Resistive Circuits
BeginnerLesson 2 of 8 in Electric Circuits 1 Course
What you will learn
- Recognize series and parallel connections, replace them with one equivalent resistance, and reduce a series–parallel network step by step to find every current, voltage and power.
- Combine resistors in seriesIdentify resistors in series, add them to one equivalent resistance, and find the shared current, the voltage across each resistor and the power each one absorbs.
- Combine resistors in parallelIdentify resistors in parallel, combine them with reciprocals or conductances, and find the shared voltage, the branch currents and the power in each branch.
- Simplify a series–parallel network and find every currentReduce a resistor network to one equivalent resistance between two chosen terminals, then work back through the steps to find each branch current, each voltage and a power check.
- Combine resistors in series
- Use the voltage-divider and current-divider rules to find a voltage or current directly, design simple dividers, and account for loads, resistor tolerances and power ratings.
- Find voltages with the voltage-divider ruleDerive and apply the voltage-divider rule for two or more series resistors, and choose resistor values that give a required output voltage.
- Account for loading, tolerance and power in a dividerPredict how a connected load lowers a divider's output, find the worst-case output from resistor tolerances, and check each resistor's power.
- Split a current with the current-divider ruleDerive and apply the current-divider rule for two or more parallel branches, with resistances or with conductances.
- Use division to analyze a series–parallel circuitFind one voltage or current in a series–parallel circuit quickly by reducing only what is needed and then applying voltage and current division in turn.
- Find voltages with the voltage-divider rule
- Connect meters correctly, explain how ammeters and voltmeters are built from a basic meter movement, and estimate how much a real meter disturbs the circuit it measures.
- Connect ammeters, voltmeters and ohmmeters correctlyPlace each meter in the circuit the right way, interpret the sign of its reading, and avoid the connections that damage meters or give false readings.
- Build an ammeter or voltmeter from a d'Arsonval movementUse a moving-coil meter movement's full-scale ratings to design a shunt for an ammeter and a series multiplier for a voltmeter, and read the resulting scale.
- Estimate the loading error of a meterModel a real meter as a resistor, compute the reading it gives and the percent error, and decide whether a meter is good enough for a circuit.
- Connect ammeters, voltmeters and ohmmeters correctly
- Explain how a Wheatstone bridge finds an unknown resistance at balance and how an unbalanced bridge turns a small resistance change into a measurable voltage.
- Balance a Wheatstone bridge to find an unknown resistanceDerive the balance condition, use it to find an unknown resistor, and simplify a balanced bridge for other calculations.
- Read the output of an unbalanced bridgeCompute the output voltage of an unbalanced bridge from two voltage dividers and use it to sense a small change in a sensor's resistance.
- Balance a Wheatstone bridge to find an unknown resistance
- Recognize delta and wye connections, convert one into the other, and use the conversion to solve networks that series–parallel reduction cannot simplify.
- Recognize delta and wye connectionsIdentify three-terminal delta (pi) and wye (tee) connections in a network and explain what an equivalent three-terminal network preserves.
- Convert between delta and wyeApply the delta-to-wye and wye-to-delta formulas, including the balanced case, and check a conversion.
- Solve a bridge network with a delta–wye transformationTransform part of a bridge, reduce the result to one equivalent resistance, and work back to the current in every original resistor.
- Recognize delta and wye connections
Resistive Circuits study guide
1Combine resistors in series and parallel
Connections determine which quantities resistors share. A series path carries one current, while parallel branches share a voltage. You will use those facts to replace groups with equivalent resistances, then return to the original circuit to find its internal currents and voltages. Tracing nodes comes before arithmetic: a drawing can change shape without changing its connections. KCL, KVL, and power balance give useful checks on the result.
1.1 Combine resistors in series
Two resistors are in series when their shared node has no other connection. Charge has only one path through that junction, so KCL makes their currents equal. A bend in the wire changes nothing. A third branch at the junction changes the connection, even when the resistors still look end to end.
Replace the string
For a series string, KVL adds the resistor drops:
The equivalent resistance is therefore . An equivalent resistor draws the same current from the same terminal voltage as the original string. With positive resistances, the sum exceeds every individual resistance. Reordering the resistors leaves that sum and the shared current unchanged.
Find current, voltage, and power
Connect 100 Ω, 220 Ω, and 680 Ω in series across 12 V. First add the resistances:
Then apply Ohm's law to the entire string:
Use this same current in each original resistor. The drops, measured in the direction of current, are:
- 100 Ω: .
- 220 Ω: .
- 680 Ω: .
Their sum is 12 V. The largest resistance takes the largest drop because the current is the same in all three. If the reference voltage is marked opposite to the drop, its signed value is negative.
Power uses the same shared current:
The resistors absorb a total of 144 mW. The source delivers , so the power check agrees. A resistor does not use up current: it transfers electrical energy into heat while the steady current continues through the string.
Check the connection and the limits
Trace every point joined by ideal wire as one node. If a wire or another element leaves the junction between two resistors, do not assign them one shared current without checking the branch. For example, connecting a meter or load at the midpoint can stop the pair from being a simple series divider.
A zero-resistance wire in a series string adds zero to its equivalent resistance. An open circuit has a different effect: it breaks the only path, so the current becomes zero. Every finite resistor then has zero drop, and the source voltage appears across the gap. The absence of current does not mean that the voltage across the open gap is zero.
Key Takeaways
- Series elements share a current and have no branch at their joining node.
- Add series resistances; add their voltage drops to check KVL.
- With shared current, the larger resistance absorbs more power.
- An open series path has zero current; the gap can still have voltage.
1.2 Combine resistors in parallel
Resistors are in parallel when both ends connect to the same two nodes. They share the same voltage, even if the drawing places them far apart. Label the nodes at each end before deciding which resistors can be combined.
Add conductances
KCL adds the branch currents. For a common voltage ,
Comparing this with gives
Conductance is , measured in siemens (S). Thus parallel conductances add directly. After adding reciprocal resistances, invert the total to obtain resistance; the reciprocal sum itself has units of siemens.
For exactly two branches, the formula becomes
For example, 30 Ω in parallel with 60 Ω gives 20 Ω. For several equal resistors, : four 100 Ω branches give 25 Ω. Product over sum applies to two resistors at a time. For three branches, either use reciprocals or combine a pair and then combine its equivalent with the third.
Work through a parallel group
Place 6 Ω, 12 Ω, and 4 Ω across 12 V. Their conductances add to
Hence and the source current is 6 A. Each branch has the full 12 V:
The currents add to 6 A, as KCL requires. Use the shared voltage to find power:
Their sum is 72 W, equal to the source's delivered power. In parallel, the smallest resistance carries the most current and absorbs the most power. This follows from the common voltage; it is the reverse of the power ordering for resistors carrying a common series current.
Use size and limiting checks
A positive-resistance parallel equivalent must be smaller than the smallest branch resistance. Adding another finite positive branch lowers the equivalent. With the voltage held fixed, this raises the total current; it leaves each existing branch current unchanged.
A very large added branch changes the equivalent only slightly. A very small branch dominates it. An open branch carries no current and can be removed. A short across a resistor forces that resistor's voltage and current to zero. The parallel group's equivalent then becomes zero; connecting an ideal voltage source directly across an ideal short has no finite-current solution.
Key Takeaways
- Parallel resistors share both endpoint nodes and voltage.
- Add conductances, then invert to find resistance.
- Product over sum applies to two resistors at a time.
- The equivalent is smaller than the smallest positive branch.
- At fixed voltage, adding a branch increases total current.
- The smallest parallel resistance takes the most current and power.
1.3 Simplify a series–parallel network and find every current
An equivalent resistance belongs to a chosen pair of terminals. Start by marking those terminals and labeling the nodes. Then combine genuine series or parallel groups, redraw, and repeat. Keep a record of each replacement so you can later recover what happens inside it.
Reduce from the inside outward
A 40 V source feeds a 2 Ω resistor leading to node A. From A to the return node there are two branches: one is 12 Ω; the other is 6 Ω followed by an 8 Ω and 24 Ω parallel pair.
Begin with the deepest parallel pair:
That equivalent is in series with the branch's 6 Ω resistor, giving 12 Ω. Now the two branches are 12 Ω in parallel, giving 6 Ω. The source sees this in series with 2 Ω:
The original 6 Ω and 8 Ω resistors are not in series: the 24 Ω branch also joins their junction. Combining them first would erase a current split.
Reverse the replacements
The source current flows through the 2 Ω resistor, so its drop is 10 V. That leaves 30 V from A to return. Each 12 Ω branch therefore carries 2.5 A.
In the second branch, the original 6 Ω resistor drops . The other 15 V is across both members of the original parallel pair:
Their sum, 2.5 A, matches the current entering that branch. At A, the two branch currents add to the 5 A source current. Each recovered current belongs to the original resistor whose connection you have restored.
The resistor powers are 50 W in 2 Ω, 75 W in the separate 12 Ω branch, 37.5 W in 6 Ω, 28.125 W in 8 Ω, and 9.375 W in 24 Ω. They total 200 W, equal to W from the source.
Keep terminals and topology visible
The same network can have different equivalents at different terminal pairs. For a triangle with edges 10 Ω, 20 Ω, and 30 Ω, looking across the 10 Ω edge gives . Looking across the 30 Ω edge gives . The third terminal is open in each measurement.
A dangling resistor with one end unconnected carries no steady current. A resistor bypassed by an ideal wire has zero voltage. Remove those inactive parts before reduction, while keeping any terminals needed for the question.
If no genuine series or parallel pair remains, do not force a combination. A five-resistor bridge commonly reaches this point. A delta–wye transformation can change the internal connections and make reduction possible. An equivalent alone gives the behavior at its terminals; it does not list the original branch currents.
Record which quantity survives a replacement
Write the voltage across a replaced parallel group on its two outer nodes. When you restore its members, that voltage applies to every member. Write the current through a replaced series group on its path; when restored, each member carries that current. This record avoids confusing the 5 A source current, the 2.5 A branch current, and the smaller currents inside the parallel pair.
A KVL check through the second branch gives . Choose either the 8 Ω or 24 Ω path for the final drop; do not add their voltages together, because they describe alternative parallel routes.
Key Takeaways
- Mark the terminals and reduce genuine groups one replacement at a time.
- Reverse the replacements to recover original currents and voltages.
- Check junction currents, loop drops, and total power.
- A bridge may need a transformation before reduction can continue.
2Divide voltage and current
A resistor network can divide a source voltage or split an incoming current. The useful rule depends on the connection: voltage division follows a series path, and current division follows parallel branches. You will choose divider ratios, account for a connected load, and check tolerance and power. In larger networks, each divider acts on a whole equivalent group before you move inward to the resistor whose voltage or current you need.
2.1 Find voltages with the voltage-divider rule
A voltage divider uses a shared series current to split a source voltage. The output is the voltage across a selected resistor or group of consecutive resistors. Mark the output terminals first; they determine which resistance belongs in the numerator.
Derive the ratio
With two series resistors across a source,
Taking the output across the lower resistor gives
For a longer string, the drop across any one resistor is
Voltage divides in proportion to resistance. Across positive resistances, each drop lies between zero and the total applied voltage. A passive divider cannot produce a larger voltage than its source.
Read drops and tap voltages
For 24 V across 10 kΩ above 5 kΩ, the output across the 5 kΩ resistor is . The upper resistor drops 16 V. The 5 kΩ resistor goes in the numerator because it lies between the output terminals, not because it happens to be labeled second.
Now connect 1 kΩ, 2 kΩ, and 3 kΩ in that order from a 12 V positive terminal to return. The total is 6 kΩ, so the current is 2 mA. The individual drops are 2 V, 4 V, and 6 V. Measured from return, the lower junction is at 6 V and the upper junction at 10 V. A tap voltage includes all resistance between that tap and the reference node; it need not equal the drop across just one resistor.
Choose a divider
To obtain a chosen output across the lower resistor, rearrange the two-resistor rule:
For 12 V down to 5 V, choosing 10 kΩ for the lower resistor gives . The total current is 0.5 mA. Scaling both resistors down by ten, to 1.4 kΩ and 1 kΩ, keeps the same ratio and 5 V output but raises the current to 5 mA. The ratio sets the output; the scale sets current and power.
Check the midpoint and polarity
The simple rule requires the resistors to carry the same current. A load drawing current from their junction breaks that condition for the original pair. Replace the lower resistor and its load with their parallel equivalent before dividing.
With the source positive at the top, the junction is positive relative to return. Reversing the output reference polarity gives the negative of that voltage. This sign change describes the same physical circuit. A useful numerator check is that an output taken across the smaller resistor must be less than half the source voltage.
Key Takeaways
- Put the resistance across the output in the voltage-divider numerator.
- A tap voltage depends on its reference node.
- Scaling both resistances preserves the unloaded ratio but changes current.
- A simple divider needs equal current through its series resistors.
- Reverse the output reference polarity to reverse its sign.
2.2 Account for loading, tolerance and power in a divider
A divider's output depends on everything connected to its midpoint. A load across the lower resistor adds a parallel path, changes the branch resistance, and increases the current through the upper resistor. Real resistor tolerances and power limits also matter when you choose values.
Include the load before dividing
For a load across the lower resistor,
The upper resistor is in series with the whole lower parallel group. Because a finite positive load makes that group smaller than the original lower resistor, the output falls.
With 24 V and two 10 kΩ divider resistors, the unloaded output is 12 V. Add a 10 kΩ load: the lower equivalent becomes 5 kΩ, giving . The upper current is . It splits into 0.8 mA through each lower branch.
A 100 kΩ load instead gives about 11.43 V, 4.8% below the unloaded output. A 1 MΩ load gives about 11.94 V, 0.5% low. These percentages belong to this equal-resistor example. A load much larger than the lower divider resistor produces less sag.
Choose current and power deliberately
Reducing both divider resistances keeps their unloaded voltage ratio but makes the output less sensitive to a given load. The cost is more source current and more resistor heating. Larger resistors save power but allow greater output change under the same load. Dividers suit small-current reference, bias, sensor, and measurement inputs; a changing substantial load makes the output vary.
Calculate each resistor's power in the circuit actually connected. Use with that resistor's current, or with its voltage. The upper current is not generally the lower-resistor current once a load is present.
Find tolerance extremes
Tolerance gives the allowed deviation from a marked resistance. For the lowest output, take the upper resistance at its maximum and the lower at its minimum. Reverse those choices for the highest output. Equal percentage changes in both resistors leave the ratio unchanged.
For 20 V across 15 kΩ above 5 kΩ, each with ±5% tolerance, the nominal output is 5 V. The extremes are
The nominal current is 1 mA, giving 15 mW and 5 mW in the two resistors. Both are below a 0.25 W rating. Common small-resistor ratings include 0.125 W, 0.25 W, and 0.5 W. Check the relevant worst operating case as well as the nominal case before selecting a rating.
Track power after the load is attached
In the 24 V, equal-10 kΩ example with a 10 kΩ load, the upper resistor has 16 V across it and absorbs . The lower resistor and load each have 8 V and absorb 6.4 mW. Together they absorb 38.4 mW, matching the source's .
The unchanged marked resistances do not imply unchanged heating. Connecting the load increases upper-resistor power while decreasing the original lower-resistor power. Evaluate ratings component by component instead of dividing total power equally.
Key Takeaways
- Combine a load in parallel with the lower resistor before dividing.
- Smaller divider resistors reduce sag at the cost of current and power.
- Opposite tolerance extremes produce the extreme divider outputs.
- Calculate each resistor’s power using its own loaded voltage or current.
- A divider output changes with its load.
2.3 Split a current with the current-divider rule
A current divider splits an incoming current among parallel branches. The branch voltages agree, while their currents depend on their resistances. Start with the total current entering the parallel group, which may be only part of the current from a larger circuit.
Use the common voltage
If the parallel equivalent is known, its voltage is . Ohm's law then gives any branch current:
This works for two, three, or more parallel branches. In conductance form,
A larger conductance takes a larger share. Equivalently, a smaller resistance takes more current. This inverse relationship is a useful check before calculating.
Apply the two-branch shortcut
For two resistors, substitute their product-over-sum equivalent into the general rule:
The other branch's resistance appears in the numerator. This is different from voltage division, where the numerator is the resistance across which the voltage is required.
Suppose 6 mA enters 2 kΩ in parallel with 4 kΩ. The 2 kΩ branch receives , and the 4 kΩ branch receives 2 mA. Their currents sum to 6 mA. Both give the same branch voltage: .
Using the branch's own resistance in the numerator would swap these currents. It would also predict more current in the higher resistance despite an equal voltage, which conflicts with Ohm's law.
Extend to more branches
Let 12 A enter 6 Ω, 12 Ω, and 4 Ω in parallel. Their equivalent is 2 Ω, so the group voltage is 24 V. The general rule gives
KCL checks the total: 4 A plus 2 A plus 6 A equals 12 A. Do not put three resistances into the two-branch shortcut. You can instead combine the branches other than the target into one equivalent and use that as the other branch.
Reference arrows still control signs. If a requested arrow points against the actual current, report a negative value. The physical split is unchanged. The voltage-divider and current-divider rules both come from Ohm's law and a shared quantity: common current in series, common voltage in parallel.
Combine the other branches when useful
In the three-branch example, suppose only the 4 Ω current is wanted. The other two resistors combine to . The target 4 Ω branch and this 4 Ω equivalent then split the 12 A equally, giving 6 A to the target. The current in the other equivalent is a total that will split again if its internal currents are needed.
This approach explains what the two-branch formula is dividing. Its numerator can represent several original resistors, provided they have been correctly combined into the single opposing branch between the same two nodes.
Key Takeaways
- Current splits in proportion to conductance.
- The two-branch numerator is the other branch’s resistance.
- For any number of branches, multiply total group current by equivalent resistance over target resistance.
- Branch currents must sum to the incoming group current.
2.4 Use division to analyze a series–parallel circuit
A target resistor in a larger network may not belong to a simple divider until you replace surrounding groups. Reduce enough of the circuit to expose a valid division step. Then move back toward the target, using the voltage or current of the group that contains it.
Divide between whole groups
A 36 V source feeds an 8 Ω resistor. After it, the circuit splits into a 24 Ω branch and a branch containing 4 Ω followed by 8 Ω. Find the voltage across the 8 Ω resistor inside that second branch.
The second branch is 12 Ω. Combining the two branches gives
The source now sees two equal series groups: the original 8 Ω resistor and the 8 Ω parallel equivalent. Their shared voltage division gives
Restore the second branch. Its 4 Ω and 8 Ω resistors share 18 V, so the target voltage is
The first numerator represents the whole parallel group; the second represents one original resistor within a branch. Each denominator is the total series resistance at that particular stage.
Check through current division
The source sees 16 Ω and supplies . That current enters the 24 Ω and 12 Ω parallel branches. The 12 Ω branch receives
The original 8 Ω target therefore drops , agreeing with the voltage route. The 24 Ω branch carries 0.75 A; the sum is 2.25 A. The voltage route can be shorter when only one output voltage is wanted, while the current route gives useful branch currents along the way.
Preserve downstream loading
A tempting incorrect first step is to divide 36 V between the original 8 Ω and the 24 Ω branch alone. That gives 27 V across the branch but ignores the other current path. The original 8 Ω carries the sum of both branch currents, so it is not in series with either branch separately.
Several divider ratios can be multiplied:
The earlier ratio must include the equivalent resistance of everything connected downstream. Two divider stages joined at a midpoint generally load each other. Do not multiply their separate unloaded ratios unless the connections really preserve those ratios. On the redrawn circuit, check series current equality or shared parallel nodes before each division.
Use the chosen route to check signs and bounds
In the worked network, the 4 Ω resistor drops . The two drops inside that branch are therefore 6 V and 12 V, adding to its 18 V. The source-side 8 Ω drops the other 18 V. A loop through the target branch checks as .
The target's 12 V must be less than its branch's 18 V, which must be less than the positive source's 36 V. These bounds follow from the positive resistor values and the chosen drop directions. They can expose an incorrect ratio without calculating every other current.
Key Takeaways
- Divide between whole equivalent groups before working inward.
- Every chained ratio must include the load of everything downstream.
- Current division and voltage division can provide independent routes to a target.
3Measure voltage, current and resistance
A meter becomes part of the circuit it measures. Its connection determines whether it samples a voltage, carries a current, or tests a resistance. Ideal meters make the basic method clear; real meter resistances explain why a reading can change when the meter is connected. You will also build current and voltage ranges around a moving-coil movement, then calculate whether the resulting loading error is acceptable for a measurement.
3.1 Connect ammeters, voltmeters and ohmmeters correctly
An ammeter measures current through a path; a voltmeter measures the potential difference between two nodes. Their names tell you the quantity, but their internal resistance explains how to connect them and how they affect the circuit.
Put each meter in the right place
| Meter | Connection | Ideal resistance | Ideal effect |
|---|---|---|---|
| Ammeter | In series with the measured path | Zero | No added voltage drop |
| Voltmeter | Across the measured nodes | Infinite | No current drawn |
For current, open the path and insert the ammeter so the branch current passes through it. For voltage, leave the circuit path intact and attach the voltmeter across the two nodes. A real current meter adds a small series resistance. Its resulting drop is called the burden voltage. A real voltage meter adds a large but finite parallel resistance; a common digital DC-voltage input is about 10 MΩ.
Never connect an ammeter directly across a source: its low resistance can produce a damaging current. For resistance measurements, switch off circuit power and disconnect at least one end of the resistor before connecting the ohmmeter.
Read the sign
A digital voltmeter reads positive when its red voltage lead is at a higher potential than COM. A current reading is positive when current enters the red current lead. Swapping the leads reverses the reading's sign. For example, a reading of −3 V means the red lead is 3 V below COM; the magnitude of the potential difference is still 3 V.
This is the same reference-direction idea used in a calculation. A negative current tells you that actual current flows opposite to the marked reference arrow. It does not mean that the meter has found a negative resistance.
Diagnose a wrong connection
A voltmeter inserted in series adds its large resistance to the current path. With a 9 V source, a 1 kΩ resistor, and a 10 MΩ voltmeter all in series,
The voltmeter then reads about 8.999 V. Almost the full source voltage appears across the meter, while the resistor receives only about 0.0009 V. A plausible-looking meter reading can therefore belong to a circuit that the connection has greatly changed.
Measure a resistor separately
An ohmmeter supplies a small test current or voltage and infers resistance from the response. If a resistor remains connected to other paths, the reading is their combined resistance. A 10 kΩ resistor with a second 10 kΩ path across it reads 5 kΩ, even if the first resistor is correct. Isolating one end removes that alternate path. The resistance reading then belongs to the component whose value you intend to check.
Distinguish a lead reversal from a topology change
Reversing voltage leads on the same pair of nodes changes only the reference polarity. Moving a lead to another node changes the physical voltage being measured. Likewise, reversing the reference arrow for an already known branch current changes its signed description, while inserting a meter into a different branch measures a different current.
The ideal models clarify the connection test: a zero-resistance ammeter can replace a small piece of wire in the intended path, while an infinite-resistance voltmeter adds no conducting path across its measured nodes.
Key Takeaways
- Insert an ammeter in series; connect a voltmeter across two nodes.
- An ideal ammeter has zero resistance; an ideal voltmeter draws no current.
- A negative reading reverses the connected reference direction.
- An ohmmeter tests resistance with its own excitation.
- Other connected paths can lower a resistance reading.
3.2 Build an ammeter or voltmeter from a d'Arsonval movement
A d'Arsonval movement, also called a moving-coil movement, deflects a pointer in proportion to coil current. Its full-scale current and voltage describe the largest normal scale reading. External resistors turn that sensitive movement into meters with useful ranges.
Start with the movement
A movement rated at 1 mA and 50 mV has coil resistance
Both ratings describe the same full-scale operating point. At half that current, the pointer is halfway along a linear scale.
Extend the current range
An ammeter uses a shunt in parallel with the coil. The shunt carries the part of the measured current that the coil cannot carry. At full scale, both paths have the movement's full-scale voltage:
For a 1 A range, the shunt current is 0.999 A and
The complete meter's resistance is , also obtained from 50 mV divided by 1 A. The shunt resistance and whole-meter resistance are close here, but they are different quantities.
For a 10 mA range with this same movement, the shunt carries 9 mA. It needs . Dividing by the entire 10 mA would give 5 Ω and divert too much current from the coil. Subtracting the movement current matters most when the selected range is close to the movement's own range.
Extend the voltage range
A voltmeter uses a multiplier resistor in series with the coil. The desired range voltage must drive exactly the full-scale coil current:
On a 150 V range, the total resistance must be 150 kΩ. Subtract the 50 Ω coil to obtain a multiplier of 149 950 Ω. Using 150 kΩ as the multiplier would count the coil resistance twice in the total.
Relate range, sensitivity, and reading
Voltmeter sensitivity is in ohms per volt. The 1 mA movement has 1000 Ω/V sensitivity. A 50 µA movement has 20 kΩ/V sensitivity. Multiply sensitivity by the selected full-scale voltage to obtain total input resistance.
A pointer at 40% of the 150 V scale reads 60 V and carries 0.4 mA in the coil. A multirange analog meter selects different shunts or multipliers. Digital meters use the same resistor ideas, with an analog-to-digital converter replacing the pointer movement.
Check the full-scale paths
For the 1 A ammeter, the shunt and coil currents must add to exactly 1 A. Their voltage drops must also agree: and . These are KCL and the parallel-voltage condition applied to the meter itself.
For the 150 V voltmeter, the 1 mA current gives 149.95 V across the multiplier and 0.05 V across the coil. The drops total 150 V. This check distinguishes the added resistor from the complete instrument and catches a multiplier that forgot to subtract the coil resistance.
Check the added resistors' power
At the 1 A ammeter limit, the shunt absorbs . The coil absorbs another 0.05 mW. Their total, 50 mW, matches the complete meter's terminal power of 50 mV times 1 A.
In the 150 V voltmeter, the multiplier absorbs while the coil still absorbs 0.05 mW. Choosing a resistance value establishes a range, but the added resistor must also have a suitable power rating. Use the current and voltage of the added resistor itself, not the entire range current through a shunt or the entire range voltage across a multiplier.
Key Takeaways
- Movement resistance is full-scale voltage divided by full-scale current.
- A shunt carries the range current minus the coil current.
- A multiplier adds enough series resistance for the chosen voltage range.
- Sensitivity is the reciprocal of full-scale current.
- Total voltmeter resistance equals sensitivity times range.
- A linear-scale reading equals range times deflection fraction.
3.3 Estimate the loading error of a meter
A real meter measures the circuit with that meter connected. Its resistance changes the circuit, so the reading can differ from the true value, meaning the value before connection. This difference is loading error, even when the meter itself is accurately calibrated.
Model a voltmeter as a parallel resistor
A 50 V source feeds two 100 kΩ series resistors. Before measurement, the lower resistor has 25 V across it. Connect a 150 kΩ voltmeter across it:
The upper resistance stays 100 kΩ, giving
The meter reads the loaded output, not the original 25 V. Define signed percentage error as
Here the error is . The negative sign identifies a low reading; the error magnitude is 25%.
A 10 MΩ digital meter in the same circuit gives . The reading is about 24.88 V, or 0.5% low. Its larger input resistance draws much less current from the midpoint.
Model an ammeter as a series resistor
A 10 V source across 100 Ω produces 100 mA without a meter. Inserting a 5 Ω ammeter raises the total to 105 Ω:
The error is about −4.76%. For this circuit, a smaller ammeter resistance would disturb the current less. Its burden voltage is the measured current times its resistance, about 0.476 V here.
Judge the resistance ratio
In passive resistor circuits supplied by independent ideal sources, a voltmeter resistance at least 100 times the resistor being measured gives less than about 1% loading error. The surrounding passive resistance can further reduce the resistance seen at the measurement terminals. For an exact error, use the whole circuit and recompute the loaded value.
For an ammeter, compare its resistance with the full path resistance that its insertion increases. Voltage loading is especially noticeable in high-resistance networks; current loading is especially noticeable in low-resistance paths.
For an analog voltmeter, input resistance equals sensitivity times range voltage. Selecting a higher voltage range increases its input resistance and reduces loading. The pointer then occupies a smaller fraction of the scale, making its position harder to read precisely. Choosing a range therefore involves both circuit disturbance and scale resolution.
Separate circuit error from scale error
Loading calculations predict a changed physical value. Better scale resolution alone cannot restore the voltage or current that existed before connection. A meter of the same resistance with finer display digits still imposes the same load.
For the analog example, the meter draws . The original lower resistor draws 0.1875 mA, while the upper resistor carries their 0.3125 mA sum. This extra current through the upper resistor produces its larger drop. Tracing that split explains the low reading without treating the meter as faulty.
Key Takeaways
- Model a voltmeter in parallel and an ammeter in series.
- Loading error compares the connected reading with the value before connection.
- A higher voltmeter resistance and a lower ammeter resistance reduce disturbance.
- An analog voltage range changes both input resistance and scale use.
4Measure resistance with a Wheatstone bridge
A Wheatstone bridge compares two voltage-divider outputs. At balance the midpoint voltages agree, so a zero detector reading lets you determine an unknown resistance from a ratio. Away from balance, the difference between those voltages can reveal a small sensor resistance change. You will keep the resistor labels and output polarity explicit, because reversing either changes the equation or the sign of the answer.
4.1 Balance a Wheatstone bridge to find an unknown resistance
A Wheatstone bridge compares two resistor ratios by detecting a zero current between their midpoints. Keep one labeling scheme throughout: source positive at a, return at b, left midpoint c, and right midpoint d. The arms are R₁ from a to c, R₃ from c to b, R₂ from a to d, and Rₓ from d to b.
Find the balance condition
A sensitive galvanometer connects c to d. At balance it carries zero current because the midpoints have equal potentials. Each side then acts as an unloaded voltage divider:
Set these equal, cancel the nonzero source voltage, and cross-multiply:
The common product cancels, leaving
The products of opposite arms agree. Equivalently, the upper-to-lower resistance ratio is the same on both sides. Balance does not require all four resistors to be equal.
Measure the unknown
Take 100 Ω for R₁ and 1000 Ω for R₂. Adjust R₃ until the detector reads zero; suppose balance occurs at 472 Ω. Then
The ratio of the two top arms multiplies the adjustable resistance by ten. Detector deflection on either side of zero tells you which way the midpoint difference points; adjustment brings that difference to zero.
Neither the source voltage nor detector resistance appears in the ideal balance equation. Source magnitude affects detector response away from balance, but it does not change the resistance ratio at the null. Measurement accuracy still depends on the known resistor values and how well the detector resolves a small departure from zero.
Simplify a balanced bridge
At balance, the detector branch has zero voltage and current. Removing it leaves the rest unchanged. The resistance between a and b in the example is
Joining c and d with an ideal wire also leaves the other currents unchanged at this balance point. The equivalent can then be found as
An unbalanced bridge does not permit either replacement without changing its behavior. Check the ratio before removing the cross branch.
Ordinary balanced bridges are typically useful from about 1 Ω to 1 MΩ. Below about 1 Ω, lead and contact resistance can become a substantial part of the reading. Kelvin double bridges separate those effects in low-resistance measurement.
Check the measured ratio directly
In the balanced example, and are equal. Each midpoint is therefore the same fraction of the source voltage above b. The two side currents need not be equal: the right side has ten times the total resistance and one tenth of the left-side current.
Zero detector current is a comparison between midpoint potentials. It does not say that the bridge draws no source current. Each complete side still forms a conducting path from a to b, which is why the input equivalent remains finite.
Key Takeaways
- Balance means equal midpoint potentials and zero detector current.
- With the defined labels, opposite-arm products agree at balance.
- At balance, source voltage and detector resistance drop out of the resistance ratio.
- Only a balanced cross branch can be removed without changing the other currents.
- Known resistor accuracy and detector resolution affect the measurement.
4.2 Read the output of an unbalanced bridge
A sensor bridge turns a resistance change into a difference between midpoint voltages. Use the same arms as the balanced bridge: R₁ above R₃ on the left, R₂ above Rₓ on the right, and source voltage from a to b. Define the output from c to d, so .
Subtract the two divider outputs
With an output instrument that draws negligible current, the two sides remain unloaded dividers:
A strain gauge, thermistor, resistance temperature detector, or photoresistor can occupy the sensor arm. Set the bridge to balance at a reference condition. A change in the sensor resistance then moves its midpoint away from the other midpoint.
For 5 V excitation and three fixed arms of 1 kΩ, let the lower-right sensor rise to 1010 Ω. The left midpoint remains at 2.5 V. The right midpoint becomes
Subtracting in the defined order gives . The negative sign means d is above c. With positive excitation in this arrangement, increasing the lower-right sensor raises the right midpoint and makes this output negative.
Estimate a small change
For equal nominal arms of resistance and sensor resistance , the exact expression simplifies to
When , its magnitude is approximately
The example gives a 12.5 mV approximation, close to 12.44 mV. For a large change, retain the exact denominator. If the sensor doubles to 2 kΩ, the exact magnitude is about 0.833 V; the small-change expression would give 1.25 V and substantially overestimate it.
Interpret what the bridge removes
The sensor-side divider alone has a midpoint near 2.5 V, with a small useful change on top. Subtracting the fixed-side midpoint removes that reference offset, so the bridge output begins at zero and can be amplified to show a small change.
In unbalanced operation, the output is proportional to excitation voltage. A stable excitation helps keep a sensor reading stable. This differs from a balanced resistance measurement, where the source voltage cancels from the null condition.
A finite-resistance detector draws current between the midpoints and loads both dividers. The separate divider equations then no longer describe their voltages. Treat the detector as a fifth resistor and solve the resulting network, for example by delta–wye conversion.
Separate a resistance change from its cause
The bridge equation converts the sensor resistance into a voltage; it does not by itself convert voltage into temperature, strain, or light level. That next conversion needs the sensor's resistance relationship to the measured quantity. A positive or negative output can identify the direction of resistance change once the arm position and polarity are fixed.
The left and right midpoint voltages remain much larger than their difference in the small-change example. Subtracting those potentials is therefore a different measurement from reading either midpoint against the return node.
Key Takeaways
- A negligible-current output reads the difference of two divider voltages.
- Output sign depends on the sensor position and reference polarity.
- The linear small-change estimate requires a change much smaller than the nominal resistance.
- Unbalanced output scales with excitation voltage.
- A finite detector resistance loads the bridge.
5Transform delta and wye networks
Some resistor networks have no series or parallel pair to combine. Delta–wye transformations replace a three-terminal group with a different internal connection that behaves the same at those terminals. You will identify valid groups, convert their resistances, and reduce the new circuit. The final step returns to the original network: terminal voltages transfer across the replacement, but currents inside the replacement need not match original branch currents.
5.1 Recognize delta and wye connections
A delta connects three resistors in a closed triangle between three terminals. A wye connects each of three terminals to a shared center through one resistor. Their shapes can be redrawn; the connections, not the outline on the page, identify the network.
Recognize the same connections in new shapes
A delta is also called a triangle or mesh. A pi network is the same delta topology drawn with an upper crosspiece and two side arms. A wye is also called a star, and a tee network is the same wye topology drawn as a T.
Label the outer terminals 1, 2, and 3. In a delta, each resistor has a terminal pair as its endpoints. In a wye, each resistor has one outer terminal and the shared center as its endpoints. A valid wye center joins exactly those three resistors and no external branch. An extra connection at the center would create a fourth accessible terminal and prevent the three-terminal replacement.
Understand equivalence
Equivalent delta and wye networks have the same resistance between every pair of terminals when the third terminal is left open. For terminals 1 and 2, the wye path contains its first two arms in series. Its third arm is dangling and carries no current. In the delta, the direct 1–2 edge is in parallel with the two-edge path through terminal 3.
Matching all three terminal-pair resistances makes the networks behave identically for any external circuit connected to those terminals. External terminal voltages and currents agree. The wye center, however, is an internal node with no counterpart in the delta, and individual resistor currents need not agree between the two forms.
Find a transformable group in a bridge
In a five-resistor bridge, let a be the top node, b the bottom node, and c and d the midpoints. The cross resistor runs from c to d. The upper three resistors form the delta a–c–d; the lower three form the delta c–d–b. There is also a wye centered at c and another centered at d.
Transforming one of these groups can create a new series or parallel pair. A delta-to-wye conversion adds an internal center node. A wye-to-delta conversion removes its internal center node. Preserve each of the three outer terminal labels while redrawing, so every external branch stays connected to the same terminal.
The replacement helps solve the external network, but it does not assign original internal currents. After calculating terminal voltages, restore the original delta or wye and use those endpoint voltages with Ohm's law. A current in a newly created arm is a current in the replacement network only.
Key Takeaways
- Delta and wye are three-terminal topologies, regardless of drawing shape.
- A wye center must have no external connection.
- Equivalence preserves all terminal voltages and currents.
- Internal branch currents need to be recovered in the original network.
5.2 Convert between delta and wye
Delta–wye formulas depend on terminal labels. Let the delta edges be R₁₂, R₂₃, and R₃₁. Let each wye arm R₁, R₂, or R₃ run from its numbered terminal to the center. Write those labels on the drawing before substituting values.
Convert delta to wye
Let the sum of all delta resistances be . Each wye arm uses the two delta edges touching its outer terminal:
For delta edges 20 Ω, 30 Ω, and 50 Ω in that order, the sum is 100 Ω. The wye arms are
Notice that the arm at terminal 1 uses edges 1–2 and 3–1. The edge 2–3 is opposite that terminal and appears only in the denominator sum.
Convert wye to delta
Form the sum of pairwise products:
Then divide by the arm at the terminal opposite the desired delta edge:
For arms 10 Ω, 6 Ω, and 15 Ω, the product sum is . The delta edges become 20 Ω, 30 Ω, and 50 Ω, recovering the original values. An equivalent expression for the first edge is .
Check what the terminals see
With terminal 3 open, the wye gives between terminals 1 and 2. The delta gives . The other two terminal pairs give the same agreement. This terminal-pair comparison is also the basis of the conversion formulas: equate the resistances for all three pairs and solve the resulting relationships.
For a balanced network with three equal delta edges, each wye arm is one third of a delta edge. Conversely, each balanced delta edge is three times a wye arm. Three 30 Ω delta edges therefore become three 10 Ω wye arms; their pair resistance is 20 Ω in either form.
For positive resistances, each converted wye arm is smaller than either adjacent delta edge. Each converted delta edge is larger than the sum of the two wye arms at its ends. These checks can catch a wrong product or opposite-arm denominator before the converted circuit is reduced.
Keep the opposite-arm label explicit
For a wye-to-delta edge between terminals 1 and 2, terminal 3 is the opposite terminal, so its arm divides the product sum. A direct size check follows from : the extra term is positive, so the delta edge exceeds the endpoint-arm sum.
For delta to wye, the denominator sum exceeds either adjacent delta edge. The product divided by that sum is therefore smaller than each edge in the numerator. These checks test the label assignment as well as the numerical scale.
Derive one arm from the three pair measurements
Write the open-third-terminal pair resistances as , , and . In the wye they are , , and . Adding the first and third and subtracting the second isolates the first arm:
For the delta, . Substitute the corresponding expressions for all three pairs into the isolated-arm equation. The mixed products involving the opposite edge cancel, leaving . This explains why the numerator uses the edges touching terminal 1: that arm appears in the two pair paths that include terminal 1, but not in the remaining pair path.
Key Takeaways
- A wye arm is the adjacent delta-edge product divided by the delta sum.
- A delta edge is the pairwise wye-product sum divided by the opposite arm.
- Check terminal-pair resistance with the third terminal open.
- Balanced delta edges are three times balanced wye arms.
- Use size bounds to catch label or arithmetic errors.
5.3 Solve a bridge network with a delta–wye transformation
A bridge with a finite cross resistor generally has no series or parallel pair. Convert a valid three-terminal group, reduce the replacement, and then recover original currents from the unchanged terminal voltages. Keep the original drawing beside the transformed one.
Transform the upper triangle
A 40 V source connects a to return b. The original edges are 20 Ω from a to c, 50 Ω from a to d, 30 Ω from c to d, 14 Ω from c to b, and 5 Ω from d to b.
The upper delta a–c–d has a 100 Ω sum. Convert it to arms from a, c, and d to a new center o:
The external 14 Ω and 5 Ω resistors remain connected to c and d.
Reduce and find terminal voltages
From o to b, one branch is and the other is . They are in parallel and give 10 Ω. Adding the arm from a gives
The source current is 2 A. The equal lower branches each carry 1 A. Measured from b, the unchanged lower resistors give
These are terminal voltages of the converted group, so they also hold in the original circuit.
Restore the original resistors
Use the actual endpoint difference for each original edge:
The cross current flows from c to d. The unchanged lower currents remain 1 A each. At c, the incoming 1.3 A equals the outgoing 1 A plus 0.3 A. At d, 0.7 A plus 0.3 A supplies the 1 A lower branch.
The resistor powers are 33.8 W, 24.5 W, 2.7 W, 14 W, and 5 W. They total 80 W, matching W delivered by the source.
Distinguish original and replacement currents
The 2 A in the wye arm from a is the total terminal current. In the original delta it splits into 1.3 A and 0.7 A; neither original upper resistor carries 2 A. Equivalence preserves terminal behavior, not a one-to-one match between internal branches.
Other valid conversions also work, including the wye centered at c. Choose a group that creates useful combinations after redrawing. The original 30 Ω cross resistor can represent a finite-resistance bridge detector. Its 0.3 A current shows why the unloaded-divider bridge formula cannot be used for this loaded circuit.
Keep the original and transformed node lists separate
The transformed center o is 20 V above b in the example, because the 2 A source current drops 20 V across the new 10 Ω arm. This helps check the replacement paths: the arm toward c drops 6 V and the arm toward d drops 15 V, giving c = 14 V and d = 5 V.
Only a, c, and d were outer terminals of the replaced group. Their potentials transfer to the original triangle; the 20 V center potential does not name a point in that triangle. Using it as an original endpoint would invent a node and give incorrect original currents.
Check with a different conversion
The original wye centered at c has arms of 20 Ω to a, 30 Ω to d, and 14 Ω to b. Its pairwise-product sum is . Converting it gives delta edges a–d of Ω, d–b of 65 Ω, and a–b of Ω.
The new a–d edge is parallel with the original 50 Ω, giving 32.5 Ω. The new d–b edge is parallel with the original 5 Ω, giving Ω. Those two equivalents are now in series; their sum is Ω. It lies in parallel with the new a–b edge of Ω, giving 20 Ω overall. The same input equivalent follows from either conversion, despite different internal replacement paths.
Key Takeaways
- Preserve the three outer terminal labels during a conversion.
- Reduce the transformed circuit to find its terminal voltages.
- Use original endpoint voltages and resistances for original currents.
- Check recovered currents with KCL and total power.
Resistive Circuits examples
1Reduce a network and restore its branch values
14 steps
- 1IntroductionStart with the connections
A resistor’s position on the page does not determine its connection. Series elements share an unbranched path; parallel elements share two endpoint nodes.
Reduction replaces a group with one resistor that behaves the same at its terminals. We will first make those replacements, then reverse them to find the currents hidden inside the equivalent.
- 2ExplanationFind an unbranched junction
Trace all points joined by ideal wire as one node. Two resistors are in series only when their shared node has no third connection, so they carry one current.
Their drops add by KVL: . Factoring out the current gives . A third branch at their junction would let current split and remove that simple series relationship.
- 3ExampleUse the shared series current
Connect 100 Ω, 220 Ω, and 680 Ω across 12 V. Their total is 1000 Ω, giving .
Multiply that same current by each original resistance: the drops are 1.2 V, 2.64 V, and 8.16 V. They add to 12 V. The increasing drops do not mean current is being used up; each resistor carries 12 mA and absorbs energy at its own rate.
Use the 680 Ω drop to check its power: . The voltage in this power calculation belongs to that resistor, while the current belongs to the shared series path.
- 4ChallengeCheck the biggest series drop
A 16 V source drives 200 Ω and 600 Ω in series. What voltage is across the 600 Ω resistor?
---reveal---
The total is 800 Ω and the shared current is 20 mA. The requested drop is . The other resistor drops 4 V, so the two drops add to 16 V.
- 5ExplanationTrace both parallel endpoints
Parallel resistors connect to the same two nodes and share voltage. Their currents add, which gives .
The reciprocal sum is conductance in siemens. Invert it to report resistance. For two branches only, product over sum is a shortcut: . The result must be smaller than either positive branch resistance.
- 6ExampleFind currents from common voltage
Put 6 Ω, 12 Ω, and 4 Ω in parallel across 12 V. Their conductances sum to 0.5 S, so the equivalent is 2 Ω.
Each branch sees 12 V, giving currents of 2 A, 1 A, and 3 A. Their sum is 6 A, matching . The smallest resistance takes the largest current because all three have the same applied voltage.
The branch powers are 24 W, 12 W, and 36 W. They total 72 W, equal to the source’s 12 V times 6 A. Common voltage makes lower resistance mean both greater current and greater heating.
- 7ChallengeRecognize an equal parallel group
Five identical 150 Ω resistors are connected between the same two nodes. What is their equivalent, and what happens if one branch opens?
---reveal---
Initially the equivalent is . After one opens, four branches remain, giving . Removing a conducting path raises the equivalent; the open branch carries no current.
- 8ExampleSet up the nested network
A 40 V source feeds 2 Ω and then node A. From A to return, one branch is 12 Ω. The other is 6 Ω followed by an 8 Ω–24 Ω parallel pair.
Start with the inner pair: . That equivalent is in series with the original 6 Ω, making the entire second branch 12 Ω. The original 6 Ω and 8 Ω were not series elements because 24 Ω also joined their junction.
- 9ExampleFinish the reduction
The two paths from A to return are now 12 Ω each, so their equivalent is 6 Ω. Add the source-side 2 Ω to obtain .
The source supplies . Keep the intermediate drawings: the single 8 Ω equivalent gives the source current, but it cannot by itself tell you the current in the original 24 Ω resistor.
The series 2 Ω carries this entire source current. At A, that current will split between the two restored branches; it cannot be assigned unchanged to every original resistor.
- 10ExampleWork back to node A
The original 2 Ω resistor carries 5 A and drops 10 V. Therefore node A is 30 V above return.
Both 12 Ω branches receive those 30 V, so each carries 2.5 A. In the second branch, the original 6 Ω resistor drops . The remaining 15 V must lie across the inner parallel pair.
The inner pair is not across the full 30 V from A. Its feeding 6 Ω drops half of that branch voltage, leaving the 15 V used to restore the pair.
- 11ExampleRestore the inner branch currents
Restore 8 Ω and 24 Ω across the known 15 V. Their currents are and .
They add to 2.5 A, matching the current entering that pair. At node A, the two outer currents add to 5 A. These local KCL checks identify the stage of the calculation where a missing split would show up.
You can also check the shared voltage by multiplying each recovered current by its resistance: V and V. A split that failed this test would not represent parallel branches.
- 12Key InsightCheck the energy rate
The source delivers . In the original resistors, the powers are 50 W, 75 W, 37.5 W, 28.125 W, and 9.375 W.
Their sum is also 200 W. Use original branch currents or voltages for this check. Assigning the source current to an internal parallel resistor would overstate its power and violate the junction-current check.
- 13ChallengeReduce and restore a new target
A 24 V source feeds 2 Ω, then 12 Ω in parallel with a series pair of 3 Ω and 9 Ω. What current flows through 9 Ω?
---reveal---
The series branch is 12 Ω, so the parallel group is 6 Ω and total resistance is 8 Ω. Source current is 3 A; it splits equally into the two 12 Ω branches. The 9 Ω resistor carries 1.5 A, the current of its whole series branch.
- 14RecapUse the shared quantity at each step
For a series group, retain its common current when restoring the resistors. For a parallel group, retain its common voltage.
Keep terminal labels and the reduction sequence, then check the original circuit with current sums, voltage sums, and total power. If no series or parallel pair exists, a topology-changing equivalent may be needed before reduction can continue.
2Use divider rules without losing the load
16 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionChoose the ratio from the connection
- 2ExplanationDerive the voltage ratio
- 3ExampleDesign a ratio and choose its scale
- 4ChallengeFind a tap from the return node
- 5ExplanationInclude the parallel load
- 6Key InsightChoose resistance with loading in mind
- 7ExampleFind the output limits
- 8ChallengeCheck loaded power
- 9ExplanationDerive current division
- 10ExampleCheck the split by common voltage
- 11ChallengeSplit among three branches
- 12ExampleExpose the first divider
- 13ExampleMove inward to the target
- 14TipKeep downstream resistance in the ratio
- 15ChallengeCombine loading and internal division
- 16RecapMatch every ratio to its group
3Predict what a meter will read
14 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionThe meter joins the circuit
- 2ExplanationConnect by the measured quantity
- 3ExampleInterpret sign and resistance readings
- 4ChallengeDiagnose a series voltmeter
- 5ExplanationRead the movement’s ratings
- 6ExampleDesign the ammeter shunt
- 7ExampleDesign the voltage multiplier
- 8Key InsightLink sensitivity to input resistance
- 9ChallengeSeparate coil and added resistance
- 10ExampleFind the voltage before measurement
- 11ExampleCalculate signed error
- 12ExampleInclude the ammeter’s series resistance
- 13ChallengeJudge two voltage ranges
- 14RecapSeparate connection, range, and disturbance
4Balance a bridge and read a sensor change
11 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionCompare the midpoint potentials
- 2ExplanationFix the bridge labels
- 3ExampleDerive the opposite-arm products
- 4ExampleUse the adjustable resistance
- 5ChallengeTest before removing the detector
- 6ExplanationMeasure a difference without drawing current
- 7ExampleLet the sensor resistance increase
- 8Key InsightKeep the small-change condition
- 9ChallengePredict the sign of a decrease
- 10ChallengeSeparate balance from excitation drift
- 11RecapChoose the balance or output equation
5Transform a bridge and recover its original currents
16 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionChange the internal paths
- 2ExplanationRecognize delta and wye topology
- 3Key InsightTest equivalence at the terminals
- 4ChallengeTrace the open third terminal
- 5ExplanationConvert adjacent edges into an arm
- 6ExampleCheck the first terminal pair
- 7ExplanationUse the opposite arm for the reverse
- 8ChallengeChoose the touching pair
- 9ExampleChoose the upper bridge delta
- 10ExampleReduce the transformed paths
- 11ExampleCarry terminal voltages back
- 12ExampleRecover the cross current and check KCL
- 13TipDo not assign the wye current to a delta edge
- 14ChallengeRecover a new original current
- 15ConnectionCheck the original power total
- 16RecapKeep labels through the replacement
Resistive Circuits practice questions
Set 1: Loads, meters, and terminal behavior10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Connections and first calculations10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Recover values and judge models10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Choose and check a complete method10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 5: Transfer and design checks10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
A
Ammeter
B
Balanced delta or wye
Branch current
Bridge balance
Bridge cross branch
Burden voltage
C
Chained division
COM lead
Conductance
Conductance fraction
Current divider
D
d’Arsonval movement
Delta connection
Delta-to-wye conversion
Differential output
Divider ratio
Downstream loading
E
Equivalent group
Equivalent resistance
Excitation voltage
F
Full-scale current
Full-scale voltage
G
Galvanometer
I
Incoming group current
Input resistance
Internal node
L
Load
Loading sag
M
Meter loading
Multiplier resistor
N
Node
Nominal value
Null measurement
O
Ohmmeter
Ohms-per-volt sensitivity
Open circuit
Open-terminal pair check
Original branch current
P
Parallel connection
Power balance
Power rating
Preserved terminal voltage
R
Reference polarity
S
Sensor bridge
Series connection
Series–parallel reduction
Short circuit
Shunt resistor
Siemens
Signed percent error
Small-change approximation
Strain gauge
T
Tap
Terminal current
Terminal pair
Three-terminal equivalence
Tolerance
U
Undisturbed value
V
Voltage divider
Voltmeter
W
Wheatstone bridge
Working backward
Wye connection
Wye-to-delta conversion
About this lesson
Make your own Study Materials