Capacitors and Inductors

Learn how capacitors and inductors store energy and how their voltage and current are linked through rates of change. Use derivatives and integrals to move between voltage and current, find stored energy, combine elements in series and parallel, and find DC steady-state values and the values just after a switch operates. Finish with mutual inductance: coupled coils, the dot convention, their stored energy and their series inductance.

BeginnerLesson 6 of 8 in Electric Circuits 1 Course

What you will learn

  1. Describe the ideal capacitor, move between its voltage and current with derivatives and integrals, and find the power it absorbs and the energy it stores.
    • Describe a capacitor and its charge–voltage relation
      Explain what a capacitor is, what capacitance measures, and how charge, voltage and the passive sign convention fit together.
    • Find capacitor current from its voltage
      Use i=C dv/dt to turn a capacitor voltage, given as a graph or a formula, into its current, and see why a capacitor is an open circuit at DC and why its voltage cannot jump.
    • Find capacitor voltage from its current
      Integrate the current to find the voltage, include the initial voltage, and use the area under a current graph as the change in charge and voltage.
    • Calculate power and stored energy in a capacitor
      Find the instantaneous power a capacitor absorbs and the energy stored in its electric field, and tell when it is storing energy and when it is giving it back.
  2. Describe the ideal inductor as the counterpart of the capacitor, move between its current and voltage, and find the energy stored in its magnetic field.
    • Describe an inductor and find its voltage from its current
      Explain what inductance measures and use v=L di/dt to find inductor voltage from a current graph or formula, including the behavior at DC and when a current is switched off.
    • Find inductor current from its voltage
      Integrate the inductor voltage to find its current, include the initial current, and read current changes from the area under a voltage graph.
    • Calculate power and stored energy in an inductor
      Find the power an inductor absorbs and the energy stored in its magnetic field, and compare how inductors and capacitors hold energy.
  3. Replace groups of capacitors or inductors with one equivalent element, carry initial voltages and currents into the equivalent, and divide voltage, charge or current among the elements.
    • Combine capacitors in series and parallel
      Find the equivalent capacitance of series, parallel and mixed groups, handle initial voltages, and find each capacitor's voltage and charge.
    • Combine inductors in series and parallel
      Find the equivalent inductance of series, parallel and mixed groups, handle initial currents, and find how voltage and current divide among the inductors.
  4. Use the DC behavior of capacitors and inductors and the continuity of capacitor voltage and inductor current to find voltages, currents and stored energy in circuits with resistors and sources.
    • Find DC steady-state values and stored energy
      Replace capacitors with open circuits and inductors with short circuits to find voltages, currents and stored energies once a DC circuit has settled.
    • Use continuity to find values just after a switch
      Carry capacitor voltages and inductor currents across a switching moment and find every other voltage, current and rate of change just after it.
  5. Explain how two coils share magnetic flux, write their voltage equations with the dot convention, and find the energy and the series inductance of coupled coils.
    • Explain mutual inductance and the coupling coefficient
      Describe how a changing current in one coil induces a voltage in a nearby coil, and relate the mutual inductance to the two self-inductances.
    • Write coupled-coil voltage equations with the dot convention
      Use the dots on coupled coils to choose the sign of each mutual-voltage term and write the terminal and loop equations of coupled coils.
    • Find the energy and series inductance of coupled coils
      Calculate the energy stored in two coupled coils and the equivalent inductance of coupled coils connected in series, aiding or opposing.

Capacitors and Inductors study guide

5 chapters

1

Charge, current, and energy in a capacitor

A capacitor stores separated charge, so its voltage records what current has delivered over time. Start with charge and capacitance, then use a voltage slope to find current and a current area to recover voltage. These two views explain both changing signals and steady DC behavior. Power connects the circuit variables to stored energy and shows why a capacitor can return energy even though it cannot create it.

1.1 Charge and capacitance

A capacitor has two conducting plates separated by an insulating dielectric. Applying a voltage places equal and opposite charges on the plates. Charge travels through the external wires onto one plate and away from the other; no charge crosses an ideal dielectric. The current entering one terminal equals the current leaving the other.

How much charge a capacitor holds

For an ideal, linear capacitor,

q=Cv.

Here q is the signed charge on the plate chosen as the positive voltage terminal. Capacitance measures charge per volt. Its unit is the farad: 1 F=1 C/V. The symbol C can therefore name either capacitance or the coulomb unit; its position in an equation tells you which.

A 4.7 μF capacitor at 12 V holds

q=(4.7×10−6)(12)=56.4×10−6 C=56.4 μC.

At 24 V its charge is 112.8 µC. The capacitance remains 4.7 µF. The applied voltage changes the stored charge, not the component's capacitance. At a fixed charge, the relationship runs the other way: v=q/C. A charge of 10 µC gives 5 V on 2 µF but only 2 V on 5 µF.

Common prefixes are micro (µ, 10−6), nano (n, 10−9), and pico (p, 10−12). Many circuit capacitors are in these ranges; supercapacitors can reach several farads.

What sets capacitance

For parallel plates,

C=εAd,ε=εrε0.

The plate area is A, the separation is d, and permittivity ε describes the dielectric's effect. With ε0≈8.854×10−12 F/m, air plates of area 0.01 m² and separation 0.1 mm give about 885 pF. Larger plates, a smaller gap, or a higher relative permittivity increase capacitance.

Choose references before calculating

Mark one terminal + and the other − for voltage. Under the passive sign convention, the current arrow enters the + terminal. Then the current law is i=C dv/dt and absorbed power is p=vi. A negative calculated current means actual flow is opposite the arrow.

If you reverse only the current arrow, the laws become i=−C dv/dt and p=−vi. The plate-charge relation q=Cv is unchanged because the voltage and charge references have not moved. Keeping references visible prevents a sign change in one equation from spreading into unrelated equations.

Ideal and real components

The ideal model has constant capacitance, no resistance, no leakage, and no voltage limit. A real capacitor has a voltage rating, some leakage through its dielectric, and series resistance. A polarized electrolytic capacitor must have its marked negative terminal at the lower potential; reverse voltage can damage it. These practical limits determine component selection even when an ideal model is used for the calculation.

Key Takeaways

  • Capacitance is charge per volt: q=Cv.
  • At fixed charge, a larger capacitance gives a smaller voltage.
  • Increasing plate area or permittivity raises capacitance; increasing separation lowers it.
  • The passive current reference enters the + voltage terminal.
  • Real capacitors have voltage ratings, leakage, and series resistance.

1.2 Voltage slopes determine capacitor current

A capacitor can have a large voltage and carry no current, or have zero voltage while carrying current. The deciding quantity is the voltage's rate of change. Differentiating q=Cv for constant capacitance gives

i=Cdvdt.

The passive sign convention is built into the plus sign. The slope has units V/s, so multiplying by F gives A.

Turn a straight-line voltage graph into current

Split the graph wherever its slope changes. On each straight segment, calculate Δv/Δt and multiply by capacitance. A rising segment gives positive current, a horizontal segment gives zero current, and a falling segment gives negative current.

Take a 2 µF capacitor. Its voltage rises from 0 to 10 V in 5 ms, stays at 10 V until 8 ms, and then falls to 0 V at 10 ms.

  1. During the rise, dv/dt=10/0.005=2000 V/s, so i=(2×10−6)(2000)=4 mA.
  2. During the hold, the slope is zero, so the current is zero.
  3. During the fall, dv/dt=(0−10)/0.002=−5000 V/s, so i=−10 mA.

The voltage is a continuous set of ramps and a plateau. The current is a set of constant steps. A corner in the voltage graph changes the current abruptly, but does not break the voltage graph.

Differentiate a voltage formula

For v(t)=10sin⁡(1000t) V and C=1 μF, with time in seconds,

dvdt=10(1000)cos⁡(1000t), i(t)=10cos⁡(1000t) mA.

The factor 1000 comes from the chain rule. Current is at its positive maximum when voltage crosses zero upward, and current is zero at a voltage peak. For a sinusoid, current leads voltage by a quarter period. This is a consequence of the derivative, without needing a new circuit model.

Constant voltage and continuity

A constant voltage has zero slope. An ideal capacitor at constant voltage therefore acts as an open circuit, even if that voltage is high. Open circuit describes its zero current; it does not say that its terminal voltage is zero.

Capacitor voltage cannot jump. A finite voltage change in zero time would require an unbounded current. A switching calculation therefore carries voltage continuously across the switching instant. Current can change immediately because it sets the new voltage slope.

Keep sign and units separate

The product Cv is charge, not current. Current requires C dv/dt. Convert milliseconds to seconds before calculating a slope: the rise above is 2000 V/s, not 2 V/s. Likewise, 2 µF is 2×10−6 F, so the result is 4 mA, not 4 A.

A negative current lowers the signed voltage. To decide whether energy is entering or leaving, also use the voltage sign: p=vi. When both voltage and current are negative, their product is positive, and the capacitor is gaining energy.

Key Takeaways

  • Capacitor current follows voltage slope: i=C dv/dt.
  • A flat voltage gives zero current, even at a nonzero voltage.
  • Capacitor voltage is continuous; capacitor current can jump.
  • Use vi, not current sign alone, to decide the direction of energy transfer.

1.3 Current areas determine capacitor voltage

A voltage slope tells you the capacitor current. Going the other way requires adding all the charge delivered over an interval. That makes voltage depend on both the current history and a known starting voltage.

Start from a known state

Integrating the capacitor law gives

v(t)=v(t0)+1C∫t0ti(τ) dτ.

The symbol τ is the integration variable. The integral is net delivered charge in coulombs. Dividing by capacitance gives the change in voltage; adding v(t0) gives the voltage itself. Equal capacitors receiving the same current keep any difference in their starting voltages.

For constant current over an interval,

v(t)=v(t0)+IC(t−t0).

A constant current gives a straight voltage ramp. Larger capacitance makes the ramp less steep for the same current.

Work through a piecewise current

A 1 µF capacitor starts at 5 V. It receives 2 mA from 0 to 3 ms, then −1 mA from 3 to 7 ms, and zero afterward.

During the first interval, delivered charge is

Δq=(2 mA)(3 ms)=6 μC.

Thus Δv=6 μC/1 μF=6 V. The voltage rises from 5 to 11 V. During the second interval,

Δq=(−1 mA)(4 ms)=−4 μC,

so voltage falls by 4 V, ending at 7 V. It stays at 7 V when current becomes zero. The second interval begins at 11 V, not at zero. Each endpoint supplies the next interval's initial value.

Read a current graph by area

A rectangular current pulse has area height times duration. A triangular pulse has half that area for the same height and base. Count area below the time axis as negative, then divide the signed total by capacitance. Equal positive and negative charge areas restore the starting voltage; they do not necessarily produce zero voltage.

The conversion 1 mA⋅1 ms=1 μC is useful for quick checks. If the graph has several pieces, add their charge areas before dividing, or carry voltage forward piece by piece.

Integrate a changing formula

Suppose i(t)=6e−2000t mA enters a 1 µF capacitor that starts at zero voltage. Then

v(t)=110−6∫0t6×10−3e−2000τ dτ =3(1−e−2000t) V.

The antiderivative contributes a factor −1/2000; evaluating the lower limit provides the constant term. At time zero the expression is zero, and as current dies away the voltage approaches 3 V.

A zero current preserves the voltage already reached. This charge memory is useful in timers and ramp generators. A real constant-current charging circuit stops or resets before the capacitor's voltage rating is reached; the ideal ramp itself has no upper limit.

Key Takeaways

  • Voltage equals its initial value plus net charge divided by capacitance.
  • Use signed current area: Δv=(1/C)∫i dt.
  • Carry each interval’s endpoint into the next interval.
  • Zero current holds the existing voltage.
  • A constant current produces a linear voltage ramp.

1.4 Power and electric-field energy

A capacitor stores energy in its electric field. Instantaneous power tells you how quickly that energy is changing; stored energy tells you how much is present now. Their units are different: power is measured in watts and energy in joules.

From power to energy

With the passive sign convention,

p=vi=Cvdvdt.

Positive power means the capacitor absorbs energy. Negative power means it returns energy to the circuit. Integrating from the uncharged state gives

w=∫0vCv~ dv~=12Cv2.

Using q=Cv also gives w=qv/2=q2/(2C). The factor one-half comes from integrating a quantity proportional to voltage. Stored energy is nonnegative and depends on the square of voltage: +10 V and −10 V store equal energy.

Check energy against a power graph

A 2 µF capacitor rises from 0 to 10 V in 5 ms while receiving 4 mA. Halfway through, voltage is 5 V, so

p=(5)(0.004)=20 mW.

Just before the ramp ends, power has risen to 40 mW. The area under this triangular power graph is

12(5 ms)(40 mW)=100 μJ.

The energy formula agrees:

w=12(2×10−6)(10)2=100 μJ.

When voltage stops rising, current and power become zero. The stored energy stays at 100 µJ. If voltage later falls from +10 V to zero, power is negative during that fall and the capacitor returns the 100 µJ.

Use the signs of both variables

Positive current does not always mean energy storage. If voltage is negative and current is positive, the signed voltage moves toward zero and vi<0: stored energy falls. Conversely, negative voltage with negative current gives positive power and growing voltage magnitude. The energy formula and the power product must tell the same story.

An ideal capacitor dissipates no energy. Over an interval that begins and ends at the same voltage, its net absorbed energy is zero. Resistances in a real circuit account for heating during charge and discharge.

Compare voltage and capacitance

Doubling capacitance at fixed voltage doubles energy. Doubling voltage at fixed capacitance multiplies energy by four. For example, a 470 µF capacitor at 400 V stores

w=12(470×10−6)(400)2=37.6 J.

A 1 F capacitor at 2.7 V stores 3.645 J. A large farad rating alone does not tell you which device holds more energy. A charged capacitor can remain hazardous after power is disconnected; discharge it through a suitable resistor before handling it.

Even at steady DC, energy can remain substantial: 100 µF at 12 V stores 7.2 mJ while absorbing zero power. Zero power means unchanged energy. In calculations, convert capacitance to farads, square the voltage, and retain the one-half factor.

Key Takeaways

  • Absorbed power is p=vi; its sign sets the direction of energy transfer.
  • Stored energy is w=12Cv2 and is never negative.
  • Doubling voltage multiplies energy by four.
  • Zero power can coexist with nonzero stored energy.
  • An ideal capacitor returns energy without dissipating it.
2

Current, voltage, and energy in an inductor

An inductor stores energy in a magnetic field created by current. Its voltage responds to changes in that current, so the same calculus used for a capacitor now works with voltage and current exchanged. Follow current slopes to find voltage, then voltage areas to recover current. The power and energy relations explain why a steady current can hold energy and why interrupting a coil's current creates a large voltage.

2.1 Current slopes determine inductor voltage

An inductor is a coil of wire, often wound around a magnetic core. Current produces magnetic flux through the turns. Flux linkage, denoted by λ, combines the flux linked by those turns. In the linear model,

λ=Li.

Inductance L measures flux linkage per ampere. Its unit is the henry: 1 H=1 V⋅s/A. Common prefixes are mH and µH.

A changing current produces voltage

The terminal voltage is the rate of change of flux linkage. For constant inductance and a current reference entering the + voltage terminal,

v=Ldidt.

The product Li is flux linkage, not voltage. Voltage follows the slope of current. A large constant current produces zero ideal-inductor voltage; a small current changing rapidly can produce a large voltage.

For a 50 mH inductor, let current rise from 0 to 2 A in 10 ms, remain at 2 A until 30 ms, then fall to zero at 31 ms.

  1. The rising slope is 2/0.010=200 A/s, giving v=0.05(200)=10 V.
  2. During the hold, current slope and voltage are zero.
  3. The falling slope is −2/0.001=−2000 A/s, giving v=−100 V.

The shorter fall produces a larger voltage magnitude. The negative sign refers to the marked voltage polarity.

For a formula such as i(t)=0.2sin⁡(500t) A in a 0.1 H inductor,

v(t)=0.1(0.2)(500)cos⁡(500t)=10cos⁡(500t) V.

For a sinusoid, voltage leads current by a quarter period. The derivative supplies both the cosine and the factor 500.

Steady current and sudden interruptions

At constant current, di/dt=0, so an ideal inductor acts as a short circuit. It can carry a nonzero current at zero voltage. Inductor current cannot jump: a finite change in zero time would require an unbounded voltage.

Even a very short finite interruption can demand a high voltage. Reducing 1 A to zero in 1 µs through 10 mH requires an average voltage magnitude of

∣v∣=0.01110−6=10,000 V.

This explains sparks at contacts that interrupt coil current. A flyback diode gives the current in a DC relay coil a path after the drive is removed, limiting the voltage spike.

What sets inductance

For a fixed coil shape and core, inductance grows roughly with the square of the turn count. Doubling the turns gives about four times the inductance. A larger cross-section or a core of greater permeability also raises inductance.

Real coils have winding resistance and capacitance between turns. Winding resistance creates a DC voltage drop. At high current an iron core can saturate, reducing inductance, so the constant-inductance model stops describing that region accurately.

Key Takeaways

  • Flux linkage follows λ=Li; voltage follows v=L di/dt.
  • A faster current change gives a larger voltage magnitude.
  • An ideal inductor at constant current acts as a short circuit.
  • Inductor current is continuous; voltage can jump.
  • A flyback diode provides a path for coil current after switching.
  • Real coils have winding resistance and can saturate.

2.2 Voltage areas determine inductor current

Voltage across an inductor changes its current. To find the current after an interval, add the voltage's accumulated effect to the current that was already flowing. A zero voltage stops the current from changing; it does not erase it.

Integrate from a known current

From v=L di/dt,

i(t)=i(t0)+1L∫t0tv(τ) dτ.

The integral is a signed volt-second area. Divide it by inductance to obtain the change in current, then add the initial current. The units check is V⋅s/H=A.

For constant voltage,

i(t)=i(t0)+VL(t−t0).

Thus 12 V across 0.3 H raises current at 40 A/s. The ideal relation produces a continuing ramp. In a real source-and-coil circuit, winding resistance develops an increasing voltage drop and eventually limits current.

Carry a negative initial current forward

A 20 mH inductor starts at −1 A and has 4 V across it for 10 ms. Afterward the voltage is zero. The voltage area during the pulse is

∫v dt=(4)(0.010)=0.04 V⋅s.

The current change is 0.04/0.02=2 A. Adding the initial value gives i(10 ms)=−1+2=1 A. The slope is 200 A/s, so the current crosses zero at 5 ms. It then continues upward until the pulse ends and holds at +1 A afterward.

The positive voltage raises the signed current throughout the pulse. At first it reduces the magnitude of a negative current; later it increases a positive current. Power changes sign when current crosses zero, even though voltage remains positive.

Integrate a decaying voltage

Let v(t)=10e−50t V across 0.1 H, with zero initial current. For time in seconds,

i(t)=10.1∫0t10e−50τ dτ =2(1−e−50t) A.

The lower integration limit makes the current zero at time zero. As voltage tends to zero, current approaches 2 A. A decaying applied voltage can leave a lasting current in an ideal closed path.

Use area without a formula

For a voltage graph, add rectangle and triangle areas with their signs. Divide the net area by inductance. If successive pulses have equal and opposite areas, the final current equals the starting current. It is zero only if the starting current was zero.

Keep the current reference fixed across intervals. A negative result means current flows opposite that reference, and becomes the next interval's signed initial current.

Match the capacitor pattern
CapacitorInductor
Current sets voltage slopeVoltage sets current slope
Current area changes voltageVoltage area changes current
Voltage is continuousCurrent is continuous
Open circuit at constant voltageShort circuit at constant current

This exchange of voltage and current is duality.

Key Takeaways

  • Current equals its initial value plus voltage area divided by inductance.
  • Positive voltage area raises signed current; negative area lowers it.
  • Zero voltage preserves the current already flowing.
  • The capacitor and inductor laws exchange the roles of voltage and current.

2.3 Power and magnetic-field energy

An inductor's magnetic field holds energy whenever current flows. The energy depends on current, while the rate of energy transfer depends on both current and voltage. A steady current can therefore store energy without requiring ongoing power absorption by an ideal inductor.

Derive the energy relation

Using the passive sign convention,

p=vi=Lididt.

Integrate from zero current to the present current:

w=∫0iLi~ di~=12Li2.

Energy is measured in joules. The square makes it nonnegative for either current direction. A 0.5 H inductor at 3 A holds

w=12(0.5)(3)2=2.25 J.

At −3 A it holds the same energy. Doubling current multiplies energy by four; doubling inductance at fixed current doubles energy.

Follow power during a ramp

A 50 mH inductor rises from zero to 2 A in 10 ms. Its voltage during the rise is 10 V. Halfway through, current is 1 A and absorbed power is 10 W. Just before the ramp ends, current is 2 A and power is 20 W.

The energy absorbed during the ramp is the area of the power triangle:

Δw=12(0.010)(20)=0.1 J.

The stored-energy formula gives the same result: w=12(0.05)(2)2=0.1 J. During a subsequent constant-current interval, voltage and power are zero and the energy stays at 0.1 J.

If the current then falls to zero in 1 ms, voltage is −100 V. Just after the fall starts, power is −200 W. Its magnitude decreases as current decreases, and its triangular area is −0.1 J. The inductor returns all the stored energy.

Distinguish release from dissipation

Negative absorbed power means the inductor is supplying energy to the rest of the circuit. It does not mean stored energy has become negative. An ideal inductor dissipates no energy; if an interval starts and ends at the same current, its net absorbed energy is zero.

For a real coil, winding resistance can turn the released energy into heat. When the current path is interrupted, the field's energy may feed a spark. A flyback path lets current continue while its energy is dissipated in the coil resistance and protective components.

Compare the two storage elements
QuantityCapacitorInductor
Stored energy12Cv212Li2
Field holding energyElectricMagnetic
Nonzero state at zero absorbed powerConstant voltageConstant current
Way an ideal element retains energyIsolated charged platesA closed current path

A disconnected ideal capacitor can keep its charge and voltage. An ideal inductor needs a closed path to keep its current. In either energy formula, convert the component value to base units before squaring the state variable: 50 mH is 0.05 H, not 50 H.

Key Takeaways

  • Inductor energy is w=12Li2 in its magnetic field.
  • Positive vi means energy absorption; negative vi means energy release.
  • Energy depends on current magnitude, not its direction.
  • A steady current can store energy at zero inductor voltage.
  • An ideal inductor needs a closed current path to retain magnetic energy.
3

Replace series and parallel groups

Series and parallel connections let you replace several storage elements with one element at the same two terminals. Identify the nodes first, then use the shared current or voltage to derive the equivalent value and divide quantities among the components. Initial voltages and currents must also match the connection. A terminal equivalent can hide energy inside a group, so keep the individual states when internal energy matters.

3.1 Equivalent capacitance and voltage division

A circuit's connections determine its equivalent capacitance. Elements are in parallel when they share the same two nodes. They are in series when their shared node has no other branch, so the same current must pass through both. Their positions on the page do not establish the connection.

Add capacitances in parallel

Parallel capacitors have the same voltage and their charges add:

qtotal=(C1+C2+⋯ )v.

Thus Ceq=C1+C2+⋯. For 6 µF and 3 µF in parallel, the equivalent is 9 µF. At any common voltage, the 6 µF device holds twice the charge of the 3 µF device. Their currents also divide in proportion to capacitance:

ik=CkCeqi.
Combine reciprocals in series

Series capacitor voltages add, and their common current produces voltage slopes that add. This gives

1Ceq=1C1+1C2+⋯ .

For two devices, Ceq=C1C2/(C1+C2). A 6 µF and a 3 µF capacitor give 2 µF in series, smaller than either component. These are the opposite of the resistor combination rules.

If series capacitors start uncharged, they receive equal charge. Across 12 V, this pair has q=(2 μF)(12 V)=24 μC on each capacitor. Their voltages are 4 V on 6 µF and 8 V on 3 µF. The smaller capacitance takes the larger voltage because v=q/C. For two initially uncharged capacitors,

v1=C2C1+C2v.

Individual voltage ratings must accommodate these unequal voltages.

Reduce a mixed network from the inside out

Place 4 µF in series with a parallel pair of 2 µF and 10 µF. All start uncharged, and the network is brought to 30 V.

  1. The parallel pair is 2+10=12 μF.
  2. Its series combination with 4 µF is 4(12)/(4+12)=3 μF.
  3. The series charge is 3(30)=90 μC.
  4. The 4 µF device has 90/4=22.5 V, leaving 7.5 V across the pair.
  5. The pair's charges are 2(7.5)=15 μC and 10(7.5)=75 μC. They sum to 90 µC.

Reduce to find terminal behavior, then work backward to find each component's state.

Carry initial voltages and internal energy

For series capacitors, add initial voltages with their marked polarities to obtain the equivalent's initial voltage. Series capacitors with existing charge need not have equal plate-charge magnitudes. In parallel, the initial voltages must already agree because both devices share two nodes.

A terminal equivalent need not preserve total internal energy. Two 2 µF capacitors in series at signed voltages +5 V and −5 V have zero terminal voltage. Their 1 µF equivalent therefore shows zero energy, but each physical capacitor holds 25 µJ, for 50 µJ total. The opposing initial voltages keep this energy hidden from the two terminals. Calculate internal energy from the individual capacitor voltages when those states matter.

Key Takeaways

  • Parallel capacitances add; series capacitances combine by reciprocals.
  • Initially uncharged series capacitors receive equal charge, so smaller capacitance takes more voltage.
  • Parallel capacitor current divides in proportion to capacitance.
  • Equivalent initial series voltage is the signed sum of individual voltages.
  • A terminal equivalent can hide internal stored energy.
  • Reduce mixed networks first, then work backward to individual values.

3.2 Equivalent inductance and current division

For coils with no magnetic coupling, inductance combines like resistance: add values in series and use reciprocals in parallel. The connection also determines which initial currents can exist and how later current changes divide.

Series coils share one current

In series, the common current has the same slope through every coil. Their voltages add:

v=(L1+L2+⋯ )didt,Leq=L1+L2+⋯ .

The voltage across an individual coil is vk=(Lk/Leq)v. The larger inductance takes the larger share of voltage. Series inductors carry the same initial current; that common value is the equivalent's initial current. Do not add the currents of components in one unbranched path.

Parallel coils share one voltage

In parallel, current slopes add at the terminals:

1Leq=1L1+1L2+⋯ .

For two, Leq=L1L2/(L1+L2). Thus 60 mH in parallel with 30 mH gives 20 mH. The equivalent's initial current is the signed sum of the branch initial currents, which may differ.

Because dik/dt=v/Lk, a smaller inductance has a larger current slope at the same voltage. For two coils,

Δi1=L2L1+L2Δi.

This divides changes in current. It divides the total currents themselves when both start at zero. For nonzero initial currents, add each branch's own initial value after finding its change.

Work forward and back through a mixed group

A 10 mH coil is in series with 60 mH and 30 mH in parallel. All start at zero current. A constant 6 V is applied to the network.

The parallel pair is 20 mH, so the total is 30 mH. The total current slope is 6/0.03=200 A/s. The series 10 mH coil has 0.01(200)=2 V, leaving 4 V across the parallel pair.

After 15 ms, total current is 200(0.015)=3 A. The parallel currents are 4(0.015)/0.06=1 A and 4(0.015)/0.03=2 A. They add to the 3 A terminal current, as KCL requires.

Terminal current can hide circulating current

Suppose parallel 60 mH and 30 mH coils carry +2 A and −1 A in the same reference direction. Terminal current is +1 A, so the 20 mH equivalent holds 10 mJ. The physical coils hold

12(0.06)(2)2+12(0.03)(−1)2=135 mJ.

The remaining 125 mJ belongs to a circulating current of 5/3 A around the internal loop. Its two branch contributions cancel at the terminals.

Check for shared flux

The formulas above apply to uncoupled inductors. Magnetically coupled coils induce additional voltages in one another. Their series equivalent includes two mutual terms:

Leq=L1+L2±2M.

The dots and current direction decide the sign. Ignoring visible coupling can therefore give the wrong equivalent even when the series connection is recognized correctly.

Key Takeaways

  • Uncoupled series inductances add; parallel inductances combine by reciprocals.
  • Series coils share initial current; parallel initial currents add with signs.
  • Parallel division applies to current changes when initial currents differ.
  • An internal circulating current can store energy hidden from a terminal equivalent.
  • Magnetic coupling adds mutual terms to the coil equations.
4

Find DC states and switching values

A settled DC circuit and a circuit just after switching require different drawings. First find the energy already stored from the circuit before the switch operates. Then carry capacitor voltage and inductor current into the new connection and use Kirchhoff's laws to find the remaining values. This separates the state the circuit retains from the current and voltage changes caused immediately by a switch.

4.1 DC steady state and stored energy

In DC steady state, every voltage and current has stopped changing. The two storage-element laws then simplify: capacitor current is zero and ideal-inductor voltage is zero. This allows a resistive circuit calculation to reveal the stored state.

Redraw before solving

Replace each capacitor with an open branch and each ideal inductor with a wire. Keep the capacitor's two terminal nodes marked and track the wire replacing the inductor. Solve the resistive network with Ohm's law, KCL, KVL, and division rules. Then read capacitor voltage across its open terminals and inductor current through its replacement wire.

An open branch can have nonzero voltage. A wire can carry nonzero current. Once these values are known, calculate energy from wC=12CvC2 and wL=12LiL2.

A circuit containing both elements

A 12 V source feeds a 2 Ω resistor and a 50 mH inductor in series to node b. From node b to the return are a 4 Ω resistor and a parallel 100 µF capacitor. In steady state, the inductor becomes a wire and the capacitor branch becomes open. The remaining resistors are in series:

iL=122+4=2 A.

Node b is at 2(4)=8 V, which is also the capacitor voltage. The energies are

wL=12(0.05)(2)2=0.1 J, wC=12(100×10−6)(8)2=3.2 mJ.

Neither storage element absorbs power at this steady state, although both hold energy.

A resistor beside an open branch

A 10 mA source supplies two parallel branches. One is 1 kΩ alone; the other is 2 kΩ in series with 1 µF. At DC steady state, the capacitor branch carries zero current. All source current flows through 1 kΩ, setting a common branch voltage of 10 V.

The 2 kΩ resistor has zero current and hence zero voltage drop. The capacitor therefore has the full 10 V, storing 12(10−6)(10)2=50 μJ. A voltage divider would be wrong here: the two resistors are not a conducting series pair.

Let the whole connection determine the state

An ideal inductor directly across a capacitor makes their steady-state voltage zero. The capacitor then stores no energy. A capacitor in series with an inductor blocks steady current, so that inductor has zero steady-state energy. These outcomes follow from the connections, not from a rule that all storage elements lose energy at DC.

The replacements are guaranteed for DC steady state. Just after switching, capacitor current and inductor voltage must instead be found from the circuit. Either can happen to be zero at a particular instant, but that is a result of the circuit equations.

Relate the model to components

A coupling capacitor in a signal path blocks steady current while allowing current when its voltage changes. A choke is an inductor placed in a supply path: it carries steady current with only the voltage drop caused by real winding resistance. If a winding resistance is drawn, retain it when replacing the ideal inductive part by a wire.

Key Takeaways

  • At DC steady state, replace capacitors by opens and ideal inductors by shorts.
  • Find capacitor voltage and inductor current from the resulting resistive network.
  • A resistor in a blocked branch has zero current and zero voltage drop.
  • Stored energy can remain nonzero at steady state.

4.2 Keep the state across a switching instant

A switch can change circuit connections immediately. It cannot make a capacitor voltage or an inductor current jump. Write 0− for just before switching and 0+ for just after it:

vC(0+)=vC(0−),iL(0+)=iL(0−).

The voltage and current references must stay consistent on both sides of the instant. These retained values are the initial conditions.

Build the new instant's circuit

First solve the pre-switch circuit for its capacitor voltages and inductor currents. If it has settled under DC sources, use the steady-state replacements. Next draw the actual post-switch connections. At the initial instant, represent each capacitor by a voltage source equal to its retained voltage and each inductor by a current source equal to its retained current.

Solve this circuit for the remaining values. Then recover the initial slopes:

dvCdt(0+)=iC(0+)C,diLdt(0+)=vL(0+)L.

The source replacements describe this instant; they do not make the capacitor voltage or inductor current constant afterward.

Add a load to a charged node

A 12 V source, 2 Ω series resistor, 50 mH inductor, and node-b parallel combination of 4 Ω and 100 µF have settled to iL=2 A and vC=8 V. A switch adds 3 Ω from node b to the return.

Immediately afterward, capacitor voltage is still 8 V and inductor current still 2 A. The resistor currents are 8/4=2 A and 8/3≈2.67 A. Taking capacitor current downward into its positive terminal, KCL gives

iC=2−2−83=−83 A.

The capacitor supplies the extra load current, so its initial voltage slope is about −26,700 V/s. Its voltage is continuous although its current jumped from zero. KVL gives vL=12−2(2)−8=0 V at this same instant. The inductor's initial current slope is therefore zero.

Give an inductor a new discharge path

A 10 V source has driven a 0.2 H inductor and 2 Ω resistor in series to steady state. Current is 5 A. The switch removes the source and closes a loop through the inductor, its 2 Ω resistor, and an 18 Ω resistor.

The initial current remains 5 A. The 18 Ω resistor has a 90 V drop in its current direction, and the inductor's passive voltage is

vL=−(2+18)(5)=−100 V.

Its initial current slope is −100/0.2=−500 A/s. The voltage magnitude can exceed the old supply voltage because the inductor is now returning stored energy.

Recognize incompatible ideal connections

Connecting a charged ideal capacitor directly across a different ideal voltage source demands a voltage jump. Opening the only path of a nonzero ideal-inductor current demands a current jump. Such connections have no finite current or voltage solution in the simple ideal model. In real circuits, parasitic elements, surges, clamps, or arcing determine what happens. A new DC final value must never replace the retained state at the switching instant.

Key Takeaways

  • Continuity preserves capacitor voltage and inductor current through switching.
  • Use the new connections with retained voltage and current sources at 0+.
  • KCL finds capacitor current; KVL finds inductor voltage.
  • Initial slopes follow from iC/C and vL/L.
  • Initial values and final steady-state values answer different questions.
  • An incompatible ideal connection cannot be resolved by forcing a state jump.
5

Use mutual inductance and the dots

Two coils can influence one another through shared magnetic flux even without a wire between them. Mutual inductance measures that link; the dots tell you how to assign its voltage polarity. Use the link to write terminal and loop equations, then account for the shared field in stored energy and series equivalents. Reference directions matter throughout: mark the currents and voltage polarities before choosing any signs.

5.1 Shared flux and coupling strength

Current in a coil creates magnetic flux. Some of that flux can also pass through another coil. A changing current in the first coil then induces voltage in the second, even if the second coil is open and carries no current.

Self-inductance and mutual inductance

Self-inductance relates a coil's flux linkage to its own current. Mutual inductance, M, relates flux linkage in one coil to current in the other. In a linear reciprocal pair, the mutual inductance is the same in both directions: M12=M21=M. Like self-inductance, it is measured in henries.

With coil 2 open, the induced voltage magnitude is

∣v2∣=M∣di1dt∣.

The current in coil 1 must change. A constant current can create flux without inducing voltage in coil 2. Likewise, an open secondary coil can have voltage without current; an open circuit does not require zero voltage.

Express coupling relative to both coils

The coupling coefficient is

k=ML1L2,M=kL1L2,0≤k≤1.

At zero coupling, no flux is shared. At perfect coupling, all flux of each coil links the other; this is an ideal limit. The bound means M≤L1L2. Mutual inductance is nonnegative in this notation; its contribution's sign comes from the terminal references and dots.

The square root is important. It gives a geometric mean with units H. Using kL1L2 would have units H² and cannot be an inductance. An arithmetic mean also gives the wrong relation when the coils have different self-inductances.

Calculate coupling and induced voltage

Take L1=8 mH, L2=2 mH, and k=0.75. First calculate the geometric mean:

L1L2=8(2)=4 mH.

Both input values use mH, so the result also uses mH. Then M=0.75(4)=3 mH. If current 1 rises at 500 A/s while coil 2 is open,

∣v2∣=(0.003)(500)=1.5 V.

Coil 1's own voltage is 0.008(500)=4 V. The two voltages use different inductances: self-inductance for its own changing current, mutual inductance for the current in the other coil.

What changes coupling

Turn counts, spacing, orientation, and core material determine the shared flux. Moving coils apart or turning their axes at right angles reduces mutual inductance in the usual aligned-coil arrangement. A shared iron core can provide coupling above 0.99; separated air-core coils generally couple less strongly.

Inductive chargers use the shared flux deliberately. Current sensors can detect a changing current without a conductive connection to it. The same effect can be unwanted: coupling between nearby conductors creates crosstalk, a signal induced in one circuit by changing current in another.

Key Takeaways

  • Mutual inductance links one coil’s voltage to the other coil’s changing current.
  • M=kL1L2, with 0≤k≤1.
  • An open coil can have induced voltage; constant driving current induces none.
  • Geometry, spacing, orientation, and core material determine coupling.

5.2 Choose mutual-voltage signs with the dots

Dots mark the relative winding sense of coupled coils. They do not identify a terminal that is always positive. They tell you the polarity induced by a current change in the other coil, relative to the current and voltage references you choose.

Read one induced voltage at a time

A reference current entering a dotted terminal produces a mutual-voltage reference positive at the other coil's dotted terminal. If the current reference enters an undotted terminal, the induced + reference is at the other coil's undotted terminal. The signed derivative then tells you whether the instantaneous voltage follows or opposes that reference polarity.

For each receiving coil, write a self term from its own current and a mutual term from the other current. The self term is positive when its own current reference enters its + voltage terminal. Choose the mutual sign by comparing the dot-rule polarity with the receiving coil's marked voltage polarity.

Both currents enter dots

With both currents entering their dots and both voltage references positive at their dots,

v1=L1di1dt+Mdi2dt, v2=Mdi1dt+L2di2dt.

For L1=8 mH, L2=2 mH, M=3 mH, and slopes of 200 and 100 A/s,

v1=0.008(200)+0.003(100)=1.9 V, v2=0.003(200)+0.002(100)=0.8 V.

The coefficients of each coil's own derivative are its self-inductances. Both mutual coefficients are the same M.

One current enters an undotted terminal

Now reverse coil 2 relative to its current path and keep each voltage reference passive. Current 1 enters a dot; current 2 enters an undotted terminal. Both mutual terms become negative:

v1=L1di1dt−Mdi2dt,v2=L2di2dt−Mdi1dt.

With the same numerical slopes, v1=1.6−0.3=1.3 V and v2=0.2−0.6=−0.4 V. A negative total voltage means the actual polarity is opposite the chosen reference. It is not a reason to change M to a negative parameter.

Put the full coil voltage into KVL

A loop has a source, resistor, and coil 1. With loop current 1 and the other coil's current 2 both entering dots, KVL is

vs=Ri1+L1di1dt+Mdi2dt.

If current 2 is changing, leaving out its mutual term drops part of coil 1's voltage. If a coil carries a difference of mesh currents, use that branch-current difference in its self term and in the mutual voltage it induces in the other coil. The magnetic effect follows actual coil current.

Changing a current arrow is a reference change, so change the corresponding signed variable consistently. Physically reversing a coil connection changes the winding relationship. In either case, start from the marked dots, arrows, and receiving voltage polarity; the drawing's left-to-right layout gives no sign rule.

Key Takeaways

  • Dots specify relative induced polarity, not permanent positive terminals.
  • Each coil voltage has a self term and a mutual term.
  • Use the other coil’s current derivative in the mutual term.
  • With passive references, matching dot-entry senses give positive mutual coefficients.
  • KVL must include the coil’s full self-plus-mutual voltage.

5.3 Coupled-coil energy and series equivalents

Two coupled coils store energy in a shared magnetic field. Adding the separate self-energy terms misses the interaction between them. The same interaction also changes their series equivalent inductance.

Include mutual energy

For signed currents with the chosen reference directions,

w=12L1i12+12L2i22±Mi1i2.

Use a positive mutual coefficient when both current references enter dots or both leave dots. Use a negative coefficient when one enters a dot and the other leaves a dot. Then substitute the signed currents; do not choose the sign again from their numerical values.

For L1=8 mH, L2=2 mH, M=3 mH, i1=2 A, and i2=1 A, the self energies are 16 mJ and 1 mJ. The mutual product is 6 mJ. Matching dot-entry senses give w=16+1+6=23 mJ; opposite senses give w=16+1−6=11 mJ.

Total stored energy cannot be negative. Requiring this for every current pair gives M2≤L1L2, the same bound expressed by k≤1. A computed negative total calls for checking the mutual parameter, current references, and arithmetic.

Count two mutual terms in series

In series aiding, the common current enters the dotted terminal of each coil in turn. Each coil's voltage contains its self term plus one mutual term:

v=(L1+M)didt+(L2+M)didt.

Therefore,

Laiding=L1+L2+2M.

In series opposing, the current enters the dot of one coil and the undotted terminal of the other:

Lopposing=L1+L2−2M.

The factor two is essential: mutual voltage appears in both coil voltages. With the values above, aiding gives 16 mH and opposing gives 4 mH. The drawing's layout cannot decide which connection is aiding; trace the common current through each dot.

Recover mutual inductance from two measurements

Subtracting the opposing result from the aiding result eliminates both self-inductances:

M=Laiding−Lopposing4.

Measurements of 16 mH and 4 mH therefore give M=(16−4)/4=3 mH. Their average gives L1+L2=10 mH, but does not determine each self-inductance separately.

The opposing equivalent cannot be negative, since

L1+L2−2M≥(L1−L2)2≥0.

Perfect coupling alone need not make it zero: unequal self-inductances leave a positive lower bound. For the series connection, inserting its common current into the coupled-energy formula gives w=12Leqi2, providing a direct check between the energy and voltage calculations. In separate circuits, mutual coupling also allows one circuit to transfer energy to another, as in a transformer.

Key Takeaways

  • Coupled energy includes ±Mi1i2 as well as the two self-energy terms.
  • Choose the mutual coefficient from references, then use signed current values.
  • Series aiding gives L1+L2+2M; opposing gives L1+L2−2M.
  • The factor two comes from one mutual-voltage term in each coil.
  • The difference between aiding and opposing inductances is 4M.
  • Physical coupling obeys M2≤L1L2, keeping stored energy nonnegative.

Capacitors and Inductors examples

5 Walkthroughs

1

Follow charge into a capacitor

17 steps
Move from charge and voltage to current, accumulated charge, and energy, with a piecewise worked example.
  1. 1
    IntroductionA voltage that remembers charge

    A capacitor’s voltage depends on charge already stored and on current arriving now. You can find current from a voltage slope or recover voltage from a current area. Follow these two directions, then use power to see when energy enters or leaves. Keep the current arrow entering the + voltage terminal so the passive-sign formulas apply.

  2. 2
    ExplanationSeparate the two plate charges

    The conducting plates of a capacitor hold equal and opposite charges. The dielectric between them is an insulator: current in the wires moves charge onto one plate and off the other without crossing the ideal dielectric.

    Capacitance is charge per volt: q=Cv. A larger capacitance holds more charge at the same voltage.

  3. 3
    ExampleConvert a component value to charge

    A 4.7 µF capacitor at 12 V holds q=(4.7×10−6)(12)=56.4 μC on its positive plate. At 24 V, that charge doubles to 112.8 µC while capacitance stays 4.7 µF.

    The prefix belongs to the capacitance value. Using 4.7 as farads would overstate charge by a factor of one million.

  4. 4
    ChallengeHold the charge fixed

    Two capacitors each hold 18 µC. One is 3 µF and the other 6 µF. What is the voltage of each?

    ---reveal---

    Use v=q/C: the voltages are 6 V and 3 V. At fixed charge, the larger capacitor has the lower voltage. A claim that a larger capacitance always gives a larger voltage overlooks which quantity is being held fixed.

  5. 5
    ExplanationRead current from a slope

    Differentiate charge to obtain i=C dv/dt. Current depends on how fast voltage changes. A rising voltage gives positive current, a flat voltage gives zero current, and a falling voltage gives negative current.

    For a straight segment, divide the signed voltage change by the elapsed time in seconds before multiplying by capacitance in farads.

  6. 6
    ExampleWork the rising voltage segment

    Across 2 µF, voltage rises from 0 to 10 V in 5 ms. The slope is 10−00.005=2000 V/s.

    Multiplying gives i=(2×10−6)(2000)=0.004 A=4 mA.

    The current is constant during this straight ramp, even though voltage is increasing throughout it.

  7. 7
    ExampleContinue through the hold and fall

    The same voltage holds at 10 V from 5 to 8 ms, then falls to zero at 10 ms. During the hold, slope and current are zero. During the fall, dv/dt=−10/0.002=−5000 V/s, so current is −10 mA.

    The voltage has corners but no jumps. Current jumps at the corners because the slope changes immediately.

  8. 8
    ChallengeHigh voltage or steep voltage?

    A 5 µF capacitor is at a constant 30 V. Another 5 µF capacitor is at 0 V but rising at 800 V/s. What current flows in each?

    ---reveal---

    The first carries zero current because its voltage slope is zero. The second carries 5×10−6(800)=4 mA. The instantaneous voltage value does not determine current; its rate of change does.

  9. 9
    ExplanationGo backward by adding charge area

    Integrating current gives charge delivered since a starting time. Divide by capacitance to get voltage change, then add the voltage already present:

    v(t)=v(t0)+1C∫t0ti(τ) dτ.

    A rectangular pulse gives current times duration. Below-axis area is negative. Without the initial value, you have found only the change.

  10. 10
    ExampleStart from a nonzero voltage

    A 1 µF capacitor starts at 5 V and receives 2 mA for 3 ms. Delivered charge is 2 mA×3 ms=6 μC.

    The voltage change is 6 μC/1 μF=6 V, so the endpoint is 11 V. During this constant-current interval the voltage follows a straight line from its 5 V starting point.

  11. 11
    ExampleCarry the endpoint into the next interval

    Current becomes −1 mA for the next 4 ms. That delivers −4 µC, so voltage falls by 4 V. Begin at the previous endpoint of 11 V to obtain 7 V.

    When current becomes zero, the capacitor stays at 7 V. Zero current removes the voltage slope; it does not remove charge already on the plates.

  12. 12
    ChallengeCancel areas without erasing the state

    A 2 µF capacitor begins at −3 V. It receives +8 µC, then −8 µC. What is its final voltage?

    ---reveal---

    The net delivered charge is zero, so the total voltage change is zero. The final voltage is −3 V. The first interval raises voltage by 4 V to +1 V; the second lowers it by 4 V. Equal areas restore the initial voltage, not necessarily zero.

  13. 13
    ExplanationLink power to stored energy

    Under passive references, p=vi is absorbed power. Positive power means energy enters; negative power means energy returns to the circuit.

    Integrating power from zero voltage gives w=12Cv2. The energy is nonnegative and depends on voltage magnitude. Opposite voltages of equal magnitude store equal energy.

  14. 14
    ExampleCheck a power-area result

    During the earlier 2 µF, 0-to-10 V ramp, current is 4 mA. Power rises from zero to 10(0.004)=40 mW over 5 ms.

    The triangular area is 12(5 ms)(40 mW)=100 μJ. The state formula agrees: 12(2×10−6)(10)2=100 μJ.

  15. 15
    ChallengeUse both signs for energy flow

    At one instant, a capacitor has passive voltage −6 V and current −2 mA. Is its stored energy rising or falling?

    ---reveal---

    Absorbed power is (−6)(−0.002)=+12 mW, so energy is rising. Negative current lowers signed voltage further below zero, increasing its magnitude. Current sign alone cannot determine whether the capacitor is releasing energy.

  16. 16
    ChallengeCombine area, final voltage, and energy

    A 4 µF capacitor starts at 2 V and receives 24 µC. What are its final voltage and stored energy?

    ---reveal---

    The voltage change is 24/4=6 V, giving a final 8 V. Energy is 12(4×10−6)(8)2=128 μJ. Using 6 V in the energy formula would use the voltage change instead of the final state.

  17. 17
    RecapKeep three questions separate

    For current, ask for the voltage slope. For voltage change, add signed current area and divide by capacitance. For energy, use the complete present voltage in the squared-state formula. Initial voltage belongs in every accumulated-charge calculation; the power sign tells you which way energy is moving.

2

Follow voltage into an inductor

13 steps
Use current slopes, voltage areas, and magnetic energy to understand a coil’s retained current.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionA coil keeps current flowing
  2. 2
    ExplanationTell flux linkage from voltage
  3. 3
    ExampleCalculate a current rise
  4. 4
    ExampleMake the fall ten times faster
  5. 5
    ChallengeCheck a claimed coil voltage
  6. 6
    ExplanationVoltage area changes current
  7. 7
    ExampleMove upward from a negative current
  8. 8
    ChallengeAdd areas with their signs
  9. 9
    ExplanationCalculate magnetic energy
  10. 10
    ExampleCheck energy against the current ramp
  11. 11
    ChallengeReverse current without changing energy
  12. 12
    ChallengeA pulse that removes stored energy
  13. 13
    RecapTrack the current state
3

Reduce a network, then recover its parts

12 steps
Identify connections, find equivalent values, and recover individual states without losing initial conditions.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionFind the nodes before the formula
  2. 2
    ExplanationCapacitor combination rules
  3. 3
    ExampleReduce the inner capacitor pair
  4. 4
    ExampleRecover voltages and charges
  5. 5
    ChallengeCheck an individual voltage
  6. 6
    Key InsightA terminal state can hide charge energy
  7. 7
    ExplanationUse inductor rules with current offsets
  8. 8
    ExampleReduce a mixed inductor network
  9. 9
    ExampleRecover the branch currents
  10. 10
    ChallengeKeep unequal starting currents
  11. 11
    ChallengeCompare the two kinds of division
  12. 12
    RecapReduce, then restore the internal states
4

Solve the instant after a switch

11 steps
Find the old DC state, preserve it through switching, and calculate the new currents and slopes.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionTwo drawings for two moments
  2. 2
    ExplanationReplace settled storage elements
  3. 3
    ExampleSolve the old resistor network
  4. 4
    ExampleRecord the stored energies
  5. 5
    ChallengeFollow a blocked branch
  6. 6
    ExplanationCarry the old state into the new drawing
  7. 7
    ExampleUse KCL to find capacitor current
  8. 8
    ExampleTurn the new current into a slope
  9. 9
    ChallengeSwitch an inductor into a closed loop
  10. 10
    ChallengeSeparate the initial and final voltages
  11. 11
    RecapState first, circuit equations second
5

Use the dots in coupled-coil calculations

16 steps
Find coupling strength, choose mutual-voltage signs, and connect coil equations to stored energy and series equivalents.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionA link without a connecting wire
  2. 2
    ExplanationMeasure the shared-flux link
  3. 3
    ExampleFind mutual inductance and open-coil voltage
  4. 4
    ChallengeCheck a proposed mutual inductance
  5. 5
    ExplanationRead dots as relative polarities
  6. 6
    ExampleWrite two self-plus-mutual equations
  7. 7
    ExampleCalculate each contribution
  8. 8
    ChallengeReverse one winding relationship
  9. 9
    ConnectionInsert the full coil voltage into a loop
  10. 10
    ExplanationInclude shared-field energy
  11. 11
    ChallengeAvoid choosing an energy sign twice
  12. 12
    ExplanationCount mutual voltage twice in series
  13. 13
    ExampleRecover coupling from measurements
  14. 14
    ChallengeCombine measurement, coupling, and energy
  15. 15
    Key InsightPerfect coupling need not cancel everything
  16. 16
    RecapLet references control the signs

Capacitors and Inductors practice questions

50 Practice Questions in 5 sets

Set 1: Charge, slopes, and stored energy10 Practice Questions

Question 1 of 10

An ideal inductor carries a steady −2 A in a closed path. What is its terminal voltage?
  1. A steady negative voltage
  2. 0 V
  3. A steady positive voltage
  4. A steadily rising voltage
Show answerHide answer
Answer: B
The steady current has zero slope, so v=L di/dt=0. Its negative sign specifies direction relative to the arrow, not a need for negative voltage. A nonzero current can persist in an ideal closed path and retain magnetic energy at zero voltage.

Question 2 of 10

An ideal 80 mH inductor starts at +0.25 A. A passive-reference voltage of −4 V is applied for 10 ms. What is its final current?
  1. −0.50 A
  2. +0.75 A
  3. +0.50 A
  4. −0.25 A
Show answerHide answer
Answer: D
The voltage area is −0.04 V·s, giving a current change of −0.04/0.08=−0.50 A. Adding the initial +0.25 A leaves −0.25 A. Reporting −0.50 A gives only the change and misses the existing current.

Question 3 of 10

An ideal 0.2 H inductor starts at +2 A. Its passive-reference voltage is −10 V for 20 ms, then +5 V for 20 ms. What is its total change in stored energy?
  1. −0.300 J
  2. −0.175 J
  3. +0.175 J
  4. −0.025 J
Show answerHide answer
Answer: B
The two pulses change current by −1 A and +0.5 A, leaving +1.5 A. Energy changes from 12(0.2)(2)2=0.4 J to 0.225 J, so the change is −0.175 J. Using only the first pulse gives −0.300 J and ignores the energy restored by the second.

Question 4 of 10

A 6.8 µF capacitor has a voltage of 15 V. What is the charge magnitude on either plate?
  1. 22.1 µC
  2. 102 µC
  3. 2.21 µC
  4. 10.2 µC
Show answerHide answer
Answer: B
Use q=Cv=(6.8 μF)(15 V)=102 μC. This is the charge magnitude on either plate, with opposite signs on the two plates. The value 10.2 µC is ten times too small: multiplying 6.8 by 15 gives 102, and the micro prefix stays with the charge unit.

Question 5 of 10

A parallel-plate capacitor keeps the same dielectric and plate spacing, but its plate area is tripled. How does its capacitance change?
  1. It becomes one-third as large.
  2. It becomes nine times as large.
  3. It stays the same size.
  4. It becomes three times as large.
Show answerHide answer
Answer: D
Capacitance is proportional to plate area in C=εA/d. With permittivity and gap unchanged, tripling area triples capacitance. The inverse factor of one-third would apply to tripling the gap, not the area; both dimensions must keep their own places in the relation.

Question 6 of 10

The voltage of an ideal 3 µF capacitor falls linearly from 9 V to −3 V in 4 ms. What current enters its positive voltage-reference terminal during this interval?
  1. −9 mA
  2. −4.5 mA
  3. +9 mA
  4. +4.5 mA
Show answerHide answer
Answer: A
The signed voltage change is −12 V in 0.004 s, giving a slope of −3000 V/s. Multiplying by 3 µF gives −9 mA. Using +9 mA loses the direction of the falling ramp; the negative result means actual current leaves the positive reference terminal.

Question 7 of 10

An ideal capacitor is held at a constant −24 V. What is its current?
  1. Reverse current
  2. Forward current
  3. Zero current
  4. Ramp current
Show answerHide answer
Answer: C
A constant voltage has zero time derivative, so i=C dv/dt=0 even at −24 V. The negative voltage does not require negative current; current is set by voltage slope. The capacitor may still store energy because its present voltage magnitude is nonzero.

Question 8 of 10

An ideal 5 µF capacitor starts at −2 V. A current of +3 mA enters its positive reference terminal for 5 ms. What is its final voltage?
  1. +3 V
  2. +5 V
  3. +1 V
  4. −5 V
Show answerHide answer
Answer: C
The pulse delivers 3 mA×5 ms=15 μC, raising voltage by 15/5=3 V. Add the initial −2 V to obtain +1 V. A result of +3 V is the voltage change alone and drops the initial state.

Question 9 of 10

What energy is stored in an ideal 8 µF capacitor at −5 V?
  1. 200 µJ
  2. 20 µJ
  3. 40 µJ
  4. 100 µJ
Show answerHide answer
Answer: D
Stored energy is 12Cv2=12(8×10−6)(−5)2=100 μJ. The square makes the energy positive despite negative voltage. The value 200 µJ comes from omitting the one-half factor in the energy formula.

Question 10 of 10

An ideal 75 mH inductor’s current rises linearly from −0.4 A to +0.8 A in 6 ms. What is its passive-reference voltage?
  1. +15 V
  2. +5 V
  3. −5 V
  4. −15 V
Show answerHide answer
Answer: A
Current changes by +1.2 A over 0.006 s, so its slope is +200 A/s. The passive voltage is 0.075(200)=+15 V. Treating the starting −0.4 A as a positive quantity would reduce the change to 0.4 A and incorrectly give +5 V.
Set 2: Apply calculus and energy to new waveforms10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A 4 µF ideal capacitor starts at −2 V. A constant +3 mA enters its positive terminal for 4 ms, followed by a constant unknown current for 6 ms. The capacitor ends at −1 V. What was the second current?
  1. −4/3 mA
  2. +4/3 mA
  3. +2/3 mA
  4. −2 mA
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

At an instant, an ideal capacitor has v = −8 V and dv/dt = +500 V/s, with C = 6 µF. What passive absorbed power does it have?
  1. +4 mW
  2. +24 mW
  3. −4 mW
  4. −24 mW
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

An ideal 0.25 H inductor is subjected to a signed voltage area of +0.15 V·s. What is its current change?
  1. +0.0375 A
  2. +0.60 A
  3. +1.67 A
  4. −0.60 A
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

An ideal 0.2 H inductor starts at −0.5 A and has passive voltage v(t)=12e−40t V for time t in seconds. What value does its current approach?
  1. +1.0 A
  2. +1.5 A
  3. −1.0 A
  4. +2.0 A
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A 0.12 H ideal coil carries +2 A. A constant −3 V passive voltage is applied until the current first reaches a value at which stored energy is one-quarter of its initial value. How long is the pulse?
  1. 120 ms
  2. 20 ms
  3. 80 ms
  4. 40 ms
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Initially uncharged 4 µF and 12 µF capacitors are connected in series across 20 V. What is the voltage across the 12 µF capacitor?
  1. 15 V
  2. 10 V
  3. 5 V
  4. 20 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

Uncoupled 40 mH and 120 mH inductors are in series. What voltage appears across the 120 mH coil when 8 V appears across the combination, with matching passive polarities?
  1. 2 V
  2. 6 V
  3. 8 V
  4. 4 V
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 2 µF ideal capacitor starts at 1 V. Its current entering the positive terminal rises linearly from zero to 4 mA in 3 ms. What is its voltage at 3 ms?
  1. 7 V
  2. 3 V
  3. 4 V
  4. −2 V
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A 9 V source feeds a 3 Ω resistor and a 40 mH ideal inductor in series to a node. A 6 Ω resistor and a 20 µF capacitor each connect from that node to the return. At DC steady state, what energy does the capacitor store?
  1. 360 µJ
  2. 180 µJ
  3. 720 µJ
  4. 810 µJ
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

Two linear coils have self-inductances 25 mH and 4 mH and coupling coefficient 0.6. What is their mutual inductance?
  1. 15 mH
  2. 10 mH
  3. 6 mH
  4. 2.4 mH
Show answerHide answer

Save this lesson to see this answer.

Set 3: Network states and switching values10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

An initially uncharged 8 µF capacitor is in series with a parallel pair of 3 µF and 9 µF capacitors. The network is brought to 15 V. What charge magnitude is on the 3 µF capacitor?
  1. 72 µC
  2. 54 µC
  3. 36 µC
  4. 18 µC
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Two 4 µF capacitors are in series with signed voltages +6 V and −2 V along the external terminal reference. What are the equivalent initial voltage and total physical stored energy?
  1. +4 V and 16 µJ
  2. +8 V and 80 µJ
  3. +4 V and 80 µJ
  4. +8 V and 64 µJ
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

What equivalent inductance is formed by uncoupled 45 mH and 90 mH coils in parallel?
  1. 30 mH
  2. 60 mH
  3. 15 mH
  4. 135 mH
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

Uncoupled parallel 50 mH and 150 mH coils start at +0.2 A and −0.6 A, both referenced downward. A +5 V top-positive pulse lasts 10 ms. What is the final current in the 150 mH branch?
  1. +1/3 A
  2. −4/15 A
  3. −14/15 A
  4. +11/15 A
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

Uncoupled 30 mH and 90 mH coils are in parallel, initially carrying +2 A and −1 A downward. A +3 V top-positive pulse lasts 10 ms. What total energy do the two coils then store?
  1. 155 mJ
  2. 105 mJ
  3. 61.25 mJ
  4. 215 mJ
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A 6 mA source feeds 2 kΩ in parallel with a branch containing 5 kΩ in series with an ideal 3 µF capacitor. What is the capacitor voltage in DC steady state?
  1. 30 V
  2. 42 V
  3. 12 V
  4. 6 V
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 30 V source has driven a 6 Ω resistor and an ideal 80 mH inductor in series to DC steady state. What energy is stored in the inductor?
  1. 0 J
  2. 0.2 J
  3. 2.0 J
  4. 1.0 J
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

An ideal 4 µF capacitor initially at +14 V is switched through 3 kΩ to a +5 V source of matching polarity. What current initially enters the capacitor’s positive terminal?
  1. +3 mA
  2. −3 mA
  3. −14/3 mA
  4. +5/3 mA
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

An ideal 0.4 H inductor initially carries 1.5 A. A switch removes its source and forms a closed loop through 24 Ω total resistance. What is its initial current slope in the existing current direction?
  1. +90 A/s
  2. −36 A/s
  3. −3.6 A/s
  4. −90 A/s
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

An 18 V source feeds 3 Ω and an ideal 0.2 H inductor in series to a node with 6 Ω and 50 µF in parallel to the return. After DC steady state, a switch adds 4 Ω from that node to the return. What is the capacitor’s initial absorbed power?
  1. −36 W
  2. −24 W
  3. +36 W
  4. −18 W
Show answerHide answer

Save this lesson to see this answer.

Set 4: Mutual inductance, dot signs, and energy10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

An open coil is coupled to a driven coil with mutual inductance 7 mH. The driven current changes at −300 A/s. What is the induced-voltage magnitude in the open coil?
  1. 0 V
  2. 2.1 V
  3. 0.21 V
  4. 21 V
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

Two linear coils have L₁ = 16 mH and L₂ = 9 mH. An open-coil test gives 1.8 V induced magnitude when the other coil’s current changes at 200 A/s. What is their coupling coefficient?
  1. 0.75
  2. 0.5625
  3. 0.90
  4. 0.50
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

Both reference currents enter dotted terminals, and both coil voltages are positive at dots. Let L₁ = 10 mH, M = 2 mH, di₁/dt = 120 A/s, and di₂/dt = −80 A/s. What is v₁?
  1. 1.36 V
  2. 1.20 V
  3. 1.04 V
  4. −1.04 V
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A source, resistor R, and coil 1 form a loop carrying i₁ into coil 1’s dot. Coil 2’s current i₂ enters its undotted terminal. Each coil voltage is passive. What is the KVL expression for v_s?
  1. Ri1+L1 di1/dt+M di2/dt
  2. Ri1+L1 di1/dt−M di1/dt
  3. Ri1−L1 di1/dt+M di2/dt
  4. Ri1+L1 di1/dt−M di2/dt
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

Both coil-current references enter dots and both voltages are positive at dots. L₁ = 20 mH, L₂ = 5 mH, and M = 6 mH. At an instant v₂ = 0 and di₁/dt = 100 A/s. What is v₁?
  1. 2.72 V
  2. 2.00 V
  3. 0.72 V
  4. 1.28 V
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

Coils have L₁ = 10 mH, L₂ = 4 mH, and M = 3 mH. Current 1 is +2 A into a dot; current 2 is +3 A out of a dot. What total energy is stored?
  1. 56 mJ
  2. 20 mJ
  3. 38 mJ
  4. 18 mJ
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A pair of equal linear coils measures 28 mH in series aiding and 12 mH in series opposing. What is the coupling coefficient?
  1. 0.4
  2. 0.8
  3. 0.2
  4. 0.6
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

Two perfectly coupled coils have self-inductances 25 mH and 9 mH. They are connected in series opposing. How much energy is stored at 3 A?
  1. 0 mJ
  2. 153 mJ
  3. 18 mJ
  4. 9 mJ
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

Both current references enter dots. Two coils have L₁ = 18 mH, L₂ = 8 mH, M = 9 mH, i₁ = +1 A, and i₂ = −2 A. What total magnetic energy do they store?
  1. 43 mJ
  2. 7 mJ
  3. 25 mJ
  4. 16 mJ
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

An ideal 12 mH coil carries 0.8 A. Its current is forced to fall linearly to zero in 40 µs. What is the average passive voltage during the fall?
  1. +240 V
  2. −24 V
  3. −240 V
  4. −0.24 V
Show answerHide answer

Save this lesson to see this answer.

Set 5: Mixed challenges: infer states and check models10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

An ideal 3 µF capacitor starts at −4 V. Current entering its positive terminal rises linearly from zero to 6 mA over 4 ms, then becomes −1.5 mA for 2 ms. What is its final voltage?
  1. +1 V
  2. 0 V
  3. −1 V
  4. +3 V
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

An ideal capacitor’s voltage magnitude triples while capacitance stays fixed. By what factor does its stored energy change?
  1. 3
  2. 9
  3. 6
  4. 1/9
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

An ideal 60 mH coil starts at −0.2 A. Its passive voltage is v(t)=6−600t V from t = 0 to t = 0.020 s. What is the greatest stored energy during that interval?
  1. 1.2 mJ
  2. 7.5 mJ
  3. 0.3 mJ
  4. 2.7 mJ
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

Two ideal capacitors, 2 µF and 6 µF, are already in series with signed voltages +3 V and −1 V along the terminal reference. A further +6 µC flows through the series path in the direction that raises both signed voltages. What total physical energy is then stored?
  1. 36 µJ
  2. 27 µJ
  3. 9 µJ
  4. 48 µJ
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

Parallel uncoupled coils L₁ = 24 mH and L₂ = 72 mH start at zero current. At a later instant their total current has reached 2 A under a common voltage waveform. What is the current in L₁?
  1. 0.5 A
  2. 1.5 A
  3. 1.0 A
  4. 2.0 A
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

An 18 V source feeds 3 Ω and an ideal 0.12 H inductor in series to a node with 6 Ω and 80 µF in parallel to the return. After DC steady state, the source steps to 6 V with unchanged polarity. What are the initial slopes di_L/dt and dv_C/dt, using current toward the node and node-positive capacitor voltage?
  1. 0 A/s and −50,000 V/s
  2. 0 A/s and −25,000 V/s
  3. −50 A/s and 0 V/s
  4. −100 A/s and 0 V/s
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A 10 µF ideal capacitor settles to 8 V through a resistor. A switch disconnects that charging branch and leaves the capacitor across a parallel 4 kΩ resistor and 1 mA current sink directed from its positive terminal to its negative terminal. What is the capacitor’s initial voltage slope?
  1. −200 V/s
  2. −100 V/s
  3. −300 V/s
  4. +300 V/s
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

Two stationary coupled coils have L₁ = 36 mH and L₂ = 16 mH. An open-coil measurement gives 3 V induced magnitude for a driving-current slope of 250 A/s. What is k?
  1. 0.5
  2. 0.75
  3. 0.25
  4. 1.0
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

Current i₁ enters coil 1’s dot, and current i₂ leaves coil 2’s dot; both voltages are passive. L₁ = 12 mH, L₂ = 3 mH, and M = 4 mH. At an instant v₁ = 0 and di₂/dt = +90 A/s. What is v₂?
  1. +0.39 V
  2. +0.27 V
  3. −0.15 V
  4. +0.15 V
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

Two linear coils have L₁ = 20 mH and L₂ = 5 mH. Their series-opposing inductance is measured as 9 mH. How much energy do they store at 2 A when reconnected in series aiding?
  1. 82 mJ
  2. 50 mJ
  3. 64 mJ
  4. 18 mJ
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

63 Key Terms, each with its definition

A

Absorbed power
Absorbed power is the rate at which energy enters a component; under passive references it equals vi and may be positive or negative.
At −6 V and −2 mA, a capacitor absorbs +12 mW, so its stored electric-field energy is increasing.

C

Capacitance
Capacitance is the charge stored per volt across a capacitor, expressed as C=q/v and measured in farads.
At the same voltage, a 6 µF capacitor holds twice the charge magnitude of a 3 µF capacitor.
Capacitor
A capacitor is a two-terminal component that stores equal and opposite charges on conductors separated by an insulating material.
A 4.7 µF capacitor at 12 V holds a plate-charge magnitude of 56.4 µC without charge crossing its ideal insulator.
Capacitor current
Capacitor current is the rate of plate-charge change, given by i=C dv/dt for constant capacitance and passive references.
A high capacitor voltage can coexist with zero current when that voltage is no longer changing.
Capacitor-voltage continuity
Capacitor-voltage continuity means the voltage cannot jump; a finite jump in zero time would require an unbounded current.
When a load is switched onto a charged capacitor, current can jump while voltage starts from its old value.
Choke
A choke is an inductor used in a supply path to pass steady current while developing voltage in response to current changes.
At steady DC a real choke’s voltage drop comes from winding resistance; its ideal inductive part has zero voltage.
Circulating current
A circulating current flows around an internal inductor loop with branch contributions that cancel at the external terminals.
Opposing parallel-coil currents can store more total energy than the terminal equivalent’s current indicates.
Constant-current voltage ramp
A constant-current voltage ramp is a linear capacitor-voltage change whose slope equals the constant current divided by capacitance.
A timer can charge a capacitor with constant current to obtain a steadily increasing voltage.
Constant-voltage current ramp
A constant-voltage current ramp is a linear change of ideal-inductor current whose slope equals applied voltage divided by inductance.
A constant 12 V across an ideal 0.3 H inductor raises its signed current at a steady 40 A/s.
Core saturation
Core saturation is the high-current behavior in which a magnetic core gives less added flux linkage per added current, lowering inductance.
A saturated coil no longer follows the same constant-inductance relation used for its lower-current operation.
Coupling capacitor
A coupling capacitor is a capacitor placed in a signal path to block steady current while allowing current associated with voltage changes.
A series coupling capacitor prevents a steady DC current from flowing through that ideal signal branch.
Coupling coefficient
The coupling coefficient is the dimensionless ratio k=M/L1L2, ranging from zero for no shared flux to one for perfect coupling.
Self-inductances 8 mH and 2 mH with M = 3 mH give a coupling coefficient of 0.75.
Coupling energy bound
The coupling energy bound is M2≤L1L2, the condition that keeps coupled-coil stored energy nonnegative for every signed current pair.
A proposed mutual inductance greater than the geometric mean of the self-inductances fails the passive-coil model.
Crosstalk
Crosstalk is unwanted signal transfer caused here by magnetic coupling between nearby conductors carrying changing currents.
Moving signal conductors apart can reduce the mutual link that induces an unwanted voltage in a neighboring circuit.

D

DC steady state
DC steady state is the condition in which a circuit’s voltages and currents have stopped changing under its constant sources.
At DC steady state, capacitor currents are zero and ideal-inductor voltages are zero, though stored energy can remain.
Dielectric
A dielectric is the insulating material between a capacitor’s conductors; its permittivity helps determine the capacitance.
Replacing air with a material of higher relative permittivity raises capacitance for unchanged plate geometry.
Dot convention
The dot convention marks relative winding polarity: a current reference entering one dot induces a + reference at the other coil’s dot.
Both currents entering dots give positive mutual coefficients when both voltage references are passive.
Duality
Duality is the matching pattern between capacitor and inductor laws when voltage and current exchange roles and capacitance is replaced by inductance.
Capacitor voltage integrates current, while inductor current integrates voltage, with an initial state in both.

E

Electric-field energy
Electric-field energy is the energy stored by an ideal capacitor, equal to 12Cv2 and determined by its present voltage.
A charged capacitor can retain energy after its charging source is disconnected and current becomes zero.
Energy return
Energy return occurs when a storage element delivers energy back to the circuit, giving negative absorbed power under passive references.
An inductor with positive current and negative passive voltage releases some of its magnetic-field energy.
Equivalent capacitance
An equivalent capacitance is one capacitance that reproduces a capacitor group’s voltage–current behavior at its external terminals.
Two 6 µF capacitors in series have a 3 µF equivalent, with initial terminal voltage equal to their signed voltage sum.
Equivalent inductance
An equivalent inductance reproduces an inductor network’s terminal voltage–current behavior with a compatible initial terminal current.
Uncoupled 60 mH and 30 mH parallel coils behave at their terminals as a 20 mH inductor.

F

Farad
A farad is the SI unit of capacitance, equal to one coulomb per volt; microfarads and nanofarads describe smaller values.
A 2 µF capacitor receives 2 µC for each 1 V increase in its voltage under the linear model.
Flux linkage
Flux linkage is the sum of magnetic flux linked by a coil’s turns, related to current by λ=Li in a linear inductor.
Doubling current in a constant-inductance coil doubles flux linkage while its stored energy increases fourfold.
Flyback diode
A flyback diode provides a continuing path for current in a switched DC coil, limiting the voltage spike when the drive is removed.
A relay coil can send its retained current through a flyback diode after the driving switch opens.

H

Henry
A henry is the SI unit of inductance, equal to one volt-second per ampere; one millihenry is one-thousandth of a henry.
A 1 H coil needs 1 V to make current rise at 1 A/s, using the passive current and voltage references.

I

Ideal energy storage
Ideal energy storage holds energy without dissipating it, so an ideal capacitor can return all the energy it previously absorbed.
Returning a capacitor to its original voltage gives zero net energy absorption over the complete interval.
Inductance
Inductance is flux linkage per ampere in a linear coil, represented by L and appearing in the passive law v=L di/dt.
At the same current slope, a 100 mH coil develops twice the voltage of a 50 mH coil.
Inductive current division
Inductive current division allocates current changes inversely with inductance in uncoupled parallel coils subjected to one common voltage.
Under a shared voltage pulse, a 30 mH coil gains twice as much current as a 60 mH coil.
Inductor
An inductor is a coil that links current to magnetic flux and, in its ideal linear form, produces voltage proportional to current slope.
A coil can have a large voltage during a rapid current decrease even when its current is relatively small.
Initial condition
An initial condition is a retained capacitor voltage or inductor current that fixes the storage state as the post-switch circuit begins.
The initial current of a switched inductor comes from its pre-switch state, not from the new DC final value.
Initial current
An initial current is the known inductor current at an interval’s start, added to the change found by integrating voltage over time.
A −1 A initial current plus a +2 A change produces +1 A, not the +2 A change alone.
Initial rate of change
An initial rate of change is the slope just after switching, obtained from iC(0+)/C or vL(0+)/L under passive references.
A capacitor can have a nonzero negative initial voltage slope even though its voltage has no jump.
Initial voltage
An initial voltage is a capacitor’s known voltage at the start of an interval, added to the voltage change obtained from current area.
Starting at 5 V and gaining 6 V leaves 11 V; the current integral does not replace the 5 V initial value.
Integration variable
An integration variable is a temporary variable inside an integral, such as τ, distinguishing accumulated time from its endpoint.
In a current integral ending at time t, the symbol τ runs through the times whose charge contributions are added.

J

Joule
A joule is the SI unit of energy, equal to one watt-second; capacitor and inductor stored energies are expressed in joules.
The triangular area of a 20 W peak lasting 10 ms is 0.1 J when the power rises linearly from zero.

L

Loop equation
A loop equation applies Kirchhoff’s voltage law around a closed path, including both self and mutual contributions for each coupled coil.
A source–resistor–coil loop needs the other coil’s current derivative when the coils share magnetic flux.

M

Magnetic-field energy
Magnetic-field energy is the energy held by an inductor’s current, given by w=12Li2 for an ideal linear uncoupled coil.
A 50 mH inductor at 2 A stores 0.1 J even during an interval of zero terminal voltage.
Mutual energy term
The mutual energy term is the interaction contribution ±Mi1i2 in the total stored energy of two linear coupled coils.
Two self-energy terms totaling 17 mJ become 23 mJ when a positive 6 mJ mutual contribution is included.
Mutual inductance
Mutual inductance measures the link between changing current in one coil and induced voltage in another through shared magnetic flux.
With M = 3 mH, a 500 A/s rise in one coil induces 1.5 V magnitude in the other open coil.
Mutual voltage
A mutual voltage is the part of a coil’s terminal voltage induced by changing current in the other coil, with sign chosen from the dots.
A negative current slope can make a mutual contribution negative even when the equation has a positive M coefficient.

O

Open circuit
An open circuit is a branch carrying zero current; it can still have nonzero terminal voltage, as a capacitor does at constant voltage.
A settled capacitor branch is open even while its terminals remain at different electrical potentials.

P

Parallel connection
A parallel connection puts components across the same two nodes, giving each the same voltage while their branch currents add.
Parallel 2 µF and 10 µF capacitors both have 7.5 V when connected across a common 7.5 V node pair.
Parallel-capacitor charge division
Parallel-capacitor charge division assigns plate charge in proportion to capacitance because all components share the same voltage.
At 7.5 V, parallel 2 µF and 10 µF capacitors hold 15 µC and 75 µC respectively.
Parasitic capacitance
Parasitic capacitance is unintended capacitance in a real circuit that can receive inductor current during a switching interruption.
An interrupted coil current can charge parasitic capacitance and raise voltage until another effect limits the spike.
Passive sign convention
The passive sign convention places a component’s current reference into its positive voltage-reference terminal, making vi absorbed power.
If the calculated current is negative, actual current leaves the terminal marked positive for voltage.
Perfect coupling
Perfect coupling is the ideal limit k=1 in which all the magnetic flux of each coil links the other, giving M=L1L2.
Even with perfect coupling, unequal self-inductances leave a positive series-opposing equivalent inductance.
Permittivity
Permittivity is the material property represented by ε in the parallel-plate formula C=εA/d.
A dielectric with higher permittivity gives more capacitance for the same plate area and separation.

S

Self voltage
A coil’s self voltage is its voltage contribution from its own changing current, written L di/dt under passive references.
A coil’s total voltage can be zero when its nonzero self voltage is canceled by an opposing mutual voltage.
Self-inductance
Self-inductance links a coil’s flux linkage to its own current, distinguishing the self-voltage term from a term induced by another coil.
In a coupled-coil equation, L₁ multiplies the derivative of current 1, while M multiplies the derivative of current 2.
Series aiding
Series aiding connects coupled coils so the common current enters both dots in turn, giving Leq=L1+L2+2M.
Coils of 8 mH and 2 mH with M = 3 mH give a 16 mH equivalent in the aiding connection.
Series connection
A series connection joins components in an unbranched path so the same current flows through them and their signed voltages add.
Initially uncharged series capacitors receive equal charge, although different capacitances give different voltages.
Series opposing
Series opposing connects coupled coils so current enters one dot and one undotted terminal, giving Leq=L1+L2−2M.
Coils of 8 mH and 2 mH with M = 3 mH give a 4 mH equivalent in the opposing connection.
Series-capacitor voltage division
Series-capacitor voltage division assigns voltage inversely with capacitance when the series capacitors begin uncharged and receive equal charge.
A 3 µF capacitor takes twice the voltage of 6 µF when the initially uncharged pair is in series.
Series-inductor voltage division
Series-inductor voltage division assigns voltage in proportion to inductance because uncoupled series coils share one current slope.
A 20 mH series coil takes twice the voltage of a 10 mH coil during the same changing current.
Short circuit
A short circuit is a zero-voltage connection that can carry current; an ideal inductor behaves this way when its current is constant.
Replace the ideal inductive part with a wire during DC analysis, retaining any separately modeled winding resistance.
Signed current area
A signed current area is the time integral of current, measuring net charge delivered with below-axis portions counted negatively.
A +6 µC area followed by −4 µC delivers a net +2 µC, which raises voltage by 2 V on 1 µF.
Switching instant
A switching instant is the time a connection changes; 0− and 0+ identify the moments immediately before and after it.
Adding a resistor at time zero changes the load on a node, but a capacitor connected to that node retains its voltage at 0⁺.

V

Volt-second area
A volt-second area is signed voltage integrated over time; dividing it by inductance gives the corresponding change in coil current.
A 4 V pulse lasting 10 ms contributes 0.04 V·s, raising current by 2 A through a 20 mH coil.
Voltage rating
A capacitor’s voltage rating is the maximum operating voltage specified for that real component, unlike the ideal model’s unlimited voltage.
In an unequal series pair, check the smaller capacitor’s larger voltage against its own voltage rating.
Voltage slope
A voltage slope is voltage change per unit time; multiplying it by ideal capacitance gives capacitor current under passive references.
A 10 V rise over 5 ms has a slope of 2000 V/s, so 2 µF carries a constant 4 mA during that rise.

W

Watt
A watt is the SI unit of power, equal to one joule per second; it describes energy-transfer rate rather than stored energy.
A coil absorbing 10 W at an instant is gaining energy at 10 J/s, regardless of how much it already stores.
Winding resistance
Winding resistance is the real electrical resistance of a coil’s wire, commonly modeled in series with its ideal inductance.
A steady coil current creates a winding-resistance voltage drop even though the ideal inductive part has zero voltage.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started