RLC Circuits: Natural and Step Response
BeginnerLesson 8 of 8 in Electric Circuits 1 Course
What you will learn
- Recognize when a circuit is second order, find the initial and final values its solution needs, and write the differential equations of series and parallel RLC circuits.
- Find initial and final values in circuits with an inductor and a capacitorUse the continuity of capacitor voltage and inductor current, DC steady-state circuits and the element laws to find the two starting conditions and the final value of a switched RLC circuit.
- Write the differential equations of series and parallel RLC circuitsDerive the second-order equation of a source-free or step-driven series or parallel RLC circuit with KVL or KCL, and put it in the standard form that defines the neper frequency and the resonant frequency.
- Find initial and final values in circuits with an inductor and a capacitor
- Solve the characteristic equation, classify a circuit as overdamped, critically damped or underdamped, write the matching response form, and relate the resonant frequency and the damping to energy and to design choices.
- Solve the characteristic equation and classify the dampingFind the characteristic roots of an RLC circuit, decide from the neper and resonant frequencies whether it is overdamped, critically damped or underdamped, and find the resistance that gives critical damping.
- Write the response form for each damping caseWrite the overdamped, critically damped and underdamped response forms, set up the equations for their constants from the initial conditions, and describe how each case behaves over time.
- Relate the resonant frequency and the damping to energy and designExplain what the resonant frequency, the damped frequency and the damping describe physically, read them from a measured waveform, and choose element values for a required frequency or damping.
- Solve the characteristic equation and classify the damping
- Find the voltages and currents of source-free parallel and series RLC circuits in all three damping cases, from the stored energy at the switching instant.
- Find the natural response of a parallel RLC circuitUse the initial capacitor voltage and inductor current to find the shared voltage and the branch currents of a source-free parallel RLC circuit in each damping case.
- Find the natural response of a series RLC circuitUse the initial capacitor voltage and inductor current to find the loop current and the capacitor voltage of a source-free series RLC circuit in each damping case.
- Find the natural response of a parallel RLC circuit
- Find the complete response of series, parallel and other second-order circuits when a DC source is switched in, including circuits that start with stored energy and circuits switched more than once.
- Find the step response of a series RLC circuitFind the capacitor voltage and the loop current when a DC voltage source is switched into a series RLC circuit, and explain overshoot in the underdamped case.
- Find the step response of a parallel RLC circuitFind the inductor current and the shared voltage when a DC current source is switched into a parallel RLC circuit, including a source given as a voltage source with a series resistor.
- Solve general second-order circuits and switching sequencesFind the response of second-order circuits that are not simple series or parallel RLC circuits, including two-capacitor and op-amp circuits, and of circuits switched more than once.
- Find the step response of a series RLC circuit
- Check a computed response against the circuit, read its key features, and use RLC transients to explain and design real circuits.
- Check and interpret a computed responseVerify a second-order response with initial values, final values, circuit laws and energy, and read peak time, overshoot and settling from it.
- Use RLC transients in real circuitsExplain an ignition circuit, ringing in power wiring and the mechanical analogy with second-order models, and choose a resistance for a required overshoot.
- Check and interpret a computed response
RLC Circuits study guide
1Set up second-order circuit problems
A switch carries the stored capacitor voltage and inductor current into a new set of connections. Use separate circuit drawings to find the old DC state, the slopes immediately after switching and the final DC state where one exists. KCL and KVL then turn the connections into a second-order equation. Deriving both series and parallel equations shows why their resistance terms differ, even though their natural frequency has the same form.
1.1 Find initial and final values in circuits with an inductor and a capacitor
A switch changes the connections, but stored energy does not disappear at the switching instant. Start by finding the capacitor voltage and inductor current on each side of that instant. These values connect the old circuit to the new one.
Identify the stored quantities
A second-order circuit needs two independent energy-storage quantities. One inductor and one capacitor usually supply them. Two capacitors directly in parallel combine into one equivalent capacitor, so counting two components alone does not establish second order.
A natural response uses energy already stored when the independent sources are removed. A step response follows the sudden connection of a DC source and may also start with stored energy. Write for just before switching and for just after.
Carry values across the switch
For finite current and voltage, the element laws give
A voltage jump across a capacitor would require infinite current because . A current jump through an inductor would require infinite voltage because . Resistor current, capacitor current and inductor voltage can change suddenly. The derivatives of the two stored quantities can also change.
Choose voltage polarities and current arrows first. Under the passive sign convention, current enters the positive terminal of each element. At , represent the capacitor by its known voltage and the inductor by its known current, then use KCL and KVL to find
Work through a switched circuit
For a long time, a 12 V source and a 4 Ω series resistor feed two parallel branches: a 0.5 F capacitor, and a 0.5 H inductor in series with 2 Ω. The capacitor's top terminal is positive; inductor current points downward.
Before switching, DC steady state makes the capacitor an open circuit and the inductor a short. The conducting path has 6 Ω, so
Disconnect the source and its 4 Ω resistor, leaving the other three elements connected. Continuity gives 4 V and 2 A at . The inductor draws 2 A from the capacitor's top node. Thus the downward capacitor current is −2 A, giving
The inductor voltage is the node voltage minus the 2 Ω resistor drop:
The capacitor voltage was constant before switching but now has a negative slope. Continuity of a value does not require continuity of its slope.
Find the final circuit
For the DC final state, use the connections that exist after switching. Set derivatives to zero: the capacitor is open and the inductor is short. In this source-free resistive circuit, both stored quantities approach zero as the resistor dissipates the energy.
Keep the three circuit drawings distinct: the pre-switch DC circuit, the instantaneous circuit and the final DC circuit. Opening the only path of an inductor current or forcing a charged capacitor directly to a different ideal source voltage produces an impulsive ideal model. In practical switching circuits, provide a path for inductor current and avoid direct connections between unequal capacitor and source voltages.
Key Takeaways
- Carry and across a finite switch event; find their new slopes from the new circuit.
- A second-order solution needs a value and a first derivative for the chosen variable.
- Use open capacitors and shorted inductors for DC steady state.
- Choose reference directions before applying the element laws.
1.2 Write the differential equations of series and parallel RLC circuits
The differential equation turns the circuit connections into a prediction of how voltage or current changes. KVL is the simplest starting point for a series loop; KCL serves the same role for a parallel connection.
Derive the source-free equations
In a series RLC loop, let the shared current enter the capacitor's positive terminal. The voltage drops satisfy
Differentiate KVL and divide by the inductance:
In a parallel RLC circuit, let the top-node voltage be positive and direct all branch currents downward. Then
Differentiating KCL and dividing by the capacitance gives
Differentiation removes the integral in the storage-element law. It also removes its initial-value information, which is why the two starting conditions must be supplied separately.
Read the two parameters
Compare the equation with the standard form
| Connection | Damping coefficient | Undamped natural frequency |
|---|---|---|
| Series RLC | ||
| Parallel RLC |
The damping coefficient, also called the neper frequency, has units of inverse seconds. The resonant radian frequency has units of radians per second. The coefficient of the first derivative is twice the damping coefficient; the coefficient of the variable is the square of the natural frequency.
For parallel elements of 40 Ω, 100 mH and 10 μF, convert to 0.1 H and F. Then and . This gives
Putting those elements in series keeps the natural frequency but changes the damping coefficient to .
Keep the source term with a step
For a series voltage step, solve for capacitor voltage and substitute into KVL:
For a parallel current step, solve for inductor current using :
The source sets the DC final value: capacitor voltage approaches the voltage source, and inductor current approaches the current source. The natural roots come from the left side. Turning off independent sources means shorting voltage sources and opening current sources.
A Thévenin equivalent can turn the network feeding a series LC branch into a series RLC problem. A Norton equivalent serves a parallel LC pair. The equivalent resistance must belong to that actual connection; a mixed circuit needs its own equation. Check units before solving: , and are times, so their inverses have the required frequency units.
Why a step-driven current can have a homogeneous equation
For a constant series source, differentiating gives a zero right-hand side for times after switching. The loop-current equation is then homogeneous, even though the source remains connected. Its effect enters through the starting slope. For a 24 V step into 0.2 H from rest, KVL gives . Starting with both zero current and zero slope would incorrectly erase the applied step. Solving for capacitor voltage keeps the constant source term visible instead; either variable gives the same circuit behavior when its own conditions are used.
Key Takeaways
- Use KVL for a series loop and KCL for parallel branches.
- Read and from the normalized equation.
- Use in series and in parallel.
- A DC source sets the final value without changing the natural roots of the fixed circuit.
- Reduce a network only when its actual terminals permit the matching equivalent.
2Predict the type of response from the characteristic equation
The characteristic roots describe the response before any constants are fitted. Their real parts set decay rates, and imaginary parts produce ringing. Compare damping with natural frequency to choose the form, then fit its value and slope at the switching instant. Root sums and products provide quick arithmetic checks, while peak spacing and amplitude ratios let you work backward from a measured waveform to the circuit parameters.
2.1 Solve the characteristic equation and classify the damping
The same component types can produce a smooth decay or a ringing waveform. The characteristic equation tells you which response forms the circuit can support before you fit any starting values.
Find the characteristic roots
Try an exponential in the source-free equation. Each derivative contributes a factor of , giving
A nonzero response therefore needs the characteristic equation
Its roots are
The root has units of inverse seconds so that the exponent is dimensionless. Negative real parts produce decay. For passive series and parallel RLC circuits with positive resistance, both roots have negative real parts.
Classify the result
| Case | Parameter comparison | Root structure |
|---|---|---|
| Overdamped | Two different negative real roots | |
| Critically damped | One negative real root repeated twice | |
| Underdamped |
Here is the imaginary unit and is the damped radian frequency. It sets the rate of ringing. The damping ratio states the same comparison without units: above 1 is overdamped, equal to 1 is critical, and between 0 and 1 is underdamped.
Compare angular-frequency values consistently. Dividing the natural frequency by gives hertz, but that hertz value is not the quantity to compare with the damping coefficient.
Change one resistor
Take parallel elements with and . Their natural frequency is 1000 rad/s.
At 40 Ω, the damping coefficient is 1250 inverse seconds. The square root in the root formula is 750, so the roots are −500 and −2000 inverse seconds. Their sum is −2500 and their product is , matching and .
At 50 Ω, the damping coefficient is 1000 inverse seconds, giving a repeated root of −1000. At 62.5 Ω it is 800 inverse seconds; the damped frequency is 600 rad/s, giving roots . Raising the parallel resistance has moved the circuit toward ringing.
Choose critical resistance
Set the damping coefficient equal to the natural frequency and solve for resistance:
For the values above, , so the critical resistances are 200 Ω in series and 50 Ω in parallel. Series resistance above its critical value is overdamped; parallel resistance below its critical value is overdamped.
At the lossless limit, series resistance is zero or the parallel resistor is open. Then and the roots are . Energy moves between the storage elements without an exponentially shrinking amplitude.
Key Takeaways
- The characteristic roots satisfy .
- Compare with to choose the damping case.
- Underdamped roots have real part and imaginary parts .
- The critical resistance depends on whether the elements are in series or parallel.
- Check root sum and product .
- The lossless LC limit has imaginary roots and sustained oscillation.
2.2 Write the response form for each damping case
A response form describes the shapes allowed by the roots. Its two constants select the one curve that meets the circuit's starting value and starting slope. For a circuit that settles under a DC input, include the final value before fitting either constant.
Match the form to the roots
Let and . The final value is , zero for a damped source-free response.
| Case | Complete response |
|---|---|
| Overdamped | |
| Critically damped | |
| Underdamped |
The repeated-root case needs the factor of time. Two constants multiplying the same exponential would combine into one constant and could not meet two independent initial conditions.
Fit a value and a slope
Substitute zero into the form, then differentiate and substitute zero again:
- Overdamped: and .
- Critical: and .
- Underdamped: and .
For an underdamped response with final value 5 V, starting value 2 V, starting slope 4 V/s, damping coefficient 2 inverse seconds and damped frequency 3 rad/s, . The slope equation gives , so . Thus
The first constant is −3 V, not 2 V: it measures the displacement from the final value. The product rule matters in the slope equation because both the exponential and the sinusoidal part change.
Read the decay and ringing
In an overdamped response, the root closer to zero decays more slowly. For roots −500 and −2000 inverse seconds, the time constants are 2 ms and 0.5 ms. The slow term controls the late response when its coefficient is nonzero.
An underdamped response has amplitude envelope around its final value, where . Its period is . Use radians in the sine and cosine. At , the exponential factor is about 0.018; this supplies a common rough 2% settling estimate, not an exact settling calculation for every set of constants.
Critical and overdamped responses do not ring. They may cross their final value once if their initial conditions require it. Adding damping beyond critical can make the dominant decay slower: with fixed natural frequency 1000 rad/s, increasing the damping coefficient from 1000 to 1250 inverse seconds produces a slow root of −500.
For the ideal lossless case use . The constant is an equilibrium offset; a persistent oscillation generally has no final value.
Work a critical fit without dropping the product rule
Suppose a voltage has repeated root −2 inverse seconds, final value 8 V, initial value 3 V and initial slope 1 V/s. First write . At zero, . Differentiation gives
The slope condition is , so and
The coefficient −9 V/s is not the initial slope: the exponential contributes another +10 V/s at zero. Multiplying that coefficient by time makes it a voltage, so the terms inside the parentheses have matching units. The fitted response starts below its final value and initially rises, as its positive starting slope requires.
Key Takeaways
- Include the final value before applying the initial conditions.
- The repeated-root form needs as well as .
- Fit the first derivative as well as the value.
- The root closest to zero controls the late overdamped response when present.
- Ringing frequency and envelope decay are separate features.
2.3 Relate the resonant frequency and the damping to energy and design
Natural frequency describes energy exchange; damping describes energy loss. Keeping these roles separate helps you interpret a measured trace and select element values for a desired response.
Follow the energy
The capacitor stores electric energy . The inductor stores magnetic energy . In an underdamped response, energy passes back and forth while the resistor converts some of it to heat. Its absorbed power is .
The ideal LC exchange rate is
For 100 mH and 10 μF, the natural frequency is 1000 rad/s, or about 159.2 Hz. The lossless period is about 6.28 ms. Damping lowers the actual ringing frequency to . At a damping ratio of 0.1, this is about 99.5% of the natural frequency; near critical damping, the ringing frequency falls toward zero.
See how the elements change the response
| Change with other elements fixed | Series RLC | Parallel RLC |
|---|---|---|
| Increase resistance | Increases damping coefficient | Decreases damping coefficient |
| Increase capacitance | Lowers natural frequency; raises damping ratio | Lowers natural frequency; lowers damping ratio |
| Increase inductance | Lowers natural frequency; lowers damping ratio | Lowers natural frequency; raises damping ratio |
These directions follow from
A larger series resistance absorbs more power at a given loop current. A larger parallel resistance absorbs less power at a given node voltage. The same word, resistance, therefore has opposite damping effects in the two connections.
Design a frequency or damping ratio
For a series circuit with 0.2 H and 20 μF, the natural frequency is 500 rad/s. A target damping ratio of 0.6 needs . Therefore
Its damped frequency is . To choose inductance for a separate target of 2000 rad/s with 0.5 μF, rearrange the frequency equation:
Extract parameters from a trace
Measure the spacing between successive peaks on the same side of the final value. This is a full damped period. Measure both peak heights relative to that final value, calling them and . Then
For a 2 ms spacing and heights of 5.0 V and 2.0 V, these give about 3142 rad/s, 458 inverse seconds and 3175 rad/s. A maximum-to-minimum spacing is only half a period. Measuring absolute voltages from zero in a step response also gives the wrong decay ratio when the final voltage is nonzero.
Key Takeaways
- describes lossless exchange; describes damped ringing.
- The resistor turns stored energy into heat.
- Increasing either storage element lowers .
- Series and parallel resistance change damping in opposite directions.
- Measure a full period between same-side peaks.
- Measure peak amplitudes from the final value before finding their ratio.
3Find the natural response of RLC circuits
A source-free RLC circuit runs on the energy present when its independent sources are removed. In parallel, the shared voltage is a convenient starting variable; in series, the shared current often is. Work through both connections with signed starting slopes and all three damping cases. Recover branch currents or capacitor voltage from the solved variable, and use the element laws to check whether a negative coefficient or a voltage reversal is physically consistent.
3.1 Find the natural response of a parallel RLC circuit
A source-free parallel circuit has one shared voltage. Solving for that voltage makes the resistor and capacitor currents easy to recover, and KCL then supplies the inductor current.
Set the starting slope
Take the voltage positive at the top node and all branch currents downward. With initial voltage and downward inductor current , KCL gives
Therefore . An upward initial inductor current enters this expression as a negative value. The resistor current must be included even when the inductor starts with zero current.
Solve an overdamped example
Connect 40 Ω, 100 mH and 10 μF in parallel, with 12 V initially across the capacitor and no initial inductor current. The starting slope is
The damping coefficient is 1250 inverse seconds and the natural frequency is 1000 rad/s, giving roots −500 and −2000 inverse seconds. With a zero final voltage, write
The initial conditions become and . Substituting gives , so
The negative coefficient is needed to meet the initial slope. The voltage crosses zero at and later returns to zero from below. This single crossing is compatible with overdamping; repeated oscillation is not.
Change the damping case
Keep the same storage elements and initial conditions. At 50 Ω the root is repeated at −1000 inverse seconds, while the initial slope is −24 000 V/s. Thus and , giving
At 62.5 Ω the roots are and the starting slope is −19 200 V/s. Fit and , obtaining
The envelope amplitude is , and the damped period is about 10.5 ms. Changing the resistance changed the initial resistor current as well as the roots, so the starting slope had to be recalculated each time.
Recover and check the branch currents
Use and , then . In the underdamped example, differentiation gives
The resistor current is , so the inductor current is . It starts at zero as required. Always check the voltage's initial value, its initial slope and its final value independently; fitting only the initial voltage leaves one constant undetermined.
Key Takeaways
- For downward branch currents, .
- Calculate the slope again when resistance changes.
- A single zero crossing can occur without ringing.
- Recover branch currents with the element laws and KCL.
3.2 Find the natural response of a series RLC circuit
A source-free series circuit has one shared current. The capacitor's initial polarity determines whether that current initially grows in the chosen direction or decreases, so write a signed KVL equation before using a memorized slope formula.
Keep current and voltage references together
If current enters the capacitor's positive terminal, the passive voltage drop is and KVL is . Thus
For a discharge example, it is often easier to direct current out of the capacitor's positive terminal. Calling its positive-terminal voltage , the equations become
Neither convention changes the circuit. It changes the signs assigned to its variables.
Find an underdamped discharge current
A 20 μF capacitor initially holds 100 V and is connected to 120 Ω and 0.2 H with zero initial current. Use discharge current leaving the capacitor's positive terminal. The parameters are , and .
At the first instant, the resistor drop is zero and the inductor has 100 V. Therefore . In
the initial current sets and the slope sets . Hence
The capacitor voltage starts at 100 V with zero slope because the initial current is zero. Its own constants give
Differentiating this voltage and multiplying by the negative capacitance recovers the discharge current. The minus sign follows from the chosen arrow.
Solve the other damping cases
With the same initial energy but 250 Ω, the roots are −250 and −1000 inverse seconds. The current conditions are and . Thus
This pulse reaches about 0.315 A at and then decays without reversing. In the underdamped case, differentiating the sine-exponential current gives its first peak at , about 0.499 A. The current peak is not generally half a ringing period.
For a critical example, take 0.5 H, 0.5 F and 2 Ω, with discharge current 2 A and capacitor voltage 4 V initially. KVL gives zero current slope. The repeated root is −2 inverse seconds, so and :
Series current and parallel voltage obey equations of the same form. This duality lets you reuse the root and constant-fitting method, while keeping the connection-specific damping formula and initial conditions.
Key Takeaways
- In a series loop, use .
- The initial current slope comes from signed KVL.
- For discharge current leaving the positive terminal, .
- Fit capacitor voltage and loop current with their own initial conditions.
- Find a current peak by differentiating the current response.
4Find the step response of RLC circuits
A DC step adds a driven response to the circuit's natural behavior. The final value depends on the source and the DC connections, while the roots govern the transient. Fit series and parallel responses first, then extend the method to mixed networks, separate capacitor states and a second switching event. Some ideal active circuits keep growing and need a driven solution with no final-value offset.
4.1 Find the step response of a series RLC circuit
When a DC voltage source is connected to a series RLC circuit, the capacitor eventually charges to the source voltage. The transient describes how it gets there, including any overshoot or initial stored energy.
Add the final voltage
Take the loop current into the capacitor's positive terminal. The DC final current is zero because the capacitor is open in steady state. With no resistor or inductor drop, . Therefore write the complete response as the source voltage plus the matching natural form.
Continuity gives and . The voltage slope is . Starting at rest means both values are zero, including the slope; the source voltage initially appears across the inductor.
Fit an underdamped voltage step
Connect 24 V to 120 Ω, 0.2 H and 20 μF at rest. The parameters are and . Write
At zero, . Differentiating at zero gives . Therefore
The charging current is obtained by differentiation:
It starts and ends at zero, even though the source remains connected. A final current of would ignore the capacitor in the DC circuit.
Explain the overshoot
The first capacitor-voltage maximum occurs when the charging current first returns to zero, at . At that instant,
The inductor keeps current flowing after the capacitor reaches 24 V, so additional charge raises its voltage above the supply. The relative overshoot is about 9.5%. For this voltage step from rest, its fraction is . An initially charged capacitor changes the constants and the peak; use the actual fitted response in that case.
Compare critical and overdamped charging
With 250 Ω, the roots are −250 and −1000 inverse seconds. The starting conditions give and . The result is
At the critical resistance of 200 Ω, . With and ,
Both rise without overshoot from rest; the critical choice settles faster than the 250 Ω choice.
If the original underdamped circuit instead starts at 6 V with zero current, fit the displacement . The slope equation gives a sine coefficient of −13.5 V. The roots and final voltage stay the same, while the transient becomes .
Key Takeaways
- The final capacitor voltage is and the final loop current is zero.
- Fit the transient to and .
- Inductor current can charge the capacitor above the supply voltage.
- Peak time applies to the standard underdamped capacitor-voltage step from rest.
- Stored initial energy changes constants without changing the fixed circuit's roots.
4.2 Find the step response of a parallel RLC circuit
A current source connected to a parallel RLC circuit eventually sends all its current through the inductor. Solve for inductor current first: its initial value is continuous and its final value is the source current.
Choose the variable and conditions
Let the source inject current into the top node, with resistor, inductor and capacitor currents downward. The shared voltage is positive at the top. In DC steady state the inductor is a short, so and .
The initial conditions for the inductor-current equation are
The roots come from and . Notice that the starting current slope depends on the capacitor's voltage, not directly on the newly connected source current.
Work an overdamped current step
A 30 mA source feeds parallel elements of 40 Ω, 100 mH and 10 μF, all initially at rest. The roots are −500 and −2000 inverse seconds. In milliamperes,
The zero starting current gives , and the zero slope gives . Solving yields
To find the shared voltage, convert current to amperes before multiplying its derivative by 0.1 H:
Voltage starts at zero, rises during current transfer to the inductor, and returns to zero. Using 30 mA times 40 Ω as the final voltage would treat the resistor as the only current path.
Change resistance and fit again
At 62.5 Ω, the damping coefficient is 800 inverse seconds and the damped frequency is 600 rad/s. The same initial conditions give coefficients −30 mA and −40 mA:
Its first peak is at and is about 30.45 mA. This standard inductor-current step from rest has about 1.5% overshoot. At the critical resistance of 50 Ω, the repeated-root solution is
The numerical coefficient multiplying time has units of milliamperes per second; seconds inside the parentheses keep all terms in milliamperes.
Convert a voltage-fed LC pair
A voltage source with a series resistor feeding a parallel LC pair has a Norton equivalent. A 12 V source through 400 Ω becomes a 30 mA source in parallel with 400 Ω. With 100 mH and 10 μF, the damping coefficient is 125 inverse seconds, the damping ratio is 0.125 and the damped frequency is about 992 rad/s.
Keep the equivalent resistor in the parallel circuit when calculating the damping. The ideal source conversion changes the drawing, not the terminal behavior. After fitting the inductor current, recover voltage from and the remaining currents from and . Their sum with the inductor current must equal the source current.
Key Takeaways
- A parallel current step ends with and shared voltage zero.
- Use the initial slope .
- Convert current units before using .
- A voltage source and series resistor feeding parallel LC can be converted to Norton form.
4.3 Solve general second-order circuits and switching sequences
Two storage elements do not guarantee a simple series or parallel RLC connection. For a mixed network, derive the equation from its actual nodes and loops. The root-based solution method still works after that equation is known.
Eliminate an internal variable
A 10 V step feeds a 1 Ω resistor and 1 H inductor in series, followed by a node with 0.25 F and 4 Ω in parallel to return. Let be the node voltage and the current entering it. KCL and KVL give
Differentiate the KCL expression and substitute both current expressions into KVL:
or . The characteristic roots are . The final voltage is the DC divider value . Starting at rest gives zero voltage and zero slope, so
Both resistors affect this equation. In general, this arrangement gives
Neither simple RLC damping formula is sufficient here. Keep dependent sources active while finding the natural equation; only independent sources are turned off.
Recognize other second-order circuits
A two-stage RC ladder has a source feeding a first node through a resistor, then a second node through another resistor. Each node has its own capacitor to return. The separate node voltages prevent combining the capacitors.
For both resistors at 1 kΩ and both capacitors at 1 μF, KCL at the second node gives . Substitute into the first node equation to obtain
The roots are about −382 and −2618 inverse seconds. A passive resistor-capacitor network has real natural roots; when its capacitors have resistive discharge paths, those roots are negative. It decays without ringing even though it is second order.
Two ideal inverting op-amp integrators in cascade also give second order. Each obeys . With both time constants 0.1 s, a 0.2 V step from rest gives a first output of and a second output of . The characteristic equation is ; there is no settled DC output. A real op amp saturates at its output limit. Resistors across the integrating capacitors produce negative real roots, and overall feedback can change the damping case.
Carry the state through another switch
For a second switch at , evaluate both stored quantities at the end of the first interval. They become the starting values of the second interval, whose local time is . Recalculate derivatives using the new connections.
For the series response with 20 μF, at 2 ms the capacitor holds about 5.67 V and the charging current is
If the source is then replaced by a short while the 250 Ω resistor and 0.2 H inductor remain in the loop, stays about 3770 V/s. The new current slope is . The new final voltage is zero; fit its two exponential constants using these new conditions and write their exponents in . Resetting the stored values to zero would discard the energy present at the second switch.
To complete that second interval, use . The inherited state gives V and V/s. Solving gives approximately V and V. Thus
Although the source is gone, this voltage initially continues upward because positive inductor current is still entering the capacitor. The new negative current slope slows that charging current; it does not force the capacitor voltage to start falling immediately.
Key Takeaways
- Derive a mixed circuit's equation before reading its damping parameters.
- Two separate capacitor states can make an RC circuit second order.
- Ideal integrators may have no DC final value.
- Dependent sources remain active in the natural-equation calculation.
- At a later switch, preserve the stored values and recompute slopes.
- Use local time in the later interval.
5Check and apply second-order responses
A plausible curve still needs to pass physical checks. Compare its initial value, slope, final state, units and roots with the circuit, and use energy to test a source-free discharge. Then read peaks and settling with the correct response variable in mind. Apply the same ideas to ignition pulses, supply wiring and a mechanical model, including choosing resistance for an overshoot limit.
5.1 Check and interpret a computed response
A response formula must fit the circuit, not just look like a decaying curve. A few independent checks can locate a wrong sign, a missing final value or a unit conversion before it affects the rest of a solution.
Test the conditions and roots
Substitute zero into the response and into its derivative. These must match the starting value and slope found from the circuit. For a circuit that settles under DC excitation, take the long-time limit and compare it with the final DC drawing. Then check that the exponential rates and ringing frequency match the characteristic roots.
For , the starting value is zero. The derivative at zero is . The long-time limit is 24 V. The roots have sum −600 and product 250 000, matching the characteristic equation .
Check units term by term. Exponents and trigonometric arguments must be dimensionless. In , time is in seconds; 2 ms gives an exponent of −1.6. In a critical form, the coefficient multiplying time has units of the response per second.
Check the circuit laws
For a series charging current, use , and . Their signed voltage sum must equal the source at every instant. In a parallel circuit, use , then calculate the resistor and capacitor currents and verify KCL.
The initial inductor voltage of a series voltage step from rest equals the source voltage. A zero initial loop current therefore does not mean every voltage is zero. A transient simulator with the same connections, initial states and reference directions gives another comparison. Match those settings before diagnosing a disagreement as a mathematical error.
Use energy as an independent check
In a source-free circuit, the resistor's absorbed energy must account for the decrease in stored energy. For 10 μF initially at 12 V with no inductor current,
For the parallel 40 Ω response , integrating from zero to infinity gives 0.72 mJ. A negative voltage during part of the discharge does not make resistor power negative: power contains the square of voltage.
Read peaks and settling correctly
For an underdamped series capacitor-voltage step or parallel inductor-current step, each starting at rest,
The overshoot fraction multiplies the step size. The estimate gives a rough 2% settling time; inspect the actual response for a specified tolerance. Initial stored energy changes the peak conditions. For another quantity, differentiate that quantity's response and find where its derivative is zero.
Repeated crossings of the final value reveal ringing. One crossing can also occur in a critical or overdamped natural response, so classify it from its roots. Keep full precision through the constant fitting; early rounding can create a false failure of an otherwise exact initial-condition check.
Key Takeaways
- Check the value, slope, final state, roots and units independently.
- Reconstruct related quantities and verify KCL or KVL.
- Source-free resistor dissipation must equal the lost stored energy.
- Apply standard peak formulas only to the matching step response from rest.
- Use seconds and radian mode when evaluating a response.
5.2 Use RLC transients in real circuits
An RLC model explains both useful voltage pulses and unwanted ringing. The same equations also describe a mass, spring and damper, so the circuit methods connect directly to mechanical motion.
Follow a classic ignition pulse
In a classic ignition circuit, a 12 V battery builds current in the coil's primary winding while a switch is closed. A capacitor sits across the switch. Opening the switch redirects the winding current into that capacitor, creating a lightly damped RLC transient. Transformer action then raises the primary pulse to the much higher secondary voltage used by the spark plug.
For primary resistance 3 Ω and inductance 6 mH, the settled current before opening is . With 0.25 μF across the switch,
The damping ratio is about 0.01. Initially the inductor stores . A first energy estimate puts that energy into the capacitor in roughly a quarter period, about 61 μs:
The primary coil voltage is about 610 V in this model. The energy estimate neglects the small loss during the first transfer; it explains the scale of the pulse. The capacitor also gives the coil current a path while the contacts separate, limiting the rate of voltage rise and reducing arcing.
Recognize ringing in supply wiring
Supply wiring has inductance. Together with a capacitor near a load, it can form an underdamped input circuit. For 1 μH, 10 μF and 0.05 Ω in series, the natural frequency is about 316 000 rad/s, or 50 kHz, and the damping ratio is about 0.079.
For a supply-voltage step applied from rest, the capacitor-voltage overshoot is about 78%. A load-current change can also excite ringing, but its peak must be found from that particular response. The critical series resistance for these storage values is about . Added resistance reduces ringing while also dissipating power; above critical damping it slows the dominant decay.
Choose resistance from an overshoot target
For the standard underdamped voltage step from rest,
Solving for the required damping ratio gives
A 5% overshoot limit means , giving a minimum damping ratio of about 0.69. With 0.2 H and 20 μF, select at least . This is total series resistance, including resistance already in the circuit. Critical and overdamped choices also avoid overshoot for this step from rest, but may settle more slowly.
Map the mechanical model
The series RLC equation in charge is . Compare it with the mass-spring-damper equation . Inductance corresponds to mass, resistance to the damping coefficient and inverse capacitance to spring stiffness. Current corresponds to velocity because each is the derivative of the corresponding displacement variable. This shared equation explains why both systems can ring, reach critical damping or return with two real decay rates.
When choosing a practical resistor, include the resistance of the existing path. If it already totals 32 Ω in the 0.2 H, 20 μF example, choosing 140 Ω total needs an added 108 Ω. The resulting damping ratio is . Substituting it into the overshoot expression gives about 4.6%, meeting the 5% limit for the capacitor-voltage step from rest. Adding the whole 140 Ω would instead produce 172 Ω total and a different response. Rounding a minimum design value upward and checking the resulting response keeps the chosen component consistent with the requirement.
Key Takeaways
- An inductor's stored energy can produce voltages much larger than the DC supply.
- A switch capacitor provides a temporary path for coil current.
- Supply-voltage steps can excite ringing in wiring inductance and load capacitance.
- An overshoot limit sets a minimum damping ratio for the standard step from rest.
- In the mechanical analogy, maps to mass and maps to stiffness.
RLC Circuits examples
1Set up the circuit before solving
11 steps
- 1IntroductionStart with what the switch preserves
A switch creates a new circuit, but the new response starts with energy already present. Find the capacitor voltage and inductor current first, then use the new connections to calculate their rates of change. These two starting quantities lead to a second-order equation and its two initial conditions.
- 2ExplanationCheck for two independent stored quantities
A second-order circuit needs two independent stored quantities. An inductor and capacitor usually provide them. Two capacitors directly in parallel share one voltage and combine into one equivalent capacitor, so counting parts alone does not establish the order.
- 3ExampleFind the state before switching
A 12 V source through 4 Ω feeds a capacitor in parallel with a branch containing an inductor and 2 Ω. The source has been connected for a long time. The capacitor is open and the inductor is short in DC steady state.
The capacitor is across the 2 Ω branch, so its top-positive voltage is 4 V. These are the stored values that pass into the new circuit.
- 4ExampleCalculate the slopes after switching
Disconnect the source and its 4 Ω resistor. Let the remaining capacitor be 0.5 F and the inductor 0.5 H. The downward inductor current remains 2 A and the capacitor voltage remains 4 V.
KCL gives downward capacitor current −2 A, so . The inductor has V, so its current slope is zero. The new slopes come from the new circuit.
- 5ChallengeApply continuity in a new case
A source-free parallel circuit starts with 3 V top-positive voltage, 1 A downward inductor current, 3 Ω and 0.5 F. What is the initial voltage slope?
---reveal---
The resistor draws 1 A downward. KCL requires capacitor current −2 A, so . The stored voltage is continuous, but the slope is set by the currents immediately after switching.
- 6TipKeep three circuit drawings
Use three drawings: the old DC state, the switching instant and the final DC state. At the instant, use the known capacitor voltage and inductor current. For settled DC, use an open capacitor and a shorted inductor.
- 7ExplanationBuild the series equation
Choose loop current into the capacitor’s positive terminal. KVL gives , while . Differentiate KVL and divide by inductance:
Comparing with the standard form identifies and . The two initial conditions retain the information removed by differentiation.
- 8ExplanationBuild the parallel equation
For a parallel circuit, direct all branch currents downward with top-positive voltage. KCL gives and the inductor law gives . Differentiate and divide by capacitance:
Thus . The resistor is across the shared voltage, so increasing its resistance reduces current loss and damping.
- 9ConnectionKeep the DC source in the driven equation
For a series voltage step, solve for capacitor voltage using . The right side becomes . For a parallel current step, solve for inductor current using , giving right side .
The left-side coefficients still determine the natural roots. The DC source determines the settled value: source voltage for the series capacitor, source current for the parallel inductor.
- 10ChallengeConnect the equation to the initial state
A 10 V step drives series 2 Ω, 1 H and 0.5 F from rest. Find the capacitor-voltage equation and its two initial conditions.
---reveal---
The starting capacitor voltage is zero by continuity. The starting current is also zero, so . The source does not create an instantaneous inductor-current jump.
- 11RecapCarry the state, then write the equation
Preserve capacitor voltage and inductor current at switching. Use the new KCL and KVL equations for their slopes, and use the final DC circuit where a settled value exists. Normalize the differential equation before reading its damping coefficient and natural frequency.
2Read roots and fit a response
13 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionPredict the shape before the constants
- 2ExplanationTurn derivatives into a quadratic
- 3ExampleClassify three parallel resistances
- 4ChallengeSelect a critical resistance
- 5ExplanationChoose two independent terms
- 6ExampleFit an underdamped displacement
- 7ChallengeFit a repeated-root response
- 8Key InsightMore damping can mean slower decay
- 9AnalogyFollow the energy between two stores
- 10ExampleChoose resistance for a target shape
- 11TipMeasure a full period and a true amplitude
- 12ChallengeRecover roots from a waveform
- 13RecapSeparate shape, scale and starting state
3Release stored energy in RLC circuits
12 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with energy already present
- 2ExplanationFind the parallel voltage slope
- 3ExampleFit the parallel voltage constants
- 4Key InsightOne reversal can happen without ringing
- 5ChallengeUse a signed initial inductor current
- 6ConnectionRecover every branch current
- 7ExampleSet a series discharge direction
- 8ExampleFit the current and capacitor voltage
- 9TipUse the correct repeated-root form
- 10ChallengeFit a new natural current
- 11ChallengeCompare series and parallel modes
- 12RecapLet the circuit set both starting conditions
4Build complete step responses
18 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionAdd a source without losing the initial state
- 2ExplanationUse the series capacitor final value
- 3ExampleFit the first constant
- 4ExampleFit the slope and recover the current
- 5Key InsightExplain the voltage above the supply
- 6ChallengeChange the initial capacitor charge
- 7ExplanationChoose inductor current in parallel
- 8ExampleFit a parallel current step
- 9ExampleDifferentiate to find the shared voltage
- 10ChallengeConvert a voltage-fed parallel pair
- 11ExampleDerive a mixed circuit equation
- 12ExampleFit the mixed response from rest
- 13ConnectionRecognize second order without an inductor
- 14ConnectionRecognize when there is no final value
- 15ExplanationBegin a second switching interval
- 16ChallengeCarry the state into a source-free loop
- 17ChallengeCombine the new circuit with shifted time
- 18RecapFit the response for each actual interval
5Check the answer and use the model
11 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionMake the algebra answer to the circuit
- 2ExampleCheck value, slope and final state
- 3TipCheck units before evaluating a time
- 4ChallengeFind a pulse peak from its derivative
- 5ConnectionCheck where the energy goes
- 6AnalogyMatch a circuit to mechanical motion
- 7ExampleEstimate the scale of an ignition pulse
- 8Key InsightSeparate a supply step from a load change
- 9ExampleTurn an overshoot limit into resistance
- 10ChallengeDesign and check the damping change
- 11RecapUse several independent checks
RLC Circuits practice questions
Set 1: RLC foundations in context10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Follow stored energy through a switch10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Combine roots and circuit laws10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Analyze switching and design choices10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 5: Solve new second-order scenarios10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
B
Branch current
C
Characteristic equation
Characteristic root
Charging current
Complete response
Continuity
Critical damping
Critical resistance
Current reference
Current step
D
Damped frequency
Damped period
Damping ratio
DC steady state
Discharge current
Dominant decay term
Duality
E
Energy balance
Envelope
Equilibrium offset
F
Final value
I
Ideal inverting integrator
Ignition pulse
Inductor-current slope
Initial slope
L
Loop current
M
Mass-spring-damper analogy
Mixed RLC circuit
N
Natural response
Neper frequency
Norton equivalent
O
Overdamping
Overshoot
Overshoot limit
P
Parallel RLC circuit
Passive sign convention
Peak amplitude
Peak time
R
RC ladder
Repeated root
Ringing
S
Saturation
Second-order circuit
Sequential switching
Series RLC circuit
Settling time
Shared voltage
Shifted time
Source term
Standard second-order form
Step response
T
Transient
Transient simulation
U
Undamped natural frequency
Underdamping
V
Voltage pulse
Z
Zero crossing
About this lesson
Make your own Study Materials
Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.