m.
  1. 0.377 T
  2. 0.0754 T
  3. 1.89 T
  4. 0.00126 T
Show answerHide answer
Answer: A
The current is 30/150=0.2 A, giving 200 At and H=200/0.20=1000 A/m. Multiplying H by μ₀ and 300 gives about 0.377 T. The 0.00126 T result leaves out the core’s relative permeability; it describes the corresponding air-core calculation.

Question 9 of 10

A 10 A type C breaker carries a sustained 70 A fault. A 10 A type B device is considered instead. How does 70 A compare with their magnetic bands?
  1. Above C’s upper threshold; within B’s magnetic band
  2. Within C’s band; above B’s upper magnetic threshold
  3. Within both magnetic bands; neither has reached its upper threshold
  4. Below C’s lower threshold; within B’s magnetic band
Show answerHide answer
Answer: B
Type C’s band is 50–100 A and type B’s is 30–50 A for these 10 A devices. Thus 70 A lies within C’s band but above B’s upper threshold. Applying the same band to both types would miss why their rapid magnetic responses differ; “instantaneous” still allows a finite specified operating time.

Question 10 of 10

A 20 V DC electromagnet has 500 turns and a winding resistance that rises from 40 Ω to 50 Ω. An 800-turn replacement must match the original coil’s warm mmf. What mmf is required, and what replacement current achieves it?
  1. 250 At, requiring 0.3125 A
  2. 320 At, requiring 0.40 A
  3. 200 At, requiring 0.25 A
  4. 200 At, requiring 0.40 A
Show answerHide answer
Answer: C
The original warm current is 20/50=0.4 A, so the required mmf is 500×0.4=200 At. An 800-turn winding needs 200/800=0.25 A to match it. Using the original cold current gives 250 At and misses the requested warm operating condition.
Set 2: Fields, flux and magnetic materials10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A known N pole repels one end of a small bar. What is that end of the bar?
  1. A south magnetic pole
  2. An unmagnetized iron end
  3. A north magnetic pole
  4. An unmagnetized copper end
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A uniform 0.6 T field passes perpendicularly through 0.003 m². What flux passes through it?
  1. 1.8 mWb
  2. 0.2 mWb
  3. 5 mWb
  4. 180 mWb
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

What magnetic property makes a material suitable for a relay core that must demagnetize easily?
  1. High coercivity
  2. High retentivity
  3. Wide hysteresis
  4. Low coercivity
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A dot marks conventional current in a wire viewed end-on. How does its field circulate in that view?
  1. Clockwise around the wire
  2. Counterclockwise around the wire
  3. Radially outward from the wire
  4. Radially inward toward the wire
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A uniform perpendicular flux of 0.72 mWb passes through a core of 12 cm². What is the flux density?
  1. 0.060 T
  2. 0.60 T
  3. 6.0 T
  4. 0.0060 T
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Two identical magnets are placed symmetrically with N poles facing across a gap. What is the net field exactly midway between the facing poles?
  1. Strong and toward the left magnet
  2. Strong and toward the right magnet
  3. Uniform, because both poles are N
  4. Zero, because equal fields oppose
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A relay coil is switched off, but residual attraction keeps the armature seated. What design feature directly reduces that sticking?
  1. A small non-magnetic stop gap
  2. A hard magnetic armature insert
  3. A larger permanent magnet on the core
  4. A thicker copper supply conductor
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

Viewed from the right end of a coil, conventional current circles clockwise. What happens to that end when the supply polarity reverses?
  1. It changes from N to S
  2. It stays S while strength reverses
  3. It changes from S to N
  4. It stays N while current reverses
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

Iron filings show curved lines around a bar magnet, but no arrows. What observation supplies the field direction at a chosen point?
  1. The direction of a compass’s north end
  2. The longest visible chain of filings
  3. The direction of a compass’s south end
  4. The spacing of neighboring filing chains
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A uniform perpendicular field sends 0.96 mWb through a 24 mm by 50 mm pole face. A second face carries the same flux at 1.6 T. What is the second face’s area compared with the first?
  1. Twice the first area
  2. Half the first area
  3. Same as the first area
  4. Quarter the first area
Show answerHide answer

Save this lesson to see this answer.

Set 3: Relay contacts, holding circuits and fault checks10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

With a typical vehicle changeover relay de-energized, which terminal is connected to common terminal 30?
  1. Terminal 87
  2. Terminal 86
  3. Terminal 85
  4. Terminal 87a
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A contactor auxiliary contact is marked 13–14. What is its state with the coil off?
  1. Closed
  2. Open
  3. Connected to A1
  4. Connected to the main pole 1–2
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 12 V, 180 Ω relay coil controls a separate 12 V, 84 W pump. Approximately what currents pass through the coil and the closed load contact?
  1. 0.067 A and 7 A
  2. 7 A and 0.067 A
  3. 0.067 A and 0.067 A
  4. 7 A and 7 A
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A START button, NC STOP button and NO holding contact form a working self-holding circuit. What prevents restart when power returns after a supply failure?
  1. The holding contact has closed and STOP remains open
  2. The coil retains its full current while supply is absent
  3. The holding contact has opened and START remains open
  4. The NC STOP contact becomes NO after the failure
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A disconnected relay coil specifies 360 Ω at room temperature. At that temperature it reads OL on a working ohmmeter. What fault does this indicate?
  1. An open winding
  2. A welded contact
  3. A shorted winding
  4. A low coil voltage
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

In a proposed control circuit, NC STOP and NO START are in series with a coil, but the coil’s NO auxiliary contact is wired across STOP. START is held down until the contactor closes. What happens when STOP is then pressed while START is still held?
  1. The coil drops out and the auxiliary stays closed
  2. The coil drops out and cannot start again
  3. The coil reverses current through the START path
  4. The coil stays on through the auxiliary bypass
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 400 V three-phase motor draws 14 A running current and uses 24 V DC control. Candidate P has a 24 V AC coil and 18 A AC-3 contacts; Q has a 24 V DC coil, 25 A AC-1 and 12 A AC-3 contacts; R has a 24 V DC coil and 18 A AC-3 contacts. All listed contact ratings apply at 400 V. Which candidate meets both stated requirements?
  1. P
  2. R
  3. Q
  4. P and Q
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A relay data sheet states pull-in at 8.5 V and drop-out below 1.0 V. The coil supply is 6 V. What explains a relay that stays held at 6 V but fails to start from rest at 6 V?
  1. Six volts is above pull-in but below drop-out
  2. A closed load contact supplies the missing coil voltage
  3. Six volts is below pull-in but above drop-out
  4. A held armature changes the coil supply from DC to AC
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

At the manufacturer’s specified contact test conditions, 5 A produces a 0.15 V drop across a closed relay contact. The limit is 0.020 Ω. How should this result be judged?
  1. 0.030 Ω, below the limit
  2. 0.003 Ω, below the limit
  3. 0.750 Ω, above the limit
  4. 0.030 Ω, above the limit
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

Contactor K1 has an NC auxiliary contact in series with K2’s coil. What happens to K2’s coil path when K1 energizes?
  1. It opens, blocking K2 from energizing
  2. It closes, commanding K2 to energize
  3. It changes K2’s coil voltage to K1’s voltage
  4. It bypasses K2’s stop and overload contacts
Show answerHide answer

Save this lesson to see this answer.

Set 4: Motor force and fault-current loads10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

Both currents in a fixed pair of parallel conductors rise from 30 A to 180 A. By what factor does magnetic force change?
  1. 6 times
  2. 12 times
  3. 216 times
  4. 36 times
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 1.2 m wire includes 0.16 m in a uniform 0.75 T field. It carries 10 A perpendicular to the field. What force acts on it?
  1. 9.0 N
  2. 0.12 N
  3. 1.2 N
  4. 7.5 N
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A perpendicular wire carries 8 A through a uniform 0.3 T field, with 0.20 m inside it. What force acts on the wire?
  1. 0.48 N
  2. 4.8 N
  3. 12 N
  4. 0.048 N
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

Two parallel busbars carry current in opposite directions. Do they attract or repel?
  1. They attract
  2. Fields cancel
  3. They repel
  4. Neither
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A uniform magnetic field points up the page and conventional current flows out of the page. What direction is the force?
  1. Right across the page
  2. Left across the page
  3. Up the page
  4. Down the page
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A straight wire lies in the page and initially carries rightward current through a uniform field directed up the page. Its active length is 0.24 m, current 5 A and field 0.8 T. The current is doubled, the field reversed, and the wire rotated in the page so its current points up-right at 30° to the original upward field. What are the new force size and direction compared with the initial force?
  1. Same size; opposite sense
  2. Twice the size; opposite sense
  3. Same size; same sense
  4. Half the size; opposite sense
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A speaker coil’s active length stays fixed. Its field magnitude halves without reversing, while current changes from +0.4 A to −0.2 A. How does its new force compare with the original force?
  1. Opposite direction and twice the magnitude
  2. Same direction and one quarter the magnitude
  3. Opposite direction and half the magnitude
  4. Opposite direction and one quarter the magnitude
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A uniform 0.4 T field points left across the page. A perpendicular wire with 0.25 m inside must experience 0.6 N upward. What conventional current is required?
  1. 6 A out of the page
  2. 6 A into the page
  3. 0.6 A into the page
  4. 0.6 A out of the page
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A wire’s current and magnetic field are both reversed without changing their sizes or relative angle. What happens to its magnetic force?
  1. It keeps its size but reverses direction
  2. It doubles without changing direction
  3. It keeps its size and direction
  4. It falls to zero at the reversal
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

In fixed busbar geometry, normal currents are 40 A and 60 A. During a fault they become 800 A and 900 A with their directions unchanged. How many times larger is the force?
  1. 35 times
  2. 300 times
  3. 400 times
  4. 225 times
Show answerHide answer

Save this lesson to see this answer.

Set 5: Generators, changing flux and sensors10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A magnet rests inside an open coil without moving or changing strength. What continuing emf is induced?
  1. A steady positive emf
  2. Zero emf
  3. A steady negative emf
  4. An alternating emf
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

What does insulating thin core laminations mainly reduce in an AC electromagnet?
  1. Large circulating eddy currents
  2. The winding’s number of turns
  3. The supply’s number of cycles
  4. The need for any magnetic flux
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

Flux through a 300-turn coil falls from 2.0 mWb to 0.5 mWb in 0.03 s. What is the average emf magnitude?
  1. 20 V
  2. 5 V
  3. 25 V
  4. 15 V
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A magnet’s S pole is withdrawn from the near end of a closed coil. What pole is induced at that near end?
  1. South, repelling the withdrawing S pole
  2. North, repelling the withdrawing S pole
  3. North, attracting the withdrawing S pole
  4. South, attracting the withdrawing S pole
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A simple rotating-coil AC generator reaches its maximum linked flux. What is its emf at that instant?
  1. Maximum, because flux itself is maximum
  2. Half maximum, because rotation continues
  3. Maximum, because the field is unchanged
  4. Zero, because flux change is momentarily zero
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A 0.30 m conductor is perpendicular to both a uniform 0.5 T field and its motion. It must generate 0.9 V. The field points down the page and motion is rightward. What speed and induced conventional current direction result in a closed circuit?
  1. 6 m/s, out of the page
  2. 6 m/s, into the page
  3. 0.6 m/s, into the page
  4. 0.6 m/s, out of the page
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A generator with one pole pair runs at 2,400 r/min. It has slip rings. A redesign doubles the shaft speed and replaces the slip rings with a commutator. What happens to the internal coil-emf frequency and the external output polarity?
  1. Frequency doubles; output has one polarity
  2. Frequency stays fixed; output has one polarity
  3. Frequency doubles; output alternates polarity
  4. Frequency halves; output alternates polarity
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

Coil P has 150 turns and its flux rises from 1 to 5 mWb in 20 ms. Coil Q has 300 turns and its flux falls from 5 to 2 mWb. How long must Q’s change take to give the same emf magnitude as P?
  1. 10 ms
  2. 15 ms
  3. 30 ms
  4. 40 ms
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A nearby secondary coil receives pulses only when a DC primary is switched on or off. What explains the lack of a signal while the primary current is steady?
  1. Steady primary current gives steady shared flux
  2. The secondary becomes an open circuit on DC
  3. The shared core has no field during steady DC
  4. The primary reverses polarity only while steady
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A passive toothed-ring speed sensor gives a weak, low-frequency signal as the shaft slows, with tooth spacing unchanged. Why can a controller lose this signal before the shaft stops?
  1. Voltage falls but frequency stays unchanged
  2. Frequency falls but voltage stays unchanged
  3. Both fall because the permanent magnet grows weaker
  4. Slower flux change reduces voltage as well as pulse frequency
Show answerHide answer

Save this lesson to see this answer.

Set 6: Self-inductance, stored energy and suppression10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A coil’s DC current has become steady. What self-induced emf is produced by that steady current?
  1. An emf at supply level
  2. An emf from turn count
  3. Zero self-induced emf
  4. A steadily rising emf
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Where does the cathode of a plain flyback diode connect across a DC coil?
  1. To the negative coil terminal
  2. In series with the coil return
  3. In series with the positive supply
  4. To the positive coil terminal
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

An 800-turn coil carries 4 A and has 1.5 mWb flux per turn at that current. What is its inductance?
  1. 0.30 H
  2. 0.0030 H
  3. 3.0 H
  4. 0.075 H
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

An ordinary diode is proposed directly across a 24 V AC contactor coil. Why is this unsuitable?
  1. It blocks both halves of the supply cycle
  2. It conducts during one supply half-cycle
  3. It removes the coil’s magnetic inductance
  4. It makes the supply frequency twice as large
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A fixed 0.24 H, 12 Ω coil is switched onto 24 V DC. Approximately what current flows after one time constant, and when is the current practically final?
  1. 1.26 A after 20 ms; nearly final at 100 ms
  2. 2.00 A after 20 ms; nearly final at 100 ms
  3. 1.26 A after 50 ms; nearly final at 250 ms
  4. 0.63 A after 20 ms; nearly final at 100 ms
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A 0.30 H coil carries 1.2 A. Its current is interrupted to zero over 2 ms; a second arrangement takes 12 ms. What are the average induced-emf magnitudes, and what happens to the initial stored energy between these arrangements?
  1. 30 V and 180 V; initial energy is unchanged
  2. 180 V and 30 V; initial energy falls sixfold
  3. 180 V and 30 V; initial energy is unchanged
  4. 30 V and 180 V; initial energy rises sixfold
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

Two fixed 0.40 H coils use the same 20 V DC supply. P has 10 Ω total series resistance; Q has 20 Ω. After steady current is reached, how do Q’s stored energy and its switch-on time constant compare with P’s?
  1. Energy halves; time constant halves
  2. Energy quarters; time constant halves
  3. Energy quarters; time constant doubles
  4. Energy halves; time constant doubles
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A relay’s release becomes too slow after a plain flyback diode is fitted, although the driver is protected. The supply and coil are unchanged. What explains the delay, and what change should be evaluated?
  1. The low clamp slows decay; evaluate an even lower-voltage clamp
  2. The low clamp speeds decay; evaluate a higher-voltage clamp
  3. The low clamp slows decay; evaluate a higher diode current rating
  4. The low clamp slows decay; evaluate a suitably higher-voltage clamp
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A fixed 0.16 H coil’s current rises from 1 A to 3 A. By what factor does its stored magnetic energy increase?
  1. 3 times
  2. 9 times
  3. 2 times
  4. 6 times
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

An ignition primary is switched off, inducing a large secondary pulse. A technician says that the secondary voltage is simply the battery voltage passed through the windings. What mechanism actually produces the pulse?
  1. Steady primary flux induces a continuing secondary voltage
  2. Secondary turns produce a pulse even if primary flux stays constant
  3. Collapsing primary flux induces emf in the many-turn secondary
  4. Changing primary flux produces the same emf regardless of secondary turns
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

84 Key Terms, each with its definition

A

Active conductor length
The active conductor length is the portion of a wire within the magnetic field that contributes to its force calculation.
For a 2 m cable with 0.1 m in the field, the BIl calculation uses 0.1 m.
Air gap
An air gap is a non-magnetic separation in a magnetic circuit that raises reluctance and strongly affects flux and pull.
The closing gap between armature and core makes a relay’s magnetic pull stronger as it seats.
Alternator
An alternator is an AC generator in which relative rotation between a magnetic field and windings produces alternating emf.
A simple one-pole-pair alternator at 3,000 r/min produces one cycle per revolution and a 50 Hz output.
Armature
An armature is the movable magnetic part that operates a relay’s contacts.
The return spring pulls the armature away after the coil’s magnetic attraction has fallen sufficiently.
Auxiliary contact
An auxiliary contact performs a contactor’s control duties, such as holding or interlocking.
The NO pair 13–14 can maintain the coil’s current path after the START button is released.

B

Back emf
Back emf is the self-induced voltage that opposes a coil’s current change, slowing its rise or supporting it during decay.
Switching off reverses the coil’s voltage polarity so its current can continue briefly in the original direction.
Busbar
A busbar is a substantial conductor used to distribute power, requiring support against magnetic forces as well as heating.
Closely spaced busbars need bracing because fault currents can bend bars or pull their fixings loose.

C

Changeover contact
A changeover contact connects a common terminal to the NC path at rest and to the NO path when the relay operates.
A vehicle relay transfers terminal 30 from 87a to 87 when its coil attracts the armature.
Choke
A choke is an inductive component used to oppose changes in current.
An older lamp choke supplies a starting pulse when the starter opens and limits current during AC operation.
Coercivity
Coercivity measures resistance to demagnetization through the opposing magnetic field needed to remove magnetization.
A soft relay core has low coercivity so its magnetization can change easily during switching.
Coil rating
A coil rating specifies the control supply a winding requires, including its voltage and whether it is designed for AC or DC.
A 24 V DC controller needs a suitable DC coil even if an available AC coil also carries a 24 V label.
Commutator
A commutator is a segmented rotating connection that reverses a coil’s electrical connections each half turn in a simple DC machine.
In a simple DC motor, reversing coil current as the sides swap keeps torque in the same rotational sense.
Contact rating
A contact rating specifies allowable switching conditions, including voltage, current, AC/DC and the type of load.
A relay selected for a heater must be checked again if the replacement load is an inductive motor.
Contact resistance
Contact resistance is the electrical resistance of a closed contact path, assessed at specified current and test conditions.
A voltage-drop measurement at known load current helps reveal a contact that is heating excessively.
Contactor
A contactor is a heavy-duty relay designed to switch power loads repeatedly, with main poles and auxiliary control contacts.
A three-pole contactor switches all three supply paths to a motor from one control coil.
Conventional current
Conventional current is the agreed current direction from positive to negative through the external circuit, used in direction rules.
A technician uses conventional current consistently when applying grip and Fleming direction rules.

D

Degaussing
Degaussing removes magnetism with a gradually reduced alternating field.
A degaussing cycle leaves little overall domain alignment in a tool that has picked up unwanted magnetism.
Drop-out voltage
The drop-out voltage is the lower coil-voltage level at which an energized relay releases under its specified conditions.
A relay can remain held below its pull-in voltage because its release threshold is lower.

E

Eddy current
An eddy current is an induced current circulating within a metal part when the flux through that part changes.
An induction cooktop uses induced currents to heat suitable cookware while laminated cores reduce unwanted loops.
Electromagnet
An electromagnet uses current in a coil and a suitable core to produce a controllable working magnetic field.
Reversing a DC coil’s current swaps its magnetic poles while leaving the physical core in place.
Electromagnetic induction
Electromagnetic induction is the production of emf by changing magnetic flux linked with a conductor or coil.
Moving a magnet into an open coil can produce voltage even though the open circuit prevents current.
End-on current symbol
An end-on current symbol marks wire current perpendicular to a drawing: a dot comes out of the page and a cross goes into it.
A cross beside a wire section lets a learner apply the grip rule without a side-view drawing.

F

Faraday’s law
Faraday’s law relates induced emf to the rate of change of flux linkage, increasing emf for a faster change.
Moving the same magnet through a coil more quickly produces a larger induced voltage pulse.
Fault-current force
A fault-current force is the large magnetic mechanical load produced when conductors carry currents far above normal levels.
When both parallel currents rise tenfold, their mutual force rises one hundredfold at fixed geometry.
Ferromagnetic material
A ferromagnetic material can be strongly magnetized as many of its magnetic domains align in an applied field.
Iron, nickel, cobalt and many of their alloys show the strong magnetic response useful in equipment.
Field line
A field line follows the direction a small compass’s north end points.
Arrows outside a bar magnet run from its N pole toward its S pole, continuing as loops inside the magnet.
Fleming’s left-hand rule
Fleming’s left-hand rule gives force direction from field and conventional current using three mutually perpendicular fingers.
With field rightward and current into the page, the left thumb points down the page.
Fleming’s right-hand rule
Fleming’s right-hand rule gives induced-current direction from conductor motion and field using three perpendicular fingers.
With motion up the page and field rightward, the right-hand rule gives current into the page.
Flux density
Flux density is flux per perpendicular square meter, measured in teslas.
Two cores carrying the same flux have different flux densities if their cross-sectional areas differ.
Flux linkage
Flux linkage is the total linked magnetic flux across a coil’s turns, equal to NΦ when every turn links the same flux.
A larger turn count gives more flux-linkage change for the same change of flux through each turn.
Flyback diode
A flyback diode is a reverse-biased diode across a DC coil that conducts the continuing coil current after switch-off.
Connecting its cathode to coil positive lets it block normally and conduct when coil polarity reverses.

H

Henry
A henry is the inductance that induces 1 V for a current change of 1 A per second.
A 0.5 H coil undergoing a 2 A/s change develops an induced-emf magnitude of 1 V.
Hysteresis loss
Hysteresis loss is energy converted to heat as a material’s magnetization is repeatedly reversed by an alternating field.
Soft magnetic steel reduces reversal loss in an AC core compared with a hard permanent-magnet material.

I

Ignition coil
An ignition coil uses interrupted primary current and shared changing flux to produce a high pulse in a many-turn secondary.
The secondary pulse crosses a spark-plug gap after primary current is rapidly interrupted.
Inductance
Inductance L measures a coil’s flux linkage per ampere and determines induced emf for a given rate of current change.
Increasing turns on the same core can greatly increase the voltage produced by a rapid current change.
Inductive proximity sensor
An inductive proximity sensor detects nearby metal by the way induced currents in it alter the field of the sensor’s coil.
A metal part approaching a machine sensor changes its coil behavior without touching a switch.
Inductive voltage spike
An inductive voltage spike is a brief high voltage caused by rapid current change as an energized inductive circuit opens.
A low-voltage relay coil can damage a transistor at switch-off if its released energy has no controlled path.
Inrush current
Inrush current is the high initial current an AC electromagnet draws while its armature is open and inductance is low.
An AC contactor that cannot seat may keep drawing inrush current until its winding overheats.
Interlock
An interlock blocks incompatible operations, such as two opposing contactors closing together, by electrical or mechanical means.
An NC auxiliary contact of the forward contactor interrupts the reverse contactor’s coil circuit.

L

Laminated core
A laminated core consists of thin magnetic sheets insulated from each other to reduce unwanted eddy-current heating.
An AC contactor uses a laminated core where a steady-DC electromagnet may use a solid core.
Lenz’s law
Lenz’s law states that induced current produces a magnetic effect opposing the change that causes the induction.
A coil attracts a withdrawing magnet to oppose its departure, so opposition does not always mean repulsion.

M

Magnetic domain
A magnetic domain is a small region of aligned magnetization within a material.
Magnetizing a steel bar makes many domains contribute in the same direction instead of canceling.
Magnetic field
A magnetic field is a region where magnets, magnetic materials and current-carrying conductors can experience magnetic forces.
A compass turns when it is moved near the field of a bar magnet, even without touching the magnet.
Magnetic field strength
Magnetic field strength H is magnetomotive force per meter of magnetic path.
The same ampere-turns give a greater H along a shorter otherwise comparable magnetic path.
Magnetic flux
Magnetic flux is the total magnetic field passing through an area, measured in webers.
A wider pole face carries more flux at the same uniform perpendicular flux density.
Magnetic pole
A magnetic pole is a north or south region where a magnet’s effect is strongest.
Bringing two north poles together produces repulsion; turning one magnet around produces attraction.
Magnetic screening
Magnetic screening redirects flux around a protected space through a suitable soft magnetic material or special alloy.
An iron enclosure can guide a steady field around an instrument; a plastic cover offers little screening.
Magnetic trip
A magnetic trip is a circuit breaker’s electromagnetic release that responds rapidly to sufficiently large fault current.
A short-circuit current produces much greater magnetic pull than the circuit’s normal operating current.
Magnetomotive force
Magnetomotive force is a coil’s magnetizing effort, equal to turns times current.
A 700-turn winding at 0.2 A supplies 140 At of magnetizing effort to its magnetic path.
Motor effect
The motor effect is the force on a current-carrying conductor across a magnetic field, converting electrical input into movement.
A wire crossing a permanent-magnet gap moves when current flows, with direction found by the left hand.
Motor starter
A motor starter combines a switching contactor with an overload relay.
A sustained motor overload opens the control path and makes the starter’s contactor release.
Moving-coil meter
A moving-coil meter balances magnetic torque on a current-carrying coil against a spring to indicate current with a pointer.
A greater steady coil current gives a larger balanced pointer deflection on the analog scale.
Mutual induction
Mutual induction occurs when changing current in one winding changes shared flux and induces emf in another winding.
Two windings on a shared iron core can transfer energy on AC without direct electrical contact.

N

Neutral point
A neutral point is a location where opposing magnetic fields cancel.
Identical magnets with like poles facing symmetrically have a neutral point midway between them.
No-volt protection
No-volt protection in a holding circuit prevents automatic restart after supply loss by opening the holding path when the coil drops out.
When power returns, the released START button leaves the machine off until another start command.
Normally closed contact
A normally closed contact conducts with its coil off and opens when the coil operates.
A relay’s NC output can feed an indicator when the coil is off, regardless of the machine’s usual state.
Normally open contact
A normally open contact is open with its coil off and closes when the coil operates.
Terminal 87 of a typical vehicle relay supplies the load after the coil is energized.

P

Perpendicular component
A perpendicular component is the part of a direction-dependent quantity across another direction, used in the sin θ force factor.
A wire at 30° to the field experiences half the force of the same wire placed perpendicular to it.
Pull-in voltage
The pull-in voltage is the coil voltage needed for a relay to operate from its released position under specified conditions.
A weak supply may keep a relay held yet fail to pull it in again after it has released.

R

RC snubber
An RC snubber is a series resistor-capacitor network that absorbs switching transients across a coil or contact.
A suitably rated RC module can suppress an AC contactor coil where a plain DC flyback diode is unsuitable.
Regenerative braking
Regenerative braking uses a mechanically driven electrical machine as a generator to recover some vehicle motion energy.
During braking, the wheels drive the machine and electrical energy can return toward the battery.
Relative permeability
Relative permeability compares a material’s magnetic response with free space at a given operating point, linking H to B.
An iron core can greatly increase flux density, while a copper core has relative permeability near 1.
Relay
A relay is an electrically operated switch in which a coil moves contacts that control a separate load circuit.
A small dashboard-switch current can operate contacts carrying the larger current of a vehicle fan.
Reluctance
Reluctance is the opposition a magnetic path offers to flux, with air offering much more opposition than suitable iron.
A small air gap can demand more magnetizing effort than a much longer section of iron core.
Remanence
Remanence is magnetism retained after the applied magnetizing field is removed.
A non-magnetic stop gap reduces the chance that residual attraction will hold a relay armature closed.
Right-hand grip rule
The right-hand grip rule finds the magnetic-field direction from conventional current, using curled fingers and thumb.
For a straight wire the thumb follows current; for a coil the fingers follow current around the turns.

S

Saturation
Saturation occurs when further magnetizing effort adds little flux density.
Extra coil current near core saturation may add much more heat than useful magnetic strength.
Self-holding circuit
A self-holding circuit keeps a contactor energized through its own NO auxiliary contact after a momentary START command.
Opening the series STOP button drops out the contactor and opens the holding contact.
Self-induction
Self-induction is emf induced in a winding by changes in its own current and magnetic flux, opposing those current changes.
At switch-on, an inductive branch’s current rises gradually while a comparable resistive branch responds quickly.
Shading ring
A shading ring is a conductive loop in part of an AC magnet’s pole face that creates delayed flux and reduces chatter.
The ring helps keep the armature attracted as the main flux passes through zero twice each cycle.
Slip ring
A slip ring is a continuous rotating electrical connection touched by a brush.
Two slip rings keep each end of the simple generator coil connected to its own brush.
Solenoid
A solenoid is a many-turn wire coil with an axial magnetic field.
Winding the same current path into turns makes the field inside the coil much stronger than outside.
Solenoid actuator
A solenoid actuator combines an energized coil and movable magnetic plunger to produce a short straight-line stroke.
A control signal pulls a valve plunger inward, and a spring returns it when coil current stops.
Solid-state relay
A solid-state relay switches using semiconductors instead of moving contacts and can produce heat or fail short-circuited.
A silent switching output still needs appropriate thermal design and a separate means of isolation.
Stored magnetic energy
Stored magnetic energy is energy held in a current-carrying coil’s field, calculated as one half of L times current squared.
A 0.5 H coil at 2 A stores 1 J that must be transferred elsewhere when the current stops.

T

Tesla
A tesla is one weber per square meter, the SI unit of flux density.
A uniform field of 1 T carries 0.001 Wb through a perpendicular area of 0.001 m².
Time constant
The time constant τ of a fixed inductive DC circuit is L/R, with current reaching about 63% of final after that time.
A 0.2 H, 10 Ω coil has a 20 ms time constant, independently of its separate V/R final-current calculation.
Torque
Torque is the turning effect of a force about a shaft or pivot.
Opposing forces on opposite coil sides can rotate the coil even though their net straight-line force cancels.

U

Uniform magnetic field
A uniform magnetic field has constant magnitude and direction throughout a region.
The narrow gap between suitable unlike pole faces can provide a nearly uniform field for a wire.
Utilization category
A utilization category states the kind of switching duty used to rate contacts, such as heater duty AC-1 or motor duty AC-3.
A contactor’s 25 A AC-1 figure cannot establish that it can start a 25 A motor.

V

Variable-reluctance sensor
A variable-reluctance sensor uses passing steel teeth to change a permanent magnet’s flux through a coil and induce voltage pulses.
A slowing toothed ring produces fewer pulses per second and smaller signals in a passive speed sensor.
Varistor
A varistor is a voltage-dependent resistor used to clamp a transient once voltage rises into its conducting region.
A rated varistor module limits a coil’s switch-off voltage while allowing faster decay than a low diode clamp.
Voice coil
A voice coil is a speaker winding whose magnetic force moves the attached cone.
Reversing audio current reverses magnetic force and sends the speaker cone back in the other direction.

W

Weber
A weber is the SI unit of magnetic flux, represented by Wb.
A measured flux of 0.002 Wb can be recorded as 2 mWb without changing the physical quantity.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started