Thevenin and Norton Equivalents

Learn to replace any linear resistive circuit, as seen from two terminals, by one source and one resistance. Find Thevenin and Norton equivalents from the open-circuit voltage, the short-circuit current or a test source, including circuits with dependent sources. Then use them to predict what a load receives, choose the load that draws the most power, weigh that against efficiency, and recognize and measure loading effects on dividers, amplifier stages and meters.

IntermediateLesson 4 of 8 in Electric Circuits 1 Course

What you will learn

  1. Describe a linear circuit by its behavior at two terminals and reduce it to one voltage source in series with one resistance.
    • Describe a circuit by what it does at two terminals
      Explain what a two-terminal equivalent is, what Thevenin's theorem states, and why the open-circuit voltage and short-circuit current fix it.
    • Find the Thevenin voltage from the open-circuit voltage
      Remove the load, find the voltage between the open terminals with a suitable analysis method, and keep track of its sign.
    • Find the Thevenin resistance by turning off independent sources
      Set every independent source to zero, redraw the circuit as seen from the terminals, and combine the resistances.
  2. Represent a linear circuit as a current source in parallel with a resistance, and move between Norton form, Thevenin form and source transformations.
    • Find the Norton current and resistance
      Find the short-circuit current and the equivalent resistance of a network, draw its Norton equivalent with the correct direction, and use it to find load currents.
    • Convert between forms and reduce circuits by source transformation
      Switch between Thevenin and Norton forms, use source transformations to simplify a circuit step by step, and recognize the cases where one form does not exist.
  3. Keep dependent sources active, and find Thevenin and Norton equivalents from the open-circuit voltage, the short-circuit current or a test source.
    • Use the open-circuit voltage and short-circuit current with dependent sources
      Find the Thevenin voltage, Norton current and equivalent resistance of a network with a dependent source, recomputing the controlling variable for each terminal condition.
    • Find the equivalent resistance with a test source
      Apply a test voltage or current at the terminals, compute the ratio, and interpret networks that have no independent sources or a negative equivalent resistance.
  4. Use an equivalent to find the current, voltage and power of any load, choose the load that receives the most power, and weigh that choice against efficiency.
    • Analyze a changing load with the Thevenin equivalent
      Find load current, voltage and power for a range of loads from one equivalent, and read the operating point from the source line.
    • Apply the maximum power transfer theorem
      State and derive the condition for maximum load power, compute the maximum power, and choose the best load from a limited set of values.
    • Weigh maximum power against efficiency
      Compute the efficiency of power transfer, explain why power systems avoid matching, and choose the source resistance when the load is fixed.
  5. Use equivalents to predict how connecting a load, a following stage or a meter changes a circuit, and measure an equivalent on the bench.
    • Predict how a load pulls down a divider or source
      Quantify the drop in output when a load is connected, size a divider or the next stage to keep it small, and apply the same idea to current sources.
    • Account for meter loading when measuring
      Model voltmeters and ammeters as resistances, predict the reading they give, and correct or avoid the error.
    • Measure a Thevenin equivalent on the bench
      Find the Thevenin voltage and resistance of a real source from open-circuit, known-load and two-load measurements, and use them safely.

Thevenin and Norton Equivalents study guide

5 chapters

1

Replace a network with one voltage source

A fixed source network can feed many different loads. Reducing it to a voltage source and one series resistance lets you solve each load without rebuilding the full nodal equations. The reduction begins at a clearly chosen pair of terminals: find the voltage with the load removed, then find the resistance seen from those same terminals. Keeping the voltage polarity and current direction visible makes the equivalent useful from the first calculation.

1.1 What stays the same at the terminals

A circuit can contain many branches while connecting to its load through just two terminals. That part is a one-port: current enters one terminal and leaves the other. Its useful description is the relationship between terminal voltage and current.

Set the reference directions

Call the terminals a and b. Define v=va−vb, and take i as the current leaving a, passing through the external circuit, and returning at b. For a linear resistive network with a Thevenin form,

v=VTh−RThi.

The negative sign follows from the chosen current direction. For positive equivalent resistance, delivering more current produces a larger internal voltage drop. Resistors and independent sources, together with dependent sources proportional to an internal voltage or current, give a linear terminal relationship.

Replace the network

Thevenin's theorem replaces that network by an ideal voltage source in series with a resistance. Draw the positive source terminal toward a. A negative calculated voltage is meaningful: keep the sign, or reverse the drawn source and label it with the positive magnitude. The name also appears with its original accent, Thévenin.

The two-terminal replacement gives the same voltage and current for any connected external circuit. The external load can even be nonlinear; linearity is needed in the network being replaced. The boundary must keep the control relationships intact. A source inside the replaced network cannot depend on an external branch variable that disappears from its model; choose the boundary or express the control through terminal quantities accordingly.

Two useful points on the line

An open circuit carries no external current, so its voltage is VTh=voc. A short forces the terminal voltage to zero, so its current is isc=VTh/RTh. When both measurements are nonzero, their ratio gives RTh=voc/isc. An ideal current source alone has a Norton form but no finite Thevenin form.

Consider Circuit A: a 24 V source feeds node x through 4 Ω; 12 Ω connects x to the bottom rail; 2 Ω connects x to a; b is on the bottom rail. Its equivalent is 18 V in series with 5 Ω. A 13 Ω load therefore draws

i=185+13=1 A,v=1⋅13=13 V.

The full circuit gives those same load values. This is why one reduction saves work when the load changes.

What the equivalent does not preserve

The replacement describes the external circuit. It does not reproduce currents or losses inside the original network. With Circuit A open, the original 4 Ω and 12 Ω resistors still carry current and dissipate 242/16=36 W. The open Thevenin model carries no current and dissipates zero. To find original resistor heating or supply power, return to the original circuit.

Key Takeaways

  • A one-port is described by its terminal voltage-current relationship.
  • With current leaving a, v=VTh−RThi.
  • An equivalent preserves external voltages and currents, including with a nonlinear load.
  • Open-circuit voltage gives VTh; internal losses require the original circuit.

1.2 The voltage with the load removed

The Thevenin voltage is the voltage between the two open terminals. Remove the load before solving. The remaining network stays powered; opening the output does not switch off its internal sources or branches.

A terminal resistor can have zero drop

Use Circuit A: 24 V feeds node x through 4 Ω, a 12 Ω resistor joins x to b, and 2 Ω joins x to the open terminal a. No current can leave through a. Because the 2 Ω resistor is the only element in that terminal branch, its current is zero and its voltage drop is zero.

The 4 Ω and 12 Ω resistors still form a conducting loop with the source. Their current is 24/(4+12)=1.5 A. The output is the voltage across 12 Ω:

VTh=vx=24124+12=18 V.

Including the 2 Ω in the divider would assign it a current path that the open circuit does not provide. Zero current means zero drop across a finite resistor; an ideal voltage source can maintain voltage while carrying zero current.

Use KCL when a divider is not enough

Circuit B has a 10 V source connected through 5 Ω to a, a 2 A source injecting current from b into a, and 20 Ω across a and b. With b as reference, the two resistor currents leaving a must equal the injected 2 A:

va−105+va20=2.

Multiplying by 20 gives 4(va−10)+va=40. Thus 5va=80 and VTh=16 V. There is no external load, but the internal 20 Ω branch still carries current.

Superposition provides a useful check. The voltage source alone, with the current source opened, produces 10(20/25)=8 V. The current source alone, with the voltage source shorted, sees 5∥20=4 Ω and produces another 8 V. Their signed contributions add to 16 V.

When neither terminal is the reference node

A 12 V source feeds two divider branches. The left branch has 6 Ω above a and 12 Ω below it. The right branch has 12 Ω above b and 6 Ω below it. With the bottom rail as reference,

va=121218=8 V,vb=12618=4 V.

The requested voltage is vab=8−4=4 V. Using the 8 V node voltage alone would miss the second terminal's potential. Reversing the order gives vba=−4 V; this is the same physical result with the opposite reference polarity.

Choose the simplest valid analysis for the open network: a divider when the path permits it, KCL for interacting branches, or superposition when the separate contributions are easy. Record the terminal order beside the result so the source polarity remains unambiguous when you draw the equivalent.

Key Takeaways

  • Remove the external load while leaving the source network active.
  • An open-ended terminal resistor carries no current and has no voltage drop.
  • Find va−vb even when neither terminal is ground.
  • Use the signed open-circuit result to set the equivalent source polarity.
  • KCL and superposition can find the open voltage when a divider cannot.

1.3 The resistance seen from the output

Equivalent resistance describes how strongly terminal voltage changes as the network delivers current. For a resistor network with independent sources, find it by removing the load, setting the sources to zero, and looking back into the same two terminals.

Zero a source according to what it controls
Independent sourceZero-value replacementReason
Voltage sourceShort circuitIt holds zero voltage between its terminals.
Current sourceOpen circuitIt forces zero current through its branch.

Keep the resistors, including any resistance belonging to a real source model. Zeroing an ideal source changes its electrical constraint; it does not mean erasing its whole branch. In the terminal equation, removing the independent excitation removes the voltage intercept, leaving the resistance that sets the slope.

Redraw Circuit A from a and b

Circuit A has 4 Ω between the 24 V source and node x, 12 Ω between x and b, and 2 Ω between x and a. Shorting the voltage source joins the far end of 4 Ω to b. Both 4 Ω and 12 Ω now connect between x and b:

4∥12=4⋅124+12=3 Ω.

From a, current must pass through 2 Ω before splitting through that parallel pair. Therefore,

RTh=2+3=5 Ω.

The terminal 2 Ω had no drop during the open-voltage calculation, but it contributes to the resistance seen by an attached load. Its role depends on the terminal condition.

Circuit B contains a 10 V source with 5 Ω in series, a 2 A source, and 20 Ω across the output. Short the voltage source and open the current source. The remaining resistance is 5∥20=4 Ω. Shorting the current source instead would wrongly place a wire directly across the output.

Connections decide series and parallel

For the bridge with a 12 V supply and divider legs 6/12 Ω and 12/6 Ω, the shorted supply joins its top and bottom rails. Each midpoint then sees a parallel pair to that joined rail:

Ra=6∥12=4 Ω,Rb=12∥6=4 Ω.

Between a and b the two 4 Ω combinations are in series, so the equivalent resistance is 8 Ω. Resistors drawn beside one another are not necessarily parallel: they must share both end nodes. Label the joined nodes after replacing each source.

Preserve sources that respond to the circuit

A dependent source remains active. Its controlling voltage or current changes when a test signal is applied, so removing that source changes the terminal response. Use a test source or a nonzero open-voltage/short-current ratio for such a network.

Some resistors affect internal power without affecting the port: a resistor in series with an ideal current source cannot change its fixed branch current, and one across an ideal voltage source cannot change its fixed branch voltage. With internally contained controls, these elements can disappear from the port calculation while still dissipating power in the original network.

Key Takeaways

  • Zero independent voltage sources with shorts and current sources with opens.
  • Keep source-model resistances in the network.
  • Determine series and parallel connections by shared nodes after redrawing.
  • A terminal resistor can affect equivalent resistance even when its open-circuit drop is zero.
  • Dependent sources stay active.
  • Equivalent resistance concerns the port; some internal losses remain hidden.
2

Build a current-source equivalent

The same terminal behavior can often be drawn in a second way: a current source in parallel with a resistance. Short-circuit analysis makes this Norton form natural, while source transformations let you move between current-source and voltage-source circuits as you simplify branches. The resistance stays the same in both forms. The source direction, the two terminals, and the series or parallel connection determine whether a transformation is valid.

2.1 Short-circuit current and the Norton model

A Norton equivalent is an ideal current source in parallel with a resistance. Its current is the current that would flow through a wire joining the output terminals. Its resistance equals the Thevenin resistance of the same network.

Choose the current direction

Define positive short-circuit current through the external wire from a to b. Draw the Norton source arrow inside the network from b toward a. It then pushes current out through a and back through the short. With the terminals open, the source current instead returns through the parallel resistance, making a positive relative to b.

Thus IN=isc and RN=RTh. A negative result means actual current opposes the reference arrow; the signed calculation still works.

Find the current through the short itself

In Circuit A, a 24 V source feeds node x through 4 Ω, 12 Ω joins x to b, and 2 Ω joins x to a. Short a to b. The 2 Ω resistor is now another branch from x to b, in parallel with 12 Ω:

12∥2=12⋅212+2=127 Ω.

The node voltage is

vx=2412/74+12/7=7.2 V.

The short carries the current through the 2 Ω branch: isc=7.2/2=3.6 A. The source supplies 24/(4+12/7)=4.2 A, but 0.6 A returns through 12 Ω. Equating supply current with short current would count that internal branch incorrectly.

Since the equivalent resistance is 5 Ω, Circuit A becomes a 3.6 A source in parallel with 5 Ω. Its open voltage is 3.6⋅5=18 V, agreeing with the Thevenin result.

Circuit B offers a shorter short-circuit calculation. Its 20 Ω resistor is directly across a and b, so a short gives that branch zero voltage and zero current. The 10 V source through 5 Ω sends 2 A into a, and the current source adds 2 A. The short carries 4 A; with 4 Ω Norton resistance, its open voltage is 16 V.

Use current division with a load

An attached load is parallel to the Norton resistance. KCL gives IN=v/RN+v/RL. Solving for the load current yields

iL=INRNRN+RL.

For a 13 Ω load on Circuit A, iL=3.6(5/18)=1 A and vL=13 V. The numerator is the resistance of the other branch. Writing the load resistance in the numerator would calculate current through the internal Norton resistance.

Read the limiting cases

With the output shorted, zero voltage across a finite parallel resistor means zero resistor current. All Norton current then takes the wire. With the output open, no external current flows, but the Norton source still drives its parallel resistor. This internal current explains why the Norton and Thevenin drawings can dissipate different internal powers while giving identical load results.

Some diagrams label the parallel element by conductance instead of resistance. Then GN=1/RN, in siemens, and terminal KCL reads i=IN−GNv. For 5 Ω, conductance is 0.2 S, not 5 S. Check whether the given parallel value is in ohms or siemens before using it.

Key Takeaways

  • Norton current is the external short-circuit current from a to b.
  • The source arrow points toward the terminal that is positive in Thevenin form.
  • Norton and Thevenin resistances are equal.
  • Find current in the short branch, accounting for internal current paths.
  • Current division gives iL=INRN/(RN+RL).

2.2 Convert sources without changing the port

Choose the equivalent form that makes the next calculation easier. Series voltage sources combine directly; parallel current sources combine directly. A valid source transformation changes the source and its associated resistor together while preserving their two-terminal behavior.

Keep the same resistance and polarity
Thevenin formNorton form
Voltage source VTh in series with RCurrent source IN=VTh/R in parallel with R
Positive source side toward aCurrent arrow toward a
Open voltage VThOpen voltage INR

For Circuit A, 18 V with 5 Ω becomes 18/5=3.6 A with 5 Ω in parallel. Dividing volts by ohms gives amperes. Multiplying would give the wrong units as well as the wrong value.

Reduce Circuit A in stages

Start with its 24 V source and series 4 Ω resistor, feeding 12 Ω to the bottom rail and then 2 Ω to the output.

  1. Transform the 24 V and 4 Ω pair into a 24/4=6 A source in parallel with 4 Ω.
  2. Combine the 4 Ω and 12 Ω resistors across the same nodes: 4∥12=3 Ω.
  3. Transform the 6 A source with 3 Ω into 6⋅3=18 V in series with 3 Ω.
  4. Add the remaining terminal 2 Ω in series to obtain 18 V with 5 Ω.

Each stage preserves the behavior seen by the circuit still outside it. A resistor can be transformed with a voltage source only when it is in series with that source; a current-source resistor must be in parallel.

Combine parallel source branches

An 18 V source with 6 Ω series resistance and a 3 V source with 3 Ω series resistance share output terminals, with both positive sides toward a. Convert them to 3 A and 1 A Norton sources. The currents add to 4 A, and 6∥3=2 Ω. The combined Thevenin voltage is 4⋅2=8 V. Adding the original 18 V and 3 V directly would be a series-source operation applied to parallel branches.

Source signs survive every stage. If the 1 A Norton branch in the preceding parallel example points toward b instead of a, the net current is 3−1=2 A toward a. The resistance remains 2 Ω, but the open voltage becomes 4 V. Current direction changes the signed sum; it does not change how the parallel resistors combine.

Know what the conversion leaves behind

Do not absorb a resistor into an equivalent when its own current or voltage is the quantity you need. Its original branch detail disappears. At open circuit, Circuit A's original resistors dissipate 36 W, the Thevenin model dissipates zero, and the Norton model dissipates 3.62⋅5=64.8 W. All three still give 18 V at the port.

An ideal voltage source has zero series resistance and no finite Norton form: its short-circuit current is unbounded. An ideal current source with infinite parallel resistance has no finite Thevenin form. A zero-voltage Thevenin source with finite resistance reduces to that resistance alone.

Key Takeaways

  • Convert with VTh=INR and IN=VTh/R.
  • Transform a source together with its correctly connected resistor.
  • Add parallel Norton currents with their directions and combine their resistances in parallel.
  • Keep an element outside a transformation when you need its individual current or voltage.
  • Ideal voltage and ideal current sources are limiting cases that lack one finite equivalent form.
  • Source transformation preserves the port, not internal power.
3

Keep controlled sources in the calculation

A controlled source changes when the circuit changes. Opening or shorting the output therefore changes both the terminal condition and the controlling variable. Solving those conditions separately gives one route to an equivalent. A test source gives another: remove independent excitation, keep the control equations, and measure the response mathematically. That method also handles networks with no independent source and reveals negative equivalent resistance.

3.1 Recalculate the control for each terminal condition

A dependent source takes its value from a voltage or current elsewhere in the circuit. Its value is not a fixed independent input. A constant gain times the controlling variable makes the source linear, allowing it to remain part of a linear equivalent network.

Identify the control relationship
KindOutput depends on
VCVSVoltage controlled by voltage
CCVSVoltage controlled by current
VCCSCurrent controlled by voltage
CCCSCurrent controlled by current

Record the control variable's reference direction or polarity before writing KCL or KVL. Keep that reference when the terminal condition changes. All control relationships must remain available within the replacement boundary or be expressed through terminal quantities.

Open Circuit C

A 12 V source feeds a through 4 Ω. Define ix through that resistor toward a. A 12 Ω resistor and a dependent current source both connect a to b; the source draws 0.5ix from a to b. With no load, KCL is

ix=va12+0.5ix.

Rearranging gives ix=va/6. The feed resistor also gives ix=(12−va)/4. Equate the two expressions:

6(12−va)=4va,va=7.2 V.

Thus VTh=7.2 V, ix=1.2 A, and the dependent source draws 0.6 A in the open condition.

Short Circuit C

Joining a to b sets va=0. The feed current changes to ix=12/4=3 A. The dependent source now draws 0.5⋅3=1.5 A. The 12 Ω resistor carries zero current because its voltage is zero.

The remaining current takes the short:

isc=3−1.5=1.5 A.

Therefore RTh=7.2/1.5=4.8 Ω, and the Norton form is 1.5 A in parallel with 4.8 Ω. Reusing the open-condition 0.6 A source value would give 2.4 A in the short and an incorrect resistance.

You can also check the complete port relation directly. At any terminal voltage, the feed is (12−v)/4. After subtracting the dependent branch and the 12 Ω branch, delivered current is

i=0.512−v4−v12=1.5−5v24.

Rearranging gives v=7.2−4.8i, showing the same voltage intercept and resistance without treating the control value as constant.

Why turning the source off fails

A dependent source continues to respond when the independent sources are zeroed. Removing it from Circuit C would leave 4∥12=3 Ω. That is the resistance of a different network. The actual controlled response raises the port resistance to 4.8 Ω.

The open/short method works directly when both results are nonzero. Keep all sources active for those two calculations, and write the control equation again under each condition. If both results are zero, dividing them cannot reveal the resistance; an applied test source is needed. The same test-source method also provides an independent check when the ratio is available.

Key Takeaways

  • Keep each dependent source and its control equation in both open and short calculations.
  • Recompute the controlling variable after changing the terminal condition.
  • Short-circuit current is the current left for the external wire after internal branches are counted.
  • Use the nonzero ratio RTh=voc/isc, or check it with a test source.

3.2 Use a test signal to reveal resistance

A network can resist an applied signal even when it produces no voltage or current on its own. A test source supplies that signal. It makes the terminal response visible while the dependent sources continue to follow their control equations.

Set up the test

Remove the load and zero every independent source: short independent voltage sources and open independent current sources. Keep all resistors and dependent sources. Apply a nonzero test voltage or current between a and b.

Define vT=va−vb and iT entering the network at a. These follow the passive resistance convention, so

RTh=vTiT.

This current enters a; the delivered load current used in v=VTh−RThi leaves a. Confusing the two directions reverses the resistance sign. A 1 V or 1 A test is convenient, but any nonzero test value gives the same ratio in a linear network.

Check Circuit C

Short its 12 V source. The 4 Ω feed resistor now runs from a to b, but ix still points toward a from its original source side. Therefore ix=−va/4. Inject 1 A into a and apply KCL:

1+ix=va12+0.5ix.

Substitution gives 1−va/8=va/12, so va=4.8 V. Dividing by the injected 1 A gives 4.8 Ω, matching the open/short result.

A 1 V test on the same deactivated circuit gives ix=−1/4 A. KCL then requires entering current iT=1/12+1/8=5/24 A. The ratio is 1/(5/24)=4.8 Ω. With a 1 V test the resistance is the reciprocal of the current in amperes; only a 1 A test makes resistance numerically equal to the voltage in volts.

No independent source does not mean zero resistance

For a well-defined unexcited linear network with only resistors and dependent sources, the open voltage and short current are both zero. The ratio 0/0 is undefined. A test still gives a useful response.

For example, a 2 Ω resistor is in series with a CCVS of value 3iT V, positive toward the resistor. KVL gives vT=2iT+3iT=5iT. The equivalent is a 5 Ω resistance with zero independent Thevenin voltage.

Interpret a negative result

Put a 10 Ω resistor across a and b, together with a VCCS that injects 0.2vT A toward a. The current entering the whole network is

iT=vT10−0.2vT=−0.1vT.

Thus RTh=−10 Ω. For a positive test voltage, the network sends current back toward the test source. The controlled source supplies power; an ordinary resistor-only network cannot give negative equivalent resistance.

With gain 0.05 S instead, iT=0.1vT−0.05vT=0.05vT, giving 20 Ω. Leaving an independent source active during the test adds its voltage intercept to the response, so the single ratio no longer isolates resistance.

Key Takeaways

  • Zero independent sources and keep dependent sources for a resistance test.
  • Use test current entering the positive-voltage terminal in RTh=vT/iT.
  • A nonzero test avoids the undefined 0/0 ratio of an unexcited network.
  • Keep control references fixed when the topology changes.
  • A controlled source can supply power and produce negative equivalent resistance.
  • Changing test amplitude leaves the resistance ratio unchanged in a linear network.
4

Choose a load for current, voltage, or power

An equivalent turns load analysis into a single loop or a current divider. As the load changes, its current, voltage, and power change in different ways; maximizing one does not maximize the others. The source line makes those changes visible, including for a nonlinear load. For an adjustable resistor, power has a definite peak when source resistance is positive. Efficiency and a fixed-load design require different choices.

4.1 Find the load operating point

Once the source network is reduced, reconnect the load across the original terminals. A resistive load and the Thevenin resistance carry the same current. KVL gives the load current first; Ohm's law then gives its voltage and power.

One loop, three results
iL=VThRTh+RL,vL=VThRLRTh+RL.

Using pL=iL2RL gives

pL=VTh2RL(RTh+RL)2.

The total resistance belongs in the current denominator. Dividing only by the load resistance treats the source as ideal and misses its internal voltage drop.

For Circuit A, VTh=18 V and RTh=5 Ω:

LoadCurrentVoltageLoad power
1 Ω3 A3 V9 W
5 Ω1.8 A9 V16.2 W
10 Ω1.2 A12 V14.4 W
20 Ω0.72 A14.4 VAbout 10.37 W

For the 10 Ω row, iL=18/15=1.2 A, then vL=1.2⋅10=12 V and pL=1.22⋅10=14.4 W. Each new load needs only a new denominator.

Power accounting checks the 10 Ω row. In the equivalent, the 5 Ω source resistance dissipates 1.22⋅5=7.2 W. The ideal 18 V source supplies 18⋅1.2=21.6 W, equal to 14.4 W at the load plus 7.2 W internally. This balance belongs to the equivalent; the original source can supply extra internal branches.

Understand the ends of the range

With positive source resistance, reducing the load toward zero raises current toward the short-circuit value but drives load voltage toward zero. Increasing the load without bound reduces current toward zero while voltage approaches the open-circuit value. The load power is zero at either ideal endpoint. A short has current but no voltage; an open has voltage but no current.

For a positive Thevenin resistance, delivered current lowers terminal voltage by RThiL. The 18 V value is the open voltage, not the voltage across every attached load.

Find the intersection graphically

Plot current horizontally and voltage vertically. The source line v=VTh−RThi crosses the voltage axis at VTh and the current axis at isc. A resistor's line is v=RLi through the origin. The intersection satisfies both the source and the load: it is the operating point. Circuit A with 10 Ω intersects at 1.2 A and 12 V.

A nonlinear device has a curve in place of the resistor's straight line. If a conducting device holds about 2 V, the bridge equivalent of 4 V with 8 Ω leaves 2 V across its source resistance. Its current is (4−2)/8=0.25 A.

The Norton route reaches the same operating point using iL=INRN/(RN+RL). For Circuit A with 1 Ω, this is 3.6(5/6)=3 A.

Key Takeaways

  • Include source resistance when calculating load current.
  • Load voltage follows from the current and load resistance.
  • An ideal open or short receives zero load power.
  • The operating point satisfies both the source line and the load relationship.
  • The replaced network must be linear; its external load can have a nonlinear characteristic.

4.2 Match an adjustable load for maximum power

A very small load takes much current at little voltage. A very large load takes little current at nearly the open voltage. The product of voltage and current peaks between those extremes. For a fixed linear source with positive Thevenin resistance and nonzero source voltage, the adjustable resistive load receives maximum power at

RL=RTh.

The matched resistance is the resistance seen from the load terminals, which can be a combination of many original components.

Derive the peak

Keep the source voltage and resistance fixed while varying the load:

pL=VTh2RL(RTh+RL)2.

Differentiating with respect to the load resistance gives

dpLdRL=VTh2(RTh−RL)(RTh+RL)3.

To see where the numerator comes from, write power as VTh2RL(RTh+RL)−2. The product rule gives

VTh2[(RTh+RL)−2−2RL(RTh+RL)−3].

Putting the terms over one denominator leaves RTh+RL−2RL=RTh−RL in the numerator. Source voltage is constant during this differentiation.

For positive resistances, the denominator is positive. Below the match the derivative is positive, so increasing the load raises its power. Above the match the derivative is negative, so increasing the load lowers its power. The sign change proves a maximum at equality.

Substitute the matched value into the current and power expressions:

vL=VTh2,iL=isc2,pmax⁡=VTh24RTh=IN2RN4.

Circuit A gives 182/(4⋅5)=16.2 W at 5 Ω. Circuit B gives 162/(4⋅4)=16 W at 4 Ω. Circuit C, including its dependent source, gives 7.22/(4⋅4.8)=2.7 W at 4.8 Ω.

Choose from available resistor values

The peak is broad: either twice or half the matching resistance still receives 8/9, about 88.9%, of maximum power. Equal distances in ohms do not give equal power losses, however.

For Circuit A, suppose only 3.3 Ω and 6.8 Ω are available. Their powers are

p3.3=182⋅3.3(5+3.3)2≈15.5 W, p6.8=182⋅6.8(5+6.8)2≈15.8 W.

The 6.8 Ω load wins even though 3.3 Ω lies closer to 5 Ω. Compare the power values, not just resistance differences.

Check what is being varied

This theorem varies the load while the source network stays fixed. First remove the load and find the complete equivalent, retaining dependent sources. Then match, calculate the peak, and compare allowed loads if an exact match is unavailable. Maximum voltage occurs at an open output and maximum current at a short for a positive-resistance source; neither gives maximum load power. Zero source resistance has no finite interior peak for nonzero voltage, and negative source resistance does not meet the theorem's positive-resistance condition.

Key Takeaways

  • For a fixed positive-resistance source, match the adjustable resistive load to RTh.
  • At the match, load voltage and short-circuit current are each halved.
  • Compute pmax⁡=VTh2/(4RTh).
  • The derivative changes from positive to negative at the match.
  • Compare actual powers when choosing from allowed resistances.
  • Maximum power, maximum voltage, and maximum current occur at different loads.

4.3 Separate delivered power from efficiency

Maximum load power answers how much power a fixed source can deliver to an adjustable resistor. Efficiency asks what fraction of supplied power reaches that resistor. The load choice that answers one question does not answer the other.

Account for power in the equivalent

In the Thevenin model, the same current flows through source resistance and load resistance. Their powers are iL2RTh and iL2RL. Dividing load power by their sum gives

η=RLRTh+RL.

At a match, the two resistances dissipate equal powers, so transfer efficiency in the equivalent is 50%. With RL=4RTh, efficiency is 80%, but load power is only 16/25=64% of the peak. A larger load improves the fraction delivered while taking less absolute power once it is above the matching value.

Original-circuit losses need original currents

The equivalent's efficiency can differ from the efficiency of the original circuit. Circuit A supplies 16.2 W to a matched 5 Ω load at 9 V and 1.8 A. Its original 2 Ω output resistor adds a 3.6 V drop, putting node x at 12.6 V. The 24 V source therefore supplies

is=24−12.64=2.85 A,ps=24⋅2.85=68.4 W.

The original efficiency is 16.2/68.4≈23.7%. The extra internal branch current is hidden by the terminal replacement, so the model's 50% result cannot be assigned to the original network.

A fixed load changes the design question

If the load is fixed and you can reduce source resistance without changing the source voltage, reduce it. For an 18 V source feeding a fixed 10 Ω load, a 10 Ω source resistance delivers 8.1 W. Zero source resistance delivers 182/10=32.4 W. Adding source resistance to create a match would throw away available load power.

Power systems and battery equipment usually aim for small source resistance relative to the load, maintaining voltage and reducing loss. A 12 V battery modeled with 0.02 Ω internal resistance would drive 300 A into a matched 0.02 Ω load. The total resistance is 0.04 Ω, so iL=12/0.04=300 A. Each 0.02 Ω resistance dissipates 3002⋅0.02=1800 W. Permissible operation depends on current rating and discharge duration. With a 2.4 Ω load, current is 12/2.42≈4.96 A and efficiency is 2.4/2.42≈99.2%.

Matching is useful when maximum available power is the priority, such as extracting power from a weak signal source. A voltage-sensing task has a different aim: preserving voltage calls for a high input resistance. Decide whether you need load power, voltage fidelity, or economical energy use before choosing a resistance ratio.

Key Takeaways

  • Efficiency in the Thevenin model is RL/(RTh+RL).
  • Matching gives 50% transfer efficiency in that model.
  • Find original network efficiency from original supply power and load power.
  • With a fixed load and fixed source voltage, reducing source resistance increases delivered power.
  • Choose the resistance ratio to suit power delivery, voltage sensing, or efficiency.
5

Predict and measure loading

Connecting a circuit changes the circuit that feeds it. A divider, the input of a following stage, and a voltmeter can all be treated as a source feeding a finite resistance. That view predicts how much the output moves and suggests how to reduce the error. On the bench, measured voltage-current pairs can also work backward to reveal a source equivalent. Useful measurements need suitable loads, sufficient resolution, and operation within the source’s linear range.

5.1 How a connected load changes a source

A load draws current from the network that drives it. For a source with positive Thevenin resistance, that current creates a voltage drop inside the equivalent and lowers the output below its open value. The size of the change depends on the resistance ratio.

Replace a divider before loading it

A divider with upper resistor R1, lower resistor R2, and supply vs has

VTh=vsR2R1+R2,RTh=R1∥R2.

The voltage formula comes from the unloaded divider. The resistance formula comes from shorting the supply: both divider resistors then join the output node to the same rail. For two 10 kΩ resistors across 12 V, the equivalent is 6 V with 5 kΩ.

Connect 10 kΩ across the output. The load voltage becomes 6(10/(5+10))=4.00 V, a 33.3% drop. Direct analysis agrees: the lower resistor and load are parallel, giving 5 kΩ below the unchanged 10 kΩ upper resistor. Using the original equal-resistor divider result after attachment would miss the new branch.

Set a tolerable voltage drop

For a resistive load,

vL=VThRLRTh+RL,VTh−vLVTh=RThRTh+RL.

The same divider gives about 5.71 V with 100 kΩ and 5.97 V with 1 MΩ. Those are drops of about 4.8% and 0.50%. A load at least ten times the source resistance holds the drop to at most 9.1%; a hundred times holds it below 1%.

For a specified maximum droop fraction ϵ, solve the ratio before choosing a load:

RThRTh+RL≤ϵ⇒RL≥(1ϵ−1)RTh.

A 2% limit therefore needs a load at least 49 times the source resistance. The familiar ten-times rule would not meet that limit; its droop is about 9.1%.

A stiffer source costs current

Reducing the two divider resistors from 10 kΩ to 1 kΩ preserves the open voltage but reduces source resistance to 500 Ω. The 10 kΩ load then receives about 5.71 V. With no load, however, divider current rises from 0.6 mA to 6 mA and supply power rises from 7.2 mW to 72 mW. Lower output resistance reduces loading by drawing more standing current in this divider.

A following stage is also a load. A sensor equivalent of 50 mV with 1 kΩ feeding a 9 kΩ input delivers 50(9/10)=45 mV. Raising the input resistance reduces this loss. A buffer stage with high input resistance and low output resistance can separate the sensing and driving tasks.

Preserve current with the opposite ratio

For a Norton source, the load receives iL=INRN/(RN+RL). Keeping load current close to the rated source current requires a large parallel source resistance compared with the load. A 2 mA source with 100 kΩ parallel resistance supplies about 1.98 mA to 1 kΩ. Low series resistance helps a voltage source; high parallel resistance helps a current source.

Key Takeaways

  • A loaded divider needs the load branch included in the analysis.
  • The divider equivalent uses the unloaded voltage and the parallel combination of its resistors.
  • Voltage drop depends on source resistance compared with load resistance.
  • Lower divider resistance reduces sag but increases unloaded supply current.
  • A following stage’s input resistance loads the preceding stage.
  • A Norton current source needs parallel resistance much greater than the load to preserve current.

5.2 The meter is part of the circuit

A voltmeter takes current from the points it measures. An ammeter adds resistance to the path carrying the measured current. Their readings describe the circuit with the meter attached, so include the meter model when the added load matters.

Model a voltmeter as a resistance

A voltmeter is an ideal sensing element in parallel with its input resistance Rm. It loads the source equivalent just like any other resistor:

vread=VThRmRTh+Rm.

A typical digital multimeter has about 10 MΩ input resistance on DC voltage ranges; the actual value depends on the instrument and range. For a divider made of two 2 MΩ resistors across 10 V, VTh=5 V and RTh=1 MΩ. A 10 MΩ meter reads

5101+10≈4.55 V.

The 9.1% deficit comes from loading. Better display resolution would not remove it. An analog meter rated 20 kΩ/V on its 10 V range has Rm=200 kΩ and reads only about 0.83 V at this point.

Compare the meter with the source resistance

The fractional voltage error is RTh/(RTh+Rm). A 10 MΩ meter on the 6 V divider with 5 kΩ source resistance reads about 5.997 V, only about 0.05% low. The meter resistance is unchanged; the source resistance makes the difference.

An ideal voltmeter has infinite input resistance. A real meter approaches that behavior when its input resistance greatly exceeds the resistance seen at the measured points. On an analog meter, changing range changes input resistance. A reading that moves with range can therefore indicate loading.

When both resistances are known, undo the divider mathematically:

VTh=vreadRTh+RmRm.

For the 2 MΩ divider, multiplying the exact reading 50/11 V by 11/10 recovers 5 V. This reconstructs the unloaded voltage; it does not change the voltage present while the meter is connected.

Include an ammeter in series

An ammeter's internal resistance RA adds to the loop. With a 3 V source, 50 Ω source resistance, and 100 Ω branch, the undisturbed current is 3/150=20 mA. Inserting a 10 Ω ammeter changes it to 3/160=18.75 mA, a 6.25% reduction. This added effect is the meter's burden.

If the original total loop resistance is Rloop, inserting RA changes current from VTh/Rloop to VTh/(Rloop+RA). The fractional current reduction is RA/(Rloop+RA). Here it is 10/160=6.25%. Dividing by the old 150 Ω total would overestimate the error.

An ideal ammeter has zero resistance. Compare a real ammeter's resistance with the total loop resistance, not just the measured branch. A high-resistance voltmeter and a low-resistance ammeter reduce disturbance in their respective connections.

Key Takeaways

  • Treat voltmeter input resistance as a load across the measured terminals.
  • Voltage-loading error depends on meter resistance relative to source resistance.
  • Known resistances allow correction back to the unloaded voltage.
  • An ammeter adds series resistance and reduces current in a positive-resistance loop.

5.3 Recover an equivalent from measurements

A measured equivalent describes a real source near the conditions where you measured it. Begin with a high-input-resistance voltmeter and loads that stay within the source's ratings. Useful test loads produce a voltage change large enough to resolve without pushing the source into a different operating region.

Open voltage and one known load

Measure the open-circuit voltage with meter resistance much larger than the source resistance. Then connect a known load and measure its voltage. The load current is iL=vL/RL, and the source's internal voltage drop is voc−vL. Therefore,

RTh=voc−vLiL=RLvoc−vLvL.

A source reads 9.0 V open and 8.0 V across a 10 Ω load. The current is 8/10=0.8 A; the drop is 1.0 V. Thus RTh=1.0/0.8=1.25 Ω.

Two loads can replace the open reading

For each load, the terminal line gives v=VTh−RThi. Subtracting the two equations eliminates the unknown voltage intercept:

RTh=v1−v2i2−i1,VTh=v1+RThi1.

The same source gives 8.0 V with 10 Ω, so i1=0.8 A, and 7.2 V with 5 Ω, so i2=1.44 A. Its resistance is 0.8/0.64=1.25 Ω, and the recovered open voltage is 8.0+1.25⋅0.8=9.0 V. The current difference is in the reverse order from the voltage difference because increased delivered current lowers voltage for positive resistance.

Other measurement routes

If an adjustable load brings voltage to half its open value, its resistance equals the source resistance. Disconnect that resistor before measuring it with an ohmmeter. This half-voltage method follows directly from the voltage-divider ratio.

The open-voltage/short-current ratio also works when the source stays approximately linear across that whole range and the short current can be measured safely. A supply entering current limiting changes its terminal characteristic; two loads within voltage regulation give the relevant slope instead.

Bench safety: Do not short a battery, mains-powered circuit, or unprotected supply to measure its current; heating, fire, or damage can result. Use appropriately rated test loads and meters, and connect an ohmmeter only to a de-energized circuit. Direct resistance measurement requires safely replacing independent sources by their zero-value models and a network without powered dependent-source behavior.

Keep the measured range in view

Battery behavior changes with charge, temperature, and current. Measure near the intended operating current and treat the equivalent as an approximation over that range. Very similar load currents can make a small voltage difference hard to distinguish from measurement resolution; widely separated currents are useful only while both remain in the same linear operating region.

Key Takeaways

  • A known load gives current from its measured voltage and resistance.
  • Two voltage-current pairs give the source-line slope and voltage intercept.
  • Half the open voltage occurs at equal load and positive source resistance.
  • Use loads in the same approximately linear operating range.
  • Resolve the voltage change while respecting source, load, and meter ratings.

Thevenin and Norton Equivalents examples

5 Walkthroughs

1

Reduce a source network at its output

12 steps
Choose the port, find its open voltage, and redraw the deactivated network to find resistance.
  1. 1
    IntroductionKeep the load, simplify its source

    A changing load can force a fresh nodal solution every time. A Thevenin equivalent avoids that repeated work by describing the fixed network only at its two output terminals.

    You will keep track of what the external circuit sees, remove the load to find the source voltage, and then find the resistance seen at the same port. The fixed internal network becomes one voltage source and one series resistance.

  2. 2
    ExplanationChoose voltage and current directions

    Name the terminals a and b. Define voltage as v=va−vb and positive current as leaving a through the external circuit.

    The terminal line is

    v=VTh−RThi.

    For a positive resistance, current delivery causes a voltage drop. The equivalent keeps that line, so every attached load has the same terminal voltage and current. It does not keep the original internal branch currents.

  3. 3
    ChallengeSeparate terminal behavior from internal heating

    Two networks give the same voltage-current pair for every external load. Must they dissipate the same power internally? Explain.

    ---reveal---

    No. The port fixes the load’s voltage and current, but internal branches can draw additional source current. An unloaded divider still dissipates power even though its open Thevenin model carries no current. Original heating requires the original branch currents.

  4. 4
    ExampleOpen the output of Circuit A

    Circuit A uses a 24 V source feeding node x through 4 Ω. A 12 Ω resistor joins x to the bottom rail b, and a 2 Ω resistor joins x to terminal a.

    Remove the load from a and b. The 2 Ω terminal branch is open, so its current is zero. Its voltage drop is therefore zero, putting a at the same voltage as x. The 4 Ω and 12 Ω loop remains connected to the source.

  5. 5
    ExampleCalculate the voltage that remains

    Only the 4 Ω and 12 Ω resistors carry the unloaded divider current. The midpoint voltage is

    vx=24124+12=18 V.

    Since the terminal resistor drops no voltage, VTh=18 V with a positive relative to b. Including 2 Ω in the divider would give it current that cannot flow through the open terminal. The source stays active while finding this voltage.

  6. 6
    ChallengeRead between two nonzero node voltages

    An open port has terminal a at 3 V and terminal b at 8 V relative to the bottom rail. What source voltage should represent va−vb, and where is its positive side?

    ---reveal---

    The open voltage is 3−8=−5 V. Keep −5 V with the chosen polarity, or draw a positive 5 V source with its positive side toward b. Reporting 3 V would measure a relative to the rail instead of to b.

  7. 7
    ExplanationSet independent sources to zero

    For resistance, use a different circuit condition from the open-voltage calculation. Set an independent voltage source to 0 V by replacing it with a short. Set an independent current source to 0 A by replacing it with an open.

    Keep resistors, including source-model resistances. Dependent sources remain active because their outputs still change in response to a terminal signal; they need the controlled-source methods.

  8. 8
    ExampleLook into Circuit A after the short

    Shorting Circuit A’s 24 V source puts the far end of 4 Ω on the bottom rail. The 4 Ω and 12 Ω resistors now share both nodes:

    4∥12=3 Ω.

    Looking from a, the terminal 2 Ω comes before that parallel pair, so

    RTh=2+3=5 Ω.

    The terminal resistor contributes here even though its voltage drop was zero when the output was open.

  9. 9
    ChallengeFollow joined nodes before combining values

    An independent voltage source feeds a through 8 Ω, with 8 Ω directly from a to b. A current source also joins a and b. What is the resistance after deactivation?

    ---reveal---

    The voltage source becomes a short and the current source becomes an open. Both 8 Ω resistors are then across a and b, so RTh=8∥8=4 Ω. Adding them would miss the common end nodes created by the short.

  10. 10
    Key InsightA floating bridge still has a port resistance

    If neither terminal is ground, keep looking between the actual terminal pair. In the bridge with legs 6/12 Ω and 12/6 Ω, shorting the 12 V supply joins the top and bottom rails.

    Each terminal then sees 6∥12=4 Ω to the joined rail. From a to b, current passes through both 4 Ω combinations, giving 8 Ω. A resistor’s position on the page does not decide whether it is in series or parallel.

  11. 11
    ChallengeUse the two parameters together

    A network has 10 V open voltage. After independent-source deactivation, 2 Ω is in series with 6 Ω ∥ 3 Ω. What current will a 6 Ω load draw?

    ---reveal---

    The parallel pair is 2 Ω, giving RTh=2+2=4 Ω. Reconnect the 6 Ω load to the 10 V equivalent. The series loop current is 10/(4+6)=1 A. Both port parameters are needed; the open voltage alone does not determine loaded current.

  12. 12
    RecapKeep the three circuit conditions distinct

    Choose the terminal pair and reference directions first. With the external load removed and the network powered, find the signed open voltage. For a resistor/independent-source network, zero its sources and find the resistance looking back into the same port.

    Draw the equivalent voltage source with the matching polarity and reconnect the load. Its terminal results match the original; original internal losses still need the original circuit.

2

Build and transform Norton models

11 steps
Find current in the short, use current division, and combine source branches without losing their signs.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionPut current at the center of the model
  2. 2
    ExplanationAim the arrow toward the positive terminal
  3. 3
    ExampleFind the current in the actual short branch
  4. 4
    ChallengeSplit current into a new load
  5. 5
    ExplanationChange forms with Ohm’s law
  6. 6
    ExampleTransform Circuit A in useful stages
  7. 7
    ExampleCombine currents with direction signs
  8. 8
    ChallengeCheck the connection before transforming
  9. 9
    Key InsightRecognize the ideal-source limits
  10. 10
    ChallengeCombine first, then load the result
  11. 11
    RecapChoose the form that simplifies the next step
3

Solve a network while its source responds

13 steps
Track the controlling current through open, short, and test conditions, then interpret active resistance.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionA control equation changes the response
  2. 2
    ExplanationKeep the controlling reference visible
  3. 3
    ExampleSet up Circuit C with an open output
  4. 4
    ExampleFind the open voltage and control value
  5. 5
    ExampleShort the port and recalculate
  6. 6
    ChallengeLet the source follow its new control
  7. 7
    ExplanationApply a test with the entering-current sign
  8. 8
    ExamplePreserve Circuit C’s original control arrow
  9. 9
    Key InsightA zero output can still hide a resistance
  10. 10
    ExampleInterpret a negative resistance
  11. 11
    ChallengeTest a different controlled conductance
  12. 12
    ChallengeUse the two methods as a cross-check
  13. 13
    RecapKeep the gain, solve the control again
4

Find an operating point and choose a load

13 steps
Calculate load behavior, locate the power peak, and compare that peak with efficiency.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionDifferent load goals require different choices
  2. 2
    ExplanationInclude both series resistances
  3. 3
    ConnectionLet the load curve meet the source line
  4. 4
    ChallengeCompute a load’s three quantities
  5. 5
    ExplanationSee why power peaks between the extremes
  6. 6
    ExplanationUse the derivative to locate the maximum
  7. 7
    TipCompare the actual candidate powers
  8. 8
    ChallengeFind the match from port measurements
  9. 9
    ExplanationTrack the fraction delivered
  10. 10
    ExampleCheck original supply power separately
  11. 11
    ChallengeChoose source resistance when the load is fixed
  12. 12
    ChallengeMeet a power requirement efficiently
  13. 13
    RecapState the quantity being optimized
5

Predict measurement and loading errors

14 steps
Use source resistance to analyze dividers, meters, and measured voltage-current pairs.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionEvery connection becomes part of the circuit
  2. 2
    ExplanationReplace the divider before adding the load
  3. 3
    Key InsightChoose the resistance ratio for the signal
  4. 4
    ChallengePredict the effect of a following stage
  5. 5
    ConnectionA stiffer divider draws more standing current
  6. 6
    ExplanationInclude the voltmeter input
  7. 7
    ExampleAccount for series ammeter burden
  8. 8
    ChallengeUndo the loading divider
  9. 9
    ExampleUse one known load to find resistance
  10. 10
    ExampleInfer the line from two loaded readings
  11. 11
    TipKeep the measurements on one characteristic
  12. 12
    ChallengeRecover a source from fresh measurements
  13. 13
    ChallengeDecide whether the reading is close enough
  14. 14
    RecapModel the connection before trusting the reading

Thevenin and Norton Equivalents practice questions

40 Practice Questions in 4 sets

Set 1: Connect equivalent circuits to real loads10 Practice Questions

Question 1 of 10

Two networks have identical terminal voltage-current lines. What can be concluded about a 17 Ω resistor connected across either network?
  1. Its power equals each network’s internal loss.
  2. Its voltage and current are the same in both.
  3. Its current equals each network’s supply current.
  4. Its voltage equals each network’s open voltage.
Show answerHide answer
Answer: B
The shared terminal line and the same resistor relation determine the same operating point, so load voltage and current match. Equal load behavior does not require equal internal loss. The original networks can contain different internal currents that their two-terminal models do not describe.

Question 2 of 10

Two unloaded divider branches are across 15 V. The left has 2 kΩ above a and 3 kΩ below a; the right has 4 kΩ above b and 1 kΩ below b. What is the Thevenin voltage va−vb?
  1. 9 V
  2. −6 V
  3. 6 V
  4. 3 V
Show answerHide answer
Answer: C
The left midpoint is va=15(3/5)=9 V and the right is vb=15(1/5)=3 V above the rail. Their difference is 6 V. Reporting 9 V gives a relative to the rail, but the requested lower terminal is b, already 3 V above that rail.

Question 3 of 10

A 1.5 A Norton source has 12 Ω parallel resistance and drives a 4 Ω load. What is the load current?
  1. 0.375 A
  2. 1.125 A
  3. 1.5 A
  4. 4.5 A
Show answerHide answer
Answer: B
The divider gives iL=1.51212+4=1.125 A through the load. The remaining 0.375 A flows in the 12 Ω source resistor. Putting 4 Ω in the numerator finds that internal-branch current: current in one branch uses the other branch’s resistance in the numerator.

Question 4 of 10

A 16 V source feeds a through 4 Ω. Across a and b are 8 Ω and a CCCS drawing half the feed current from a to b. What are the Thevenin voltage and resistance?
  1. 8 V and 8/3 Ω
  2. 16/3 V and 8/3 Ω
  3. 8 V and 2 Ω
  4. 8 V and 4 Ω
Show answerHide answer
Answer: D
Open-circuit KCL sends half the feed current through 8 Ω, giving VTh=8 V. A short makes the feed 4 A and the CCCS takes 2 A, so RTh=8/2=4 Ω. Using 8/3 Ω removes the controlled source and combines only the resistors.

Question 5 of 10

A 20 V source feeds a through 5 Ω. A dependent source draws 0.25 times the feed current from a to b. With a short across a and b, what current flows through the short from a to b?
  1. 3 A
  2. 4 A
  3. 1 A
  4. 5 A
Show answerHide answer
Answer: A
The short makes feed current 20/5=4 A. The dependent branch takes 0.25⋅4=1 A, leaving 3 A for the external short. Reporting 4 A counts the supply current without subtracting the current returning through the controlled-source branch.

Question 6 of 10

A source has a 25 V Thevenin voltage and 5 Ω Thevenin resistance. What maximum power can an adjustable resistor receive?
  1. 125 W
  2. 62.5 W
  3. 31.25 W
  4. 6.25 W
Show answerHide answer
Answer: C
A matched 5 Ω load gives iL=25/10=2.5 A and pL=2.52⋅5=31.25 W. The 62.5 W value is power supplied by the ideal voltage source at that point. Half is dissipated in its 5 Ω series resistance and half reaches the matched load.

Question 7 of 10

A Thevenin model has 3 Ω source resistance and a 9 Ω load. What fraction of the ideal source power reaches the load?
  1. 25%
  2. 33.3%
  3. 50%
  4. 75%
Show answerHide answer
Answer: D
The same current flows through both resistances, so their powers are proportional to their values. The load receives η=9/(3+9)=75% of the ideal source power. The 50% result applies when load and source resistances are equal, which is not the resistance ratio here.

Question 8 of 10

A 16 V divider uses equal resistors. It must keep output droop below 2% with a 49 kΩ load and draw no more than 1 mA when unloaded. Available equal pairs are 8 kΩ, 10 kΩ, 20 kΩ, and 1 kΩ per resistor. What pair satisfies both requirements?
  1. 1 kΩ per resistor
  2. 8 kΩ per resistor
  3. 10 kΩ per resistor
  4. No available pair
Show answerHide answer
Answer: D
Droop below 2% requires source resistance below 1 kΩ, so each equal divider resistor must be below 2 kΩ. The current limit requires R1+R2≥16 kΩ, or at least 8 kΩ each. The 1 kΩ pair meets droop but draws 8 mA; no pair satisfies the conflicting bounds.

Question 9 of 10

A node has a 6 V Thevenin voltage and 2 MΩ source resistance. What does an 8 MΩ voltmeter read?
  1. 4.8 V
  2. 6 V
  3. 1.2 V
  4. 4 V
Show answerHide answer
Answer: A
The meter loads the node, so its reading is 682+8=4.8 V. The remaining 1.2 V drops across source resistance. A 6 V reading would need meter resistance effectively infinite compared with 2 MΩ; a finite 8 MΩ input still takes enough current to change this node.

Question 10 of 10

A source reads 12 V open and 9 V across an 18 Ω test load. What is its Thevenin resistance?
  1. 3 Ω
  2. 9 Ω
  3. 6 Ω
  4. 24 Ω
Show answerHide answer
Answer: C
The load carries iL=9/18=0.5 A, while source resistance drops 3 V. Dividing that drop by current gives RTh=3/0.5=6 Ω. Using 3 Ω confuses a voltage difference with resistance; the same drop can come from different resistances at different currents.
Set 2: Read the port and build an equivalent10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A 20 Ω resistor is parallel to a VCCS injecting 0.02vab A toward a from b. There are no independent sources. What is the port resistance?
  1. 20 Ω
  2. 100/3 Ω
  3. 100/7 Ω
  4. −100/3 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Independent sources have been zeroed. A 2 V test produces 0.25 A entering the network at the positive test terminal. What is its equivalent resistance?
  1. 0.125 Ω
  2. −8 Ω
  3. 0.5 Ω
  4. 8 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A Thevenin source of 14 V with 2 Ω drives a 5 Ω load. How much power does the load receive?
  1. 28 W
  2. 20 W
  3. 39.2 W
  4. 8 W
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A fixed source network has a 30 V open voltage and a 5 A short current. What adjustable load resistance receives maximum power?
  1. 6 Ω
  2. 5 Ω
  3. 30 Ω
  4. 3 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A sensor has 80 mV open voltage and 2 kΩ output resistance. It feeds an 8 kΩ input. What voltage reaches the input?
  1. 80 mV
  2. 20 mV
  3. 48 mV
  4. 64 mV
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A linear source has terminal equation v=15−3i, with voltage in volts and current in amperes leaving terminal a. What is its open-circuit voltage?
  1. 5 V
  2. 12 V
  3. 15 V
  4. 18 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

An 18 V source feeds x through 3 kΩ; 6 kΩ joins x to b, and 1 kΩ joins x to a. A 7 kΩ load is connected across a and b. What voltage does it receive?
  1. 8.4 V
  2. 9 V
  3. 7.2 V
  4. 12 V
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 9 V source connects through 6 Ω to terminal a. A 3 Ω resistor and an ideal 0.4 A source each connect across a and b. What resistance is seen from a and b when finding the equivalent?
  1. 9 Ω
  2. 0 Ω
  3. 3 Ω
  4. 2 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A Norton model has a 0.8 A source pointing from b toward a and a 15 Ω parallel resistor. What current flows through an external ideal short from a to b?
  1. 0 A
  2. 0.8 A
  3. 0.4 A
  4. 12 A
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

What Norton model represents a 21 V source, positive toward a, in series with 7 Ω?
  1. 3 A toward b, with 7 Ω parallel
  2. 147 A toward a, with 7 Ω parallel
  3. 3 A toward a, with 7 Ω parallel
  4. 21 A toward a, with 7 Ω parallel
Show answerHide answer

Save this lesson to see this answer.

Set 3: Keep controls, signs, and measurements consistent10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A 20 V source feeds two divider legs: 3 Ω above a and 6 Ω below a; 4 Ω above b and 12 Ω below b. A load would connect between a and b. What resistance does that load see?
  1. 7 Ω
  2. 5 Ω
  3. 25 Ω
  4. 10/3 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 6 V node connects through 2 kΩ to a. A 0.5 mA source injects current from b into a, and 4 kΩ connects a to b. With no external load, what is va−vb?
  1. 4 V
  2. 6 V
  3. 14/3 V
  4. 10/3 V
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

Two source branches share terminals a and b. One is 12 V in series with 4 Ω, positive toward a; the other is 9 V in series with 6 Ω, positive toward b. What is the combined Thevenin voltage from a to b?
  1. 3.6 V
  2. 10.8 V
  3. 7.2 V
  4. −3.6 V
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A 25 Ω resistor is parallel to a VCCS injecting 0.06vab A from b toward a. A 100 Ω load is attached, with no independent source anywhere. What load current is predicted by the linear equations?
  1. No unique finite current
  2. 0.5 A from a to b
  3. −0.5 A from a to b
  4. 0 A
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

An unexcited network has a 4 Ω resistor in series with a CCVS of value 6iT V, positive toward the resistor. Current iT enters at the resistor end. What is the port resistance?
  1. 2 Ω
  2. −2 Ω
  3. 4 Ω
  4. 10 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A 9 V Thevenin source with 30 Ω drives a nonlinear device that holds 3 V while conducting. What current does the device carry?
  1. 0.3 A
  2. 0.2 A
  3. 0.1 A
  4. 0.4 A
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 20 V source feeds node x through 10 Ω; 10 Ω connects x to b. A 5 Ω load connects x to b. What fraction of the original source power reaches the load?
  1. 50%
  2. 20%
  3. 16.7%
  4. 33.3%
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 5 mA Norton source with 40 kΩ parallel resistance must deliver at least 4.5 mA to a resistive load. What is the largest allowed load resistance?
  1. 40/9 kΩ
  2. 4 kΩ
  3. 360 kΩ
  4. 40 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A 4 MΩ voltmeter reads 3 V at an unloaded source output. That output has 2 MΩ Thevenin resistance. After the meter is removed, a 1 MΩ load is connected. What voltage does the load receive?
  1. 3 V
  2. 2 V
  3. 1 V
  4. 1.5 V
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A linear source gives 10 V across 20 Ω and 8 V across 8 Ω. What Thevenin equivalent fits both readings?
  1. 10 V with 4 Ω
  2. 12 V with 4 Ω
  3. 12 V with 2 Ω
  4. 14 V with 4 Ω
Show answerHide answer

Save this lesson to see this answer.

Set 4: Solve design choices and diagnose models10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A network has va−vb=−8 V with no load and has 2 Ω equivalent resistance. How should its positive-magnitude Thevenin voltage source be drawn?
  1. 8 V with positive side toward b
  2. 8 V with positive side toward a
  3. 4 V with positive side toward b
  4. 4 V with positive side toward a
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 15 V ideal source has a 100 Ω resistor directly in parallel with it. A 5 Ω resistor connects its positive node to terminal a; b is its negative node. What is the Thevenin resistance?
  1. 105 Ω
  2. 0 Ω
  3. 100/21 Ω
  4. 5 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 36 V source feeds x through 6 Ω. A 12 Ω resistor joins x to b, and 3 Ω joins x to a. What Norton current flows through a short from a to b?
  1. 6 A
  2. 24/7 A
  3. 4 A
  4. 8 A
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A linear one-port consists of an ideal 2 A current source alone. What equivalent form represents its terminal behavior?
  1. A finite Thevenin source with 0 Ω
  2. A Norton source with 0 Ω parallel
  3. A Norton source with infinite parallel resistance
  4. A finite Thevenin source with 2 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A 10 V source feeds a through 2 Ω. A 5 Ω resistor and a CCCS drawing 0.2ix connect a to b, with ix the feed current toward a. What is the correct Norton current and resistance?
  1. 5 A and 4/3 Ω
  2. 4 A and 10/7 Ω
  3. 4 A and 5/3 Ω
  4. 4.2 A and 100/63 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A source line passes through 18 V at 1 A delivered and 12 V at 3 A delivered. What current will a 9 Ω load draw?
  1. 2 A
  2. 1.75 A
  3. 3 A
  4. 1.5 A
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A fixed 10 V source has 4 Ω Thevenin resistance. Only 2 Ω, 3 Ω, 5.5 Ω, and 8 Ω loads are available. What load receives the most power?
  1. 2 Ω
  2. 5.5 Ω
  3. 3 Ω
  4. 8 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

An 18 V Thevenin source with 6 Ω must deliver at least 12 W to an adjustable load. Loads of 3 Ω, 6 Ω, 12 Ω, and 24 Ω are available. What load gives the highest transfer efficiency while meeting the power requirement?
  1. 3 Ω
  2. 6 Ω
  3. 24 Ω
  4. 12 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A 4 V source with 40 Ω source resistance feeds a 160 Ω branch. An ammeter with 20 Ω resistance is inserted in series. By what percentage does the branch current fall?
  1. 10%
  2. 9.09%
  3. 12.5%
  4. 8.33%
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A regulated supply reads 5 V open and 1 A when shorted in current limit. In voltage regulation it reads 4.98 V at 0.2 A and 4.94 V at 0.6 A. What Thevenin resistance describes that voltage-regulation range?
  1. 0.1 Ω
  2. 5 Ω
  3. 0.04 Ω
  4. 0.2 Ω
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

62 Key Terms, each with its definition

A

Ammeter
An ammeter measures current by being inserted in series with a branch, adding its own resistance to that current path.
The ammeter lowers the branch current from 20 mA to 18.75 mA when its added resistance is 10 Ω.
Ammeter burden
The ammeter burden is the added voltage drop or resistance introduced by the meter, which changes the current being measured.
Include ammeter burden in the total series resistance before predicting the indicated branch current.

B

Buffer stage
A buffer stage separates circuit stages using high input resistance to sense one stage and low output resistance to drive the next.
A buffer stage reduces loading of the divider while allowing it to supply a lower-resistance input.

C

CCCS
A CCCS is a current-controlled current source whose output current is a stated gain times a controlling current in the circuit.
A CCCS that draws half the feed current changes its current when the circuit’s output is shorted.
CCVS
A CCVS is a current-controlled voltage source whose output voltage is a gain times a controlling current; the gain has units of ohms.
A series CCVS producing three volts per ampere adds 3 Ω to the resistance seen by its control current.
Conductance
Conductance is current divided by voltage for a resistive relation, the reciprocal of resistance, measured in siemens.
Subtract the injected controlled-source conductance from the resistor conductance to find the port response.
Control gain
The control gain is the proportional factor relating a dependent source’s output to its controlling voltage or current.
A dependent source with a control gain of 0.5 keeps that gain even when its controlling current changes between conditions.
Controlling variable
A controlling variable is the specified voltage or current that determines a dependent source’s output through its control equation.
In one circuit, the controlling variable rises from 1.2 A to 3 A when the circuit’s open output is shorted.
Current division
Current division is the splitting of current between parallel paths according to their resistances, with more through a lower resistance.
Use current division to find the share entering the load rather than the internal Norton resistor.
Current limiting
Current limiting is a supply operating condition that restricts delivered current and changes its voltage-regulation terminal behavior.
Current limiting makes an open-voltage/short-current ratio unsuitable for the voltage-regulation resistance.

D

Dependent source
A dependent source sets its voltage or current from another circuit variable; a constant proportional gain makes its response linear.
Keep the dependent source active when the load is removed, shorted, or replaced by a test source.

E

Equivalent resistance
The equivalent resistance is the port resistance that sets the change in terminal voltage per change in delivered current.
If a port network holds a 2 Ω terminal resistor and a 3 Ω parallel pair, its equivalent resistance includes both.

H

Half-voltage method
The half-voltage method adjusts a resistive load until it receives half the open voltage, making it equal to positive source resistance.
In the half-voltage method, disconnect the adjusted load before measuring its resistance with an ohmmeter.

I

Ideal current source
An ideal current source maintains its specified current independently of voltage and has infinite parallel resistance in its source model.
An ideal current source alone has no finite Thevenin form that reproduces its complete terminal behavior.
Ideal voltage source
An ideal voltage source maintains its specified voltage independently of current and has zero series resistance in its source model.
An ideal voltage source alone has no finite Norton form because its short-circuit current is unbounded.
Input resistance
The input resistance is the resistance a circuit presents at its input terminals, acting as a load on the stage driving it.
A 9 kΩ input resistance reduces a 50 mV sensor with 1 kΩ output resistance to a 45 mV signal.
Internal loss
An internal loss is power dissipated inside the source network rather than delivered through its terminals to the external load.
In a resistive divider source, an internal loss can remain present even when the external load is disconnected.

K

Known-load method
The known-load method finds source resistance from open voltage and the voltage across a known load, using the resulting load current.
The known-load method gives 1.25 Ω from 9.0 V open and 8.0 V across a 10 Ω test resistor.

L

Linear operating range
A linear operating range is the interval of terminal conditions over which a source’s voltage-current behavior is approximately one straight line.
Choose both test loads within the same linear operating range when fitting a source equivalent.
Linearity
Linearity is the property that proportional changes and sums of excitations produce the corresponding changes and sums of responses.
Linearity lets the resistor and controlled-source network have a straight terminal voltage-current line.
Load power
The load power is the rate of energy delivered to the external load, equal to its voltage times its current under the passive sign convention.
A source whose open-circuit voltage is 18 V delivers a load power of 14.4 W to a 10 Ω load, well below what 18 V suggests.
Load resistance
The load resistance is the resistance of the external element receiving current from the source network at the selected terminals.
Changing load resistance leaves the fixed source equivalent intact but moves the operating point.
Loading effect
The loading effect is the change in a source’s output caused by current taken by a connected load or a following circuit stage.
The loading effect lowers a nominal 6 V divider output to 4 V when a 10 kΩ load is attached.

M

Maximum available power
The maximum available power is the greatest load power obtainable from a fixed positive-resistance source by adjusting a resistive load.
One source network has maximum available power of 16.2 W, even if a particular available resistor draws less from it.
Maximum power transfer theorem
The maximum power transfer theorem matches an adjustable resistive load to a fixed positive Thevenin resistance for greatest delivered power.
For a fixed source network with 4.8 Ω Thevenin resistance, the maximum power transfer theorem selects a 4.8 Ω load.
Measurement resolution
The measurement resolution is the smallest change a meter can distinguish in its reading, limiting how small a loading change can be resolved.
A test load should change the terminal voltage by well above the measurement resolution of the meter.
Meter sensitivity
A resistive analog voltmeter’s meter sensitivity, in ohms per volt, relates its input resistance to the full-scale voltage range.
With meter sensitivity of 20 kΩ/V, the 10 V range loads the circuit with 200 kΩ input resistance.

N

Negative equivalent resistance
A negative equivalent resistance is an active port response whose entering test current opposes the current expected for a positive resistor.
Negative equivalent resistance appears when the controlled source supplies more current than its parallel resistor takes.
Nonlinear load
A nonlinear load is an external device whose voltage-current relationship is not one straight proportional line over the range considered.
A nonlinear load can meet the linear source line at an operating point found from its device curve.
Norton current
The Norton current is the current through an external short between the port terminals, with a stated direction from a to b.
The Norton current is smaller than the supply current when another internal branch takes some current.
Norton equivalent
A Norton equivalent is a current source in parallel with a resistance that reproduces a linear network’s two-terminal behavior.
For one linear circuit, the Norton equivalent is a 3.6 A source in parallel with a 5 Ω resistance.
Norton resistance
The Norton resistance is the resistance placed in parallel with the equivalent current source, equal to the Thevenin resistance.
The Norton resistance remains 5 Ω when a circuit’s 18 V, 5 Ω Thevenin model is converted to Norton form.

O

One-port
A one-port is a network that connects to the external circuit through two terminals, with equal entering and leaving currents.
Treat the fixed sensor network as a one-port before attaching several different test loads.
Open-circuit voltage
The open-circuit voltage is the voltage between the unloaded output terminals while the network’s internal sources remain active.
The open-circuit voltage is measured before connecting the known resistor used for the load test.
Operating point
An operating point is a voltage-current pair satisfying both the source’s terminal relationship and the connected load’s relationship.
The operating point for a device holding 2 V on a 4 V, 8 Ω source is 2 V at 0.25 A.

P

Parallel connection
A parallel connection joins elements between the same two nodes, so every connected element has the same voltage across it.
In a circuit where a 4 Ω and a 12 Ω resistor meet the supply, shorting the supply creates a parallel connection between them.
Passive sign convention
The passive sign convention takes positive current as entering the positive-voltage terminal, so positive voltage-current product is absorbed power.
Use the passive sign convention for test current when taking the resistance ratio of voltage to current.
Polarity
Polarity specifies which end of a voltage is taken as positive and therefore fixes the sign of a stated voltage difference.
Keep the polarity a relative to b when moving from the open calculation to the equivalent drawing.
Power derivative
The power derivative describes how load power changes for a small change in load resistance while source parameters stay fixed.
The power derivative changes from positive to negative as the load passes through the matching resistance.

R

Reference node
A reference node is the circuit node assigned zero potential so that the other node voltages can be stated consistently.
Neither output terminal has to be the reference node; subtract their two node voltages to find the port voltage.
Resistive match
A resistive match is the condition in which load resistance equals positive source resistance when maximizing power from a fixed source.
At a resistive match, half the open voltage appears across the load and half across source resistance.

S

Series connection
A series connection places elements in a single current path without a branch at their shared junction, so they carry the same current.
After a network is reduced, its terminal resistor has a series connection with the parallel combination that remains.
Short circuit
A short circuit is an ideal zero-resistance connection that forces two connected points to have the same potential.
The short circuit across a and b puts zero voltage across the Norton model’s internal parallel resistor.
Source deactivation
Source deactivation sets independent sources to zero: voltage sources become shorts and current sources become opens.
In a bridge circuit, source deactivation joins the supply rails, changing how the resistors combine from the port.
Source line
The source line is the straight terminal voltage-current relationship, plotted using a voltage intercept and a slope set by source resistance.
On one circuit’s source line, a 10 Ω load operates at 1.2 A delivered and 12 V across the port.
Source resistance
The source resistance is the resistance in a source’s terminal model that describes how its delivered voltage changes with load current.
Reducing source resistance at fixed source voltage increases power into a fixed resistive load.
Source stiffness
Source stiffness describes how little a voltage source’s terminal voltage changes with load current, improving as its output resistance falls.
Smaller divider resistors improve source stiffness but also increase the unloaded current from the supply.
Source transformation
A source transformation replaces a voltage-source/series-resistor pair with a current-source/parallel-resistor pair, or the reverse.
When a circuit has two parallel supply branches, source transformation makes them easy to combine as signed current sources.
Superposition
Superposition finds a linear circuit’s voltage or current by adding the signed responses to individual independent sources.
Superposition checks a circuit’s open voltage by adding the separate contributions of its two 8 V sources.
Supply power
The supply power is the power furnished by a circuit’s actual source, found from its voltage and delivered current.
When a circuit’s actual supply power is 68.4 W at its matched load, use that figure to calculate its actual efficiency.

T

Terminal equivalence
Terminal equivalence means that two networks produce the same terminal voltage and current with the same external circuit connected.
Terminal equivalence keeps the load power unchanged even when the models’ internal losses differ.
Terminal voltage
The terminal voltage is the potential difference between the two chosen output terminals, with a stated reference polarity.
The terminal voltage is 4 V when a is at 8 V and b is at 4 V relative to the same rail.
Test source
A test source is a nonzero voltage or current applied at a deactivated network’s port to reveal its equivalent resistance.
After a circuit’s independent voltage source is shorted, a 1 A test source produces 4.8 V across its port.
Thevenin equivalent
A Thevenin equivalent is a voltage source in series with a resistance that reproduces a linear network’s behavior at its port.
Given a network’s 18 V, 5 Ω Thevenin equivalent, calculate a new load current without solving the full network.
Transfer efficiency
The transfer efficiency is the fraction of ideal source power reaching the load within the Thevenin model, set by its resistance ratio.
Transfer efficiency is 80% when the load resistance is four times the positive source resistance.
Two-load method
The two-load method finds a source equivalent from two measured voltage-current operating points without requiring an open reading.
The two-load method divides the voltage fall by the current rise, then recovers the open-voltage intercept.

V

VCCS
A VCCS is a voltage-controlled current source whose output current is a gain times a controlling voltage; the gain has units of siemens.
A VCCS injecting current toward a can offset the current drawn by a parallel resistor during a test.
VCVS
A VCVS is a voltage-controlled voltage source whose output voltage is a dimensionless gain times a controlling voltage.
Retain the VCVS control equation when applying KVL to the network with its independent sources zeroed.
Voltage divider
A voltage divider uses series resistors to obtain a fraction of a supply voltage, with its unloaded output taken across one resistor.
Replace the voltage divider by its Thevenin model before finding the voltage with a new load attached.
Voltage-loading error
The voltage-loading error is the fractional reduction from unloaded voltage caused by a voltmeter’s finite input resistance.
Voltage-loading error becomes significant when the meter resistance is comparable to source resistance.
Voltmeter
A voltmeter measures voltage across two points and has a finite input resistance in parallel with the measured circuit.
A 10 MΩ voltmeter reads about 4.55 V at the 5 V divider output with 1 MΩ source resistance.

Z

Zero-value source model
A zero-value source model is the replacement that enforces zero voltage for an ideal voltage source or zero current for a current source.
Use the zero-value source model of an open branch for any independent current source when deactivating a circuit.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started