- Explain how a changing current induces an emf in a neighboring coil and in the coil itself, calculate mutual and self-inductance for simple coil shapes, and find the energy stored in an inductor's magnetic field.
- Calculate the mutual inductance of two coilsDefine mutual inductance, use it to find the emf a changing current induces in a nearby coil, and calculate it for coaxial solenoids.
- Find the self-inductance of a coil and the emf it induces in itselfDefine self-inductance, use the back emf of an inductor in circuit equations, and calculate the inductance of a solenoid and a toroid.
- Calculate the energy stored in an inductor and its magnetic fieldDerive the energy stored in an inductor, connect it to the energy density of the magnetic field, and use field energy to find inductance.
- Calculate the mutual inductance of two coils
- Apply Kirchhoff's loop rule to circuits with inductors to find how current grows and decays in RL circuits, and describe how charge, current and energy oscillate in LC and RLC circuits.
- Describe how current grows in an RL circuitSet up and solve the loop equation for a resistor and inductor connected to a battery, interpret the time constant and find currents just after switching and long afterward.
- Describe how current decays in an RL circuit and where its energy goesFind the decaying current when the source is removed, calculate the energy dissipated, and explain the large emfs and sparks caused by breaking an inductive circuit.
- Explain the oscillations of an LC circuitDescribe how energy moves between a capacitor and an inductor, solve the LC equation for charge and current, and use the mass-on-a-spring analogy.
- Describe damped oscillations in an RLC circuitAdd resistance to the LC circuit, and distinguish underdamped, critically damped and overdamped behavior using the damped oscillation formulas.
- Describe how current grows in an RL circuit
- Describe sinusoidal voltages and currents by amplitude, frequency, phase and rms value, find how a resistor, an inductor and a capacitor each respond to an AC source, and represent these relationships with phasor diagrams.
- Describe AC voltages and currents and their rms valuesDescribe a sinusoidal source by amplitude, frequency and period, explain rms values and use them to calculate average power in a resistor.
- Relate current and voltage for a resistor, a capacitor and an inductorFind the current through each element driven by an AC source, define capacitive and inductive reactance, and explain the phase difference and the frequency dependence of each element.
- Represent AC quantities with phasorsUse rotating phasors to show amplitude and phase, read instantaneous values from them, and add sinusoids of the same frequency as vectors.
- Describe AC voltages and currents and their rms values
- Use phasor diagrams to find the impedance, current and phase angle of a series RLC circuit driven by an AC source, explain resonance and its sharpness, and calculate average power and power factor.
- Find the impedance, current and phase angle of a series RLC circuitCombine the phasors of a series resistor, inductor and capacitor to find the impedance, the current, the phase angle and the voltage across each element.
- Explain resonance in a driven series RLC circuitFind the resonance frequency of a series RLC circuit, describe how the current depends on driving frequency, and use the quality factor and bandwidth to describe the sharpness of resonance.
- Calculate average power and power factor in AC circuitsFind the average power a source delivers to an AC circuit, explain the power factor and why a low power factor costs energy in wiring.
- Find the impedance, current and phase angle of a series RLC circuit
- Calculate voltages, currents and power in ideal transformers, describe the losses in real ones, and explain why electric power is transmitted at high voltage and how to stay safe with AC.
- Calculate voltages and currents in an ideal transformerExplain how a transformer works by mutual induction, apply the turns ratio to voltages and currents, and describe the losses in real transformers.
- Explain high-voltage power transmission and AC safetyCalculate the power lost in transmission lines, explain why transformers make high-voltage transmission efficient, and state the main safety rules for AC and inductive circuits.
- Calculate voltages and currents in an ideal transformer
Inductance and AC Circuits study guide
1Describe inductance and the energy stored in magnetic fields
A changing current links circuit behavior to magnetic flux. Learn how coil geometry sets mutual and self-inductance, how the induced emf opposes a current change, and how the field stores the work done by a source. Calculating both flux linkage and field energy gives two routes to inductance, including arrangements where the magnetic field varies across the space between conductors.
1.1 Link two coils through a changing magnetic field
A current in one coil produces a magnetic field through nearby coils. A changing current changes that flux and induces an emf. Mutual inductance measures the strength of this connection; the second coil does not need a wire connecting it to the first.
From flux to induced emf
Let be the flux through one turn of coil 2 caused by current . With turns, its flux linkage is . For a linear magnetic response,
The minus sign expresses Lenz's law. If the second coil forms a closed circuit, its induced current opposes the change in the linked flux. If the first current decreases, the induced field supports the original field. A large steady current produces flux but no induced emf.
Inductance is measured in henries: . Mutual inductance depends on turns, size, spacing and orientation. A magnetic core strengthens the coupling; with iron, the response can also depend on current.
Choose the easier field calculation
For the same two coils, . You can calculate the field from either coil, then find its flux through the other. Choose the direction that makes the field simplest.
A long solenoid has 1000 turns over 0.50 m. A coaxial 200-turn coil of radius 1.5 cm sits near its center. Imagine current in the long solenoid. Its field at the inner coil is . Each inner turn encloses area , so
Substitution gives . At a current increase of 50 A/s, the emf magnitude is . Use the inner coil's area: it is the area enclosed by each receiving turn. Using the outer area would count field that never passes through that turn.
The general method is to find the field, integrate it over one receiving turn, multiply by the receiving turn count, and divide by the source current. Distinguish flux through one turn from flux linkage through the whole coil. Omitting the receiving turn count loses a factor of 200 in this example.
Measure how much flux is shared
The coupling coefficient describes the connection relative to the coils' own inductances:
Coils on a common closed iron core can have coupling close to 1. Separating coils or turning their axes toward perpendicular reduces the shared flux. Wireless chargers use strong mutual coupling to transfer energy; circuit designers reduce unwanted coupling to limit interference.
Key Takeaways
- Mutual inductance converts a current-change rate in one coil into an emf in another.
- Find flux through one receiving turn, then multiply by its number of turns.
- The same mutual inductance applies in both directions.
- Lenz’s law fixes the induced direction by opposing the flux change.
- Geometry and magnetic material determine coupling strength.
1.2 Find a coil’s self-inductance and back emf
A coil's field passes through its own turns. When its current changes, that linked flux changes too, producing a self-induced emf. An inductor is a component designed to make this effect significant.
What an inductor opposes
For constant inductance,
The emf opposes a change in current. During an increase it acts against the current; during a decrease it acts to sustain it. A steady current gives zero induced emf, even when the current and stored magnetic energy are large.
For Kirchhoff's loop rule, crossing the inductor in the direction of the current gives a potential change . This is a drop during growth and a rise during decay. The passive voltage across the inductor is ; the self-induced emf has the opposite sign. A real coil also has wire resistance, modeled in series with its ideal inductance.
A finite emf cannot make the current jump. Such a jump would require an infinite rate of change. This continuity rule will determine the current immediately after a switch moves.
Derive the solenoid formula
For a long air-core solenoid, . Multiply the field by its area for one turn's flux, then multiply by the number of turns again:
One factor of comes from producing the field; the other comes from linking all the turns. Doubling the turns while holding length and area fixed therefore multiplies inductance by four. With turns per length , the same result is .
For 500 turns over 0.25 m with radius 1.0 cm, first convert the radius: . Then . A rise from zero to 2.0 A in 4.0 ms gives and an emf magnitude of about 0.197 V.
Integrate a toroid's nonuniform field
Inside a toroid, . For rectangular cross-section height , a radial strip has area . Thus
For 1000 turns, height 2.0 cm, inner radius 5.0 cm and outer radius 8.0 cm, this gives about 1.88 mH. Using one uniform field across a wide toroid would miss its radial variation.
Evaluate the toroid in stages: , , and . These factors give 0.0040 H before the logarithm. Multiplying by gives 0.00188 H. The radius ratio has no units, as the argument of a logarithm must.
A ferromagnetic core can raise inductance by hundreds or thousands through its relative permeability. The simple multiplication is approximate because the core's magnetic response can change with current. The relation never replaces the derivative law: it would confuse inductance with resistance and even gives the wrong units for voltage.
Key Takeaways
- Self-induced emf opposes changes in current and vanishes for steady current.
- Current through an inductor remains continuous when emfs are finite.
- A long solenoid has inductance proportional to turns squared.
- A toroid requires a flux integral because its field varies with radius.
- Keep the loop-rule sign consistent with the chosen crossing direction.
- A real coil combines inductance with wire resistance.
1.3 Find energy in an inductor and in its field
Building a current requires the source to work against the inductor's back emf. That work becomes magnetic field energy. When the current later decreases, the field can return energy to the circuit.
Integrate the power
For an ideal inductor, the power entering its field is . The small energy increase is therefore . Integrating from zero current gives
Reversing the current leaves the energy unchanged; doubling its magnitude quadruples the energy. At steady current the field still stores energy even though no power enters an ideal inductor. Zero instantaneous power means the stored amount is no longer changing.
Compare the storage laws:
| System | Stored energy | Storage mechanism |
|---|---|---|
| Inductor | Magnetic field | |
| Capacitor | Electric field | |
| Moving mass | Kinetic energy |
Inductance plays a role like mass, while current plays a role like velocity. This analogy helps explain why current persists after a source is removed.
Locate the energy in space
In vacuum, and approximately in air, magnetic energy per unit volume is
For a nearly uniform solenoid field, multiply energy density by the field-filled volume . In the 500-turn solenoid of length 0.25 m and radius 1.0 cm carrying 2.0 A, the field is about 5.03 mT. Its energy density is about 10.1 J/m³. The volume is about , so the energy is about .
The circuit calculation gives the same answer: . More generally, inserting into the field integral gives , recovering the solenoid inductance.
Energy density and energy have different units. In , the units reduce to joules per cubic meter. Multiplying by a volume gives joules; integrating over a length alone would not. For a solenoid, the field is approximately uniform, but for the coaxial field below each radial region contributes a different density.
Use field energy to find inductance
If the field is easier to calculate than flux linkage, find its energy first and use . Consider a coaxial cable with thin conductors at radii and . Equal outward and return currents confine its field between the conductors:
A cylindrical shell of length has volume . Combining the field and volume gives
Comparing with gives . The logarithm comes from integrating a nonuniform field; multiplying by one field value and the entire volume would be incorrect. This result describes the field between thin conductors, so it does not add magnetic energy inside solid conductors.
Key Takeaways
- An ideal inductor stores magnetic energy equal to one-half inductance times current squared.
- In air or vacuum, integrate magnetic energy density over the field region.
- Field energy can determine inductance through the relation L = 2U/I².
- A steady current can store energy while the inductor voltage is zero.
2Analyze RL circuits and LC oscillations
Switching a circuit reveals the effect of stored magnetic energy over time. Start with current growth and decay in RL loops, then follow energy between a capacitor and an inductor. Adding resistance connects these electrical oscillations to damped mechanical motion. Initial conditions and the path left by a switch determine which equation describes each stage.
2.1 Follow current as an RL circuit switches on
Connect a battery, resistor and inductor in series. The battery starts building current, but the inductor's back emf prevents an immediate jump. As the current approaches its final value, the back emf fades.
Build and solve the loop equation
Close the switch at with zero initial current. Going around the loop in the current direction gives
Initially the resistor drop is zero, so . Later, the growing resistor drop leaves less voltage to change the current. Rearranging and separating variables gives
Integration with yields
The integration produces . Exponentiating gives the shrinking fractional gap . This is why the growth formula contains one minus the exponential: the exponential tracks what is still missing from the final current.
The time constant is in seconds because a henry is an ohm-second. After one time constant the current reaches about 63.2% of its final value; after five it exceeds 99.3%. Larger inductance slows the rise. Smaller resistance also lengthens the time constant, while raising the final current.
Calculate current and voltage together
For a 12 V source, 6.0 Ω resistor and 0.30 H inductor, and . The initial slope is 40 A/s. At 0.050 s, ; at 0.10 s it is about 1.73 A.
The voltages divide as
At one time constant these are about 7.59 V and 4.41 V. Their sum remains 12 V. Long afterward the ideal inductor has zero voltage drop, so the resistor alone sets the final current.
To find a waiting time, isolate the exponential before taking a logarithm:
Reaching 90% takes in this circuit. An exponential approaches its limiting value; it does not reach it exactly at one time constant.
Use switching limits in a branched circuit
A 12 V battery feeds a 4.0 Ω resistor, followed by two parallel branches: an 8.0 Ω resistor and an ideal inductor. The inductor initially carries no current.
Immediately after closing the switch, the inductor branch carries zero current. The two resistors therefore carry . Long afterward the inductor acts as a wire across the 8.0 Ω resistor. That resistor has zero voltage and zero current; the battery and inductor carry .
The open-branch picture applies initially because this inductor started with zero current. If an inductor was already carrying current before switching, preserve that initial current instead. Check the actual initial condition before replacing a branch with a limiting model.
Key Takeaways
- Write the loop equation before choosing an exponential solution.
- The RL time constant is L/R; the final current is ε/R.
- An initially unenergized inductor starts with zero current and a nonzero current slope.
- After a long time on DC, an ideal inductor acts as a wire.
- In a branched circuit, recalculate the resistor network at each switching limit.
2.2 Follow current and energy after the source is removed
Removing a battery does not remove the magnetic energy already in an inductor. If a closed resistive path remains, the inductor drives current through it while the field loses energy.
Solve the decay equation
Let the initial current be and the resistance of the remaining loop be . Kirchhoff's rule gives
The current keeps its original direction while decreasing. Since , the inductor supplies a potential rise along that current. Its polarity reverses compared with the growth stage; its current does not reverse.
For , and , the time constant is 0.050 s. After 0.10 s, . Solving gives a half-time of . After five time constants, less than 1% of the initial current remains.
Track the energy separately
The initial energy is . Because energy depends on current squared,
Energy decreases faster than current. When the current has halved, only one-quarter of the initial energy remains. The resistor receives the difference as heat. Integrating its power confirms the total:
The example releases 0.60 J into the resistor. A continuing current after disconnection does not require a continuing battery supply; its energy comes from the field.
Identify the new loop
A 12 V battery and 4.0 Ω resistor feed an 8.0 Ω resistor in parallel with a 0.40 H ideal inductor. After a long time, the inductor carries 3.0 A and the 8.0 Ω resistor carries no current.
Now open the battery branch while leaving the inductor and 8.0 Ω resistor connected. The inductor current is still 3.0 A at the switching instant. It returns through the 8.0 Ω resistor, so . The initial resistor voltage magnitude is 24 V. Its current runs opposite to its direction during the earlier growth stage. The 4.0 Ω resistor is no longer part of the decay loop.
Understand an interrupted path
If the current is forced to fall quickly, the emf can be large. Reducing 2.0 A to zero in 1.0 ms in a 0.30 H coil gives an average magnitude . This can produce a spark across switch contacts. A designed decay path limits the voltage by giving the stored energy somewhere to go. Ignition coils use rapid interruption to produce a large voltage deliberately.
Key Takeaways
- Decay current keeps its direction while the inductor voltage reverses.
- Use the resistance in the closed path that remains after switching.
- Current falls as exp(−t/τ), while magnetic energy falls as exp(−2t/τ).
- The initial magnetic energy becomes heat in an ideal RL decay loop.
- Rapid current interruption can generate an emf far above the former supply voltage.
2.3 Follow charge and energy around an LC oscillation
A charged capacitor connected to an ideal inductor does more than discharge once. The capacitor's electric field builds current and magnetic energy. The inductor then keeps that current flowing, charging the capacitor with opposite polarity.
Write the oscillator equation
Choose a signed capacitor charge and define the signed current by . The loop equation becomes
This is the simple harmonic oscillator equation. For a capacitor initially at maximum positive charge and zero current,
The negative current during the first quarter cycle means the chosen plate's charge is decreasing. It does not indicate a negative current magnitude. The maximum magnitude is . Frequency and period are and .
For other starting conditions, use and . The initial charge and current together set the amplitude and phase. Knowing only the initial charge is insufficient if the inductor may already store energy. The unit product confirms that is a time.
Read one complete cycle
| Time | Capacitor charge | Current magnitude | Energy location |
|---|---|---|---|
| Zero | Maximum positive | Zero | Electric field |
| Quarter period | Zero | Maximum | Magnetic field |
| Half period | Maximum negative | Zero | Electric field |
| Three-quarter period | Zero | Maximum | Magnetic field |
| Full period | Maximum positive | Zero | Electric field |
The current is largest when the capacitor is empty. At that moment the inductor's field contains all the energy and sustains the motion of charge.
At any instant,
The two field energies exchange continuously. Each reaches its maximum twice during one charge period, because squaring removes the sign of charge or current.
Work from voltage to current amplitude
A 4.0 μF capacitor charged to 20 V is connected to a 25 mH inductor. First find . Then , giving and .
The peak current is . Energy provides a separate check: and gives the same amount. The first empty-capacitor instant occurs at about 0.50 ms; reversed full charge occurs at half a period.
Connect to a mass on a spring
Charge corresponds to displacement, current to velocity, inductance to mass, and reciprocal capacitance to spring stiffness. Capacitor energy plays the role of elastic energy; inductor energy plays the role of kinetic energy. Increasing the initial charge increases the energy and current amplitude but leaves the ideal circuit's frequency unchanged. Changing inductance or capacitance changes that frequency.
Key Takeaways
- Charge and current are one-quarter period out of step.
- An empty capacitor coincides with maximum current in an ideal LC cycle.
- Total electric plus magnetic energy stays constant.
- Frequency depends on L and C, while initial charge sets the amplitudes.
- Convert angular frequency to hertz by dividing by 2π.
- The mass–spring analogy maps charge to displacement and inductance to mass.
2.4 Recognize three forms of RLC decay
Add resistance to an LC loop and the resistor converts stored field energy to heat. The charge may oscillate with decreasing amplitude or return to equilibrium without oscillating, depending on the resistance.
Add the damping term
With , the source-free series circuit obeys
Its total field energy changes at the rate . The sign is never positive: the resistor removes energy even when charge and current change sign. In the mechanical analogy, resistance corresponds to the damping constant of a mass–spring system.
Compare resistance with the critical value
The critical resistance is .
| Resistance | Behavior |
|---|---|
| Underdamped: charge oscillates with a shrinking envelope. | |
| Critically damped: fastest nonoscillatory return for release from an initially charged capacitor with zero current. | |
| Overdamped: nonoscillatory return that is slower than at critical damping. |
For the underdamped case,
The envelope and the oscillation are separate features. The exponential controls how quickly peaks shrink; the cosine controls their spacing. Initial charge and current determine and . In particular, a damped cosine with zero phase does not in general have zero initial current, because its envelope is also changing.
Calculate a damped frequency and envelope
For , and , the undamped angular frequency is about 3162 rad/s. The envelope decay rate is . Thus , about 0.2% lower.
The charge envelope halves when , giving . The critical resistance is about 158 Ω, so 10 Ω is well inside the underdamped regime. As resistance rises toward 158 Ω, the damped frequency falls toward zero. Its decrease is small only when damping is light.
Keep amplitude, energy and driven motion distinct
For light damping, stored energy follows an approximately exponential envelope . Its exponent is twice the charge-amplitude exponent because energy depends on amplitude squared. The exact instantaneous loss remains .
Using in the charge envelope would therefore predict amplitude decay twice as fast as it actually occurs. A source-free circuit eventually loses its stored energy. A driven circuit can maintain oscillation by receiving energy from a source; its steady-state frequency is then the source frequency, not this free-decay frequency.
Key Takeaways
- Compare resistance with 2√(L/C) to identify the damping regime.
- The underdamped frequency is below the ideal LC frequency.
- Charge amplitude decays with rate R/(2L).
- For light damping, energy decays approximately twice as fast as amplitude.
- Critical damping gives the fastest nonoscillatory discharge from rest.
3Describe AC sources and single circuit elements with phasors
Sinusoidal sources require a description of both size and timing. Connect peak values to rms readings and resistor heating, then use the element laws to explain why current can lead or lag voltage. Phasors represent those phase relationships as rotating arrows. Their vector sums prepare you to combine several AC voltage drops without adding peaks that occur at different times.
3.1 Describe a sinusoidal supply and its rms value
An alternating source reverses polarity repeatedly. A rotating coil in a uniform magnetic field produces a sinusoidal emf, so sine waves give a useful description of generators and many AC circuits.
Describe the waveform
Write the source voltage as . Its amplitude is the largest voltage magnitude. The angular frequency is in radians per second; frequency counts cycles per second in hertz:
For a rotating coil, the emf amplitude is , where is the number of turns, the field and the coil area. Faster rotation raises both the frequency and the emf amplitude when the other quantities stay fixed.
A 50 Hz source has angular frequency about 314 rad/s and period 20 ms. A 60 Hz source has angular frequency about 377 rad/s and period about 16.7 ms. These are different descriptions of the same timing, not different types of oscillation.
Square before averaging
A sinusoidal current averages to zero over a full cycle, but a resistor still heats. Both positive and negative currents produce positive power . The useful measure is the root-mean-square current:
For , the cycle average of sine squared is one-half. Therefore
For example, the squared-current average is . Using , the cosine term averages to zero over a full period. The remaining gives the rms value after taking the square root.
The rms value is the DC value that would produce the same average heating in a fixed resistor. Taking the ordinary average first would erase the waveform's magnitude and wrongly predict zero heating.
The factor of square root of two belongs to a sinusoid. For a square wave alternating between equal positive and negative peaks, the squared voltage is constant, so its rms value equals its peak magnitude.
Use rms values for heating
For a resistor,
A 2000 W heating element supplied at 230 V rms has resistance . Its rms current is ; its peak current is about 12.3 A. Putting that peak into without the cycle-average factor would double the average power.
Interpret supply ratings
Ordinary household supply ratings are rms values. A 230 V sinusoidal supply peaks near 325 V; a 120 V supply peaks near 170 V. Many regions use 220–240 V at 50 Hz, while ordinary outlets in the United States and Canada use 120 V at 60 Hz. Japan has 50 Hz systems in the east and 60 Hz systems in the west. Voltage and frequency ratings both matter when moving equipment between supplies; matching the voltage alone does not establish that its frequency rating matches.
Key Takeaways
- Angular frequency, frequency and period obey ω = 2πf and T = 1/f.
- Rms means square, average, then take the square root.
- A sinusoidal rms value is its amplitude divided by √2.
- Rms current gives the same resistor heating as an equal DC current.
- The sinusoidal conversion factor does not apply to every waveform.
3.2 Find reactance and the current’s phase
A resistor, capacitor and inductor respond differently to the same sinusoidal voltage. Their element laws determine both current amplitude and the timing of the current relative to the voltage.
Start from each element law
For a resistor, at every instant. If , then . Current and voltage reach corresponding peaks together: they are in phase.
For a capacitor, and . Differentiating gives
Capacitor current leads voltage by 90°. It is largest when the voltage crosses zero and is changing fastest. Charge flows onto and off the plates, producing current in the connecting wires without charge crossing the dielectric.
For an inductor, the applied voltage is . Integrating the sinusoid in steady state gives
Inductor current lags voltage by 90°. The voltage is largest when the current changes fastest, not when the current is largest.
Compare the amplitude ratios
Reactance relates voltage and current amplitudes and is measured in ohms:
| Element | Reactance or resistance | Current relative to voltage |
|---|---|---|
| Resistor | In phase | |
| Inductor | Lags 90° | |
| Capacitor | Leads 90° |
For either reactive element, and . The instantaneous equation is false because the current and voltage are out of phase. Ideal reactive elements store and return energy, giving zero average power over a full cycle.
Calculate at a stated frequency
A 10 μF capacitor at 60 Hz has and . On 120 V rms, its rms current is about 0.452 A. At 50 Hz its reactance rises to about 318 Ω.
A 0.20 H inductor at 50 Hz has . On 230 V rms, its rms current is about 3.66 A. At 60 Hz its reactance rises to about 75.4 Ω. In both calculations, using frequency directly in place of angular frequency would miss the factor of .
Predict frequency effects
Increasing frequency increases inductive reactance but decreases capacitive reactance. An ideal inductor approaches a wire in the steady-DC limit; a charged ideal capacitor blocks steady DC. In loudspeaker crossovers, these tendencies help route low frequencies through an inductor and high frequencies through a capacitor. The memory aid “ELI the ICE man” puts voltage E before current I for L, and current I before voltage E for C.
Key Takeaways
- Resistor current and voltage are in phase.
- Capacitor current leads voltage by 90°; inductor current lags by 90°.
- Inductive reactance increases with frequency, while capacitive reactance decreases.
- Reactance relates amplitudes or rms values, not instantaneous values.
- Ideal inductors and capacitors return the energy they take during a cycle.
- Convert frequency to angular frequency before calculating reactance.
3.3 Add AC voltages with phasors
Adding two sinusoidal voltages requires their relative timing as well as their amplitudes. A phasor represents a sinusoid as a rotating arrow, turning the addition into a vector problem.
Read a rotating arrow
For , draw an arrow of length at angle from the horizontal. It rotates counterclockwise at angular speed . Its vertical projection is the instantaneous voltage.
At angle zero the voltage is zero and increasing. At 90° it is at its positive peak. The horizontal projection would give a cosine, so choosing it while writing a sine would shift the time reference by a quarter cycle.
Phasors at one frequency rotate together. Their relative angles stay fixed, so a diagram can show one instant without drawing the whole motion. A phasor farther ahead counterclockwise leads the other; one behind lags. Phasor arrows describe phase, not a physical rotation of charge around the circuit.
Use current as a reference
In a series circuit, choose the common current phasor along the horizontal axis at the pictured instant. The element voltages then point in these directions:
- Resistor voltage points along the current, with length .
- Inductor voltage points 90° ahead, with length .
- Capacitor voltage points 90° behind, with length .
The inductor and capacitor voltages oppose each other in the diagram. Their lengths subtract along that axis. The resistor contribution lies at right angles to this net reactive contribution.
Add a pair of sinusoids
Suppose and . Draw the first arrow horizontally and the second vertically upward. Their resultant has amplitude
Its angle ahead of the first is . Thus the sum is a 5.0 V sinusoid with that phase lead. Adding amplitudes to get 7.0 V would assume the two voltages peak together, which they do not.
The vector rule works because vertical projection distributes over vector addition. At every instant, the projection of the resultant equals the sum of the two individual projections. Kirchhoff's voltage rule therefore remains valid for instantaneous voltages and for phasors added as vectors.
For a general angle between two phasors of lengths and , the resultant magnitude satisfies . At zero separation it becomes ; at 180° it becomes . The perpendicular example is the middle case where the cosine term vanishes. Angle information therefore determines which addition rule applies.
Keep the diagram consistent
You can use rms lengths instead of peak lengths. Every arrow then shrinks by the same factor of square root of two, while all angles remain unchanged. Label which convention you use; mixing one rms arrow with one peak arrow changes the resultant incorrectly.
A fixed-frequency phasor diagram describes sinusoidal steady state. Just after connection, a circuit can also contain transient terms. Those terms decay in a resistive circuit, leaving the source-frequency response that the diagram represents.
Key Takeaways
- A phasor records sinusoidal amplitude and phase.
- With counterclockwise rotation and a sine convention, use the vertical projection.
- Add phasors as vectors; amplitudes add arithmetically only when in phase.
- Peak and rms phasor diagrams have the same angles.
- Phasors describe sinusoidal steady state after transients have decayed.
4Analyze series RLC circuits: impedance, resonance and power
A series resistor, inductor and capacitor share one current, but their voltage drops do not peak together. Combine their phasors to find impedance and phase, then vary the frequency to locate resonance and measure its width. Finally, connect the phase angle to average power and explain why a load can draw substantial current while absorbing less real power than the voltage–current product suggests.
4.1 Find current from series RLC impedance
In a series RLC circuit the same current passes through all three elements. Their voltage phasors have different directions, so the source voltage follows a vector sum. Impedance packages that sum into a voltage-to-current ratio.
Build the voltage triangle
Take current as the reference. Resistor voltage lies along it; inductor and capacitor voltages lie in opposite perpendicular directions. Using peak values,
Divide by current amplitude squared to obtain
The same relation holds with rms values. Impedance is measured in ohms, but its reactive part does not represent heat loss. Subtract the two reactances before squaring: adding them would ignore their opposite phases.
Interpret the phase sign
Write the source and current as and . Then
Positive phase means the voltage leads and the current lags: the circuit is inductive. Negative phase means the current leads: the circuit is capacitive. For positive resistance, choose the phase between −90° and +90°. Squaring the net reactance for impedance removes its sign, so return to the unsquared difference to decide the phase.
Work through a complete circuit
A 120 V rms, 60 Hz source drives , and in series.
- Convert the frequency: .
- Calculate reactances: and .
- Subtract: the net reactance is about −19.5 Ω.
- Find and .
- Find . The current leads the source voltage.
Keep unrounded values in the calculator until the final result. Use the angle mode appropriate to the answer you report.
Check component voltages
The rms component voltages are approximately 112 V across the resistor, 253 V across the inductor and 296 V across the capacitor. Each reactive voltage can exceed the source voltage because their phasors nearly cancel. The source is their vector sum:
Each voltage comes from the same current: , and . Factoring that current out of the voltage triangle recovers . Dividing its adjacent side by its hypotenuse gives , linking the geometry to the power factor.
For a series RL circuit, omit the capacitor contribution: . For a series RC circuit, omit the inductor contribution: . The omitted series element is replaced with a connecting wire.
Key Takeaways
- Series impedance combines resistance with the difference of inductive and capacitive reactance.
- Use I = V/Z with consistently peak or consistently rms values.
- Positive φ means lagging current; negative φ means leading current.
- Component voltages can exceed source voltage because their phasors cancel.
- Removing a reactive contribution from the formula assumes a closed connecting wire remains.
- Use the voltage triangle to check a calculated source voltage.
4.2 Find resonance and measure its sharpness
At a fixed source voltage, changing frequency changes the current in a series RLC circuit. Inductive reactance rises with frequency while capacitive reactance falls. At one frequency they cancel, making the current largest.
Locate the current peak
Set to find
At this resonance, , current is in phase with the source, and . Below resonance the circuit is capacitive and current leads. Above resonance it is inductive and current lags.
For a series circuit with fixed component values, resistance changes the peak's height and width but not the frequency of maximum current. This driven-current peak stays at the undamped LC frequency even though a freely decaying RLC oscillation has a lower damped frequency.
Describe width and quality factor
The quality factor and bandwidth are
Bandwidth is the difference between the two half-power frequencies. At either edge, average power is half its resonant value and current is of its resonant value. Half power does not mean half current, since resistor power depends on current squared.
At a half-power point, is half its resonant value. The impedance is therefore , which requires . The lower frequency uses net reactance and the upper frequency uses . Solving these two equations gives a separation exactly equal to . The two points are not generally equally spaced about on a linear frequency axis.
Smaller resistance produces a taller, narrower peak and a larger quality factor. A high quality factor selects a narrow frequency range; a low quality factor gives a broader response. Here the symbol means quality factor, not capacitor charge.
Calculate a resonance curve's features
Let , and , driven by 10 V rms. Then and . At resonance, rms current is 0.50 A and average power is 5.0 W.
The quality factor is about 7.9. Bandwidth is 400 rad/s, or about 64 Hz, with half-power frequencies near 2970 and 3370 rad/s. At twice the resonant angular frequency, the net reactance is about 237 Ω and the rms current falls to about 0.042 A.
Explain the large internal voltages
At resonance, . Each reactive voltage is times the source voltage. In the example, each is about 79 V rms even though the source is 10 V rms. Their opposing phasors cancel; neither component voltage is zero.
Changing capacitance lets a tuner move its resonant frequency. A 250 μH coil tuned to 1.0 MHz requires . In steady state, the circuit responds at the driving frequency throughout the tuning process. Resonance identifies where that response becomes strongest, not the only frequency at which the circuit can carry AC.
Key Takeaways
- Resonance occurs when inductive and capacitive reactances are equal.
- At resonance, series impedance is R and current is in phase with the source.
- Quality factor measures sharpness; bandwidth spans the half-power points.
- Half-power current is the maximum current divided by √2.
- Lower resistance narrows the peak without shifting the current-peak frequency.
- Resonance cancels reactive voltages in the sum, not across each component.
- A driven circuit oscillates at the source frequency.
4.3 Calculate real power and power factor
Voltage and current can each be large while a circuit absorbs little average power. Their relative phase matters because instantaneous power is their product. Energy sent into a reactive element during part of a cycle returns during another part.
Average the instantaneous product
For and , average over a full cycle. The result is
The product identity gives . The second cosine averages to zero over a complete cycle, leaving the first term. Instantaneous power can therefore vary even when average power is constant; for a reactive load it can become negative while energy flows back toward the source.
The factor is the power factor. In a series RLC circuit, , so the result reduces to . All average dissipation occurs in the resistance. Ideal inductors and capacitors have zero average power, although their instantaneous power changes sign.
Distinguish watts from volt-amperes
The product is apparent power, measured in volt-amperes. Real average power is measured in watts and equals apparent power times power factor.
| Load | Phase relationship | Power factor |
|---|---|---|
| Pure resistance | In phase | 1 |
| Ideal inductance | Current lags 90° | 0 |
| Ideal capacitance | Current leads 90° | 0 |
| Series RLC at resonance | In phase | 1 |
The cosine has the same value for positive and negative phase. A power factor is therefore described as lagging for an inductive load or leading for a capacitive load when that distinction matters.
Check power by two routes
For the series circuit supplied at 120 V rms with , and rms current about 2.24 A, the power factor is about 0.93. Thus . The resistor calculation gives the same result after rounding.
Using the source voltage in would instead give 288 W. That formula needs the voltage across the resistor, about 112 V in this circuit. At resonance the resistor voltage equals the source voltage, so the maximum power becomes .
Explain why correction reduces supply losses
For a fixed real load power, . A 1200 W motor on 230 V rms at power factor 0.80 draws about 6.52 A. At unity power factor the same power needs about 5.22 A. The larger current increases heating in supply wires according to .
A parallel capacitor can supply leading current locally to offset some of an inductive load's lagging current. The supply current then decreases while the load's real power stays the same. This is power factor correction: it reduces unnecessary current in the supply path. It does not remove the real energy required by the motor.
Key Takeaways
- Average AC power includes the power factor cos φ.
- Apparent power is measured in VA; real power is measured in W.
- Use the resistor voltage when calculating its power as V²/R.
- Leading and lagging identify phase signs that the cosine alone cannot show.
- Improving power factor reduces supply current for the same real load power.
5Explain transformers and AC power distribution
Changing magnetic flux allows a transformer to trade voltage for current while conserving energy in the ideal model. Use turns ratios to analyze a loaded transformer, then distinguish real heating losses from leakage flux. Follow the same ideas into power distribution: high voltage reduces line current and heating, while local conversion supplies useful voltages. Stored energy and high voltage also explain the main electrical hazards.
5.1 Use transformer ratios and identify real losses
A transformer transfers energy between coils through changing magnetic flux. Its primary receives AC, and the common core guides flux through the secondary. Different turn counts give different voltages without requiring a direct electrical connection between the windings.
Derive the turns ratio
In the ideal model, the same flux threads every turn of both coils. With matching voltage reference directions, each winding voltage is its turn count times the flux-change rate:
Taking the ratio gives for voltage magnitudes, whether peak or rms. More secondary turns produce a step-up transformer; fewer produce a step-down transformer.
For a resistive load and an ideal transformer, input and output power are equal:
Voltage and current ratios run in opposite directions. Raising voltage reduces current for the same transferred power. The transformer does not multiply energy.
Calculate a loaded transformer
A primary with 1150 turns receives 230 V rms. Its 60-turn secondary supplies a resistive load drawing 2.0 A. The secondary voltage is . Output power is 24 W, so primary current is .
The load determines the current demand. In the ideal model, an open secondary draws no load current and no real input power. A real unloaded transformer still needs a small magnetizing current and supplies its core losses. When the load draws more current, the primary draws more power to support it.
Reflect a resistance to the primary
A load resistance appears to the source as
This follows by dividing the transformed voltage by the oppositely transformed current. A turns ratio makes an 8.0 Ω secondary load appear as 800 Ω at the primary. The squared ratio explains how transformers match a source to a load.
Separate dissipative losses from imperfect coupling
Real windings dissipate energy through their resistance. Changing core flux drives eddy currents and repeatedly magnetizes the core, producing hysteresis losses. Thin insulated core laminations reduce eddy-current paths. These losses make output real power smaller than input real power.
Some flux fails to link both windings. This leakage flux acts like an additional series inductance and contributes to voltage drop under load; leakage itself is not a dissipative loss. Large power transformers can exceed 99% efficiency, while small devices generally have lower efficiency.
A steady DC current produces constant flux after switching transients end, so it gives no continuing secondary emf. A transformer therefore needs changing flux to sustain its output. The brief pulses at switching do not provide continuous voltage conversion on steady DC.
Key Takeaways
- Transformers use mutual induction through a shared changing flux.
- Voltage follows the turns ratio; current follows the inverse ratio.
- Ideal power conservation applies to a resistively loaded transformer.
- Reflected resistance changes by the square of the primary-to-secondary turns ratio.
- Winding resistance, eddy currents and hysteresis dissipate energy.
- Leakage flux changes coupling and voltage regulation without itself dissipating energy.
- Steady DC cannot sustain transformer output.
5.2 Explain transmission losses and electrical hazards
Electric power often travels far from where it is generated. The wires have resistance, so some transmitted energy becomes heat. Transformers make it possible to change voltage between efficient long-distance transmission and local delivery.
Calculate line heating from current
If the total line resistance is , the heating loss is
For a fixed receiving-end power and receiving-end rms voltage at unity power factor, . Thus
Increasing voltage by a factor of 20 reduces current by 20 and heating loss by 400. The comparison holds delivered power and line resistance fixed.
Suppose 10 MW is delivered through lines with total resistance 5.0 Ω. At 20 kV the current is 500 A and the loss is 1.25 MW, or 12.5% of delivered power. At 400 kV the current is 25 A and the loss is 3125 W, about 0.03% of delivered power. The source must provide delivered power plus these losses.
Use the voltage across the right component
The transmission voltage is mostly across the receiving load. It is not the voltage across the resistance of the wires. The line voltage drop is : 2500 V in the first case and 125 V in the second.
You can calculate heating as , but inserting the full transmission voltage into that expression would describe an entirely different circuit. First identify where each voltage is measured.
Follow power through the grid
Large generators commonly supply about 10–25 kV. Step-up transformers raise voltage to hundreds of kilovolts for transmission. Substations reduce it for distribution, and local transformers reduce it again for users. Typical household supplies include about 230 V and about 120 V.
Frequency is standardized within each interconnected AC system, commonly at 50 or 60 Hz. Connected synchronous generators stay in step with that frequency. A country can contain separate frequency systems: Japan's eastern and western regions use 50 and 60 Hz, linked by frequency-converter stations.
High-voltage DC is also used for long routes and undersea cables. Converter stations connect these links to AC systems. A conventional transformer cannot change a steady DC voltage, so voltage conversion in a DC link needs conversion equipment.
Recognize stored-energy and high-voltage hazards
Household voltages can drive lethal current through the body, and transmission voltages can arc across an air gap. Use low-voltage supplies for experiments and stay clear of power lines and substations. Never interrupt a large coil's current by hand. Capacitors can retain charge after disconnection, and resonant circuits can build component voltages far above the source voltage. Disconnecting a source alone does not establish that a circuit is safe to touch.
Key Takeaways
- Line heating is I²R for the resistance of the complete current path.
- At fixed delivered power and unity power factor, line loss falls as voltage squared increases.
- The line voltage drop differs from the voltage delivered to the load.
- Transformers raise transmission voltage and lower it again for local use.
- AC systems can have different standard frequencies and need converters to exchange power.
- Stored energy and arcing remain hazards beyond the supply’s stated voltage.
Inductance and AC Circuits examples
1From linked flux to stored magnetic energy
14 steps
- 1IntroductionWhat a changing current does
A coil carrying current produces magnetic flux. If that current changes, the flux can induce an emf in the same coil or in a neighboring one.
Follow the chain from field to flux linkage to induced emf. Then use the work needed to build the current to find magnetic energy. The central distinction is between the current that creates a field and the rate of current change that creates the induced emf.
- 2ExplanationCount every linked turn
For two linear coils, define mutual inductance by . The flux is through one receiving turn; multiplying by counts all its turns.
The induced emf is . A steady current can create substantial flux without creating an emf. The minus sign tells you to oppose the flux change when choosing the induced direction.
- 3ExampleFind the field and receiving area
A long solenoid has 1000 turns over 0.50 m. A coaxial 200-turn coil of radius 1.5 cm sits near its center.
Imagine current in the long solenoid, whose field is . One inner turn receives flux . Use the inner turn's own area: magnetic field outside that loop does not contribute to its flux.
- 4ExampleConvert flux linkage into coupling
Multiply the one-turn flux by 200 and divide by the imagined current. The current cancels:
For a source current increasing at 50 A/s, calculate the emf magnitude:
Reciprocity gives the same mutual inductance when the coils exchange source and receiver roles.
- 5ChallengeChange the rate, not the current
A pair of coils has mutual inductance 6.0 mH. The source current rises from 1.0 A to 4.0 A in 0.020 s. What emf magnitude is induced in the other coil?
---reveal---
The rate is . Therefore . Using the final current alone would not determine an emf; the time interval is essential.
- 6ExplanationLink a coil to its own field
Self-inductance uses the coil's own flux: . A long solenoid has field proportional to its turn count, and each of its turns links that field.
Thus . The squared turn count has two origins: producing a stronger field and linking more turns. A toroid instead needs a radial field integral because its field decreases with radius.
- 7Key InsightKeep voltage signs and current continuity together
Crossing an inductor along its current gives potential change . This is a drop during current growth and a rise during decay.
With finite voltage, current cannot jump: a jump would require an infinite derivative. Yet the voltage can change abruptly when a switch moves. Preserve the initial current first, then let the new circuit determine its rate of change.
- 8ChallengeRead a decaying current
A 0.15 H coil carries positive current that is falling at 40 A/s. Traversing the ideal inductor in that current's direction, do you encounter a potential rise or drop, and of what size?
---reveal---
The change is : a rise. The coil is supplying energy to sustain the existing current while its magnetic field decreases.
- 9ExplanationIntegrate the work needed to build current
Power entering an ideal inductor is . During a small current increase, the stored energy changes by .
Integrate from zero current:
This is magnetic storage. When current decreases, the inductor can return the energy. Reversing current at unchanged magnitude leaves this squared-current energy unchanged.
- 10ExampleCheck stored energy in the field
The 0.395 mH solenoid carrying 2.0 A stores .
Its field is about 5.03 mT. In air, . Multiplying by its field-filled volume, about , gives the same energy. The circuit and field calculations count the same stored work.
- 11ConnectionUse field energy when flux is awkward
For a thin-conductor coaxial cable, the magnetic field varies as between the conductors. A shell of thickness has volume .
Integrating over those shells gives . Compare this with to obtain without a flux-linkage calculation.
- 12ChallengeSeparate voltage from stored energy
An ideal 0.60 H inductor carries a steady 2.0 A. What are its voltage and stored energy at that instant?
---reveal---
Its voltage is zero because the current derivative is zero. Its energy is . Zero voltage means energy is not changing at that instant; it does not mean that the magnetic field contains no energy.
- 13ChallengePredict two effects of rewinding
A long solenoid is rewound with twice its original turns, keeping length and area fixed. It then carries the same current as before. How do its back-emf magnitude at a given current-change rate and its stored energy change?
---reveal---
Both become four times as large. The new inductance is four times larger, and both and scale with inductance under these fixed conditions.
- 14RecapChoose the quantity that matches the question
For coupling or self-inductance, start with field and flux linkage. For induced emf, use the current-change rate and Lenz's law. For stored energy, use current squared or integrate field energy density.
These choices separate three quantities that can behave differently: a steady current can produce flux and store energy while producing no self-induced voltage.
2Follow a circuit through switching and oscillation
18 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionStart with the current already present
- 2ExplanationWrite the growth equation
- 3ExampleCalculate a growing current
- 4ChallengeFind the wait for a chosen fraction
- 5TipRebuild the network at each limit
- 6ExplanationLet the field drive the decay
- 7Key InsightWatch energy fall faster than current
- 8ChallengeUse a new decay resistance
- 9ExplanationFollow the first quarter cycle
- 10ExplanationUse the charge equation
- 11ExampleFind the energy and maximum current
- 12ChallengeCheck what changes the frequency
- 13AnalogyMatch the oscillator to a spring
- 14ExplanationLet resistance drain the oscillation
- 15ExampleSeparate the envelope from the frequency
- 16ChallengeChoose the fastest nonoscillatory case
- 17ChallengeAccount for energy at the first charge peak
- 18RecapMatch each time response to its cause
3Read AC size, timing and phasors
13 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionTrack size and timing separately
- 2ExplanationRead the sine wave’s parameters
- 3ExplanationAverage the square for heating
- 4ExampleMove between a rating and a peak
- 5ChallengeRead a voltage equation
- 6ExplanationDifferentiate capacitor voltage
- 7ConnectionCompare resistance and inductance
- 8ChallengePredict a frequency change
- 9ExplanationTurn phase into an arrow angle
- 10ExampleDraw two perpendicular contributions
- 11ExampleFind the sum’s timing
- 12ChallengeCombine opposing reactive arrows
- 13RecapKeep a consistent AC description
4Solve a series AC circuit and vary its frequency
16 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionOne current, three voltage directions
- 2ExplanationBuild impedance from a right triangle
- 3ExampleCalculate reactances first
- 4ExampleFind current and phase
- 5ChallengeInfer the missing reactance
- 6Key InsightCheck voltages as vectors
- 7ExplanationTune the reactive sum to zero
- 8ExplanationMeasure the peak’s width
- 9ExampleCalculate a resonator’s internal voltage
- 10ChallengeChange only resistance
- 11ExplanationInclude phase when finding real power
- 12ExampleCheck power with the resistor
- 13ConnectionReduce current without reducing load power
- 14ChallengeCompare line heating before and after correction
- 15ChallengeFind real power from phase and impedance
- 16RecapUse phase to connect current, tuning and power
5Transform voltage and account for transmission losses
12 steps
Save this lesson to follow every Walkthrough step by step.
- 1IntroductionTrade voltage for current
- 2ExplanationShare a flux-change rate
- 3ExampleFind the secondary voltage
- 4ExampleLet the load set the current
- 5ChallengeReflect a resistance
- 6Key InsightSeparate heat loss from leakage
- 7ExampleCalculate the low-voltage transmission case
- 8ExampleRaise voltage while holding delivered power fixed
- 9ChallengeUse the line drop in a heating calculation
- 10ConnectionConnect systems with different supplies
- 11ChallengeAccount for the source’s extra power
- 12RecapFollow power and label each voltage
Inductance and AC Circuits practice questions
Set 1: Switching paths, stored energy and phase10 Practice Questions
Question 1 of 10
Show answerHide answer
Question 2 of 10
Show answerHide answer
Question 3 of 10
Show answerHide answer
Question 4 of 10
Show answerHide answer
Question 5 of 10
Show answerHide answer
Question 6 of 10
Show answerHide answer
Question 7 of 10
Show answerHide answer
Question 8 of 10
Show answerHide answer
Question 9 of 10
Show answerHide answer
Question 10 of 10
Show answerHide answer
Set 2: Diagnose and combine AC circuit behavior10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 3: Series AC circuits and transformers10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Set 4: Inductance, switching and AC foundations10 Practice Questions
Save this lesson to see every answer and practice every set.
Question 1 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 2 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 3 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 4 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 5 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 6 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 7 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 8 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 9 of 10
Show answerHide answer
Save this lesson to see this answer.
Question 10 of 10
Show answerHide answer
Save this lesson to see this answer.
Stuck on your own question? Homework Help
Key Terms
A
Alternating current
Amplitude envelope
Angular frequency
Apparent power
Average real power
B
Back emf
Bandwidth
C
Capacitive reactance
Charge amplitude
Coaxial cable
Coupling coefficient
Critical damping
Current continuity
Current half-time
D
Damped angular frequency
Decay path
E
Eddy currents
Energy exchange
F
Field-energy integral
Flux linkage
Frequency
Frequency converter
H
Half-power frequency
Henry
Hysteresis loss
I
Impedance
In phase
Inductive reactance
Inductive time constant
Inductive voltage spike
Inductor
Initial condition
L
Lagging current
LC oscillation
Leading current
Leakage flux
Line voltage drop
Long solenoid
M
Magnetic energy density
Magnetic field energy
Mutual inductance
N
Natural angular frequency
Net reactance
O
Oscillation period
Overdamping
P
Peak value
Phase
Phase angle
Phasor
Phasor sum
Power factor
Power factor correction
Primary winding
Q
Quality factor
R
Reciprocity of mutual inductance
Reference phasor
Reflected resistance
Relative permeability
Resonance
RL decay
RL growth
Rms value
S
Secondary winding
Self-inductance
Steady state
Step-down transformer
Step-up transformer
T
Toroid
Transformer
Transmission-line loss
Turns ratio
U
Underdamping
V
Voltage magnification
Voltage triangle
About this lesson
Make your own Study Materials
Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.