Resistive Circuits

Learn to simplify networks of resistors and to find any current or voltage in them without writing a full system of equations. Combine resistors in series and parallel, use the voltage-divider and current-divider rules, and see how ammeters, voltmeters and their loading errors work. Measure an unknown resistance with a Wheatstone bridge, read the output of a sensor bridge, and use delta–wye transformations to solve networks that series–parallel steps cannot reduce. Every method comes with fully worked examples and checks by KCL, KVL and power balance.

BeginnerLesson 2 of 8 in Electric Circuits 1 Course

What you will learn

  1. Recognize series and parallel connections, replace them with one equivalent resistance, and reduce a series–parallel network step by step to find every current, voltage and power.
    • Combine resistors in series
      Identify resistors in series, add them to one equivalent resistance, and find the shared current, the voltage across each resistor and the power each one absorbs.
    • Combine resistors in parallel
      Identify resistors in parallel, combine them with reciprocals or conductances, and find the shared voltage, the branch currents and the power in each branch.
    • Simplify a series–parallel network and find every current
      Reduce a resistor network to one equivalent resistance between two chosen terminals, then work back through the steps to find each branch current, each voltage and a power check.
  2. Use the voltage-divider and current-divider rules to find a voltage or current directly, design simple dividers, and account for loads, resistor tolerances and power ratings.
    • Find voltages with the voltage-divider rule
      Derive and apply the voltage-divider rule for two or more series resistors, and choose resistor values that give a required output voltage.
    • Account for loading, tolerance and power in a divider
      Predict how a connected load lowers a divider's output, find the worst-case output from resistor tolerances, and check each resistor's power.
    • Split a current with the current-divider rule
      Derive and apply the current-divider rule for two or more parallel branches, with resistances or with conductances.
    • Use division to analyze a series–parallel circuit
      Find one voltage or current in a series–parallel circuit quickly by reducing only what is needed and then applying voltage and current division in turn.
  3. Connect meters correctly, explain how ammeters and voltmeters are built from a basic meter movement, and estimate how much a real meter disturbs the circuit it measures.
    • Connect ammeters, voltmeters and ohmmeters correctly
      Place each meter in the circuit the right way, interpret the sign of its reading, and avoid the connections that damage meters or give false readings.
    • Build an ammeter or voltmeter from a d'Arsonval movement
      Use a moving-coil meter movement's full-scale ratings to design a shunt for an ammeter and a series multiplier for a voltmeter, and read the resulting scale.
    • Estimate the loading error of a meter
      Model a real meter as a resistor, compute the reading it gives and the percent error, and decide whether a meter is good enough for a circuit.
  4. Explain how a Wheatstone bridge finds an unknown resistance at balance and how an unbalanced bridge turns a small resistance change into a measurable voltage.
    • Balance a Wheatstone bridge to find an unknown resistance
      Derive the balance condition, use it to find an unknown resistor, and simplify a balanced bridge for other calculations.
    • Read the output of an unbalanced bridge
      Compute the output voltage of an unbalanced bridge from two voltage dividers and use it to sense a small change in a sensor's resistance.
  5. Recognize delta and wye connections, convert one into the other, and use the conversion to solve networks that series–parallel reduction cannot simplify.
    • Recognize delta and wye connections
      Identify three-terminal delta (pi) and wye (tee) connections in a network and explain what an equivalent three-terminal network preserves.
    • Convert between delta and wye
      Apply the delta-to-wye and wye-to-delta formulas, including the balanced case, and check a conversion.
    • Solve a bridge network with a delta–wye transformation
      Transform part of a bridge, reduce the result to one equivalent resistance, and work back to the current in every original resistor.

Resistive Circuits study guide

5 chapters

1

Combine resistors in series and parallel

Connections determine which quantities resistors share. A series path carries one current, while parallel branches share a voltage. You will use those facts to replace groups with equivalent resistances, then return to the original circuit to find its internal currents and voltages. Tracing nodes comes before arithmetic: a drawing can change shape without changing its connections. KCL, KVL, and power balance give useful checks on the result.

1.1 Combine resistors in series

Two resistors are in series when their shared node has no other connection. Charge has only one path through that junction, so KCL makes their currents equal. A bend in the wire changes nothing. A third branch at the junction changes the connection, even when the resistors still look end to end.

Replace the string

For a series string, KVL adds the resistor drops:

vs=iR1+iR2+⋯+iRn=i(R1+R2+⋯+Rn).

The equivalent resistance is therefore Req=R1+R2+⋯+Rn. An equivalent resistor draws the same current from the same terminal voltage as the original string. With positive resistances, the sum exceeds every individual resistance. Reordering the resistors leaves that sum and the shared current unchanged.

Find current, voltage, and power

Connect 100 Ω, 220 Ω, and 680 Ω in series across 12 V. First add the resistances:

Req=100+220+680=1000 Ω.

Then apply Ohm's law to the entire string:

i=121000=0.012 A=12 mA.

Use this same current in each original resistor. The drops, measured in the direction of current, are:

  • 100 Ω: v1=0.012(100)=1.2 V.
  • 220 Ω: v2=0.012(220)=2.64 V.
  • 680 Ω: v3=0.012(680)=8.16 V.

Their sum is 12 V. The largest resistance takes the largest drop because the current is the same in all three. If the reference voltage is marked opposite to the drop, its signed value is negative.

Power uses the same shared current:

p1=i2R1=14.4 mW,p2=31.68 mW,p3=97.92 mW.

The resistors absorb a total of 144 mW. The source delivers 12(0.012)=0.144 W, so the power check agrees. A resistor does not use up current: it transfers electrical energy into heat while the steady current continues through the string.

Check the connection and the limits

Trace every point joined by ideal wire as one node. If a wire or another element leaves the junction between two resistors, do not assign them one shared current without checking the branch. For example, connecting a meter or load at the midpoint can stop the pair from being a simple series divider.

A zero-resistance wire in a series string adds zero to its equivalent resistance. An open circuit has a different effect: it breaks the only path, so the current becomes zero. Every finite resistor then has zero drop, and the source voltage appears across the gap. The absence of current does not mean that the voltage across the open gap is zero.

Key Takeaways

  • Series elements share a current and have no branch at their joining node.
  • Add series resistances; add their voltage drops to check KVL.
  • With shared current, the larger resistance absorbs more power.
  • An open series path has zero current; the gap can still have voltage.

1.2 Combine resistors in parallel

Resistors are in parallel when both ends connect to the same two nodes. They share the same voltage, even if the drawing places them far apart. Label the nodes at each end before deciding which resistors can be combined.

Add conductances

KCL adds the branch currents. For a common voltage v,

i=vR1+vR2+⋯+vRn.

Comparing this with i=v/Req gives

1Req=1R1+1R2+⋯+1Rn.

Conductance is G=1/R, measured in siemens (S). Thus parallel conductances add directly. After adding reciprocal resistances, invert the total to obtain resistance; the reciprocal sum itself has units of siemens.

For exactly two branches, the formula becomes

R1∥R2=R1R2R1+R2.

For example, 30 Ω in parallel with 60 Ω gives 20 Ω. For several equal resistors, Req=R/n: four 100 Ω branches give 25 Ω. Product over sum applies to two resistors at a time. For three branches, either use reciprocals or combine a pair and then combine its equivalent with the third.

Work through a parallel group

Place 6 Ω, 12 Ω, and 4 Ω across 12 V. Their conductances add to

Geq=16+112+14=0.5 S.

Hence Req=1/0.5=2 Ω and the source current is 6 A. Each branch has the full 12 V:

i6=12/6=2 A,i12=1 A,i4=3 A.

The currents add to 6 A, as KCL requires. Use the shared voltage to find power:

p6=122/6=24 W,p12=12 W,p4=36 W.

Their sum is 72 W, equal to the source's delivered power. In parallel, the smallest resistance carries the most current and absorbs the most power. This follows from the common voltage; it is the reverse of the power ordering for resistors carrying a common series current.

Use size and limiting checks

A positive-resistance parallel equivalent must be smaller than the smallest branch resistance. Adding another finite positive branch lowers the equivalent. With the voltage held fixed, this raises the total current; it leaves each existing branch current unchanged.

A very large added branch changes the equivalent only slightly. A very small branch dominates it. An open branch carries no current and can be removed. A short across a resistor forces that resistor's voltage and current to zero. The parallel group's equivalent then becomes zero; connecting an ideal voltage source directly across an ideal short has no finite-current solution.

Key Takeaways

  • Parallel resistors share both endpoint nodes and voltage.
  • Add conductances, then invert to find resistance.
  • Product over sum applies to two resistors at a time.
  • The equivalent is smaller than the smallest positive branch.
  • At fixed voltage, adding a branch increases total current.
  • The smallest parallel resistance takes the most current and power.

1.3 Simplify a series–parallel network and find every current

An equivalent resistance belongs to a chosen pair of terminals. Start by marking those terminals and labeling the nodes. Then combine genuine series or parallel groups, redraw, and repeat. Keep a record of each replacement so you can later recover what happens inside it.

Reduce from the inside outward

A 40 V source feeds a 2 Ω resistor leading to node A. From A to the return node there are two branches: one is 12 Ω; the other is 6 Ω followed by an 8 Ω and 24 Ω parallel pair.

Begin with the deepest parallel pair:

8∥24=8(24)8+24=6 Ω.

That equivalent is in series with the branch's 6 Ω resistor, giving 12 Ω. Now the two branches are 12 Ω in parallel, giving 6 Ω. The source sees this in series with 2 Ω:

Req=2+6=8 Ω,is=40/8=5 A.

The original 6 Ω and 8 Ω resistors are not in series: the 24 Ω branch also joins their junction. Combining them first would erase a current split.

Reverse the replacements

The source current flows through the 2 Ω resistor, so its drop is 10 V. That leaves 30 V from A to return. Each 12 Ω branch therefore carries 2.5 A.

In the second branch, the original 6 Ω resistor drops 2.5(6)=15 V. The other 15 V is across both members of the original parallel pair:

i8=15/8=1.875 A,i24=15/24=0.625 A.

Their sum, 2.5 A, matches the current entering that branch. At A, the two branch currents add to the 5 A source current. Each recovered current belongs to the original resistor whose connection you have restored.

The resistor powers are 50 W in 2 Ω, 75 W in the separate 12 Ω branch, 37.5 W in 6 Ω, 28.125 W in 8 Ω, and 9.375 W in 24 Ω. They total 200 W, equal to 40(5) W from the source.

Keep terminals and topology visible

The same network can have different equivalents at different terminal pairs. For a triangle with edges 10 Ω, 20 Ω, and 30 Ω, looking across the 10 Ω edge gives 10∥(20+30)=8.33 Ω. Looking across the 30 Ω edge gives 30∥(10+20)=15 Ω. The third terminal is open in each measurement.

A dangling resistor with one end unconnected carries no steady current. A resistor bypassed by an ideal wire has zero voltage. Remove those inactive parts before reduction, while keeping any terminals needed for the question.

If no genuine series or parallel pair remains, do not force a combination. A five-resistor bridge commonly reaches this point. A delta–wye transformation can change the internal connections and make reduction possible. An equivalent alone gives the behavior at its terminals; it does not list the original branch currents.

Record which quantity survives a replacement

Write the voltage across a replaced parallel group on its two outer nodes. When you restore its members, that voltage applies to every member. Write the current through a replaced series group on its path; when restored, each member carries that current. This record avoids confusing the 5 A source current, the 2.5 A branch current, and the smaller currents inside the parallel pair.

A KVL check through the second branch gives 10+15+15=40 V. Choose either the 8 Ω or 24 Ω path for the final drop; do not add their voltages together, because they describe alternative parallel routes.

Key Takeaways

  • Mark the terminals and reduce genuine groups one replacement at a time.
  • Reverse the replacements to recover original currents and voltages.
  • Check junction currents, loop drops, and total power.
  • A bridge may need a transformation before reduction can continue.
2

Divide voltage and current

A resistor network can divide a source voltage or split an incoming current. The useful rule depends on the connection: voltage division follows a series path, and current division follows parallel branches. You will choose divider ratios, account for a connected load, and check tolerance and power. In larger networks, each divider acts on a whole equivalent group before you move inward to the resistor whose voltage or current you need.

2.1 Find voltages with the voltage-divider rule

A voltage divider uses a shared series current to split a source voltage. The output is the voltage across a selected resistor or group of consecutive resistors. Mark the output terminals first; they determine which resistance belongs in the numerator.

Derive the ratio

With two series resistors across a source,

i=vsR1+R2.

Taking the output across the lower resistor gives

vo=iR2=vsR2R1+R2.

For a longer string, the drop across any one resistor is

vk=vsRkR1+R2+⋯+Rn.

Voltage divides in proportion to resistance. Across positive resistances, each drop lies between zero and the total applied voltage. A passive divider cannot produce a larger voltage than its source.

Read drops and tap voltages

For 24 V across 10 kΩ above 5 kΩ, the output across the 5 kΩ resistor is 24(5/15)=8 V. The upper resistor drops 16 V. The 5 kΩ resistor goes in the numerator because it lies between the output terminals, not because it happens to be labeled second.

Now connect 1 kΩ, 2 kΩ, and 3 kΩ in that order from a 12 V positive terminal to return. The total is 6 kΩ, so the current is 2 mA. The individual drops are 2 V, 4 V, and 6 V. Measured from return, the lower junction is at 6 V and the upper junction at 10 V. A tap voltage includes all resistance between that tap and the reference node; it need not equal the drop across just one resistor.

Choose a divider

To obtain a chosen output across the lower resistor, rearrange the two-resistor rule:

R1=R2(vsvo−1).

For 12 V down to 5 V, choosing 10 kΩ for the lower resistor gives R1=10(12/5−1)=14 kΩ. The total current is 0.5 mA. Scaling both resistors down by ten, to 1.4 kΩ and 1 kΩ, keeps the same ratio and 5 V output but raises the current to 5 mA. The ratio sets the output; the scale sets current and power.

Check the midpoint and polarity

The simple rule requires the resistors to carry the same current. A load drawing current from their junction breaks that condition for the original pair. Replace the lower resistor and its load with their parallel equivalent before dividing.

With the source positive at the top, the junction is positive relative to return. Reversing the output reference polarity gives the negative of that voltage. This sign change describes the same physical circuit. A useful numerator check is that an output taken across the smaller resistor must be less than half the source voltage.

Key Takeaways

  • Put the resistance across the output in the voltage-divider numerator.
  • A tap voltage depends on its reference node.
  • Scaling both resistances preserves the unloaded ratio but changes current.
  • A simple divider needs equal current through its series resistors.
  • Reverse the output reference polarity to reverse its sign.

2.2 Account for loading, tolerance and power in a divider

A divider's output depends on everything connected to its midpoint. A load across the lower resistor adds a parallel path, changes the branch resistance, and increases the current through the upper resistor. Real resistor tolerances and power limits also matter when you choose values.

Include the load before dividing

For a load across the lower resistor,

Rb=R2∥RL,vo=vsRbR1+Rb.

The upper resistor is in series with the whole lower parallel group. Because a finite positive load makes that group smaller than the original lower resistor, the output falls.

With 24 V and two 10 kΩ divider resistors, the unloaded output is 12 V. Add a 10 kΩ load: the lower equivalent becomes 5 kΩ, giving vo=24(5/15)=8 V. The upper current is 16/10 kΩ=1.6 mA. It splits into 0.8 mA through each lower branch.

A 100 kΩ load instead gives about 11.43 V, 4.8% below the unloaded output. A 1 MΩ load gives about 11.94 V, 0.5% low. These percentages belong to this equal-resistor example. A load much larger than the lower divider resistor produces less sag.

Choose current and power deliberately

Reducing both divider resistances keeps their unloaded voltage ratio but makes the output less sensitive to a given load. The cost is more source current and more resistor heating. Larger resistors save power but allow greater output change under the same load. Dividers suit small-current reference, bias, sensor, and measurement inputs; a changing substantial load makes the output vary.

Calculate each resistor's power in the circuit actually connected. Use p=i2R with that resistor's current, or p=v2/R with its voltage. The upper current is not generally the lower-resistor current once a load is present.

Find tolerance extremes

Tolerance gives the allowed deviation from a marked resistance. For the lowest output, take the upper resistance at its maximum and the lower at its minimum. Reverse those choices for the highest output. Equal percentage changes in both resistors leave the ratio unchanged.

For 20 V across 15 kΩ above 5 kΩ, each with ±5% tolerance, the nominal output is 5 V. The extremes are

vmin=204.7515.75+4.75≈4.63 V, vmax=205.2514.25+5.25≈5.38 V.

The nominal current is 1 mA, giving 15 mW and 5 mW in the two resistors. Both are below a 0.25 W rating. Common small-resistor ratings include 0.125 W, 0.25 W, and 0.5 W. Check the relevant worst operating case as well as the nominal case before selecting a rating.

Track power after the load is attached

In the 24 V, equal-10 kΩ example with a 10 kΩ load, the upper resistor has 16 V across it and absorbs 162/10 000=25.6 mW. The lower resistor and load each have 8 V and absorb 6.4 mW. Together they absorb 38.4 mW, matching the source's 24(0.0016)=38.4 mW.

The unchanged marked resistances do not imply unchanged heating. Connecting the load increases upper-resistor power while decreasing the original lower-resistor power. Evaluate ratings component by component instead of dividing total power equally.

Key Takeaways

  • Combine a load in parallel with the lower resistor before dividing.
  • Smaller divider resistors reduce sag at the cost of current and power.
  • Opposite tolerance extremes produce the extreme divider outputs.
  • Calculate each resistor’s power using its own loaded voltage or current.
  • A divider output changes with its load.

2.3 Split a current with the current-divider rule

A current divider splits an incoming current among parallel branches. The branch voltages agree, while their currents depend on their resistances. Start with the total current entering the parallel group, which may be only part of the current from a larger circuit.

Use the common voltage

If the parallel equivalent is known, its voltage is v=isReq. Ohm's law then gives any branch current:

ik=vRk=isReqRk.

This works for two, three, or more parallel branches. In conductance form,

ik=isGkG1+G2+⋯+Gn.

A larger conductance takes a larger share. Equivalently, a smaller resistance takes more current. This inverse relationship is a useful check before calculating.

Apply the two-branch shortcut

For two resistors, substitute their product-over-sum equivalent into the general rule:

i1=isR2R1+R2,i2=isR1R1+R2.

The other branch's resistance appears in the numerator. This is different from voltage division, where the numerator is the resistance across which the voltage is required.

Suppose 6 mA enters 2 kΩ in parallel with 4 kΩ. The 2 kΩ branch receives 6(4/6)=4 mA, and the 4 kΩ branch receives 2 mA. Their currents sum to 6 mA. Both give the same branch voltage: 4 mA(2 kΩ)=2 mA(4 kΩ)=8 V.

Using the branch's own resistance in the numerator would swap these currents. It would also predict more current in the higher resistance despite an equal voltage, which conflicts with Ohm's law.

Extend to more branches

Let 12 A enter 6 Ω, 12 Ω, and 4 Ω in parallel. Their equivalent is 2 Ω, so the group voltage is 24 V. The general rule gives

i6=1226=4 A,i12=12212=2 A,i4=1224=6 A.

KCL checks the total: 4 A plus 2 A plus 6 A equals 12 A. Do not put three resistances into the two-branch shortcut. You can instead combine the branches other than the target into one equivalent and use that as the other branch.

Reference arrows still control signs. If a requested arrow points against the actual current, report a negative value. The physical split is unchanged. The voltage-divider and current-divider rules both come from Ohm's law and a shared quantity: common current in series, common voltage in parallel.

Combine the other branches when useful

In the three-branch example, suppose only the 4 Ω current is wanted. The other two resistors combine to 6∥12=4 Ω. The target 4 Ω branch and this 4 Ω equivalent then split the 12 A equally, giving 6 A to the target. The current in the other equivalent is a total that will split again if its internal currents are needed.

This approach explains what the two-branch formula is dividing. Its numerator can represent several original resistors, provided they have been correctly combined into the single opposing branch between the same two nodes.

Key Takeaways

  • Current splits in proportion to conductance.
  • The two-branch numerator is the other branch’s resistance.
  • For any number of branches, multiply total group current by equivalent resistance over target resistance.
  • Branch currents must sum to the incoming group current.

2.4 Use division to analyze a series–parallel circuit

A target resistor in a larger network may not belong to a simple divider until you replace surrounding groups. Reduce enough of the circuit to expose a valid division step. Then move back toward the target, using the voltage or current of the group that contains it.

Divide between whole groups

A 36 V source feeds an 8 Ω resistor. After it, the circuit splits into a 24 Ω branch and a branch containing 4 Ω followed by 8 Ω. Find the voltage across the 8 Ω resistor inside that second branch.

The second branch is 12 Ω. Combining the two branches gives

Rp=24∥12=8 Ω.

The source now sees two equal series groups: the original 8 Ω resistor and the 8 Ω parallel equivalent. Their shared voltage division gives

vp=3688+8=18 V.

Restore the second branch. Its 4 Ω and 8 Ω resistors share 18 V, so the target voltage is

v8=1884+8=12 V.

The first numerator represents the whole parallel group; the second represents one original resistor within a branch. Each denominator is the total series resistance at that particular stage.

Check through current division

The source sees 16 Ω and supplies is=36/16=2.25 A. That current enters the 24 Ω and 12 Ω parallel branches. The 12 Ω branch receives

i12=2.252424+12=1.5 A.

The original 8 Ω target therefore drops 1.5(8)=12 V, agreeing with the voltage route. The 24 Ω branch carries 0.75 A; the sum is 2.25 A. The voltage route can be shorter when only one output voltage is wanted, while the current route gives useful branch currents along the way.

Preserve downstream loading

A tempting incorrect first step is to divide 36 V between the original 8 Ω and the 24 Ω branch alone. That gives 27 V across the branch but ignores the other current path. The original 8 Ω carries the sum of both branch currents, so it is not in series with either branch separately.

Several divider ratios can be multiplied:

v8=36(816)(812)=12 V.

The earlier ratio must include the equivalent resistance of everything connected downstream. Two divider stages joined at a midpoint generally load each other. Do not multiply their separate unloaded ratios unless the connections really preserve those ratios. On the redrawn circuit, check series current equality or shared parallel nodes before each division.

Use the chosen route to check signs and bounds

In the worked network, the 4 Ω resistor drops 1.5(4)=6 V. The two drops inside that branch are therefore 6 V and 12 V, adding to its 18 V. The source-side 8 Ω drops the other 18 V. A loop through the target branch checks as 18+6+12=36 V.

The target's 12 V must be less than its branch's 18 V, which must be less than the positive source's 36 V. These bounds follow from the positive resistor values and the chosen drop directions. They can expose an incorrect ratio without calculating every other current.

Key Takeaways

  • Divide between whole equivalent groups before working inward.
  • Every chained ratio must include the load of everything downstream.
  • Current division and voltage division can provide independent routes to a target.
3

Measure voltage, current and resistance

A meter becomes part of the circuit it measures. Its connection determines whether it samples a voltage, carries a current, or tests a resistance. Ideal meters make the basic method clear; real meter resistances explain why a reading can change when the meter is connected. You will also build current and voltage ranges around a moving-coil movement, then calculate whether the resulting loading error is acceptable for a measurement.

3.1 Connect ammeters, voltmeters and ohmmeters correctly

An ammeter measures current through a path; a voltmeter measures the potential difference between two nodes. Their names tell you the quantity, but their internal resistance explains how to connect them and how they affect the circuit.

Put each meter in the right place
MeterConnectionIdeal resistanceIdeal effect
AmmeterIn series with the measured pathZeroNo added voltage drop
VoltmeterAcross the measured nodesInfiniteNo current drawn

For current, open the path and insert the ammeter so the branch current passes through it. For voltage, leave the circuit path intact and attach the voltmeter across the two nodes. A real current meter adds a small series resistance. Its resulting drop is called the burden voltage. A real voltage meter adds a large but finite parallel resistance; a common digital DC-voltage input is about 10 MΩ.

Never connect an ammeter directly across a source: its low resistance can produce a damaging current. For resistance measurements, switch off circuit power and disconnect at least one end of the resistor before connecting the ohmmeter.

Read the sign

A digital voltmeter reads positive when its red voltage lead is at a higher potential than COM. A current reading is positive when current enters the red current lead. Swapping the leads reverses the reading's sign. For example, a reading of −3 V means the red lead is 3 V below COM; the magnitude of the potential difference is still 3 V.

This is the same reference-direction idea used in a calculation. A negative current tells you that actual current flows opposite to the marked reference arrow. It does not mean that the meter has found a negative resistance.

Diagnose a wrong connection

A voltmeter inserted in series adds its large resistance to the current path. With a 9 V source, a 1 kΩ resistor, and a 10 MΩ voltmeter all in series,

i=910 001 000≈0.9 μA.

The voltmeter then reads about 8.999 V. Almost the full source voltage appears across the meter, while the resistor receives only about 0.0009 V. A plausible-looking meter reading can therefore belong to a circuit that the connection has greatly changed.

Measure a resistor separately

An ohmmeter supplies a small test current or voltage and infers resistance from the response. If a resistor remains connected to other paths, the reading is their combined resistance. A 10 kΩ resistor with a second 10 kΩ path across it reads 5 kΩ, even if the first resistor is correct. Isolating one end removes that alternate path. The resistance reading then belongs to the component whose value you intend to check.

Distinguish a lead reversal from a topology change

Reversing voltage leads on the same pair of nodes changes only the reference polarity. Moving a lead to another node changes the physical voltage being measured. Likewise, reversing the reference arrow for an already known branch current changes its signed description, while inserting a meter into a different branch measures a different current.

The ideal models clarify the connection test: a zero-resistance ammeter can replace a small piece of wire in the intended path, while an infinite-resistance voltmeter adds no conducting path across its measured nodes.

Key Takeaways

  • Insert an ammeter in series; connect a voltmeter across two nodes.
  • An ideal ammeter has zero resistance; an ideal voltmeter draws no current.
  • A negative reading reverses the connected reference direction.
  • An ohmmeter tests resistance with its own excitation.
  • Other connected paths can lower a resistance reading.

3.2 Build an ammeter or voltmeter from a d'Arsonval movement

A d'Arsonval movement, also called a moving-coil movement, deflects a pointer in proportion to coil current. Its full-scale current and voltage describe the largest normal scale reading. External resistors turn that sensitive movement into meters with useful ranges.

Start with the movement

A movement rated at 1 mA and 50 mV has coil resistance

Rc=vfsifs=0.050.001=50 Ω.

Both ratings describe the same full-scale operating point. At half that current, the pointer is halfway along a linear scale.

Extend the current range

An ammeter uses a shunt in parallel with the coil. The shunt carries the part of the measured current that the coil cannot carry. At full scale, both paths have the movement's full-scale voltage:

Rsh=vfsIrange−ifs.

For a 1 A range, the shunt current is 0.999 A and

Rsh=0.05/0.999≈0.05005 Ω.

The complete meter's resistance is 50∥0.05005≈0.05 Ω, also obtained from 50 mV divided by 1 A. The shunt resistance and whole-meter resistance are close here, but they are different quantities.

For a 10 mA range with this same movement, the shunt carries 9 mA. It needs 0.05/0.009≈5.56 Ω. Dividing by the entire 10 mA would give 5 Ω and divert too much current from the coil. Subtracting the movement current matters most when the selected range is close to the movement's own range.

Extend the voltage range

A voltmeter uses a multiplier resistor in series with the coil. The desired range voltage must drive exactly the full-scale coil current:

Rm=Vrangeifs−Rc.

On a 150 V range, the total resistance must be 150 kΩ. Subtract the 50 Ω coil to obtain a multiplier of 149 950 Ω. Using 150 kΩ as the multiplier would count the coil resistance twice in the total.

Relate range, sensitivity, and reading

Voltmeter sensitivity is 1/ifs in ohms per volt. The 1 mA movement has 1000 Ω/V sensitivity. A 50 µA movement has 20 kΩ/V sensitivity. Multiply sensitivity by the selected full-scale voltage to obtain total input resistance.

A pointer at 40% of the 150 V scale reads 60 V and carries 0.4 mA in the coil. A multirange analog meter selects different shunts or multipliers. Digital meters use the same resistor ideas, with an analog-to-digital converter replacing the pointer movement.

Check the full-scale paths

For the 1 A ammeter, the shunt and coil currents must add to exactly 1 A. Their voltage drops must also agree: 0.999(0.05005)≈0.05 V and 0.001(50)=0.05 V. These are KCL and the parallel-voltage condition applied to the meter itself.

For the 150 V voltmeter, the 1 mA current gives 149.95 V across the multiplier and 0.05 V across the coil. The drops total 150 V. This check distinguishes the added resistor from the complete instrument and catches a multiplier that forgot to subtract the coil resistance.

Check the added resistors' power

At the 1 A ammeter limit, the shunt absorbs psh=vfs(Irange−ifs)=0.05(0.999)=49.95 mW. The coil absorbs another 0.05 mW. Their total, 50 mW, matches the complete meter's terminal power of 50 mV times 1 A.

In the 150 V voltmeter, the multiplier absorbs 149.95(0.001)=149.95 mW while the coil still absorbs 0.05 mW. Choosing a resistance value establishes a range, but the added resistor must also have a suitable power rating. Use the current and voltage of the added resistor itself, not the entire range current through a shunt or the entire range voltage across a multiplier.

Key Takeaways

  • Movement resistance is full-scale voltage divided by full-scale current.
  • A shunt carries the range current minus the coil current.
  • A multiplier adds enough series resistance for the chosen voltage range.
  • Sensitivity is the reciprocal of full-scale current.
  • Total voltmeter resistance equals sensitivity times range.
  • A linear-scale reading equals range times deflection fraction.

3.3 Estimate the loading error of a meter

A real meter measures the circuit with that meter connected. Its resistance changes the circuit, so the reading can differ from the true value, meaning the value before connection. This difference is loading error, even when the meter itself is accurately calibrated.

Model a voltmeter as a parallel resistor

A 50 V source feeds two 100 kΩ series resistors. Before measurement, the lower resistor has 25 V across it. Connect a 150 kΩ voltmeter across it:

Rb=100∥150=60 kΩ.

The upper resistance stays 100 kΩ, giving

vread=5060100+60=18.75 V.

The meter reads the loaded output, not the original 25 V. Define signed percentage error as

error=measured−truetrue×100%.

Here the error is [(18.75−25)/25](100%)=−25%. The negative sign identifies a low reading; the error magnitude is 25%.

A 10 MΩ digital meter in the same circuit gives 100 kΩ∥10 MΩ≈99.01 kΩ. The reading is about 24.88 V, or 0.5% low. Its larger input resistance draws much less current from the midpoint.

Model an ammeter as a series resistor

A 10 V source across 100 Ω produces 100 mA without a meter. Inserting a 5 Ω ammeter raises the total to 105 Ω:

iread=10/105≈95.24 mA.

The error is about −4.76%. For this circuit, a smaller ammeter resistance would disturb the current less. Its burden voltage is the measured current times its resistance, about 0.476 V here.

Judge the resistance ratio

In passive resistor circuits supplied by independent ideal sources, a voltmeter resistance at least 100 times the resistor being measured gives less than about 1% loading error. The surrounding passive resistance can further reduce the resistance seen at the measurement terminals. For an exact error, use the whole circuit and recompute the loaded value.

For an ammeter, compare its resistance with the full path resistance that its insertion increases. Voltage loading is especially noticeable in high-resistance networks; current loading is especially noticeable in low-resistance paths.

For an analog voltmeter, input resistance equals sensitivity times range voltage. Selecting a higher voltage range increases its input resistance and reduces loading. The pointer then occupies a smaller fraction of the scale, making its position harder to read precisely. Choosing a range therefore involves both circuit disturbance and scale resolution.

Separate circuit error from scale error

Loading calculations predict a changed physical value. Better scale resolution alone cannot restore the voltage or current that existed before connection. A meter of the same resistance with finer display digits still imposes the same load.

For the analog example, the meter draws 18.75/150 kΩ=0.125 mA. The original lower resistor draws 0.1875 mA, while the upper resistor carries their 0.3125 mA sum. This extra current through the upper resistor produces its larger drop. Tracing that split explains the low reading without treating the meter as faulty.

Key Takeaways

  • Model a voltmeter in parallel and an ammeter in series.
  • Loading error compares the connected reading with the value before connection.
  • A higher voltmeter resistance and a lower ammeter resistance reduce disturbance.
  • An analog voltage range changes both input resistance and scale use.
4

Measure resistance with a Wheatstone bridge

A Wheatstone bridge compares two voltage-divider outputs. At balance the midpoint voltages agree, so a zero detector reading lets you determine an unknown resistance from a ratio. Away from balance, the difference between those voltages can reveal a small sensor resistance change. You will keep the resistor labels and output polarity explicit, because reversing either changes the equation or the sign of the answer.

4.1 Balance a Wheatstone bridge to find an unknown resistance

A Wheatstone bridge compares two resistor ratios by detecting a zero current between their midpoints. Keep one labeling scheme throughout: source positive at a, return at b, left midpoint c, and right midpoint d. The arms are R₁ from a to c, R₃ from c to b, R₂ from a to d, and Rₓ from d to b.

Find the balance condition

A sensitive galvanometer connects c to d. At balance it carries zero current because the midpoints have equal potentials. Each side then acts as an unloaded voltage divider:

vc=vsR3R1+R3,vd=vsRxR2+Rx.

Set these equal, cancel the nonzero source voltage, and cross-multiply:

R3(R2+Rx)=Rx(R1+R3).

The common product cancels, leaving

R1Rx=R2R3,Rx=R2R3R1.

The products of opposite arms agree. Equivalently, the upper-to-lower resistance ratio is the same on both sides. Balance does not require all four resistors to be equal.

Measure the unknown

Take 100 Ω for R₁ and 1000 Ω for R₂. Adjust R₃ until the detector reads zero; suppose balance occurs at 472 Ω. Then

Rx=1000(472)/100=4720 Ω=4.72 kΩ.

The ratio of the two top arms multiplies the adjustable resistance by ten. Detector deflection on either side of zero tells you which way the midpoint difference points; adjustment brings that difference to zero.

Neither the source voltage nor detector resistance appears in the ideal balance equation. Source magnitude affects detector response away from balance, but it does not change the resistance ratio at the null. Measurement accuracy still depends on the known resistor values and how well the detector resolves a small departure from zero.

Simplify a balanced bridge

At balance, the detector branch has zero voltage and current. Removing it leaves the rest unchanged. The resistance between a and b in the example is

(100+472)∥(1000+4720)=520 Ω.

Joining c and d with an ideal wire also leaves the other currents unchanged at this balance point. The equivalent can then be found as

(100∥1000)+(472∥4720)=520 Ω.

An unbalanced bridge does not permit either replacement without changing its behavior. Check the ratio before removing the cross branch.

Ordinary balanced bridges are typically useful from about 1 Ω to 1 MΩ. Below about 1 Ω, lead and contact resistance can become a substantial part of the reading. Kelvin double bridges separate those effects in low-resistance measurement.

Check the measured ratio directly

In the balanced example, R1/R3=100/472 and R2/Rx=1000/4720 are equal. Each midpoint is therefore the same fraction of the source voltage above b. The two side currents need not be equal: the right side has ten times the total resistance and one tenth of the left-side current.

Zero detector current is a comparison between midpoint potentials. It does not say that the bridge draws no source current. Each complete side still forms a conducting path from a to b, which is why the input equivalent remains finite.

Key Takeaways

  • Balance means equal midpoint potentials and zero detector current.
  • With the defined labels, opposite-arm products agree at balance.
  • At balance, source voltage and detector resistance drop out of the resistance ratio.
  • Only a balanced cross branch can be removed without changing the other currents.
  • Known resistor accuracy and detector resolution affect the measurement.

4.2 Read the output of an unbalanced bridge

A sensor bridge turns a resistance change into a difference between midpoint voltages. Use the same arms as the balanced bridge: R₁ above R₃ on the left, R₂ above Rₓ on the right, and source voltage from a to b. Define the output from c to d, so vcd=vc−vd.

Subtract the two divider outputs

With an output instrument that draws negligible current, the two sides remain unloaded dividers:

vcd=vs(R3R1+R3−RxR2+Rx).

A strain gauge, thermistor, resistance temperature detector, or photoresistor can occupy the sensor arm. Set the bridge to balance at a reference condition. A change in the sensor resistance then moves its midpoint away from the other midpoint.

For 5 V excitation and three fixed arms of 1 kΩ, let the lower-right sensor rise to 1010 Ω. The left midpoint remains at 2.5 V. The right midpoint becomes

vd=510101000+1010≈2.51244 V.

Subtracting in the defined order gives vcd≈−12.44 mV. The negative sign means d is above c. With positive excitation in this arrangement, increasing the lower-right sensor raises the right midpoint and makes this output negative.

Estimate a small change

For equal nominal arms of resistance R and sensor resistance R+ΔR, the exact expression simplifies to

vcd=−vsΔR2(2R+ΔR).

When ∣ΔR∣≪R, its magnitude is approximately

∣vcd∣≈∣vs∣ ∣ΔR∣4R.

The example gives a 12.5 mV approximation, close to 12.44 mV. For a large change, retain the exact denominator. If the sensor doubles to 2 kΩ, the exact magnitude is about 0.833 V; the small-change expression would give 1.25 V and substantially overestimate it.

Interpret what the bridge removes

The sensor-side divider alone has a midpoint near 2.5 V, with a small useful change on top. Subtracting the fixed-side midpoint removes that reference offset, so the bridge output begins at zero and can be amplified to show a small change.

In unbalanced operation, the output is proportional to excitation voltage. A stable excitation helps keep a sensor reading stable. This differs from a balanced resistance measurement, where the source voltage cancels from the null condition.

A finite-resistance detector draws current between the midpoints and loads both dividers. The separate divider equations then no longer describe their voltages. Treat the detector as a fifth resistor and solve the resulting network, for example by delta–wye conversion.

Separate a resistance change from its cause

The bridge equation converts the sensor resistance into a voltage; it does not by itself convert voltage into temperature, strain, or light level. That next conversion needs the sensor's resistance relationship to the measured quantity. A positive or negative output can identify the direction of resistance change once the arm position and polarity are fixed.

The left and right midpoint voltages remain much larger than their difference in the small-change example. Subtracting those potentials is therefore a different measurement from reading either midpoint against the return node.

Key Takeaways

  • A negligible-current output reads the difference of two divider voltages.
  • Output sign depends on the sensor position and reference polarity.
  • The linear small-change estimate requires a change much smaller than the nominal resistance.
  • Unbalanced output scales with excitation voltage.
  • A finite detector resistance loads the bridge.
5

Transform delta and wye networks

Some resistor networks have no series or parallel pair to combine. Delta–wye transformations replace a three-terminal group with a different internal connection that behaves the same at those terminals. You will identify valid groups, convert their resistances, and reduce the new circuit. The final step returns to the original network: terminal voltages transfer across the replacement, but currents inside the replacement need not match original branch currents.

5.1 Recognize delta and wye connections

A delta connects three resistors in a closed triangle between three terminals. A wye connects each of three terminals to a shared center through one resistor. Their shapes can be redrawn; the connections, not the outline on the page, identify the network.

Recognize the same connections in new shapes

A delta is also called a triangle or mesh. A pi network is the same delta topology drawn with an upper crosspiece and two side arms. A wye is also called a star, and a tee network is the same wye topology drawn as a T.

Label the outer terminals 1, 2, and 3. In a delta, each resistor has a terminal pair as its endpoints. In a wye, each resistor has one outer terminal and the shared center as its endpoints. A valid wye center joins exactly those three resistors and no external branch. An extra connection at the center would create a fourth accessible terminal and prevent the three-terminal replacement.

Understand equivalence

Equivalent delta and wye networks have the same resistance between every pair of terminals when the third terminal is left open. For terminals 1 and 2, the wye path contains its first two arms in series. Its third arm is dangling and carries no current. In the delta, the direct 1–2 edge is in parallel with the two-edge path through terminal 3.

Matching all three terminal-pair resistances makes the networks behave identically for any external circuit connected to those terminals. External terminal voltages and currents agree. The wye center, however, is an internal node with no counterpart in the delta, and individual resistor currents need not agree between the two forms.

Find a transformable group in a bridge

In a five-resistor bridge, let a be the top node, b the bottom node, and c and d the midpoints. The cross resistor runs from c to d. The upper three resistors form the delta a–c–d; the lower three form the delta c–d–b. There is also a wye centered at c and another centered at d.

Transforming one of these groups can create a new series or parallel pair. A delta-to-wye conversion adds an internal center node. A wye-to-delta conversion removes its internal center node. Preserve each of the three outer terminal labels while redrawing, so every external branch stays connected to the same terminal.

The replacement helps solve the external network, but it does not assign original internal currents. After calculating terminal voltages, restore the original delta or wye and use those endpoint voltages with Ohm's law. A current in a newly created arm is a current in the replacement network only.

Key Takeaways

  • Delta and wye are three-terminal topologies, regardless of drawing shape.
  • A wye center must have no external connection.
  • Equivalence preserves all terminal voltages and currents.
  • Internal branch currents need to be recovered in the original network.

5.2 Convert between delta and wye

Delta–wye formulas depend on terminal labels. Let the delta edges be R₁₂, R₂₃, and R₃₁. Let each wye arm R₁, R₂, or R₃ run from its numbered terminal to the center. Write those labels on the drawing before substituting values.

Convert delta to wye

Let the sum of all delta resistances be S=R12+R23+R31. Each wye arm uses the two delta edges touching its outer terminal:

R1=R12R31S,R2=R12R23S,R3=R23R31S.

For delta edges 20 Ω, 30 Ω, and 50 Ω in that order, the sum is 100 Ω. The wye arms are

R1=20(50)/100=10 Ω, R2=20(30)/100=6 Ω,R3=30(50)/100=15 Ω.

Notice that the arm at terminal 1 uses edges 1–2 and 3–1. The edge 2–3 is opposite that terminal and appears only in the denominator sum.

Convert wye to delta

Form the sum of pairwise products:

P=R1R2+R2R3+R3R1.

Then divide by the arm at the terminal opposite the desired delta edge:

R12=P/R3,R23=P/R1,R31=P/R2.

For arms 10 Ω, 6 Ω, and 15 Ω, the product sum is 60+90+150=300 Ω2. The delta edges become 20 Ω, 30 Ω, and 50 Ω, recovering the original values. An equivalent expression for the first edge is R12=R1+R2+R1R2/R3.

Check what the terminals see

With terminal 3 open, the wye gives R1+R2=16 Ω between terminals 1 and 2. The delta gives 20∥(30+50)=16 Ω. The other two terminal pairs give the same agreement. This terminal-pair comparison is also the basis of the conversion formulas: equate the resistances for all three pairs and solve the resulting relationships.

For a balanced network with three equal delta edges, each wye arm is one third of a delta edge. Conversely, each balanced delta edge is three times a wye arm. Three 30 Ω delta edges therefore become three 10 Ω wye arms; their pair resistance is 20 Ω in either form.

For positive resistances, each converted wye arm is smaller than either adjacent delta edge. Each converted delta edge is larger than the sum of the two wye arms at its ends. These checks can catch a wrong product or opposite-arm denominator before the converted circuit is reduced.

Keep the opposite-arm label explicit

For a wye-to-delta edge between terminals 1 and 2, terminal 3 is the opposite terminal, so its arm divides the product sum. A direct size check follows from R12=R1+R2+R1R2/R3: the extra term is positive, so the delta edge exceeds the endpoint-arm sum.

For delta to wye, the denominator sum exceeds either adjacent delta edge. The product divided by that sum is therefore smaller than each edge in the numerator. These checks test the label assignment as well as the numerical scale.

Derive one arm from the three pair measurements

Write the open-third-terminal pair resistances as E12, E23, and E31. In the wye they are R1+R2, R2+R3, and R3+R1. Adding the first and third and subtracting the second isolates the first arm:

R1=E12+E31−E232.

For the delta, E12=R12(R23+R31)/S. Substitute the corresponding expressions for all three pairs into the isolated-arm equation. The mixed products involving the opposite edge cancel, leaving R1=R12R31/S. This explains why the numerator uses the edges touching terminal 1: that arm appears in the two pair paths that include terminal 1, but not in the remaining pair path.

Key Takeaways

  • A wye arm is the adjacent delta-edge product divided by the delta sum.
  • A delta edge is the pairwise wye-product sum divided by the opposite arm.
  • Check terminal-pair resistance with the third terminal open.
  • Balanced delta edges are three times balanced wye arms.
  • Use size bounds to catch label or arithmetic errors.

5.3 Solve a bridge network with a delta–wye transformation

A bridge with a finite cross resistor generally has no series or parallel pair. Convert a valid three-terminal group, reduce the replacement, and then recover original currents from the unchanged terminal voltages. Keep the original drawing beside the transformed one.

Transform the upper triangle

A 40 V source connects a to return b. The original edges are 20 Ω from a to c, 50 Ω from a to d, 30 Ω from c to d, 14 Ω from c to b, and 5 Ω from d to b.

The upper delta a–c–d has a 100 Ω sum. Convert it to arms from a, c, and d to a new center o:

Ra=20(50)/100=10 Ω, Rc=20(30)/100=6 Ω,Rd=30(50)/100=15 Ω.

The external 14 Ω and 5 Ω resistors remain connected to c and d.

Reduce and find terminal voltages

From o to b, one branch is 6+14=20 Ω and the other is 15+5=20 Ω. They are in parallel and give 10 Ω. Adding the arm from a gives

Req=10+(20∥20)=20 Ω.

The source current is 2 A. The equal lower branches each carry 1 A. Measured from b, the unchanged lower resistors give

vc=1(14)=14 V,vd=1(5)=5 V.

These are terminal voltages of the converted group, so they also hold in the original circuit.

Restore the original resistors

Use the actual endpoint difference for each original edge:

iac=(40−14)/20=1.3 A, iad=(40−5)/50=0.7 A, icd=(14−5)/30=0.3 A.

The cross current flows from c to d. The unchanged lower currents remain 1 A each. At c, the incoming 1.3 A equals the outgoing 1 A plus 0.3 A. At d, 0.7 A plus 0.3 A supplies the 1 A lower branch.

The resistor powers are 33.8 W, 24.5 W, 2.7 W, 14 W, and 5 W. They total 80 W, matching 40(2) W delivered by the source.

Distinguish original and replacement currents

The 2 A in the wye arm from a is the total terminal current. In the original delta it splits into 1.3 A and 0.7 A; neither original upper resistor carries 2 A. Equivalence preserves terminal behavior, not a one-to-one match between internal branches.

Other valid conversions also work, including the wye centered at c. Choose a group that creates useful combinations after redrawing. The original 30 Ω cross resistor can represent a finite-resistance bridge detector. Its 0.3 A current shows why the unloaded-divider bridge formula cannot be used for this loaded circuit.

Keep the original and transformed node lists separate

The transformed center o is 20 V above b in the example, because the 2 A source current drops 20 V across the new 10 Ω arm. This helps check the replacement paths: the arm toward c drops 6 V and the arm toward d drops 15 V, giving c = 14 V and d = 5 V.

Only a, c, and d were outer terminals of the replaced group. Their potentials transfer to the original triangle; the 20 V center potential does not name a point in that triangle. Using it as an original endpoint would invent a node and give incorrect original currents.

Check with a different conversion

The original wye centered at c has arms of 20 Ω to a, 30 Ω to d, and 14 Ω to b. Its pairwise-product sum is 20(30)+30(14)+14(20)=1300 Ω2. Converting it gives delta edges a–d of 1300/14 Ω, d–b of 65 Ω, and a–b of 1300/30 Ω.

The new a–d edge is parallel with the original 50 Ω, giving 32.5 Ω. The new d–b edge is parallel with the original 5 Ω, giving 65/14 Ω. Those two equivalents are now in series; their sum is 260/7 Ω. It lies in parallel with the new a–b edge of 130/3 Ω, giving 20 Ω overall. The same input equivalent follows from either conversion, despite different internal replacement paths.

Key Takeaways

  • Preserve the three outer terminal labels during a conversion.
  • Reduce the transformed circuit to find its terminal voltages.
  • Use original endpoint voltages and resistances for original currents.
  • Check recovered currents with KCL and total power.

Resistive Circuits examples

5 Walkthroughs

1

Reduce a network and restore its branch values

14 steps
Trace nodes, combine resistors, and work backward to check original currents and power.
  1. 1
    IntroductionStart with the connections

    A resistor’s position on the page does not determine its connection. Series elements share an unbranched path; parallel elements share two endpoint nodes.

    Reduction replaces a group with one resistor that behaves the same at its terminals. We will first make those replacements, then reverse them to find the currents hidden inside the equivalent.

  2. 2
    ExplanationFind an unbranched junction

    Trace all points joined by ideal wire as one node. Two resistors are in series only when their shared node has no third connection, so they carry one current.

    Their drops add by KVL: vs=iR1+iR2. Factoring out the current gives Req=R1+R2. A third branch at their junction would let current split and remove that simple series relationship.

  3. 3
    ExampleUse the shared series current

    Connect 100 Ω, 220 Ω, and 680 Ω across 12 V. Their total is 1000 Ω, giving i=12/1000=12 mA.

    Multiply that same current by each original resistance: the drops are 1.2 V, 2.64 V, and 8.16 V. They add to 12 V. The increasing drops do not mean current is being used up; each resistor carries 12 mA and absorbs energy at its own rate.

    Use the 680 Ω drop to check its power: 8.16(0.012)=97.92 mW. The voltage in this power calculation belongs to that resistor, while the current belongs to the shared series path.

  4. 4
    ChallengeCheck the biggest series drop

    A 16 V source drives 200 Ω and 600 Ω in series. What voltage is across the 600 Ω resistor?

    ---reveal---

    The total is 800 Ω and the shared current is 20 mA. The requested drop is 0.020(600)=12 V. The other resistor drops 4 V, so the two drops add to 16 V.

  5. 5
    ExplanationTrace both parallel endpoints

    Parallel resistors connect to the same two nodes and share voltage. Their currents add, which gives 1/Req=1/R1+1/R2+⋯.

    The reciprocal sum is conductance in siemens. Invert it to report resistance. For two branches only, product over sum is a shortcut: Req=R1R2/(R1+R2). The result must be smaller than either positive branch resistance.

  6. 6
    ExampleFind currents from common voltage

    Put 6 Ω, 12 Ω, and 4 Ω in parallel across 12 V. Their conductances sum to 0.5 S, so the equivalent is 2 Ω.

    Each branch sees 12 V, giving currents of 2 A, 1 A, and 3 A. Their sum is 6 A, matching 12/2. The smallest resistance takes the largest current because all three have the same applied voltage.

    The branch powers are 24 W, 12 W, and 36 W. They total 72 W, equal to the source’s 12 V times 6 A. Common voltage makes lower resistance mean both greater current and greater heating.

  7. 7
    ChallengeRecognize an equal parallel group

    Five identical 150 Ω resistors are connected between the same two nodes. What is their equivalent, and what happens if one branch opens?

    ---reveal---

    Initially the equivalent is 150/5=30 Ω. After one opens, four branches remain, giving 150/4=37.5 Ω. Removing a conducting path raises the equivalent; the open branch carries no current.

  8. 8
    ExampleSet up the nested network

    A 40 V source feeds 2 Ω and then node A. From A to return, one branch is 12 Ω. The other is 6 Ω followed by an 8 Ω–24 Ω parallel pair.

    Start with the inner pair: 8∥24=6 Ω. That equivalent is in series with the original 6 Ω, making the entire second branch 12 Ω. The original 6 Ω and 8 Ω were not series elements because 24 Ω also joined their junction.

  9. 9
    ExampleFinish the reduction

    The two paths from A to return are now 12 Ω each, so their equivalent is 6 Ω. Add the source-side 2 Ω to obtain Req=8 Ω.

    The source supplies 40/8=5 A. Keep the intermediate drawings: the single 8 Ω equivalent gives the source current, but it cannot by itself tell you the current in the original 24 Ω resistor.

    The series 2 Ω carries this entire source current. At A, that current will split between the two restored branches; it cannot be assigned unchanged to every original resistor.

  10. 10
    ExampleWork back to node A

    The original 2 Ω resistor carries 5 A and drops 10 V. Therefore node A is 30 V above return.

    Both 12 Ω branches receive those 30 V, so each carries 2.5 A. In the second branch, the original 6 Ω resistor drops 2.5(6)=15 V. The remaining 15 V must lie across the inner parallel pair.

    The inner pair is not across the full 30 V from A. Its feeding 6 Ω drops half of that branch voltage, leaving the 15 V used to restore the pair.

  11. 11
    ExampleRestore the inner branch currents

    Restore 8 Ω and 24 Ω across the known 15 V. Their currents are 15/8=1.875 A and 15/24=0.625 A.

    They add to 2.5 A, matching the current entering that pair. At node A, the two outer currents add to 5 A. These local KCL checks identify the stage of the calculation where a missing split would show up.

    You can also check the shared voltage by multiplying each recovered current by its resistance: 1.875(8)=15 V and 0.625(24)=15 V. A split that failed this test would not represent parallel branches.

  12. 12
    Key InsightCheck the energy rate

    The source delivers 40(5)=200 W. In the original resistors, the powers are 50 W, 75 W, 37.5 W, 28.125 W, and 9.375 W.

    Their sum is also 200 W. Use original branch currents or voltages for this check. Assigning the source current to an internal parallel resistor would overstate its power and violate the junction-current check.

  13. 13
    ChallengeReduce and restore a new target

    A 24 V source feeds 2 Ω, then 12 Ω in parallel with a series pair of 3 Ω and 9 Ω. What current flows through 9 Ω?

    ---reveal---

    The series branch is 12 Ω, so the parallel group is 6 Ω and total resistance is 8 Ω. Source current is 3 A; it splits equally into the two 12 Ω branches. The 9 Ω resistor carries 1.5 A, the current of its whole series branch.

  14. 14
    RecapUse the shared quantity at each step

    For a series group, retain its common current when restoring the resistors. For a parallel group, retain its common voltage.

    Keep terminal labels and the reduction sequence, then check the original circuit with current sums, voltage sums, and total power. If no series or parallel pair exists, a topology-changing equivalent may be needed before reduction can continue.

2

Use divider rules without losing the load

16 steps
Choose the right group, predict loading, and combine voltage and current division.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionChoose the ratio from the connection
  2. 2
    ExplanationDerive the voltage ratio
  3. 3
    ExampleDesign a ratio and choose its scale
  4. 4
    ChallengeFind a tap from the return node
  5. 5
    ExplanationInclude the parallel load
  6. 6
    Key InsightChoose resistance with loading in mind
  7. 7
    ExampleFind the output limits
  8. 8
    ChallengeCheck loaded power
  9. 9
    ExplanationDerive current division
  10. 10
    ExampleCheck the split by common voltage
  11. 11
    ChallengeSplit among three branches
  12. 12
    ExampleExpose the first divider
  13. 13
    ExampleMove inward to the target
  14. 14
    TipKeep downstream resistance in the ratio
  15. 15
    ChallengeCombine loading and internal division
  16. 16
    RecapMatch every ratio to its group
3

Predict what a meter will read

14 steps
Connect meters, build ranges, and calculate how their resistance changes a reading.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionThe meter joins the circuit
  2. 2
    ExplanationConnect by the measured quantity
  3. 3
    ExampleInterpret sign and resistance readings
  4. 4
    ChallengeDiagnose a series voltmeter
  5. 5
    ExplanationRead the movement’s ratings
  6. 6
    ExampleDesign the ammeter shunt
  7. 7
    ExampleDesign the voltage multiplier
  8. 8
    Key InsightLink sensitivity to input resistance
  9. 9
    ChallengeSeparate coil and added resistance
  10. 10
    ExampleFind the voltage before measurement
  11. 11
    ExampleCalculate signed error
  12. 12
    ExampleInclude the ammeter’s series resistance
  13. 13
    ChallengeJudge two voltage ranges
  14. 14
    RecapSeparate connection, range, and disturbance
4

Balance a bridge and read a sensor change

11 steps
Keep labels and output polarity fixed while comparing the two midpoint voltages.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionCompare the midpoint potentials
  2. 2
    ExplanationFix the bridge labels
  3. 3
    ExampleDerive the opposite-arm products
  4. 4
    ExampleUse the adjustable resistance
  5. 5
    ChallengeTest before removing the detector
  6. 6
    ExplanationMeasure a difference without drawing current
  7. 7
    ExampleLet the sensor resistance increase
  8. 8
    Key InsightKeep the small-change condition
  9. 9
    ChallengePredict the sign of a decrease
  10. 10
    ChallengeSeparate balance from excitation drift
  11. 11
    RecapChoose the balance or output equation
5

Transform a bridge and recover its original currents

16 steps
Convert a three-terminal group, reduce the new circuit, and transfer terminal voltages back.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionChange the internal paths
  2. 2
    ExplanationRecognize delta and wye topology
  3. 3
    Key InsightTest equivalence at the terminals
  4. 4
    ChallengeTrace the open third terminal
  5. 5
    ExplanationConvert adjacent edges into an arm
  6. 6
    ExampleCheck the first terminal pair
  7. 7
    ExplanationUse the opposite arm for the reverse
  8. 8
    ChallengeChoose the touching pair
  9. 9
    ExampleChoose the upper bridge delta
  10. 10
    ExampleReduce the transformed paths
  11. 11
    ExampleCarry terminal voltages back
  12. 12
    ExampleRecover the cross current and check KCL
  13. 13
    TipDo not assign the wye current to a delta edge
  14. 14
    ChallengeRecover a new original current
  15. 15
    ConnectionCheck the original power total
  16. 16
    RecapKeep labels through the replacement

Resistive Circuits practice questions

50 Practice Questions in 5 sets

Set 1: Loads, meters, and terminal behavior10 Practice Questions

Question 1 of 10

A 6 V source drives a 300 Ω resistor. Inserting a 20 Ω ammeter changes the current. What is its signed loading error?
  1. −6.25%
  2. +6.67%
  3. −6.67%
  4. +6.25%
Show answerHide answer
Answer: A
The undisturbed current is 20 mA, while the connected reading is 6/320=18.75 mA. Error is 100(18.75−20)/20=−6.25%. Dividing the resistance increase by 300 Ω gives 6.67%, which is not the percentage decrease in current.

Question 2 of 10

A bridge is supplied with 8 V from top to return. Its left arms are 3 kΩ above 1 kΩ; its right arms are 2 kΩ above 2 kΩ. With negligible output current, what is left-minus-right voltage?
  1. +2 V
  2. −4 V
  3. −2 V
  4. +4 V
Show answerHide answer
Answer: C
The left midpoint is 8(1)/(3+1)=2 V and the right midpoint is 8(2)/(2+2)=4 V. Subtracting left minus right gives −2 V. The positive 2 V value has the correct magnitude but reverses the requested output polarity.

Question 3 of 10

A powered-off 12 kΩ resistor remains connected across another 4 kΩ path. What resistance does an ideal ohmmeter across the resistor indicate?
  1. 16 kΩ
  2. 3 kΩ
  3. 8 kΩ
  4. 12 kΩ
Show answerHide answer
Answer: B
The meter sees both paths between its leads, so the indicated resistance is 12(4)/(12+4)=3 kΩ. The marked 12 kΩ value belongs to the resistor alone; switching off power does not remove the alternate conducting path across it.

Question 4 of 10

Two series resistors of 180 Ω and 420 Ω are connected across 12 V. How much power does the 420 Ω resistor absorb?
  1. 0.240 W
  2. 0.168 W
  3. 0.072 W
  4. 0.343 W
Show answerHide answer
Answer: B
The total resistance is 600 Ω, so the shared current is 12/600=0.020 A. The 420 Ω resistor absorbs i2R=0.0202(420)=0.168 W. The 0.240 W result is the power of the entire string, including the other resistor.

Question 5 of 10

A 24 Ω resistor is across an ideal 12 V source. Another 24 Ω branch is added across the same nodes. What are the original branch current and the new total current?
  1. 1.0 A and 1.0 A
  2. 0.25 A and 0.50 A
  3. 0.50 A and 1.0 A
  4. 0.50 A and 0.50 A
Show answerHide answer
Answer: C
The ideal source holds 12 V across both branches, so each carries 12/24=0.50 A and the total becomes 1.0 A. Halving the original current assumes a fixed total current; here the fixed quantity is voltage, and the source supplies the extra branch current.

Question 6 of 10

An unloaded 30 V divider must give 12 V across its 8 kΩ lower resistor. What upper resistance is needed?
  1. 12 kΩ
  2. 20 kΩ
  3. 5.33 kΩ
  4. 3.2 kΩ
Show answerHide answer
Answer: A
The lower resistor takes 12/30 of the total voltage, so the total resistance must be 8(30/12)=20 kΩ. Subtracting the lower 8 kΩ gives 12 kΩ above it. Using 20 kΩ as the upper resistor mistakes total resistance for the added resistance.

Question 7 of 10

A 20 V source feeds 4 Ω, then parallel branches of 12 Ω and a 3 Ω–9 Ω series pair. What is the drop across the 9 Ω resistor?
  1. 15 V
  2. 12 V
  3. 7.5 V
  4. 9.0 V
Show answerHide answer
Answer: D
The 3 Ω–9 Ω branch is 12 Ω, equal to the other branch, so the parallel equivalent is 6 Ω and total resistance is 10 Ω. The source current is 2 A, giving 12 V across the parallel group, and the target receives 12(9)/(3+9)=9 V. Reporting 12 V stops before the internal voltage division and assigns the whole branch voltage to one member.

Question 8 of 10

A proposed wye replacement has three resistor arms meeting at a center node. A fourth external wire also connects there. Why is ordinary three-terminal wye-to-delta replacement invalid?
  1. The arms have unequal resistance.
  2. The three outer nodes are distinct.
  3. The drawing has no triangular outline.
  4. The center is a fourth accessible terminal.
Show answerHide answer
Answer: D
A three-terminal wye replacement requires its center to join only the three arms. The external wire makes the center a fourth terminal whose behavior the delta would not preserve. Unequal arm resistances are allowed; they simply produce unequal delta edges.

Question 9 of 10

A wye has arms R₁ = 4 Ω, R₂ = 6 Ω, and R₃ = 12 Ω. What delta resistance belongs between terminals 1 and 2?
  1. 36 Ω
  2. 24 Ω
  3. 12 Ω
  4. 10 Ω
Show answerHide answer
Answer: C
The pairwise-product sum is 4(6)+6(12)+12(4)=144 Ω2, and edge 1–2 is opposite arm 3. Thus R12=144/12=12 Ω. Dividing by 6 Ω gives 24 Ω, which belongs to a different terminal pair.

Question 10 of 10

A 24 V bridge has edges a–c = 12 Ω, a–d = 30 Ω, c–d = 18 Ω, c–b = 8.4 Ω, and d–b = 3 Ω, with b at 0 V. What is the source current?
  1. 2.0 A
  2. 1.0 A
  3. 2.5 A
  4. 3.0 A
Show answerHide answer
Answer: A
The upper delta sum is 60 Ω, giving wye arms 12(30)/60=6 Ω at a, 3.6 Ω at c, and 9 Ω at d. With the unchanged lower resistors, both center-to-b paths are 12 Ω, giving Req=6+(12∥12)=12 Ω and source current 2 A. A 1 A answer is the current in one lower path after the total has split, not the current entering the bridge.
Set 2: Connections and first calculations10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A 150 Ω resistor and a 330 Ω resistor share a node with no other connection. What is their equivalent resistance?
  1. 180 Ω
  2. 103.125 Ω
  3. 480 Ω
  4. 495 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

What is the equivalent resistance of 15 Ω in parallel with 10 Ω?
  1. 6 Ω
  2. 25 Ω
  3. 5 Ω
  4. 12 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 28 V source feeds 2 Ω, then parallel branches of 12 Ω and a series path of 4 Ω followed by (6 Ω ∥ 3 Ω). What is the current in the original 3 Ω resistor?
  1. 28/9 A
  2. 28/27 A
  3. 14/9 A
  4. 56/27 A
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

An unloaded 18 V divider has 6 kΩ above 3 kΩ. What is the junction voltage relative to the lower return node?
  1. 12 V
  2. 6 V
  3. 9 V
  4. 3 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A 15 V divider has 5 kΩ above 10 kΩ. A 10 kΩ load is connected from its midpoint to return. What output voltage results?
  1. 10.0 V
  2. 5.0 V
  3. 7.5 V
  4. 12.0 V
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A total current of 15 mA enters 4 kΩ in parallel with 6 kΩ. What current flows in the 4 kΩ branch?
  1. 9 mA
  2. 6 mA
  3. 10 mA
  4. 5 mA
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A digital voltmeter has its red lead at 1.8 V and COM at 4.1 V relative to the same reference. What does it read?
  1. +2.3 V
  2. −5.9 V
  3. +5.9 V
  4. −2.3 V
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A movement has full-scale current 2 mA and full-scale voltage 80 mV. What shunt resistance gives a 20 mA range?
  1. 4.00 Ω
  2. 4.44 Ω
  3. 40.0 Ω
  4. 0.444 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A bridge has R₁ = 240 Ω above R₃ = 360 Ω on the left and R₂ = 800 Ω above Rₓ on the right. What Rₓ balances it?
  1. 1200 Ω
  2. 533.3 Ω
  3. 108 Ω
  4. 540 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A delta has R₁₂ = 12 Ω, R₂₃ = 18 Ω, and R₃₁ = 30 Ω. What wye arm connects terminal 2 to the center?
  1. 6.0 Ω
  2. 9.0 Ω
  3. 7.2 Ω
  4. 3.6 Ω
Show answerHide answer

Save this lesson to see this answer.

Set 3: Recover values and judge models10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

An isolated resistor triangle has edges a–b = 8 Ω, b–c = 10 Ω, and c–a = 14 Ω. What resistance is seen between a and b with c externally open?
  1. 24 Ω
  2. 32 Ω
  3. 8 Ω
  4. 6 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

An unloaded 10 V divider has two nominal 10 kΩ resistors, each ±10%. What are its minimum and maximum outputs across the lower resistor?
  1. 4.5 V and 5.5 V
  2. 4.0 V and 6.0 V
  3. 5.0 V and 5.0 V
  4. 4.09 V and 6.11 V
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A total of 21 mA enters parallel branches of 2 kΩ, 3 kΩ, and 6 kΩ. What current flows through 3 kΩ?
  1. 10.5 mA
  2. 7 mA
  3. 9 mA
  4. 3.5 mA
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A 32 V source feeds 2 kΩ, then parallel branches of 6 kΩ and two series resistors of 2 kΩ each. What current flows in either resistor of the two-resistor branch?
  1. 48/11 mA
  2. 8 mA
  3. 32/7 mA
  4. 16/11 mA
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A 200 µA movement has a coil resistance of 500 Ω. What multiplier resistance produces a 25 V full-scale range?
  1. 125.0 kΩ
  2. 125.5 kΩ
  3. 124.5 kΩ
  4. 50.0 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Two 40 kΩ resistors form a divider across 20 V. A voltmeter across the lower resistor reads 8 V. What is the voltmeter’s input resistance?
  1. 120 kΩ
  2. 40 kΩ
  3. 80 kΩ
  4. 160 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A balanced bridge has R₁ = 300 Ω above R₃ = 600 Ω and R₂ = 600 Ω above Rₓ = 1200 Ω. What input resistance is seen across the top and bottom nodes?
  1. 1800 Ω
  2. 600 Ω
  3. 900 Ω
  4. 300 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

An equal-arm sensor bridge has nominal arm resistance 2 kΩ and 6 V excitation. The lower-right sensor rises by 8 Ω. What is the approximate left-minus-right output?
  1. +6 mV
  2. +24 mV
  3. −24 mV
  4. −6 mV
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

Two equivalent delta and wye networks are connected to the same external circuit at their three labeled terminals. What must agree?
  1. Terminal voltages and terminal currents.
  2. The internal center-node potential.
  3. Every individual resistor current.
  4. The resistance of each internal arm.
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A 15 V bridge has a–c = 10 Ω, a–d = 25 Ω, c–d = 15 Ω, c–b = 7 Ω, and d–b = 2.5 Ω, with b at 0 V. What current flows from c to d?
  1. 0.450 A
  2. 0.225 A
  3. 0.750 A
  4. 0.375 A
Show answerHide answer

Save this lesson to see this answer.

Set 4: Choose and check a complete method10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

Two resistors are drawn end to end, but a third resistor also connects to their joining node. What prevents combining the first two by adding their resistances?
  1. Their voltage drops must be equal.
  2. Current can split at their junction.
  3. Their order changes total resistance.
  4. Each has a different reference node.
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 9 V source supplies a parallel network. Its total current is 0.75 A, and one branch is 18 Ω. What is the resistance of the only other branch?
  1. 12 Ω
  2. 24 Ω
  3. 54 Ω
  4. 36 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 45 V source feeds 3 Ω and then parallel branches of 18 Ω and a 6 Ω–12 Ω series pair. What total power is absorbed by the original 3 Ω and 12 Ω resistors together?
  1. 168.75 W
  2. 84.375 W
  3. 46.875 W
  4. 140.625 W
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

Resistors of 2 kΩ, 3 kΩ, and 5 kΩ run in that order from +25 V to return. What is the potential of the junction between 2 kΩ and 3 kΩ relative to return?
  1. 20 V
  2. 12.5 V
  3. 7.5 V
  4. 5 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A 12 V divider has 1 kΩ above 2 kΩ and a 2 kΩ load across the lower resistor. What power is absorbed in the upper resistor?
  1. 16 mW
  2. 64 mW
  3. 36 mW
  4. 48 mW
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

An ideal 4 V source, a 2 kΩ resistor, and a 2 MΩ voltmeter are mistakenly connected in one series loop. What does the voltmeter read, approximately?
  1. 0.004 V
  2. 2.000 V
  3. 3.996 V
  4. 0.000 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 50 µA, 100 mV movement is used for a 5 mA ammeter range. What are the required shunt resistance and the complete ammeter resistance?
  1. 20.20 Ω and 2020.20 Ω
  2. 20.00 Ω and 20.20 Ω
  3. 2000 Ω and 20.00 Ω
  4. 20.20 Ω and 20.00 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A bridge has R₁ = 200 Ω above R₃ = 500 Ω and R₂ = 600 Ω above Rₓ = 1500 Ω. Its source rises from 4 V to 8 V. What happens to the detector current at balance?
  1. It remains zero.
  2. It reverses sign.
  3. It equals 4/700 A.
  4. It doubles too.
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A delta and its equivalent wye are each measured between terminals 1 and 2 while terminal 3 is externally open. Why does the wye arm at terminal 3 carry zero current?
  1. All three outer terminals are shorted.
  2. Its resistance must be infinite.
  3. Its outer end has no closed path.
  4. Its center potential is always zero.
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A bridge has a–c = 8 Ω, a–d = 20 Ω, c–d = 12 Ω, c–b = 5.6 Ω, and d–b = 2 Ω. With 16 V from a to b, what current flows from a to c?
  1. 2.0 A
  2. 1.3 A
  3. 0.7 A
  4. 1.0 A
Show answerHide answer

Save this lesson to see this answer.

Set 5: Transfer and design checks10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

Parallel branches carry a fixed total of 24 mA. Their resistances are 3 kΩ and 9 kΩ; the 9 kΩ branch is then removed. What is the change in the 3 kΩ branch current?
  1. It rises by 18 mA.
  2. It stays unchanged.
  3. It falls by 6 mA.
  4. It rises by 6 mA.
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A 24 V source feeds 4 Ω, then parallel branches of 12 Ω and a 2 Ω resistor in series with an unknown R. The voltage across R is 8 V. What is R?
  1. 6 Ω
  2. 8 Ω
  3. 4 Ω
  4. 10 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 12 V divider has two 60 kΩ resistors. What minimum voltmeter input resistance keeps the reading across the lower resistor at least 5.7 V?
  1. 570 kΩ
  2. 1140 kΩ
  3. 600 kΩ
  4. 300 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

An equal-arm bridge has 4 V excitation and a lower-right sensor of R + ΔR. The sensor rises from R to 2R. What is the exact left-minus-right output?
  1. −1.000 V
  2. −0.667 V
  3. −0.500 V
  4. +0.667 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A wye has arms 3 Ω, 5 Ω, and 10 Ω at terminals 1, 2, and 3. What resistance does its equivalent delta present between terminals 1 and 2 with terminal 3 open?
  1. 9.5 Ω
  2. 8.0 Ω
  3. 19.0 Ω
  4. 15.0 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A 30 V bridge has a–c = 16 Ω, a–d = 40 Ω, c–d = 24 Ω, c–b = 11.2 Ω, and d–b = 4 Ω. What power does the original cross resistor absorb?
  1. 2.4 W
  2. 4.8 W
  3. 1.2 W
  4. 1.9 W
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 16 V divider has 2 kΩ above 6 kΩ. What load resistance across the lower resistor makes the output 8 V?
  1. 3 kΩ
  2. 2 kΩ
  3. 6 kΩ
  4. 4 kΩ
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 100 µA movement has a 1 kΩ coil and a multiplier for a 20 V range. The complete voltmeter is connected across the lower resistor of a 12 V divider with two 100 kΩ resistors. What are its coil current and percentage of full-scale deflection?
  1. 30 µA and 30%
  2. 60 µA and 60%
  3. 24 µA and 24%
  4. 48 µA and 48%
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A balanced delta has 45 Ω on each edge. What is the resistance of each arm in its equivalent balanced wye?
  1. 135 Ω
  2. 15 Ω
  3. 30 Ω
  4. 45 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A 36 V source feeds 3 Ω, then parallel branches of 9 Ω and a 3 Ω resistor followed by (6 Ω ∥ 12 Ω). What is the voltage across the original 12 Ω resistor?
  1. 16.00 V
  2. 14.40 V
  3. 9.60 V
  4. 11.68 V
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

64 Key Terms, each with its definition

A

Ammeter
An ammeter is an instrument inserted in a path to measure the current through it; its ideal series resistance is zero.
Open the selected branch before inserting an ammeter so the branch current passes through the meter.

B

Balanced delta or wye
A balanced delta or wye is a three-resistor network in which all three edge or arm resistances have the same value.
A balanced 60 Ω delta converts to a balanced 20 Ω wye, not to three 180 Ω arms.
Branch current
A branch current flows through one network path and is signed relative to a chosen arrow.
For equal branch voltages, the 2 kΩ path takes twice as much current as the 4 kΩ path.
Bridge balance
Bridge balance is the condition in which the midpoint potentials agree and the cross-connected detector carries zero current.
A balanced bridge can have unequal resistors, provided the upper-to-lower ratio is the same on each side.
Bridge cross branch
A bridge cross branch connects the two divider midpoints and can carry current when their potentials differ.
A finite cross resistor prevents separate unloaded-divider calculations in an unbalanced bridge.
Burden voltage
Burden voltage is the voltage drop introduced by a current meter as the measured current flows through its internal resistance.
A 2 Ω ammeter carrying 20 mA introduces a 40 mV drop that can alter the original path current.

C

Chained division
Chained division finds an internal voltage or current by applying valid divider ratios at successive levels of a network.
First find the voltage across a parallel group, then divide that voltage within one series branch.
COM lead
The COM lead is a meter’s common terminal, used as the reference for voltage polarity and the return terminal in current mode.
A negative voltage reading means the red voltage lead is below the potential of the COM lead.
Conductance
Conductance is the reciprocal of resistance and describes how much current flows per unit voltage across a resistor.
Adding another parallel branch increases total conductance, so the group’s equivalent resistance falls.
Conductance fraction
A conductance fraction is one branch’s conductance divided by the sum of all parallel branch conductances.
Multiplying total group current by a branch’s conductance fraction gives the current in that branch.
Current divider
A current divider is a parallel network that splits its incoming current among branches according to their conductances.
With a fixed total input, a 3 Ω branch receives more current than a 9 Ω branch at the same voltage.

D

d’Arsonval movement
A d’Arsonval movement is a moving coil in a permanent magnetic field whose pointer deflection is proportional to coil current.
External shunts and multipliers let one sensitive movement serve several current and voltage ranges.
Delta connection
A delta connection joins three resistor edges in a closed triangle, with each edge connecting a pair of outer terminals.
A pi drawing still forms a delta when its three resistors connect all three terminal pairs.
Delta-to-wye conversion
Delta-to-wye conversion replaces a resistor triangle with three center-connected arms while preserving the three-terminal behavior.
The arm at terminal 1 uses the product of the two delta edges touching terminal 1 over the delta sum.
Differential output
A differential output is a voltage formed by subtracting one node potential from another in a stated reference order.
If c is at 2.5 V and d is at 2.51 V, the bridge output from c to d is −10 mV.
Divider ratio
A divider ratio is a selected output voltage divided by the voltage applied to its series group.
A 2 kΩ lower resistor in a 10 kΩ total string receives one fifth of the applied source voltage.
Downstream loading
Downstream loading is the effect of all paths connected after a divider stage on the equivalent resistance seen by that stage.
A second divider connected to the first junction must be included when computing the first output.

E

Equivalent group
An equivalent group is a connected part of a network represented by one resistance for a particular reduction step.
The resistor feeding a parallel group is in series with the complete group’s equivalent resistance.
Equivalent resistance
An equivalent resistance replaces a resistor network at a chosen pair of terminals, preserving the relationship between terminal voltage and total entering current.
A series string totaling 2 kΩ draws the same terminal current as one 2 kΩ resistor at the same voltage.
Excitation voltage
Excitation voltage is the voltage applied across a bridge’s supply terminals to produce a signal.
Doubling excitation doubles the unbalanced output for fixed arm resistances and negligible output loading.

F

Full-scale current
Full-scale current is the coil current that moves a meter pointer to its maximum normal indication.
A 100 µA movement needs only 50 µA in its coil to reach half of a linear scale.
Full-scale voltage
Full-scale voltage is the voltage across a movement when it carries its full-scale coil current.
A movement with a full-scale voltage of 20 mV at 100 µA has a coil resistance of 200 Ω.

G

Galvanometer
A galvanometer is a sensitive current detector that can indicate a small current between the midpoints of a bridge.
A zero galvanometer current identifies balance when the bridge is energized and the detector is connected.

I

Incoming group current
The incoming group current is the total current entering the particular parallel combination being analyzed.
An inner parallel pair receives its feeding branch current, which can be smaller than source current.
Input resistance
Input resistance is the resistance presented by a measuring instrument between the terminals connected to the circuit.
A higher voltmeter input resistance draws less current and usually produces a smaller loading change.
Internal node
An internal node belongs inside a network and has no separate external connection.
The center created by delta-to-wye conversion is internal and has no matching node in the original delta.

L

Load
A load is a connected element or circuit that draws current from a source or output.
A load across the lower divider resistor forms an extra parallel path and lowers the output voltage.
Loading sag
Loading sag is the decrease in a divider’s output voltage when a connected load reduces its lower equivalent resistance.
A 10 kΩ load causes more sag than a 1 MΩ load on the same fixed-resistor voltage divider.

M

Meter loading
Meter loading is a circuit change caused by a connected instrument’s resistance, so its reading describes the connected circuit instead of the undisturbed one.
A perfectly calibrated 100 kΩ voltmeter can still pull a high-resistance divider output below its original value.
Multiplier resistor
A multiplier resistor is added in series with a movement so the selected range voltage drives exactly the full-scale coil current through the complete voltmeter.
Subtract coil resistance from the required total meter resistance to find the multiplier alone.

N

Node
A node is a set of points joined by ideal wire, all at the same electric potential.
Labeling both ends of each resistor by node name makes its connection clear even after redrawing.
Nominal value
A nominal value is the marked component value used as the starting point for design calculations.
Calculate the divider’s nominal output first, then use opposite tolerance extremes for its output limits.
Null measurement
A null measurement adjusts a comparison until a detector reads zero, then obtains the unknown value from the known settings.
The Wheatstone result at null depends on resistance ratios instead of the exact excitation voltage.

O

Ohmmeter
An ohmmeter is an instrument that applies its own test excitation and uses the response to determine resistance.
A powered-off resistor still reads low if another conducting path remains connected across it.
Ohms-per-volt sensitivity
Ohms-per-volt sensitivity is a moving-coil voltmeter’s input resistance per volt of selected range, equal to the reciprocal of its full-scale coil current in amperes.
A sensitivity of 20 kΩ/V gives a total input resistance of 200 kΩ on a 10 V range.
Open circuit
An open circuit is a broken conducting path with zero current but potentially nonzero voltage.
Opening a single-source series loop puts the source voltage across the gap while resistor drops vanish.
Open-terminal pair check
An open-terminal pair check compares equivalent resistance between two terminals while the third has no external connection.
Between terminals 1 and 2, a wye gives its first two arms in series because the third arm carries no current.
Original branch current
An original branch current belongs to an actual resistor in the starting circuit, before any equivalent replacement.
Compute the original delta-edge current from its restored endpoint voltage difference and original resistance.

P

Parallel connection
A parallel connection places elements across the same two nodes, giving them equal voltage.
Resistors at opposite sides of a drawing are parallel if their endpoint node labels match.
Power balance
Power balance is the equality between total power delivered and total power absorbed by all elements in a circuit.
A 30 V source delivering 2 A should supply the same 60 W that the solved resistor network absorbs.
Power rating
A power rating is the specified dissipation limit for a component under its stated operating conditions.
A resistor absorbing 0.30 W needs a suitable rating above that value for the operating conditions.
Preserved terminal voltage
A preserved terminal voltage is a voltage at an outer connection that agrees before and after an equivalent network replacement.
Once the two midpoint voltages are found in a transformed bridge, their difference applies to the cross resistor of the original bridge.

R

Reference polarity
A reference polarity assigns positive and negative endpoints to a voltage, defining the sign used to report that voltage.
For a divider output taken from a junction to its lower return node, marking that lower node positive reverses the usual positive sign.

S

Sensor bridge
A sensor bridge is a resistor bridge with one or more sensing arms whose resistance changes with a physical quantity.
A thermistor in one bridge arm changes the potential at that arm’s divider midpoint when its resistance changes.
Series connection
A series connection joins elements at a node with no other branch, forcing the same current through those elements.
Two resistors drawn end to end stop being a simple series pair when a load joins their midpoint.
Series–parallel reduction
Series–parallel reduction replaces genuine series and parallel resistor groups in successive stages, preserving terminal behavior while simplifying the circuit.
Combine an inner parallel pair first, then redraw to see which resistor is in series with its equivalent.
Short circuit
A short circuit is a zero-resistance connection that holds its endpoints at equal potential.
A short inserted in a series path adds no resistance; a short across a resistor bypasses that resistor.
Shunt resistor
A shunt resistor lies in parallel with a sensitive movement and carries the measured current beyond the coil’s share, extending the complete ammeter’s range.
For a 10 mA range with a 1 mA coil, the shunt carries 9 mA when the pointer reaches full scale.
Siemens
The siemens is the SI unit of conductance, equal to an ampere per volt or a reciprocal ohm.
A resistance of 4 Ω has a conductance of 0.25 S; the number 0.25 is not its resistance in ohms.
Signed percent error
Signed percent error is the measured value minus the undisturbed reference value, divided by that reference and multiplied by 100%.
A reading of 9 V for an undisturbed 10 V output has a signed error of −10%.
Small-change approximation
A small-change approximation replaces a nonlinear response by a nearby linear relation; its use requires the change to be small relative to the relevant reference value.
For an equal-arm bridge, a sensor change much smaller than its nominal resistance permits the linear estimate.
Strain gauge
A strain gauge is a sensor whose resistance changes when its supporting material deforms.
Placing a strain gauge in a bridge turns its small resistance change into a measurable midpoint difference.

T

Tap
A tap is a connection at a junction within a resistor string that provides a selected output voltage.
A tap above two lower series resistors includes both of their drops when measured from the return node.
Terminal current
A terminal current is the net current entering or leaving a network through one of its external connections.
Current entering a new wye arm can equal the sum of two original delta-edge currents at that terminal.
Terminal pair
A terminal pair is the two chosen points across which a network is connected or measured.
A triangle can give a different resistance when the measurement moves from one terminal pair to another.
Three-terminal equivalence
Three-terminal equivalence means two networks preserve the same terminal voltage–current relationships, including all pair resistances with the remaining terminal open.
A delta and its equivalent wye match each pair resistance when the remaining terminal is open.
Tolerance
A resistor’s tolerance is its allowed deviation from the marked resistance, usually given as a percentage that defines minimum and maximum permitted values.
A 1 kΩ resistor with ±5% tolerance can lie between 950 Ω and 1050 Ω before other effects are considered.

U

Undisturbed value
The undisturbed value is the circuit voltage or current before the measuring instrument is connected.
Find the original series current first, then include ammeter resistance to predict the connected reading.

V

Voltage divider
A voltage divider is a series resistor network that shares an applied voltage among its resistances, with an output taken between a chosen pair of points.
A junction output is found using the resistance from that junction to the chosen reference node.
Voltmeter
A voltmeter measures the potential difference between two nodes by connecting across them; an ideal one draws no current, while a real one adds a finite parallel resistance.
Connecting a voltmeter across a resistor leaves the original conducting path intact.

W

Wheatstone bridge
A Wheatstone bridge compares two resistor-divider midpoint potentials, allowing an unknown resistance to be obtained from the arm ratio when a detector reads zero.
Adjusting one known arm until the midpoint detector reads zero allows the unknown arm to be calculated.
Working backward
Working backward restores replaced groups to recover their original currents and voltages.
Restore a parallel pair only after finding the voltage across its equivalent in the reduced circuit.
Wye connection
A wye connection joins three outer terminals to one internal center through three separate resistor arms.
A tee drawing is a wye if its center connects only the three arms and has no external branch.
Wye-to-delta conversion
Wye-to-delta conversion replaces three center-connected arms with terminal-pair edges having the same external behavior.
For edge 1–2, divide the sum of pairwise wye products by the arm at the opposite terminal 3.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started