Alternating Current Basics
IntermediateLesson 4 of 7 in Electrical Principles for Technicians Course
What you will learn
- Explain how a sine-wave voltage is produced, read its period and frequency, and convert between the peak, peak-to-peak, average and rms values that describe its size.
- Read a sine wave: cycle, period and frequencyDescribe how a rotating generator produces a sine wave, and use period, frequency and instantaneous values to read AC waveforms on paper and on an oscilloscope.
- Use peak, peak-to-peak, average and rms valuesConvert between the values that describe the size of a sine wave, explain what an rms value means, and know which value a meter shows and which value a component must withstand.
- Read a sine wave: cycle, period and frequency
- Describe the phase relationship between voltage and current in resistors, inductors and capacitors, and calculate inductive and capacitive reactance at any frequency.
- Describe phase difference and resistive circuitsDescribe lead and lag between two sine waves of the same frequency, draw simple phasor diagrams, and apply Ohm's law and the power formula to purely resistive AC circuits.
- Calculate inductive reactance and describe current lagExplain why an inductor opposes alternating current, calculate its reactance from frequency and inductance, and describe how its current lags the voltage.
- Calculate capacitive reactance and describe current leadExplain how a capacitor carries alternating current, calculate its reactance from frequency and capacitance, and describe how its current leads the voltage.
- Describe phase difference and resistive circuits
- Combine resistance and reactance into impedance in series and parallel circuits, and use right-triangle methods to find currents, voltages and phase angles and how they change with frequency.
- Analyze series RL and RC circuitsUse the impedance and voltage triangles to find impedance, current, component voltages and phase angle in series circuits with resistance and one kind of reactance.
- Analyze series RLC circuits and resonanceCombine inductive and capacitive reactance in one series circuit, decide whether it behaves inductively or capacitively, and describe series resonance.
- Analyze parallel AC circuitsFind branch currents, the total current and the phase angle when resistors, inductors, capacitors and real loads are connected in parallel across one supply.
- Analyze series RL and RC circuits
- Distinguish active, reactive and apparent power, explain what the power factor means for a load and for the supply, and size a capacitor that corrects a low power factor.
- Use the power triangle: active, reactive and apparent powerCalculate active, reactive and apparent power in single-phase circuits and relate them with the power triangle.
- Explain the power factor and its effectsDefine the power factor, recognize lagging and leading loads, measure the power factor, and explain why a low power factor costs current, losses and money.
- Correct a low power factor with capacitorsExplain how parallel capacitors improve a lagging power factor, calculate the capacitor's reactive power and capacitance, and describe practical correction methods and their hazards.
- Use the power triangle: active, reactive and apparent power
- Describe common single-phase and three-phase supply systems, convert between line and phase values in star and delta, calculate three-phase power, and explain why loads are balanced and how equipment uses a three-phase supply.
- Describe single-phase supply systemsIdentify the conductors and voltages of common single-phase supplies and calculate the current of single-phase loads.
- Relate line and phase values in star and deltaDescribe how three-phase voltages are produced and convert between line and phase voltages and currents in star (wye) and delta connections.
- Calculate three-phase power and balance the loadCalculate the power and line current of balanced three-phase loads, find the neutral current of unbalanced loads, and explain why loads are spread evenly over the phases.
- Explain how equipment uses a three-phase supplyDescribe how three-phase currents create a rotating magnetic field, connect a motor in star or delta from its nameplate, and recognize three-phase AC in buildings, vehicles and aircraft.
- Describe single-phase supply systems
Alternating Current study guide
1Read and measure an AC waveform
An AC waveform tells you both how quickly a supply changes and how large its voltage becomes. Reading its time scale leads to frequency; reading its vertical scale leads to peak and rms values. These measurements answer different equipment questions: the heating a load produces, the voltage its insulation must withstand, and the frequency its magnetic parts will experience. A sine wave gives a clear starting point for all three.
1.1 Cycles, time and frequency
An alternating voltage reverses polarity, and an alternating current reverses direction. A sine wave rises smoothly to a positive peak, falls through zero to a negative peak, and returns to its starting point. That complete pattern is one cycle.
From rotation to a waveform
A coil turning at constant speed in a uniform magnetic field has an induced voltage that follows the sine of its angle. In a simple two-pole generator, one turn gives one cycle. One cycle contains 360 electrical degrees. Starting at an upward zero crossing, the positive peak is at 90°, the next zero crossing at 180°, and the negative peak at 270°.
The period, , is the time for one cycle. The frequency, , counts cycles per second in hertz (Hz):
Convert milliseconds to seconds before taking the reciprocal. At 50 Hz, the period is 0.020 s, or 20 ms. At 60 Hz it is about 16.7 ms; at 400 Hz it is 2.5 ms. A faster repetition shortens the wave horizontally. It does not make the peak taller.
Read the scales
On an oscilloscope, the horizontal scale is time per division. If a full cycle covers four divisions at 5 ms/div, its period is . Convert to 0.020 s and calculate . Count between matching points, such as two successive upward zero crossings. Adjacent zero crossings are only half a cycle apart.
The vertical scale is volts per division. A trace extending 6.5 divisions from its lowest to highest point at 100 V/div spans 650 V peak to peak. Its peak measured from the zero line is 325 V.
Measurement safety: A standard bench oscilloscope's probe ground is connected to protective earth. Never clip it to a line conductor or disconnect the oscilloscope's protective earth. Use a correctly rated differential probe, rated isolated inputs, or a reduced-voltage transformer copy of the waveform for this measurement.
Find a value at one moment
The instantaneous voltage depends on position within the cycle:
Measure time from an upward zero crossing and use degree mode. For a 325 V peak at 50 Hz, 2.5 ms corresponds to . The voltage is therefore . This is one moment's value; it is not a new peak or a new supply rating.
Match frequency to the source
Generator speed and pole count set the frequency:
Here is the number of pole pairs and is speed in rpm. Two poles mean one pair: 3000 rpm gives 50 Hz. Four poles mean two pairs, so 1500 rpm gives the same 50 Hz. Counting poles as pairs would double the answer.
Many grids operate at 50 Hz; North American grids generally use 60 Hz. Japan uses 50 Hz in the east and 60 Hz in the west. Aircraft commonly use 400 Hz, which allows smaller magnetic equipment. The source frequency is an equipment characteristic to check alongside voltage.
Key Takeaways
- A full cycle runs between matching points on successive repetitions.
- Use seconds in ; 20 ms is 0.020 s.
- Amplitude and frequency describe different features of a wave.
- Generator frequency depends on speed and the number of pole pairs.
- Instantaneous voltage follows from an upward zero crossing.
1.2 Peak voltage and effective voltage
An AC voltage has several useful size measurements. The right one depends on whether you are reading a trace, calculating heating, or checking a component's voltage stress. Supply voltage and current ratings normally use rms values.
Choose the measurement
| Value | What it measures | Symmetrical sine wave |
|---|---|---|
| Peak | Zero to the highest positive value | |
| Peak to peak | Negative peak to positive peak | |
| Full-cycle average | Signed average over a complete cycle | Zero |
| Half-cycle average | Average over the positive half cycle | |
| rms | Equivalent DC heating value |
Root-mean-square means the DC voltage that would produce the same average heating in the same resistor. The positive and negative halves both heat the resistor: reversing both voltage and current keeps their product positive. A full-cycle average of zero therefore does not mean zero heating.
For a sine wave:
The same relationships apply to sinusoidal current. Peak is larger than rms. Use that size check to catch a reversed conversion.
Work from a supply rating
A 230 V supply is 230 V rms. Its peak is and its peak-to-peak value is about 650 V. The half-cycle average is . A 120 V rms sine wave reaches about 170 V peak; a 115 V aircraft supply reaches about 163 V.
For a 52.9 Ω heater on 230 V rms:
Its peak current is about . The heater produces the same average heat as it would on 230 V DC. Use rms current for the heating of conductors and fuses. Insulation and electronic components also have to withstand waveform peaks, supply variation and surges; a 230 V rms label does not limit instantaneous voltage to 230 V.
Understand the meter
An average-responding AC meter measures the rectified average and scales it by about 1.11 to display rms for a sine wave. That conversion is built around the sine-wave shape. Currents drawn by LED drivers, switch-mode supplies and variable-speed drives can be distorted, so they need a true-rms meter with suitable ratings and bandwidth.
A true-rms instrument determines the heating-related value without assuming a sine-wave shape. Do not apply the sine-wave peak factor to every waveform: a symmetrical square wave has rms equal to its peak magnitude. A meter's AC reading also does not replace a waveform display when you need the actual shape or peak.
The half-cycle average is useful when examining rectification. It describes the average of the rectified sine wave, while rms describes heating. Keeping those purposes separate prevents a rectifier average from being substituted into an AC power calculation.
Key Takeaways
- rms gives the DC-equivalent heating effect in a resistor.
- For a sine wave, peak is rms multiplied by .
- Peak to peak is twice the peak for a wave symmetrical about zero.
- A zero signed average does not imply zero power.
- Average-responding meters rely on a sine-wave calibration.
- Use true-rms measurement for distorted waveforms within the instrument’s ratings.
2Predict current in resistors, coils and capacitors
A resistor turns electrical energy into heat. A coil stores energy in a magnetic field, while a capacitor stores it in an electric field. These different actions explain why voltage and current can reach their peaks at different times. You will describe that timing as lead or lag, calculate the opposition called reactance, and predict how a change in frequency affects a component before combining components into a circuit.
2.1 Phase difference and resistive loads
Two sine waves can have the same frequency and still reach their peaks at different times. Their phase difference expresses that timing shift as part of a cycle. The wave reaching a matching point first leads; the later wave lags.
Turn a time shift into an angle
One complete period represents 360°. The relationship is:
At 50 Hz, one period is 20 ms. A current lag of 30° corresponds to . At 60 Hz, the same angle corresponds to about 1.39 ms because the whole cycle is shorter. Compare waves of the same frequency when describing a fixed phase difference.
An oscilloscope trace gives the direction of the shift as well as its size. If the voltage's positive peak appears before the current's positive peak, voltage leads and current lags. Saying only “30°” leaves out which quantity comes first.
Draw a phase relationship
A phasor is an arrow representing a sinusoidal quantity. Its length shows size, usually rms, and its angle shows phase. Imagine the arrows rotating counterclockwise together. An arrow further counterclockwise leads.
Choose a shared reference. In a series circuit, the same current passes through every component, so draw current along the horizontal zero-degree line. In a parallel circuit, all branches share voltage, so voltage is the reference. These drawings let you compare timing without drawing complete waves.
Arrows along the same direction add by ordinary arithmetic. Arrows at right angles form a right triangle: their resultant length follows the Pythagorean theorem. An arrow's length is a magnitude; its angle is essential when combining it with another quantity.
Calculate a heater's current and power
For a pure resistor, current and voltage are in phase. They pass through zero together and have their positive and negative peaks together. With rms values, Ohm's law applies:
A 46 Ω heater on 230 V takes . Its average power is . Series resistor voltages add normally, and parallel resistor currents add normally, because the quantities being added are in phase.
Instantaneous power is . During the negative half cycle, both voltage and current are negative, so their product is positive. Resistor power pulses from zero to at twice the supply frequency. This heater's instantaneous power reaches 2300 W, while its average remains 1150 W.
Know when DC addition stops working
The resistance of ordinary heaters and wiring at 50 or 60 Hz is practically the DC value. At higher frequencies, skin effect pushes current toward a conductor's surface and raises its effective resistance; thick conductors can show this at 400 Hz.
Inductors and capacitors introduce phase shifts. Their out-of-phase voltage or current magnitudes cannot simply be added as if they peaked together. Two quantities that really are in phase still add arithmetically, even in an AC circuit.
Key Takeaways
- Lead and lag say which same-frequency wave reaches a matching point first.
- Phase angle is the time shift expressed as a fraction of 360°.
- A pure resistor has current and voltage in phase.
- Use the shared current as the series reference and shared voltage as the parallel reference.
- Combine out-of-phase quantities with their directions as well as their magnitudes.
2.2 Coils and inductive reactance
A coil resists a change in current. As its current changes, so does its magnetic field. That changing field induces a voltage opposing the change. In an AC circuit this action produces inductive reactance, measured in ohms.
Calculate the opposition
Inductive reactance is:
Use frequency in hertz and inductance in henries. A 100 mH coil has . At 50 Hz:
At 60 Hz the same coil has about 37.7 Ω reactance, and at 400 Hz about 251 Ω. Doubling frequency doubles reactance. Increasing inductance also increases reactance.
For an ideal coil, . On 230 V at 50 Hz, the 0.1 H coil carries about . At 400 Hz on the same voltage it carries about 0.915 A. Voltage is unchanged; the faster change in current makes the inductive opposition larger.
Explain the lag
In an ideal inductor, current lags voltage by 90°, or one quarter cycle. At 50 Hz that is 5 ms. The voltage is greatest when the current is changing fastest, not when the current has reached its peak. At a current peak the slope is zero, so the ideal inductor's voltage is zero.
The memory aid ELI places voltage E before current I around inductance L. The useful meaning is “voltage leads current in an inductor.” Real motor and transformer windings also have resistance and losses. Their current usually lags by less than 90°.
Distinguish reactance from resistance
An ohmmeter uses DC and reports winding resistance. It does not report the coil's AC reactance. A coil reading 12 Ω on an ohmmeter may have AC impedance above 100 Ω. From AC voltage and current you obtain total impedance magnitude:
For a series resistance-inductance model, use the known resistance to separate the inductive part:
At steady DC, frequency is zero and inductive reactance is zero. Current is then limited by winding resistance. An AC contactor coil with 15 Ω resistance connected to 230 V DC would draw about 15.3 A once steady, even if its normal AC current were only about 0.2 A. The AC and DC voltage ratings of a coil are therefore not interchangeable.
Follow the stored energy
An ideal inductor stores energy in its magnetic field and gives it back. Its average power is zero, although current flows. A real coil heats because winding resistance and core losses convert some input energy into heat.
Adding turns or using an iron core generally increases inductance. Coils appear in relays, contactors, motors, transformers and chokes. A choke offers relatively little opposition to steady DC and stronger opposition to high-frequency AC. That frequency dependence helps filters reduce electrical interference.
Key Takeaways
- An inductor opposes changes in current through self-induction.
- Calculate using henries.
- Ideal inductive current lags voltage by 90°.
- An ohmmeter measures winding resistance, not AC reactance.
- An ideal inductor returns stored energy; real coils also have losses.
- At steady DC the coil’s winding resistance limits current.
2.3 Capacitors and capacitive reactance
A capacitor has two conductors separated by an insulating dielectric. Changing the voltage moves charge onto one plate and off the other. Repeated charging and discharging produces alternating current in the connecting circuit without charge crossing the ideal dielectric.
Use farads in the calculation
Capacitance measures how much charge is stored for a given voltage. Its unit is the farad (F), but practical values commonly use microfarads, nanofarads or picofarads. One microfarad is ; one millifarad is . Confusing the two changes a calculation by a factor of 1000.
Capacitive reactance is:
For 10 µF at 50 Hz, enter :
On 230 V the ideal capacitor current is . At 60 Hz its reactance is about 265 Ω, and at 400 Hz about 39.8 Ω. Frequency and capacitance are in the denominator: doubling either one halves the reactance. At fixed voltage, that doubles the current.
Explain why current leads
In an ideal capacitor, current leads voltage by 90°. Current is greatest at a voltage zero crossing because the voltage is changing fastest there. At the voltage peak the change momentarily stops and the current is zero.
The memory aid ICE puts current I before voltage E around capacitance C. An ideal capacitor stores energy in an electric field and returns it each quarter cycle. Its average power is zero. Its leading current can oppose the lagging current of an inductive load at the supply connection.
| Component | Effect of raising frequency | Ideal current timing |
|---|---|---|
| Inductor | Reactance increases | 90° behind voltage |
| Capacitor | Reactance decreases | 90° ahead of voltage |
Apply its frequency behavior
After a capacitor finishes charging from DC, no steady current flows through the ideal capacitor. As frequency approaches zero, capacitive reactance grows very large. Higher-frequency AC passes more easily. In a loudspeaker crossover, a capacitor in series with a tweeter holds back low frequencies. A series inductor does the opposite for a woofer.
Larger plate area increases capacitance; greater plate spacing reduces it. A dielectric with higher permittivity also increases capacitance. In a capacitive aircraft fuel probe, rising fuel replaces air between the conductors. The change in dielectric changes capacitance, which the gauging system measures.
Respect stored charge and voltage ratings
A capacitor can retain a dangerous charge after disconnection. Follow the equipment's discharge instructions, wait the specified time and verify zero voltage before touching its terminals. Do not assume that a discharge resistor is fitted or that it has worked.
A capacitor's rating must match its duty as well as the voltage across it. Motor-run capacitors used with a 230 V supply commonly carry an AC rating such as 400 V or 450 V. A voltage value without its AC or DC duty is not enough to identify a suitable replacement.
Key Takeaways
- Capacitor current comes from charging and discharging as voltage changes.
- Use with capacitance in farads.
- Increasing frequency or capacitance lowers capacitive reactance.
- Ideal capacitive current leads voltage by 90°.
- A charged ideal capacitor blocks steady DC.
- Capacitance depends on plate area, spacing and dielectric.
- Stored charge can remain after the supply is removed.
3Solve mixed AC circuits with triangles
Mixed circuits need both size and timing. In series circuits you combine component voltages; in parallel circuits you combine branch currents. Right triangles give the total when resistive and reactive parts are 90° apart. You will use that method to calculate impedance and phase angle, then examine what happens when inductive and capacitive effects cancel at resonance. Component readings can exceed a supply reading without breaking the circuit laws.
3.1 Impedance in series RL and RC circuits
The same current passes through every part of a series circuit. A resistor's voltage is in phase with that current. An ideal inductor's voltage is 90° ahead of it; an ideal capacitor's voltage is 90° behind it. The supply voltage combines these timed contributions.
Build the impedance triangle
For series resistance and one kind of reactance:
Impedance magnitude is the total AC opposition in ohms. Draw resistance horizontally, reactance vertically, and impedance as the hypotenuse. The triangle also gives:
Use the magnitude of reactance for the angle size and state lead or lag from the component. An RL circuit gives lagging current; an RC circuit gives leading current. In a signed drawing inductive reactance points up and capacitive reactance points down.
Work an RL circuit
Connect 30 Ω resistance and 40 Ω inductive reactance in series on 230 V:
- Impedance: .
- Current: .
- Resistor voltage: .
- Inductor voltage: .
- Phase angle: , current lagging.
The power factor is . Check the supply with . Adding the readings as 138 + 184 would give 322 V, but those two voltages reach their peaks at different times. Likewise, adding 30 + 40 is not the impedance calculation.
Work an RC circuit
For 120 Ω resistance and 50 Ω capacitive reactance on 230 V:
Current is . Keeping the unrounded current gives about 212 V across the resistor and 88.5 V across the capacitor. The phase angle is leading, with power factor . The impedance triangle has the same length rules as RL, but the current timing reverses.
Learn about a real coil from measurements
A coil has 12 Ω DC resistance and draws 2.0 A at 230 V, 50 Hz. First find . For its series RL model:
Voltage divided by current gives impedance, not reactance alone.
Frequency changes the triangle. With 30 Ω and 0.1 H on 230 V, raising frequency from 50 to 400 Hz raises reactance from about 31.4 to 251 Ω. Impedance rises from about 43.4 to 253 Ω and current falls from about 5.29 to 0.909 A. A series RC circuit responds in the opposite direction: increasing frequency lowers its capacitive reactance and increases its current toward the resistance-limited value.
Key Takeaways
- Find series impedance with a right triangle, not .
- Calculate the common current before component voltage drops.
- Component voltages combine according to their phase relationships.
- RL current lags; RC current leads.
- AC voltage and current measurements give impedance magnitude.
- Frequency changes reactance, impedance and phase angle.
3.2 Series RLC circuits and resonance
A series RLC circuit contains resistance, inductance and capacitance in the same current path. The inductor and capacitor voltages point in opposite directions on the voltage diagram. Their effects subtract before the reactive part combines with resistance.
Find the net reactance first
Use:
If inductive reactance is larger, current lags. If capacitive reactance is larger, current leads. Equal reactances cancel at the supply, giving zero net phase angle. The resistor voltage remains in phase with current in each case.
For 40 Ω resistance, 100 Ω inductive reactance and 70 Ω capacitive reactance on 230 V:
- Net reactance: , inductive.
- Impedance: .
- Current: .
- Angle: lagging.
The power factor is . Adding the two reactances would miss their opposite phase directions and greatly overstate impedance.
Check each component voltage
The common current gives , and . A 460 V component reading on a 230 V supply can be correct. The reactive voltages oppose each other, leaving . The supply is:
Each component must withstand the voltage across itself.
Find the resonant frequency
Series resonance occurs when . Solving the two reactance formulas gives:
Use henries and farads. With 0.1 H and 10 µF, the product is . Its square root is 0.001, so .
At resonance, and . For fixed supply voltage and resistance this is the largest current. Supply current is in phase with supply voltage and the power factor is 1. The inductor and capacitor can each have a large voltage, even though their combined voltage is zero.
Predict which side of resonance you are on
As frequency rises, inductive reactance rises and capacitive reactance falls. Below resonance, capacitive reactance wins and current leads. Above resonance, inductive reactance wins and current lags. At 50 Hz the 0.1 H and 10 µF combination has about 31.4 Ω inductive reactance and 318 Ω capacitive reactance, so it is capacitive.
Tuned circuits and filters use resonance to select a frequency. Accidental resonance between network inductance and capacitors can also magnify currents and voltages.
Key Takeaways
- Subtract from before combining reactance with resistance.
- The larger reactance determines whether current leads or lags.
- Component voltages can exceed supply voltage.
- At series resonance, impedance is minimum and current is maximum for fixed voltage and resistance.
- Below resonance the circuit is capacitive; above it the circuit is inductive.
3.3 Current in parallel AC branches
Every parallel branch has the same supply voltage. Use that voltage as the phase reference and find the branch currents first. The branch current readings may add to much more than the supply current because they reach their peaks at different times.
Separate current by timing
For ideal resistor, inductor and capacitor branches:
The resistor current is in phase with voltage. Inductor current lags by 90°; capacitor current leads by 90°. Their reactive currents oppose, leaving a net reactive magnitude based on . Combine it with the resistive current:
A positive inductive remainder means lagging supply current. A capacitive remainder means leading supply current. The power factor for these sinusoidal currents is .
Work three branches
On 230 V, a 46 Ω resistor takes 5 A, a 23 Ω inductive reactance takes 10 A, and a 46 Ω capacitive reactance takes 5 A. The net reactive current is lagging. Thus:
The phase angle is 45° lagging and power factor is about 0.707. A supply clamp meter reads about 7.07 A, not the arithmetic total of 20 A. The opposing reactive currents partly circulate between branches.
With the capacitor removed, the resistor and inductor still take 5 A and 10 A. Supply current becomes . Adding the capacitor reduced supply current while leaving both original branch currents unchanged at the same voltage.
Combine a real load with a heater
A motor draws 10 A at power factor 0.8 lagging. Its in-phase part is . Its reactive part is lagging. A parallel heater adds 5 A in phase, giving 13 A in phase and 6 A reactive:
The combined power factor is about lagging. Adding the motor and heater magnitudes as 15 A would treat their currents as if they had the same timing.
Recognize parallel resonance
When ideal inductive and capacitive branch currents are equal, they cancel at the supply. The supply then carries only the resistor current, in phase with voltage. In a parallel ideal LC pair, the net reactive supply current is zero at resonance, even though nonzero currents flow in its branches. Real losses require some supply current.
The series impedance formula does not apply directly to separate parallel branches. A 46 Ω resistor in parallel with 23 Ω inductive reactance on 230 V has currents of 5 A and 10 A, total about 11.2 A, and impedance about 20.6 Ω. Calculate branch currents before drawing the current triangle.
Key Takeaways
- Parallel branches share voltage; calculate their currents separately.
- Inductive and capacitive branch currents subtract.
- In-phase and net reactive currents combine at right angles.
- Split a real load current into in-phase and reactive components before combining loads.
- Parallel cancellation can leave substantial current inside the branches.
- Adding a parallel capacitor can lower supply current without lowering motor current.
4Calculate power and reduce supply current
An AC load can draw current both to convert energy and to exchange stored energy with the supply. Active, reactive and apparent power describe those different demands. Their triangle explains power factor and why a motor can burden a supply more than its wattage suggests. You will calculate the three quantities, use measurements to judge power factor, and find how much parallel capacitance is needed to reduce a lagging reactive demand.
4.1 Watts, var and volt-amperes
A heater and a motor drawing the same current at the same voltage need not convert energy at the same rate. The motor's phase shift changes the average of voltage times current. Three power quantities separate energy conversion from current demand.
Name the three quantities
| Quantity | Meaning | Sinusoidal single-phase formula |
|---|---|---|
| Active power, W | Average energy conversion into heat, light or work | |
| Reactive power, var | Energy exchange with magnetic or electric fields | |
| Apparent power, VA | Product of rms voltage and rms current |
Use rms voltage and current throughout. Energy meters record active energy in kilowatt-hours. A kilowatt-hour is energy, whereas a kilowatt is power. Transformers and generators have kVA ratings because their voltage and current burdens matter even when the load's power factor is low.
Reactive power describes a repeated exchange. An ideal inductor stores energy in its magnetic field; an ideal capacitor stores energy in its electric field. Each returns stored energy to the circuit, so its average active power is zero. The current carrying that exchange still heats resistance in real supply cables.
Build the power triangle
For sinusoidal voltage and current, draw active power horizontally and reactive power vertically. Apparent power is the hypotenuse:
Inductive reactive power is taken as positive and capacitive reactive power as negative. For combined loads, active powers add, while inductive and capacitive reactive powers oppose: . Calculate apparent power from the resulting totals, not by adding separate apparent powers blindly.
Work a motor's input power
A motor takes 10 A from 230 V at power factor 0.8 lagging. First calculate . Then:
Since :
The check is . Multiplying voltage by current alone gives apparent power, not this motor's active input. Shaft output would also require the motor's efficiency.
Connect power to circuit components
In a series circuit, the resistance converts active power and reactance accounts for reactive power:
With 30 Ω resistance, 40 Ω inductive reactance and 4.6 A, active power is about 635 W and reactive power about 846 var. Apparent power is . Multiplying every side of the impedance triangle by current squared produces the power triangle.
Instantaneous power is . It becomes negative during parts of a cycle when voltage and current have opposite signs: energy then returns toward the supply. A real inductive load still has positive average active power. Do not describe its entire input as lost heat simply because some of its current is reactive.
Key Takeaways
- Active power measures average energy conversion in watts.
- Reactive power describes energy exchange and is measured in var.
- Apparent power is rms voltage times rms current, in VA.
- For sinusoidal quantities, .
- Add active powers and signed reactive powers before finding total apparent power.
- Electrical motor input and shaft output are different power measurements.
4.2 Power factor and supply losses
Power factor tells you how much active power a load takes for its apparent power. A low value means more supply current for the same active power and voltage. That matters to cables and transformers even when the load is doing exactly the same useful work.
Define it before calculating an angle
For a consuming load, power factor lies between 0 and 1. With sinusoidal voltage and current it is . Describe inductive loads as lagging and capacitive loads as leading; the number alone does not identify that timing.
Resistive heaters have power factor close to 1. Induction motors and transformers draw lagging magnetizing current. An induction motor may have power factor around 0.85 under full load but below 0.5 unloaded. Its active demand falls with mechanical load while its magnetic field still needs current.
Power factor is different from efficiency. Efficiency compares useful output with active input. Power factor compares active input with apparent input. A low-power-factor motor is not converting all of its reactive power into waste heat.
Calculate the current penalty
For a sinusoidal single-phase load:
A 10 kW load on 230 V takes about 43.5 A at power factor 1. At 0.7 it takes about 62.1 A. The same active power now needs times the current.
Cable heating follows . With the same cable resistance, the loss ratio is:
That is about twice the cable loss, not 43% more. Increased current also raises voltage drop and occupies more of a transformer's current capacity. Some commercial and industrial tariffs charge for reactive energy or low power factor, but the electrical current penalty exists regardless of the billing arrangement.
Use measured watts and rms values
A load on 230 V takes 5.2 A and a wattmeter reads 850 W:
For sinusoidal current, the angle is . Wattage and current magnitude alone do not tell you whether that angle is leading or lagging; phase measurement or knowledge of the load supplies the direction.
Recognize distorted current
Rectifiers, LED drivers and variable-speed drives may draw current in pulses. True power factor remains , but the cosine of the angle between fundamental-frequency voltage and current is only the displacement power factor. With a sinusoidal supply, current distortion can reduce true power factor even when the fundamental current is nearly in phase.
Use a true-rms power analyzer to assess such a load. A capacitor addresses lagging reactive current; it does not remove the distortion by itself. Applying to a distorted waveform as if it described one simple time shift would hide the cause of the extra current.
Key Takeaways
- Power factor is active power divided by apparent power.
- With sinusoidal voltage and current, power factor equals .
- Lower power factor needs more current at fixed active power and voltage.
- Supply conductor losses increase with current squared.
- Power factor and efficiency compare different quantities.
- Distorted current requires true-power-factor measurement.
4.3 Parallel capacitors for power-factor correction
An inductive load needs lagging reactive current. A capacitor connected in parallel supplies leading reactive current at the same location. Those reactive contributions partly cancel at the supply, lowering the current in upstream cables.
Keep the motor and supply separate
At fixed voltage and mechanical load, correction does not change the motor's own current, active power or reactive demand. It changes what the supply must provide to the motor-capacitor combination. The motor's active power continues to come from the supply; some of the reactive exchange now occurs locally.
The correction calculation uses the power triangle before and after compensation:
The existing power factor determines , and the target determines . Use active electrical input power for . Keep watts with var, or kilowatts with kvar.
Calculate the required reactive power
Correct a 10 kW, 230 V, 50 Hz load from 0.7 to 0.95 lagging. The angle calculations give:
The original reactive demand is about 10.2 kvar and the desired remainder is about 3.29 kvar. Subtracting with unrounded values gives:
The capacitor therefore supplies about 6.92 kvar. Using the entire original 10.2 kvar would target unity power factor instead of the specified 0.95.
Convert var into capacitance
For a single-phase capacitor across rms voltage :
Using unrounded reactive power:
The original supply current was about 62.1 A. After correction it is . Active power stays at 10 kW in this calculation; lower upstream losses are a separate benefit.
Choose correction to follow the load
Individual correction switches a capacitor with one motor. Group correction serves several loads together. Central correction uses a controller to switch capacitor-bank steps as the total demand changes. Three-phase loads use appropriately connected three-phase banks.
Targets around 0.95 leave room for load changes. If too much capacitance remains connected at light load, the supply becomes leading and current can rise again. Moving from 0.95 to exactly 1 saves relatively little current and requires closer control.
Distorted currents introduce another concern: capacitors can resonate with supply inductance and amplify harmonic current. Detuned banks include series reactors to manage that risk. The simple sizing formula describes the reactive requirement; suitable equipment also depends on voltage duty, switching conditions and distortion.
Key Takeaways
- Connect correction capacitors in parallel with an inductive load.
- Calculate the required reduction in reactive power from both power-factor angles.
- For a single-phase capacitor, .
- Correction lowers upstream current without changing the motor’s active power at fixed conditions.
- Excess capacitance can produce a leading power factor.
- Automatic steps follow changing demand; detuned banks address resonance risk.
5Use single-phase and three-phase supply values
Supply labels describe voltages between particular conductors, so a voltage number alone does not tell you what a winding receives. Single-phase, star and delta connections give different relationships between line and phase values. You will use those relationships to calculate power, judge balance and read motor nameplates. The same principles explain a building supply, an electric vehicle charger, and a 400 Hz aircraft system.
5.1 Single-phase supplies and conductors
A single-phase load receives one alternating voltage between two current-carrying conductors. These can be line and neutral, or two lines. A protective earth conductor serves protection and is not the intended load-current return.
Identify conductor functions
The line conductor is also called phase or, in North America, hot. The neutral is connected to the source's neutral point and commonly bonded to earth at the source or service arrangement. It carries load current. Protective earth, also called equipment ground, provides a fault-current path to help protective equipment disconnect a fault. Equipment can also produce small normal leakage currents in protective conductors.
Neutral is normally near earth potential in an earth-referenced supply, but load-related voltage drop or a broken connection can put it at a dangerous voltage. Confirm conductor functions and prove the circuit dead before contact; a color or nominal voltage is not proof of safety.
Compare common supplies
| Supply | Source arrangement | Voltage used by a load |
|---|---|---|
| 230 V, 50 Hz | One line and neutral of a 230/400 V network | 230 V line to neutral |
| 120/240 V, 60 Hz | One winding with a grounded center tap | 120 V from either end to neutral, 240 V end to end |
| 230 V line to line | Two lines of a 3 × 230 V network | 230 V between lines |
The 120/240 V arrangement is split-phase. The two hot-to-neutral voltages are 180° apart, so their end-to-end voltage is 240 V. It is a single-phase source from one transformer winding. Two hot conductors do not make it a three-phase supply. Receptacles commonly use 120 V; larger loads such as ranges and water heaters may use 240 V.
These are nominal rms voltages. Actual values vary; many European public supplies use a normal service range around 230 V, commonly described as ±10%. A circuit calculation uses the stated voltage, while equipment selection also checks the allowed operating range.
Calculate load current
For a sinusoidal single-phase load:
A resistor has power factor 1. A 3 kW kettle on 230 V therefore takes . A 1.5 kW kettle on 120 V takes . At the same active power and power factor, lowering voltage raises current. For a motor, include power factor when converting active electrical input power into current.
Read colors as identification clues
In common European wiring, single-phase line is brown, neutral blue, and protective earth green-and-yellow; black and gray also identify lines in three-phase wiring. In US wiring, black and red are common hot colors, white or gray identify neutral, and green or bare copper identify equipment ground. Hot colors are not a universal fixed phase sequence. Older installations and some equipment use other conventions.
Single-phase power pulsates at twice supply frequency. A single-phase induction motor's main winding produces a pulsating magnetic field; an auxiliary winding with phase shift or shaded poles provides starting torque. A three-phase supply instead supports a rotating field directly, which suits larger motors and heavy loads.
Key Takeaways
- A single-phase load can be connected line to neutral or line to line.
- Neutral carries load current; protective earth is not the intended load return.
- Split-phase 120/240 V comes from a center-tapped single-phase winding.
- Use electrical input power and power factor when calculating motor supply current.
- Conductor colors depend on the wiring convention and do not prove a circuit safe.
5.2 Star, delta, line and phase values
A three-phase source produces three equal-frequency voltages spaced by 120 electrical degrees. The order of their peaks is the phase sequence, often L1–L2–L3. At 50 Hz the time spacing is one third of 20 ms, about 6.67 ms.
Separate line from phase
A line voltage is measured between two line conductors. A phase voltage is across one source winding or load element. Line current flows in a line conductor; phase current flows through one winding or element. First identify the connection, then decide which quantity a number describes.
| Connection | Voltage relationship | Current relationship |
|---|---|---|
| Star, or wye (Y) | for balanced phase voltages | |
| Delta | for balanced branch currents |
In star, one end of each winding joins at a star point. It can provide a neutral connection. Each line feeds one winding directly, which explains the current equality. The line voltage is the difference of phase voltages 120° apart:
It is not twice phase voltage. A 230/400 V star supply has about 230 V line to neutral and 400 V line to line. Other nominal pairs include 120/208 V, 277/480 V and 115/200 V.
In delta, the windings form a closed loop, each directly between two lines. Each winding therefore receives line voltage. A line conductor joins two winding branches, and its current is their phasor difference. A delta has no star point and no neutral.
Compare the same heating elements
Connect three equal 46 Ω elements to a 400 V line supply. In delta each receives 400 V:
Total power is .
In star each receives . Phase and line current are both about 5.02 A, and total power is about 3.48 kW. With the same elements and line voltage, delta gives three times the star power and three times the line current. The change comes from the voltage across each resistance.
Interpret supply readings
On a healthy 230/400 V supply, any line-to-line pair reads about 400 V and each line-to-neutral pair about 230 V. Neutral to earth is normally close to zero. One 230 V measurement between unidentified conductors cannot identify them: line to neutral, line to protective earth, and line to line on a 230 V network can produce that reading.
Parts of Belgium also have 3 × 230 V networks with three lines and no distributed neutral. Single-phase loads then connect between two lines. A motor labeled 230/400 V Δ/Y uses delta on that 230 V line supply and star on a 400 V line supply. Always attach the supply voltage to a conductor pair before attaching it to a winding.
Key Takeaways
- Three-phase voltages are separated by 120 electrical degrees.
- Phase values belong to one winding or element; line values belong to supply conductors.
- Balanced star voltage uses , while star currents are equal.
- Delta voltages are equal; balanced delta current uses .
- The same resistive elements take three times the power in delta as in star at the same line voltage.
- One voltage measurement cannot establish unidentified conductors’ functions.
5.3 Three-phase power and load balance
A balanced load has equal phase impedances. On a balanced source its currents have equal magnitudes and remain 120° apart. You can calculate total power from one phase and multiply by three, or use line quantities directly.
Use the right voltage and current pair
For balanced sinusoidal three-phase loads in star or delta:
The phase form of active power is . Use line voltage with line current in the first formula, or phase voltage with phase current in the second. Mixing them adds or removes a factor of .
A motor on 400 V takes 10 A per line at power factor 0.85. Apparent power is . Active input is about 5.89 kW; reactive power is about 3.65 kvar.
To find line current from active input:
An 11 kW electrical load on 400 V at 0.86 power factor takes about 18.5 A per line. An 11 kW shaft-output label would need an efficiency conversion before this calculation.
Explain the neutral current
Three equal sinusoidal currents 120° apart add to zero at the neutral. With unequal currents, cancellation is incomplete. For three loads having the same power-factor angle:
With 10 A, 8 A and 6 A resistive loads, the quantity inside the square root is:
Neutral current is therefore . It is not the 4 A difference between largest and smallest current. For 10 A, 10 A and 4 A it is 6 A; for 16 A, 16 A and zero it is 16 A. The relative directions are part of the sum.
The formula's equal-power-factor-angle condition matters. If branch currents have different phase shifts, their directions need separate treatment. Likewise, the balanced three-phase power formula is not a shortcut for an arbitrary unbalanced load; use the actual phase powers.
Share the load across phases
Distribute single-phase loads across L1, L2 and L3. Better balance reduces the largest line current and usually lowers neutral current and losses. It also helps keep phase voltages even. Unequal phase voltages can make a three-phase motor run hotter. Balanced sinusoidal three-phase power is constant in time, giving smoother motor torque than single-phase power.
An open neutral in an unbalanced star system lets the load star point move. Some loads can then receive voltages approaching line voltage instead of their intended line-to-neutral voltage, damaging equipment.
Electronic loads add a second issue: their third-harmonic currents can reinforce in the neutral. Equal rms currents on all three lines therefore do not guarantee zero neutral current when the waveforms are distorted.
Key Takeaways
- Balanced three-phase power uses line voltage and line current with .
- Shaft output requires efficiency to obtain electrical input power.
- Equal sinusoidal currents 120° apart cancel in the neutral.
- Unbalanced neutral current is a directional sum, not a simple difference.
- The stated neutral formula requires equal power-factor angles.
- A broken neutral can expose loads to excessive voltage.
- Third-harmonic currents can add in the neutral despite equal line rms currents.
5.4 Motors, chargers and aircraft equipment
Three-phase currents in stator windings create a rotating magnetic field. This connects supply frequency with motor speed, while the winding voltage determines the correct star or delta connection. The same three-phase ideas also appear inside vehicle drives and aircraft electrical systems.
Relate frequency to speed
The rotating field's synchronous speed is:
Here is the number of pole pairs. With two pairs, synchronous speed is 1500 rpm at 50 Hz and 1800 rpm at 60 Hz. An induction motor rotor turns slightly slower under normal motoring conditions. At 1450 rpm against a 1500 rpm field, slip is , or about 3.3%.
Phase sequence sets field direction. Interchanging any two lines reverses it. Direction is checked before a pump, fan or compressor enters service because some equipment can be damaged by reverse rotation. Losing one line is different: a running motor may continue with excessive current and heating, while a stopped motor may only hum. Overload and phase-failure protection address that condition.
Read the winding rating
A nameplate reading 230/400 V Δ/Y means each winding is rated 230 V. On a 400 V line supply, use star:
On a 230 V line supply, use delta and each winding receives 230 V. Delta on 400 V would place 400 V across a 230 V winding and cause severe overheating. Terminal links establish the connection; the two nameplate numbers belong to their stated connection symbols.
Star-delta starting applies to a motor intended to run in delta at the available line voltage. Starting in star reduces winding voltage to of direct-delta voltage. Starting line current and starting torque are each about one third of direct-delta values. On a 400 V supply, a 400/690 V Δ/Y motor can run in delta; a 230/400 V Δ/Y motor must run in star and is not suitable for that star-delta changeover.
Follow energy through an electric vehicle
A vehicle battery stores DC. During AC charging, the on-board charger rectifies supply AC to charge the battery. A 230 V, 32 A single-phase connection offers about 7.4 kW at unity power factor. A compatible charger on 400 V three-phase at 16 A per line can take about .
For propulsion, an inverter converts battery DC into three-phase AC with controlled frequency and voltage. Frequency controls the motor field speed. During regenerative braking, the motor generates and the inverter returns energy to the battery. A building variable-speed drive similarly rectifies incoming AC and creates an adjustable-frequency three-phase output for a pump or compressor.
Recognize aircraft supplies
A common aircraft supply is 115/200 V, three-phase, 400 Hz: about 115 V phase to neutral and 200 V line to line. The higher frequency permits smaller transformers and motors. Pumps and galley ovens can use the AC supply; transformer-rectifier units provide 28 V DC equipment power. Some newer aircraft use variable-frequency generation, roughly 360–800 Hz, following engine speed. Supply frequency and connection are therefore both part of the equipment match.
Key Takeaways
- Synchronous speed depends on frequency and pole pairs.
- An induction rotor normally runs below synchronous speed.
- A Δ/Y nameplate states the line voltages for each connection.
- Star-delta starting requires a motor rated to run in delta on that supply.
- EV chargers convert AC to DC; traction inverters create controlled three-phase AC.
- Aircraft commonly use 115/200 V at 400 Hz, with other generation arrangements also in service.
Alternating Current examples
1Read a trace and find its rated values
12 steps
- 1IntroductionTwo scales, two questions
A waveform has a time scale and a voltage scale. The time scale tells you how often its pattern repeats; the voltage scale tells you how far it moves above and below zero.
You will read a 50 Hz sine wave, then turn its peak measurement into an rms value. Keep the two jobs separate: a faster waveform need not be taller.
- 2ExplanationMark one complete cycle
Start at an upward zero crossing. Follow the trace to its positive peak, down through zero, to its negative peak, then back to the next upward crossing. That is one complete cycle, or 360°.
The first peak is at 90°, the next zero crossing at 180° and the negative peak at 270°. Two adjacent zero crossings are only half a cycle apart, so their spacing cannot be used directly as the full period.
- 3ExampleTurn divisions into a period
The trace takes four horizontal divisions for one full cycle. The time setting is 5 ms per division, so multiply the span by the scale:
Convert this to 0.020 s before calculating frequency. Measuring between two positive peaks would give the same full-cycle time.
- 4ExampleTake the reciprocal
Continue with the 0.020 s period. Frequency counts how many of those cycles fit into a second:
A 60 Hz wave would take about 16.7 ms per cycle; a 400 Hz wave would take only 2.5 ms. The smaller time per cycle means more cycles each second. Entering 20 instead of 0.020 would turn a millisecond reading into an incorrect frequency.
- 5ExampleFind a point inside the cycle
The same wave has a peak of 325 V. At 2.5 ms after its upward zero crossing, its angle is:
Use degree mode, then calculate:
This is an instantaneous value at one time. At the 90° peak the same waveform reaches 325 V.
- 6ChallengeRead a new time scale
A reduced-voltage waveform takes five divisions per cycle at 0.5 ms/div. What frequency does it have?
---reveal---
The period is . Therefore .
- 7ExampleRead the vertical span
The 50 Hz trace spans 6.5 vertical divisions from negative peak to positive peak at 100 V/div:
Because it is symmetrical about zero, the peak is half the full span, or 325 V. This reading covers both sides of zero. Using all 650 V as the peak would double every later peak-based calculation.
- 8ExplanationConvert peak into rms
The rms value describes the DC-equivalent heating effect in a resistor. For this sine wave:
Both halves of the cycle heat a resistor because current reverses with voltage. The signed average voltage is zero, but its heating value is not. An average-responding meter scales its rectified average to show rms only when the waveform is sinusoidal.
- 9ChallengeCheck a low-voltage sine wave
A sine wave is symmetrical about zero and measures 72 V peak to peak. What rms voltage should a suitable AC meter show?
---reveal---
Peak voltage is . Its rms value is .
A reading calculated as would use the full peak-to-peak span as the peak.
- 10TipChoose a meter for the waveform
A drive can draw current in pulses even when its supply voltage looks sinusoidal. An average-responding meter's fixed scaling does not correctly describe every pulse shape.
Use a true-rms meter suited to the waveform's frequency content and measurement ratings. The sine-wave relationship between peak and rms also depends on shape: a symmetrical square wave has rms equal to its peak magnitude.
- 11ChallengeCombine both scale readings
A zero-centered sine wave spans six vertical divisions at 4 V/div. One cycle takes eight horizontal divisions at 0.25 ms/div. Find its frequency and rms voltage.
---reveal---
The period is 2 ms, or 0.002 s, giving 500 Hz. Peak-to-peak voltage is 24 V, so peak is 12 V and rms is .
- 12RecapLabel the value before using it
Before using a waveform reading in an equipment calculation, attach its meaning: full-cycle time, frequency, instantaneous value, peak, peak to peak or rms.
A heater calculation needs rms voltage. A waveform peak matters to insulation stress. A generator-frequency check needs both pole pairs and rpm.
2Predict current timing and reactance
14 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionWhat sets current timing?
- 2ExplanationRead lead and lag
- 3ExampleStart with a resistor
- 4ChallengeInterpret a time delay
- 5ExplanationA coil opposes current change
- 6ExampleConvert reactance into current
- 7ChallengeChange frequency without changing the coil
- 8Key InsightUse measurements for a real coil
- 9ExplanationA capacitor responds to voltage change
- 10ExampleCalculate capacitor opposition
- 11ChallengeTest the capacitor’s response
- 12ConnectionConnect the rule to a filter
- 13ChallengeCompare two ideal branches
- 14RecapMake a physical prediction first
3Solve series and parallel mixed circuits
17 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionChoose the shared quantity
- 2ExplanationDraw the series triangle
- 3ExampleFind the common current
- 4ExampleRecover the component voltages
- 5ExampleFind the phase angle
- 6ChallengeSolve a new RC circuit
- 7ExampleAdd the opposing reactive parts
- 8Key InsightCheck the larger internal voltages
- 9ExplanationLocate series resonance
- 10ChallengePredict a resonance change
- 11ExplanationSwitch from voltages to currents
- 12ExampleWork a parallel current triangle
- 13ChallengeApply cancellation in a new case
- 14ExampleSplit a real motor’s current
- 15ConnectionDistinguish the two resonances
- 16ChallengeCombine a motor, heater and capacitor
- 17RecapCheck the circuit arrangement
4Size a capacitor correction
15 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionSeparate energy conversion from demand
- 2ExampleCalculate apparent and active power
- 3ExampleComplete the power triangle
- 4ChallengeUse a new power triangle
- 5ExplanationFind the current penalty
- 6ChallengeInterpret measured power
- 7TipCheck what the meter’s angle means
- 8ExplanationSet a correction target
- 9ExampleFind the reactive reduction
- 10ExampleTurn reactive power into capacitance
- 11Key InsightIdentify what changes
- 12ChallengeCalculate another correction
- 13ConnectionLet the correction follow the load
- 14ChallengeCombine the power and current checks
- 15RecapCheck power before judging savings
5Match supply values to real equipment
20 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionRead the conductor pair first
- 2ExplanationFollow the normal current path
- 3ExplanationRecognize a center-tapped source
- 4ChallengeCalculate a single-phase input
- 5ExplanationSeparate line from winding
- 6ExplanationUse star relationships
- 7ExplanationUse delta relationships
- 8ExampleCompare the same heating elements
- 9ChallengeConvert a new connection
- 10ExplanationCalculate balanced three-phase power
- 11ExampleRead the neutral’s cancellation
- 12ChallengeRemove one phase load
- 13Key InsightKnow where cancellation fails
- 14ExplanationConnect frequency with motor speed
- 15ExplanationRead a Δ/Y nameplate
- 16ChallengeCheck a proposed starter
- 17ConnectionFollow power through a vehicle
- 18ConnectionRecognize an aircraft system
- 19ChallengeCombine charging current and neutral balance
- 20RecapMatch values to the equipment
Alternating Current practice questions
Set 1: Read waveforms and component timing10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Choose the right circuit calculation10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Diagnose mixed circuits and resonance10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Calculate demand and capacitor correction10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 5: Read supply labels and winding connections10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 6: Solve equipment and supply problems10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
A
Active power
Alternating current
Apparent power
Average-responding meter
B
Balanced load
Branch current
C
Capacitance
Capacitive reactance
Capacitor bank
Choke
Current triangle
Cycle
D
Delta connection
Detuned bank
Dielectric
Displacement power factor
E
Efficiency
Electric field
F
Frequency
H
Half-cycle average
I
Impedance
Impedance triangle
In-phase current component
In-phase quantities
Inductance
Inductive reactance
Instantaneous value
K
Kilowatt-hour
L
Lagging quantity
Leading quantity
Line current
Line voltage
M
Microfarad
N
Net reactance
Neutral conductor
Neutral current
Nominal voltage
O
Overcorrection
P
Parallel resonance
Peak value
Peak-to-peak value
Period
Phase current
Phase difference
Phase sequence
Phase voltage
Phasor
Pole pair
Power analyzer
Power factor
Power triangle
Power-factor correction
Protective earth
R
Reactive current component
Reactive power
Resonant frequency
rms value
Rotating magnetic field
S
Self-induction
Series RC circuit
Series resonance
Series RL circuit
Single-phase supply
Slip
Split-phase supply
Star connection
Star-delta starting
Synchronous speed
T
Third harmonic
Three-phase supply
Traction inverter
Transformer-rectifier unit
True-rms meter
V
Voltage magnification
Voltage triangle
W
Winding resistance
About this lesson
Make your own Study Materials
Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.