Inductance and AC Circuits

Learn how a changing current induces an emf in its own coil and in nearby coils, and how inductors store energy in their magnetic fields. Follow current as it grows and decays in RL circuits, and as charge and energy oscillate in LC and RLC circuits. Then describe alternating current with rms values and phasors, use reactance and impedance to analyze series RLC circuits, explain resonance and the power factor, and see how transformers make high-voltage power transmission efficient.

IntermediateLesson 9 of 10 in Physics 2 – Electricity and Magnetism Course

What you will learn

  1. Explain how a changing current induces an emf in a neighboring coil and in the coil itself, calculate mutual and self-inductance for simple coil shapes, and find the energy stored in an inductor's magnetic field.
    • Calculate the mutual inductance of two coils
      Define mutual inductance, use it to find the emf a changing current induces in a nearby coil, and calculate it for coaxial solenoids.
    • Find the self-inductance of a coil and the emf it induces in itself
      Define self-inductance, use the back emf of an inductor in circuit equations, and calculate the inductance of a solenoid and a toroid.
    • Calculate the energy stored in an inductor and its magnetic field
      Derive the energy stored in an inductor, connect it to the energy density of the magnetic field, and use field energy to find inductance.
  2. Apply Kirchhoff's loop rule to circuits with inductors to find how current grows and decays in RL circuits, and describe how charge, current and energy oscillate in LC and RLC circuits.
    • Describe how current grows in an RL circuit
      Set up and solve the loop equation for a resistor and inductor connected to a battery, interpret the time constant and find currents just after switching and long afterward.
    • Describe how current decays in an RL circuit and where its energy goes
      Find the decaying current when the source is removed, calculate the energy dissipated, and explain the large emfs and sparks caused by breaking an inductive circuit.
    • Explain the oscillations of an LC circuit
      Describe how energy moves between a capacitor and an inductor, solve the LC equation for charge and current, and use the mass-on-a-spring analogy.
    • Describe damped oscillations in an RLC circuit
      Add resistance to the LC circuit, and distinguish underdamped, critically damped and overdamped behavior using the damped oscillation formulas.
  3. Describe sinusoidal voltages and currents by amplitude, frequency, phase and rms value, find how a resistor, an inductor and a capacitor each respond to an AC source, and represent these relationships with phasor diagrams.
    • Describe AC voltages and currents and their rms values
      Describe a sinusoidal source by amplitude, frequency and period, explain rms values and use them to calculate average power in a resistor.
    • Relate current and voltage for a resistor, a capacitor and an inductor
      Find the current through each element driven by an AC source, define capacitive and inductive reactance, and explain the phase difference and the frequency dependence of each element.
    • Represent AC quantities with phasors
      Use rotating phasors to show amplitude and phase, read instantaneous values from them, and add sinusoids of the same frequency as vectors.
  4. Use phasor diagrams to find the impedance, current and phase angle of a series RLC circuit driven by an AC source, explain resonance and its sharpness, and calculate average power and power factor.
    • Find the impedance, current and phase angle of a series RLC circuit
      Combine the phasors of a series resistor, inductor and capacitor to find the impedance, the current, the phase angle and the voltage across each element.
    • Explain resonance in a driven series RLC circuit
      Find the resonance frequency of a series RLC circuit, describe how the current depends on driving frequency, and use the quality factor and bandwidth to describe the sharpness of resonance.
    • Calculate average power and power factor in AC circuits
      Find the average power a source delivers to an AC circuit, explain the power factor and why a low power factor costs energy in wiring.
  5. Calculate voltages, currents and power in ideal transformers, describe the losses in real ones, and explain why electric power is transmitted at high voltage and how to stay safe with AC.
    • Calculate voltages and currents in an ideal transformer
      Explain how a transformer works by mutual induction, apply the turns ratio to voltages and currents, and describe the losses in real transformers.
    • Explain high-voltage power transmission and AC safety
      Calculate the power lost in transmission lines, explain why transformers make high-voltage transmission efficient, and state the main safety rules for AC and inductive circuits.

Inductance and AC Circuits study guide

5 chapters

1

Describe inductance and the energy stored in magnetic fields

A changing current links circuit behavior to magnetic flux. Learn how coil geometry sets mutual and self-inductance, how the induced emf opposes a current change, and how the field stores the work done by a source. Calculating both flux linkage and field energy gives two routes to inductance, including arrangements where the magnetic field varies across the space between conductors.

A current in one coil produces a magnetic field through nearby coils. A changing current changes that flux and induces an emf. Mutual inductance measures the strength of this connection; the second coil does not need a wire connecting it to the first.

From flux to induced emf

Let Φ21 be the flux through one turn of coil 2 caused by current I1. With N2 turns, its flux linkage is N2Φ21. For a linear magnetic response,

M=N2Φ21I1,ε2=−MdI1dt.

The minus sign expresses Lenz's law. If the second coil forms a closed circuit, its induced current opposes the change in the linked flux. If the first current decreases, the induced field supports the original field. A large steady current produces flux but no induced emf.

Inductance is measured in henries: 1 H=1 Wb/A=1 V⋅s/A=1 Ω⋅s. Mutual inductance depends on turns, size, spacing and orientation. A magnetic core strengthens the coupling; with iron, the response can also depend on current.

Choose the easier field calculation

For the same two coils, M12=M21. You can calculate the field from either coil, then find its flux through the other. Choose the direction that makes the field simplest.

A long solenoid has 1000 turns over 0.50 m. A coaxial 200-turn coil of radius 1.5 cm sits near its center. Imagine current I1 in the long solenoid. Its field at the inner coil is B1=μ0N1I1/ℓ. Each inner turn encloses area A2=π(0.015)2, so

N2Φ21=N2B1A2,M=μ0N1N2A2ℓ.

Substitution gives M≈3.55×10−4 H=0.355 mH. At a current increase of 50 A/s, the emf magnitude is M∣dI1/dt∣≈17.8 mV. Use the inner coil's area: it is the area enclosed by each receiving turn. Using the outer area would count field that never passes through that turn.

The general method is to find the field, integrate it over one receiving turn, multiply by the receiving turn count, and divide by the source current. Distinguish flux through one turn from flux linkage through the whole coil. Omitting the receiving turn count loses a factor of 200 in this example.

Measure how much flux is shared

The coupling coefficient describes the connection relative to the coils' own inductances:

M=kL1L2,0≤k≤1.

Coils on a common closed iron core can have coupling close to 1. Separating coils or turning their axes toward perpendicular reduces the shared flux. Wireless chargers use strong mutual coupling to transfer energy; circuit designers reduce unwanted coupling to limit interference.

Key Takeaways

  • Mutual inductance converts a current-change rate in one coil into an emf in another.
  • Find flux through one receiving turn, then multiply by its number of turns.
  • The same mutual inductance applies in both directions.
  • Lenz’s law fixes the induced direction by opposing the flux change.
  • Geometry and magnetic material determine coupling strength.

1.2 Find a coil’s self-inductance and back emf

A coil's field passes through its own turns. When its current changes, that linked flux changes too, producing a self-induced emf. An inductor is a component designed to make this effect significant.

What an inductor opposes

For constant inductance,

L=NΦBI,εL=−LdIdt.

The emf opposes a change in current. During an increase it acts against the current; during a decrease it acts to sustain it. A steady current gives zero induced emf, even when the current and stored magnetic energy are large.

For Kirchhoff's loop rule, crossing the inductor in the direction of the current gives a potential change −L dI/dt. This is a drop during growth and a rise during decay. The passive voltage across the inductor is vL=L dI/dt; the self-induced emf has the opposite sign. A real coil also has wire resistance, modeled in series with its ideal inductance.

A finite emf cannot make the current jump. Such a jump would require an infinite rate of change. This continuity rule will determine the current immediately after a switch moves.

Derive the solenoid formula

For a long air-core solenoid, B=μ0NI/ℓ. Multiply the field by its area for one turn's flux, then multiply by the number of turns again:

NΦB=N(μ0NIℓA),L=μ0N2Aℓ.

One factor of N comes from producing the field; the other comes from linking all the turns. Doubling the turns while holding length and area fixed therefore multiplies inductance by four. With turns per length n=N/ℓ, the same result is L=μ0n2Aℓ.

For 500 turns over 0.25 m with radius 1.0 cm, first convert the radius: A=π(0.010)2≈3.14×10−4 m2. Then L≈3.95×10−4 H=0.395 mH. A rise from zero to 2.0 A in 4.0 ms gives dI/dt=500 A/s and an emf magnitude of about 0.197 V.

Integrate a toroid's nonuniform field

Inside a toroid, B(r)=μ0NI/(2πr). For rectangular cross-section height h, a radial strip has area h dr. Thus

ΦB=∫R1R2μ0NIh2πr dr,L=μ0N2h2πln⁡R2R1.

For 1000 turns, height 2.0 cm, inner radius 5.0 cm and outer radius 8.0 cm, this gives about 1.88 mH. Using one uniform field across a wide toroid would miss its radial variation.

Evaluate the toroid in stages: μ0/(2π)=2.0×10−7 H/m, N2=106, and h=0.020 m. These factors give 0.0040 H before the logarithm. Multiplying by ln⁡(0.080/0.050)≈0.470 gives 0.00188 H. The radius ratio has no units, as the argument of a logarithm must.

A ferromagnetic core can raise inductance by hundreds or thousands through its relative permeability. The simple multiplication is approximate because the core's magnetic response can change with current. The relation V=LI never replaces the derivative law: it would confuse inductance with resistance and even gives the wrong units for voltage.

Key Takeaways

  • Self-induced emf opposes changes in current and vanishes for steady current.
  • Current through an inductor remains continuous when emfs are finite.
  • A long solenoid has inductance proportional to turns squared.
  • A toroid requires a flux integral because its field varies with radius.
  • Keep the loop-rule sign consistent with the chosen crossing direction.
  • A real coil combines inductance with wire resistance.

1.3 Find energy in an inductor and in its field

Building a current requires the source to work against the inductor's back emf. That work becomes magnetic field energy. When the current later decreases, the field can return energy to the circuit.

Integrate the power

For an ideal inductor, the power entering its field is P=vLI=LI dI/dt. The small energy increase is therefore dU=LI dI. Integrating from zero current gives

UL=∫0ILI′ dI′=12LI2.

Reversing the current leaves the energy unchanged; doubling its magnitude quadruples the energy. At steady current the field still stores energy even though no power enters an ideal inductor. Zero instantaneous power means the stored amount is no longer changing.

Compare the storage laws:

SystemStored energyStorage mechanism
InductorLI2/2Magnetic field
CapacitorCV2/2=q2/(2C)Electric field
Moving massmv2/2Kinetic energy

Inductance plays a role like mass, while current plays a role like velocity. This analogy helps explain why current persists after a source is removed.

Locate the energy in space

In vacuum, and approximately in air, magnetic energy per unit volume is

uB=B22μ0,U=∫uB dV.

For a nearly uniform solenoid field, multiply energy density by the field-filled volume Aℓ. In the 500-turn solenoid of length 0.25 m and radius 1.0 cm carrying 2.0 A, the field is about 5.03 mT. Its energy density is about 10.1 J/m³. The volume is about 7.85×10−5 m3, so the energy is about 7.9×10−4 J.

The circuit calculation gives the same answer: UL=12(3.95×10−4)(2.0)2≈7.9×10−4 J. More generally, inserting B=μ0nI into the field integral gives U=12(μ0n2Aℓ)I2, recovering the solenoid inductance.

Energy density and energy have different units. In B2/(2μ0), the units reduce to joules per cubic meter. Multiplying by a volume gives joules; integrating over a length alone would not. For a solenoid, the field is approximately uniform, but for the coaxial field below each radial region contributes a different density.

Use field energy to find inductance

If the field is easier to calculate than flux linkage, find its energy first and use L=2U/I2. Consider a coaxial cable with thin conductors at radii a and b. Equal outward and return currents confine its field between the conductors:

B(r)=μ0I2πr.

A cylindrical shell of length ℓ has volume dV=2πrℓ dr. Combining the field and volume gives

U=∫abμ0I2ℓ4πr dr=μ0I2ℓ4πln⁡ba.

Comparing with LI2/2 gives L/ℓ=μ0ln⁡(b/a)/(2π). The logarithm comes from integrating a nonuniform field; multiplying by one field value and the entire volume would be incorrect. This result describes the field between thin conductors, so it does not add magnetic energy inside solid conductors.

Key Takeaways

  • An ideal inductor stores magnetic energy equal to one-half inductance times current squared.
  • In air or vacuum, integrate magnetic energy density over the field region.
  • Field energy can determine inductance through the relation L = 2U/I².
  • A steady current can store energy while the inductor voltage is zero.
2

Analyze RL circuits and LC oscillations

Switching a circuit reveals the effect of stored magnetic energy over time. Start with current growth and decay in RL loops, then follow energy between a capacitor and an inductor. Adding resistance connects these electrical oscillations to damped mechanical motion. Initial conditions and the path left by a switch determine which equation describes each stage.

2.1 Follow current as an RL circuit switches on

Connect a battery, resistor and inductor in series. The battery starts building current, but the inductor's back emf prevents an immediate jump. As the current approaches its final value, the back emf fades.

Build and solve the loop equation

Close the switch at t=0 with zero initial current. Going around the loop in the current direction gives

ε−IR−LdIdt=0.

Initially the resistor drop is zero, so dI/dt=ε/L. Later, the growing resistor drop leaves less voltage to change the current. Rearranging and separating variables gives

dIε/R−I=RL dt.

Integration with I(0)=0 yields

I(t)=εR(1−e−t/τ),τ=LR.

The integration produces −ln⁡(1−IRε)=RtL. Exponentiating gives the shrinking fractional gap 1−IR/ε=e−Rt/L. This is why the growth formula contains one minus the exponential: the exponential tracks what is still missing from the final current.

The time constant is in seconds because a henry is an ohm-second. After one time constant the current reaches about 63.2% of its final value; after five it exceeds 99.3%. Larger inductance slows the rise. Smaller resistance also lengthens the time constant, while raising the final current.

Calculate current and voltage together

For a 12 V source, 6.0 Ω resistor and 0.30 H inductor, τ=0.050 s and I∞=2.0 A. The initial slope is 40 A/s. At 0.050 s, I=2.0(1−e−1)≈1.26 A; at 0.10 s it is about 1.73 A.

The voltages divide as

vR=ε(1−e−t/τ),vL=εe−t/τ.

At one time constant these are about 7.59 V and 4.41 V. Their sum remains 12 V. Long afterward the ideal inductor has zero voltage drop, so the resistor alone sets the final current.

To find a waiting time, isolate the exponential before taking a logarithm:

t=−τln⁡(1−II∞).

Reaching 90% takes τln⁡10≈0.115 s in this circuit. An exponential approaches its limiting value; it does not reach it exactly at one time constant.

Use switching limits in a branched circuit

A 12 V battery feeds a 4.0 Ω resistor, followed by two parallel branches: an 8.0 Ω resistor and an ideal inductor. The inductor initially carries no current.

Immediately after closing the switch, the inductor branch carries zero current. The two resistors therefore carry 12/(4.0+8.0)=1.0 A. Long afterward the inductor acts as a wire across the 8.0 Ω resistor. That resistor has zero voltage and zero current; the battery and inductor carry 12/4.0=3.0 A.

The open-branch picture applies initially because this inductor started with zero current. If an inductor was already carrying current before switching, preserve that initial current instead. Check the actual initial condition before replacing a branch with a limiting model.

Key Takeaways

  • Write the loop equation before choosing an exponential solution.
  • The RL time constant is L/R; the final current is ε/R.
  • An initially unenergized inductor starts with zero current and a nonzero current slope.
  • After a long time on DC, an ideal inductor acts as a wire.
  • In a branched circuit, recalculate the resistor network at each switching limit.

2.2 Follow current and energy after the source is removed

Removing a battery does not remove the magnetic energy already in an inductor. If a closed resistive path remains, the inductor drives current through it while the field loses energy.

Solve the decay equation

Let the initial current be I0 and the resistance of the remaining loop be R. Kirchhoff's rule gives

−IR−LdIdt=0,I(t)=I0e−t/τ,τ=L/R.

The current keeps its original direction while decreasing. Since dI/dt<0, the inductor supplies a potential rise along that current. Its polarity reverses compared with the growth stage; its current does not reverse.

For I0=2.0 A, L=0.30 H and R=6.0 Ω, the time constant is 0.050 s. After 0.10 s, I=2.0e−2≈0.27 A. Solving I/I0=1/2 gives a half-time of τln⁡2≈0.035 s. After five time constants, less than 1% of the initial current remains.

Track the energy separately

The initial energy is U0=LI02/2. Because energy depends on current squared,

U(t)=U0e−2t/τ.

Energy decreases faster than current. When the current has halved, only one-quarter of the initial energy remains. The resistor receives the difference as heat. Integrating its power confirms the total:

∫0∞I02Re−2t/τ dt=I02Rτ2=12LI02.

The example releases 0.60 J into the resistor. A continuing current after disconnection does not require a continuing battery supply; its energy comes from the field.

Identify the new loop

A 12 V battery and 4.0 Ω resistor feed an 8.0 Ω resistor in parallel with a 0.40 H ideal inductor. After a long time, the inductor carries 3.0 A and the 8.0 Ω resistor carries no current.

Now open the battery branch while leaving the inductor and 8.0 Ω resistor connected. The inductor current is still 3.0 A at the switching instant. It returns through the 8.0 Ω resistor, so τ=0.40/8.0=0.050 s. The initial resistor voltage magnitude is 24 V. Its current runs opposite to its direction during the earlier growth stage. The 4.0 Ω resistor is no longer part of the decay loop.

Understand an interrupted path

If the current is forced to fall quickly, the emf can be large. Reducing 2.0 A to zero in 1.0 ms in a 0.30 H coil gives an average magnitude L∣ΔI/Δt∣=600 V. This can produce a spark across switch contacts. A designed decay path limits the voltage by giving the stored energy somewhere to go. Ignition coils use rapid interruption to produce a large voltage deliberately.

Key Takeaways

  • Decay current keeps its direction while the inductor voltage reverses.
  • Use the resistance in the closed path that remains after switching.
  • Current falls as exp(−t/τ), while magnetic energy falls as exp(−2t/τ).
  • The initial magnetic energy becomes heat in an ideal RL decay loop.
  • Rapid current interruption can generate an emf far above the former supply voltage.

2.3 Follow charge and energy around an LC oscillation

A charged capacitor connected to an ideal inductor does more than discharge once. The capacitor's electric field builds current and magnetic energy. The inductor then keeps that current flowing, charging the capacitor with opposite polarity.

Write the oscillator equation

Choose a signed capacitor charge q and define the signed current by i=dq/dt. The loop equation becomes

Ld2qdt2+qC=0.

This is the simple harmonic oscillator equation. For a capacitor initially at maximum positive charge Q and zero current,

q(t)=Qcos⁡ω0t,i(t)=−ω0Qsin⁡ω0t,ω0=1LC.

The negative current during the first quarter cycle means the chosen plate's charge is decreasing. It does not indicate a negative current magnitude. The maximum magnitude is Imax⁡=ω0Q. Frequency and period are f0=ω0/(2π) and T=2πLC.

For other starting conditions, use q=Qcos⁡(ω0t+ϕ) and i=−ω0Qsin⁡(ω0t+ϕ). The initial charge and current together set the amplitude and phase. Knowing only the initial charge is insufficient if the inductor may already store energy. The unit product H⋅F=s2 confirms that LC is a time.

Read one complete cycle
TimeCapacitor chargeCurrent magnitudeEnergy location
ZeroMaximum positiveZeroElectric field
Quarter periodZeroMaximumMagnetic field
Half periodMaximum negativeZeroElectric field
Three-quarter periodZeroMaximumMagnetic field
Full periodMaximum positiveZeroElectric field

The current is largest when the capacitor is empty. At that moment the inductor's field contains all the energy and sustains the motion of charge.

At any instant,

q22C+12Li2=Q22C=12LImax⁡2.

The two field energies exchange continuously. Each reaches its maximum twice during one charge period, because squaring removes the sign of charge or current.

Work from voltage to current amplitude

A 4.0 μF capacitor charged to 20 V is connected to a 25 mH inductor. First find Q=CV=80 μC. Then ω0≈3162 rad/s, giving f0≈503 Hz and T≈1.99 ms.

The peak current is Imax⁡=ω0Q≈0.253 A. Energy provides a separate check: CV2/2=8.0×10−4 J and LImax⁡2/2 gives the same amount. The first empty-capacitor instant occurs at about 0.50 ms; reversed full charge occurs at half a period.

Connect to a mass on a spring

Charge corresponds to displacement, current to velocity, inductance to mass, and reciprocal capacitance to spring stiffness. Capacitor energy plays the role of elastic energy; inductor energy plays the role of kinetic energy. Increasing the initial charge increases the energy and current amplitude but leaves the ideal circuit's frequency unchanged. Changing inductance or capacitance changes that frequency.

Key Takeaways

  • Charge and current are one-quarter period out of step.
  • An empty capacitor coincides with maximum current in an ideal LC cycle.
  • Total electric plus magnetic energy stays constant.
  • Frequency depends on L and C, while initial charge sets the amplitudes.
  • Convert angular frequency to hertz by dividing by 2π.
  • The mass–spring analogy maps charge to displacement and inductance to mass.

2.4 Recognize three forms of RLC decay

Add resistance to an LC loop and the resistor converts stored field energy to heat. The charge may oscillate with decreasing amplitude or return to equilibrium without oscillating, depending on the resistance.

Add the damping term

With i=dq/dt, the source-free series circuit obeys

Ld2qdt2+Rdqdt+qC=0.

Its total field energy changes at the rate dU/dt=−i2R. The sign is never positive: the resistor removes energy even when charge and current change sign. In the mechanical analogy, resistance corresponds to the damping constant of a mass–spring system.

Compare resistance with the critical value

The critical resistance is Rc=2L/C.

ResistanceBehavior
R<RcUnderdamped: charge oscillates with a shrinking envelope.
R=RcCritically damped: fastest nonoscillatory return for release from an initially charged capacitor with zero current.
R>RcOverdamped: nonoscillatory return that is slower than at critical damping.

For the underdamped case,

q(t)=Q0e−Rt/(2L)cos⁡(ω′t+ϕ), ω′=1LC−(R2L)2.

The envelope and the oscillation are separate features. The exponential controls how quickly peaks shrink; the cosine controls their spacing. Initial charge and current determine Q0 and ϕ. In particular, a damped cosine with zero phase does not in general have zero initial current, because its envelope is also changing.

Calculate a damped frequency and envelope

For L=25 mH, C=4.0 μF and R=10 Ω, the undamped angular frequency is about 3162 rad/s. The envelope decay rate is R/(2L)=200 s−1. Thus ω′≈3156 rad/s, about 0.2% lower.

The charge envelope halves when e−200t=1/2, giving t=ln⁡2/200≈3.47 ms. The critical resistance is about 158 Ω, so 10 Ω is well inside the underdamped regime. As resistance rises toward 158 Ω, the damped frequency falls toward zero. Its decrease is small only when damping is light.

Keep amplitude, energy and driven motion distinct

For light damping, stored energy follows an approximately exponential envelope e−Rt/L. Its exponent is twice the charge-amplitude exponent because energy depends on amplitude squared. The exact instantaneous loss remains i2R.

Using R/L in the charge envelope would therefore predict amplitude decay twice as fast as it actually occurs. A source-free circuit eventually loses its stored energy. A driven circuit can maintain oscillation by receiving energy from a source; its steady-state frequency is then the source frequency, not this free-decay frequency.

Key Takeaways

  • Compare resistance with 2√(L/C) to identify the damping regime.
  • The underdamped frequency is below the ideal LC frequency.
  • Charge amplitude decays with rate R/(2L).
  • For light damping, energy decays approximately twice as fast as amplitude.
  • Critical damping gives the fastest nonoscillatory discharge from rest.
3

Describe AC sources and single circuit elements with phasors

Sinusoidal sources require a description of both size and timing. Connect peak values to rms readings and resistor heating, then use the element laws to explain why current can lead or lag voltage. Phasors represent those phase relationships as rotating arrows. Their vector sums prepare you to combine several AC voltage drops without adding peaks that occur at different times.

3.1 Describe a sinusoidal supply and its rms value

An alternating source reverses polarity repeatedly. A rotating coil in a uniform magnetic field produces a sinusoidal emf, so sine waves give a useful description of generators and many AC circuits.

Describe the waveform

Write the source voltage as v(t)=V0sin⁡ωt. Its amplitude V0 is the largest voltage magnitude. The angular frequency ω is in radians per second; frequency f counts cycles per second in hertz:

ω=2πf,T=1/f.

For a rotating coil, the emf amplitude is NBAω, where N is the number of turns, B the field and A the coil area. Faster rotation raises both the frequency and the emf amplitude when the other quantities stay fixed.

A 50 Hz source has angular frequency about 314 rad/s and period 20 ms. A 60 Hz source has angular frequency about 377 rad/s and period about 16.7 ms. These are different descriptions of the same timing, not different types of oscillation.

Square before averaging

A sinusoidal current averages to zero over a full cycle, but a resistor still heats. Both positive and negative currents produce positive power p=i2R. The useful measure is the root-mean-square current:

Irms=i2‾.

For i=I0sin⁡ωt, the cycle average of sine squared is one-half. Therefore

Irms=I02,Vrms=V02.

For example, the squared-current average is i2‾=1T∫0TI02sin⁡2(ωt) dt. Using sin⁡2θ=(1−cos⁡2θ)/2, the cosine term averages to zero over a full period. The remaining I02/2 gives the rms value after taking the square root.

The rms value is the DC value that would produce the same average heating in a fixed resistor. Taking the ordinary average first would erase the waveform's magnitude and wrongly predict zero heating.

The factor of square root of two belongs to a sinusoid. For a square wave alternating between equal positive and negative peaks, the squared voltage is constant, so its rms value equals its peak magnitude.

Use rms values for heating

For a resistor,

Pavg=Irms2R=Vrms2R=VrmsIrms.

A 2000 W heating element supplied at 230 V rms has resistance 2302/2000≈26.5 Ω. Its rms current is 2000/230≈8.70 A; its peak current is about 12.3 A. Putting that peak into I2R without the cycle-average factor would double the average power.

Interpret supply ratings

Ordinary household supply ratings are rms values. A 230 V sinusoidal supply peaks near 325 V; a 120 V supply peaks near 170 V. Many regions use 220–240 V at 50 Hz, while ordinary outlets in the United States and Canada use 120 V at 60 Hz. Japan has 50 Hz systems in the east and 60 Hz systems in the west. Voltage and frequency ratings both matter when moving equipment between supplies; matching the voltage alone does not establish that its frequency rating matches.

Key Takeaways

  • Angular frequency, frequency and period obey ω = 2πf and T = 1/f.
  • Rms means square, average, then take the square root.
  • A sinusoidal rms value is its amplitude divided by √2.
  • Rms current gives the same resistor heating as an equal DC current.
  • The sinusoidal conversion factor does not apply to every waveform.

3.2 Find reactance and the current’s phase

A resistor, capacitor and inductor respond differently to the same sinusoidal voltage. Their element laws determine both current amplitude and the timing of the current relative to the voltage.

Start from each element law

For a resistor, v=Ri at every instant. If v=V0sin⁡ωt, then i=(V0/R)sin⁡ωt. Current and voltage reach corresponding peaks together: they are in phase.

For a capacitor, q=Cv and i=dq/dt. Differentiating gives

i=ωCV0cos⁡ωt=I0sin⁡(ωt+π/2).

Capacitor current leads voltage by 90°. It is largest when the voltage crosses zero and is changing fastest. Charge flows onto and off the plates, producing current in the connecting wires without charge crossing the dielectric.

For an inductor, the applied voltage is v=L di/dt. Integrating the sinusoid in steady state gives

i=−V0ωLcos⁡ωt=I0sin⁡(ωt−π/2).

Inductor current lags voltage by 90°. The voltage is largest when the current changes fastest, not when the current is largest.

Compare the amplitude ratios

Reactance relates voltage and current amplitudes and is measured in ohms:

ElementReactance or resistanceCurrent relative to voltage
ResistorRIn phase
InductorXL=ωLLags 90°
CapacitorXC=1/(ωC)Leads 90°

For either reactive element, V0=I0X and Vrms=IrmsX. The instantaneous equation v=iX is false because the current and voltage are out of phase. Ideal reactive elements store and return energy, giving zero average power over a full cycle.

Calculate at a stated frequency

A 10 μF capacitor at 60 Hz has ω≈377 rad/s and XC≈265 Ω. On 120 V rms, its rms current is about 0.452 A. At 50 Hz its reactance rises to about 318 Ω.

A 0.20 H inductor at 50 Hz has XL=2π(50)(0.20)≈62.8 Ω. On 230 V rms, its rms current is about 3.66 A. At 60 Hz its reactance rises to about 75.4 Ω. In both calculations, using frequency directly in place of angular frequency would miss the factor of 2π.

Predict frequency effects

Increasing frequency increases inductive reactance but decreases capacitive reactance. An ideal inductor approaches a wire in the steady-DC limit; a charged ideal capacitor blocks steady DC. In loudspeaker crossovers, these tendencies help route low frequencies through an inductor and high frequencies through a capacitor. The memory aid “ELI the ICE man” puts voltage E before current I for L, and current I before voltage E for C.

Key Takeaways

  • Resistor current and voltage are in phase.
  • Capacitor current leads voltage by 90°; inductor current lags by 90°.
  • Inductive reactance increases with frequency, while capacitive reactance decreases.
  • Reactance relates amplitudes or rms values, not instantaneous values.
  • Ideal inductors and capacitors return the energy they take during a cycle.
  • Convert frequency to angular frequency before calculating reactance.

3.3 Add AC voltages with phasors

Adding two sinusoidal voltages requires their relative timing as well as their amplitudes. A phasor represents a sinusoid as a rotating arrow, turning the addition into a vector problem.

Read a rotating arrow

For v=V0sin⁡(ωt+θ), draw an arrow of length V0 at angle ωt+θ from the horizontal. It rotates counterclockwise at angular speed ω. Its vertical projection is the instantaneous voltage.

At angle zero the voltage is zero and increasing. At 90° it is at its positive peak. The horizontal projection would give a cosine, so choosing it while writing a sine would shift the time reference by a quarter cycle.

Phasors at one frequency rotate together. Their relative angles stay fixed, so a diagram can show one instant without drawing the whole motion. A phasor farther ahead counterclockwise leads the other; one behind lags. Phasor arrows describe phase, not a physical rotation of charge around the circuit.

Use current as a reference

In a series circuit, choose the common current phasor along the horizontal axis at the pictured instant. The element voltages then point in these directions:

  • Resistor voltage points along the current, with length IR.
  • Inductor voltage points 90° ahead, with length IXL.
  • Capacitor voltage points 90° behind, with length IXC.

The inductor and capacitor voltages oppose each other in the diagram. Their lengths subtract along that axis. The resistor contribution lies at right angles to this net reactive contribution.

Add a pair of sinusoids

Suppose v1=(3.0 V)sin⁡ωt and v2=(4.0 V)sin⁡(ωt+90∘). Draw the first arrow horizontally and the second vertically upward. Their resultant has amplitude

V0=3.02+4.02=5.0 V.

Its angle ahead of the first is θ=arctan⁡(4.0/3.0)≈53.1∘. Thus the sum is a 5.0 V sinusoid with that phase lead. Adding amplitudes to get 7.0 V would assume the two voltages peak together, which they do not.

The vector rule works because vertical projection distributes over vector addition. At every instant, the projection of the resultant equals the sum of the two individual projections. Kirchhoff's voltage rule therefore remains valid for instantaneous voltages and for phasors added as vectors.

For a general angle θ between two phasors of lengths A and B, the resultant magnitude satisfies C2=A2+B2+2ABcos⁡θ. At zero separation it becomes A+B; at 180° it becomes ∣A−B∣. The perpendicular example is the middle case where the cosine term vanishes. Angle information therefore determines which addition rule applies.

Keep the diagram consistent

You can use rms lengths instead of peak lengths. Every arrow then shrinks by the same factor of square root of two, while all angles remain unchanged. Label which convention you use; mixing one rms arrow with one peak arrow changes the resultant incorrectly.

A fixed-frequency phasor diagram describes sinusoidal steady state. Just after connection, a circuit can also contain transient terms. Those terms decay in a resistive circuit, leaving the source-frequency response that the diagram represents.

Key Takeaways

  • A phasor records sinusoidal amplitude and phase.
  • With counterclockwise rotation and a sine convention, use the vertical projection.
  • Add phasors as vectors; amplitudes add arithmetically only when in phase.
  • Peak and rms phasor diagrams have the same angles.
  • Phasors describe sinusoidal steady state after transients have decayed.
4

Analyze series RLC circuits: impedance, resonance and power

A series resistor, inductor and capacitor share one current, but their voltage drops do not peak together. Combine their phasors to find impedance and phase, then vary the frequency to locate resonance and measure its width. Finally, connect the phase angle to average power and explain why a load can draw substantial current while absorbing less real power than the voltage–current product suggests.

4.1 Find current from series RLC impedance

In a series RLC circuit the same current passes through all three elements. Their voltage phasors have different directions, so the source voltage follows a vector sum. Impedance packages that sum into a voltage-to-current ratio.

Build the voltage triangle

Take current as the reference. Resistor voltage lies along it; inductor and capacitor voltages lie in opposite perpendicular directions. Using peak values,

V02=(I0R)2+(I0XL−I0XC)2.

Divide by current amplitude squared to obtain

Z=R2+(XL−XC)2,I0=V0/Z.

The same relation holds with rms values. Impedance is measured in ohms, but its reactive part does not represent heat loss. Subtract the two reactances before squaring: adding them would ignore their opposite phases.

Interpret the phase sign

Write the source and current as v=V0sin⁡ωt and i=I0sin⁡(ωt−ϕ). Then

tan⁡ϕ=XL−XCR,cos⁡ϕ=RZ.

Positive phase means the voltage leads and the current lags: the circuit is inductive. Negative phase means the current leads: the circuit is capacitive. For positive resistance, choose the phase between −90° and +90°. Squaring the net reactance for impedance removes its sign, so return to the unsquared difference to decide the phase.

Work through a complete circuit

A 120 V rms, 60 Hz source drives R=50 Ω, L=0.30 H and C=20 μF in series.

  1. Convert the frequency: ω=2π(60)≈377 rad/s.
  2. Calculate reactances: XL≈113.1 Ω and XC≈132.6 Ω.
  3. Subtract: the net reactance is about −19.5 Ω.
  4. Find Z≈53.7 Ω and Irms=120/Z≈2.24 A.
  5. Find ϕ≈−21.3∘. The current leads the source voltage.

Keep unrounded values in the calculator until the final result. Use the angle mode appropriate to the answer you report.

Check component voltages

The rms component voltages are approximately 112 V across the resistor, 253 V across the inductor and 296 V across the capacitor. Each reactive voltage can exceed the source voltage because their phasors nearly cancel. The source is their vector sum:

Vrms=VR2+(VL−VC)2≈120 V.

Each voltage comes from the same current: VR=IrmsR, VL=IrmsXL and VC=IrmsXC. Factoring that current out of the voltage triangle recovers Vrms=IrmsZ. Dividing its adjacent side by its hypotenuse gives cos⁡ϕ=VR/Vrms=R/Z, linking the geometry to the power factor.

For a series RL circuit, omit the capacitor contribution: Z=R2+XL2. For a series RC circuit, omit the inductor contribution: Z=R2+XC2. The omitted series element is replaced with a connecting wire.

Key Takeaways

  • Series impedance combines resistance with the difference of inductive and capacitive reactance.
  • Use I = V/Z with consistently peak or consistently rms values.
  • Positive φ means lagging current; negative φ means leading current.
  • Component voltages can exceed source voltage because their phasors cancel.
  • Removing a reactive contribution from the formula assumes a closed connecting wire remains.
  • Use the voltage triangle to check a calculated source voltage.

4.2 Find resonance and measure its sharpness

At a fixed source voltage, changing frequency changes the current in a series RLC circuit. Inductive reactance rises with frequency while capacitive reactance falls. At one frequency they cancel, making the current largest.

Locate the current peak

Set ωL=1/(ωC) to find

ω0=1LC,f0=12πLC.

At this resonance, Z=R, current is in phase with the source, and Irms=Vrms/R. Below resonance the circuit is capacitive and current leads. Above resonance it is inductive and current lags.

For a series circuit with fixed component values, resistance changes the peak's height and width but not the frequency of maximum current. This driven-current peak stays at the undamped LC frequency even though a freely decaying RLC oscillation has a lower damped frequency.

Describe width and quality factor

The quality factor and bandwidth are

Q=ω0LR=1RLC,Δω=RL,Q=ω0Δω.

Bandwidth is the difference between the two half-power frequencies. At either edge, average power is half its resonant value and current is 1/2 of its resonant value. Half power does not mean half current, since resistor power depends on current squared.

At a half-power point, I2R is half its resonant value. The impedance is therefore 2R, which requires ∣ωL−1/(ωC)∣=R. The lower frequency uses net reactance −R and the upper frequency uses +R. Solving these two equations gives a separation exactly equal to R/L. The two points are not generally equally spaced about ω0 on a linear frequency axis.

Smaller resistance produces a taller, narrower peak and a larger quality factor. A high quality factor selects a narrow frequency range; a low quality factor gives a broader response. Here the symbol Q means quality factor, not capacitor charge.

Calculate a resonance curve's features

Let L=50 mH, C=2.0 μF and R=20 Ω, driven by 10 V rms. Then ω0≈3162 rad/s and f0≈503 Hz. At resonance, rms current is 0.50 A and average power is 5.0 W.

The quality factor is about 7.9. Bandwidth is 400 rad/s, or about 64 Hz, with half-power frequencies near 2970 and 3370 rad/s. At twice the resonant angular frequency, the net reactance is about 237 Ω and the rms current falls to about 0.042 A.

Explain the large internal voltages

At resonance, XL=XC=ω0L. Each reactive voltage is Q times the source voltage. In the example, each is about 79 V rms even though the source is 10 V rms. Their opposing phasors cancel; neither component voltage is zero.

Changing capacitance lets a tuner move its resonant frequency. A 250 μH coil tuned to 1.0 MHz requires C=1/[(2πf)2L]≈101 pF. In steady state, the circuit responds at the driving frequency throughout the tuning process. Resonance identifies where that response becomes strongest, not the only frequency at which the circuit can carry AC.

Key Takeaways

  • Resonance occurs when inductive and capacitive reactances are equal.
  • At resonance, series impedance is R and current is in phase with the source.
  • Quality factor measures sharpness; bandwidth spans the half-power points.
  • Half-power current is the maximum current divided by √2.
  • Lower resistance narrows the peak without shifting the current-peak frequency.
  • Resonance cancels reactive voltages in the sum, not across each component.
  • A driven circuit oscillates at the source frequency.

4.3 Calculate real power and power factor

Voltage and current can each be large while a circuit absorbs little average power. Their relative phase matters because instantaneous power is their product. Energy sent into a reactive element during part of a cycle returns during another part.

Average the instantaneous product

For v=V0sin⁡ωt and i=I0sin⁡(ωt−ϕ), average p=vi over a full cycle. The result is

Pavg=12V0I0cos⁡ϕ=VrmsIrmscos⁡ϕ.

The product identity gives p=12V0I0[cos⁡ϕ−cos⁡(2ωt−ϕ)]. The second cosine averages to zero over a complete cycle, leaving the first term. Instantaneous power can therefore vary even when average power is constant; for a reactive load it can become negative while energy flows back toward the source.

The factor cos⁡ϕ is the power factor. In a series RLC circuit, cos⁡ϕ=R/Z, so the result reduces to Pavg=Irms2R. All average dissipation occurs in the resistance. Ideal inductors and capacitors have zero average power, although their instantaneous power changes sign.

Distinguish watts from volt-amperes

The product VrmsIrms is apparent power, measured in volt-amperes. Real average power is measured in watts and equals apparent power times power factor.

LoadPhase relationshipPower factor
Pure resistanceIn phase1
Ideal inductanceCurrent lags 90°0
Ideal capacitanceCurrent leads 90°0
Series RLC at resonanceIn phase1

The cosine has the same value for positive and negative phase. A power factor is therefore described as lagging for an inductive load or leading for a capacitive load when that distinction matters.

Check power by two routes

For the series circuit supplied at 120 V rms with R=50 Ω, Z≈53.7 Ω and rms current about 2.24 A, the power factor is about 0.93. Thus Pavg≈(120)(2.24)(0.93)≈250 W. The resistor calculation Irms2R gives the same result after rounding.

Using the source voltage in V2/R would instead give 288 W. That formula needs the voltage across the resistor, about 112 V in this circuit. At resonance the resistor voltage equals the source voltage, so the maximum power becomes Vrms2/R.

Explain why correction reduces supply losses

For a fixed real load power, Irms=P/(Vrmscos⁡ϕ). A 1200 W motor on 230 V rms at power factor 0.80 draws about 6.52 A. At unity power factor the same power needs about 5.22 A. The larger current increases heating in supply wires according to I2R.

A parallel capacitor can supply leading current locally to offset some of an inductive load's lagging current. The supply current then decreases while the load's real power stays the same. This is power factor correction: it reduces unnecessary current in the supply path. It does not remove the real energy required by the motor.

Key Takeaways

  • Average AC power includes the power factor cos φ.
  • Apparent power is measured in VA; real power is measured in W.
  • Use the resistor voltage when calculating its power as V²/R.
  • Leading and lagging identify phase signs that the cosine alone cannot show.
  • Improving power factor reduces supply current for the same real load power.
5

Explain transformers and AC power distribution

Changing magnetic flux allows a transformer to trade voltage for current while conserving energy in the ideal model. Use turns ratios to analyze a loaded transformer, then distinguish real heating losses from leakage flux. Follow the same ideas into power distribution: high voltage reduces line current and heating, while local conversion supplies useful voltages. Stored energy and high voltage also explain the main electrical hazards.

5.1 Use transformer ratios and identify real losses

A transformer transfers energy between coils through changing magnetic flux. Its primary receives AC, and the common core guides flux through the secondary. Different turn counts give different voltages without requiring a direct electrical connection between the windings.

Derive the turns ratio

In the ideal model, the same flux threads every turn of both coils. With matching voltage reference directions, each winding voltage is its turn count times the flux-change rate:

vp=NpdΦdt,vs=NsdΦdt.

Taking the ratio gives Vs/Vp=Ns/Np for voltage magnitudes, whether peak or rms. More secondary turns produce a step-up transformer; fewer produce a step-down transformer.

For a resistive load and an ideal transformer, input and output power are equal:

VpIp=VsIs,IsIp=NpNs.

Voltage and current ratios run in opposite directions. Raising voltage reduces current for the same transferred power. The transformer does not multiply energy.

Calculate a loaded transformer

A primary with 1150 turns receives 230 V rms. Its 60-turn secondary supplies a resistive load drawing 2.0 A. The secondary voltage is 230(60/1150)=12.0 V. Output power is 24 W, so primary current is 24/230≈0.104 A.

The load determines the current demand. In the ideal model, an open secondary draws no load current and no real input power. A real unloaded transformer still needs a small magnetizing current and supplies its core losses. When the load draws more current, the primary draws more power to support it.

Reflect a resistance to the primary

A load resistance RL appears to the source as

Req=(NpNs)2RL.

This follows by dividing the transformed voltage by the oppositely transformed current. A turns ratio Np/Ns=10 makes an 8.0 Ω secondary load appear as 800 Ω at the primary. The squared ratio explains how transformers match a source to a load.

Separate dissipative losses from imperfect coupling

Real windings dissipate energy through their resistance. Changing core flux drives eddy currents and repeatedly magnetizes the core, producing hysteresis losses. Thin insulated core laminations reduce eddy-current paths. These losses make output real power smaller than input real power.

Some flux fails to link both windings. This leakage flux acts like an additional series inductance and contributes to voltage drop under load; leakage itself is not a dissipative loss. Large power transformers can exceed 99% efficiency, while small devices generally have lower efficiency.

A steady DC current produces constant flux after switching transients end, so it gives no continuing secondary emf. A transformer therefore needs changing flux to sustain its output. The brief pulses at switching do not provide continuous voltage conversion on steady DC.

Key Takeaways

  • Transformers use mutual induction through a shared changing flux.
  • Voltage follows the turns ratio; current follows the inverse ratio.
  • Ideal power conservation applies to a resistively loaded transformer.
  • Reflected resistance changes by the square of the primary-to-secondary turns ratio.
  • Winding resistance, eddy currents and hysteresis dissipate energy.
  • Leakage flux changes coupling and voltage regulation without itself dissipating energy.
  • Steady DC cannot sustain transformer output.

5.2 Explain transmission losses and electrical hazards

Electric power often travels far from where it is generated. The wires have resistance, so some transmitted energy becomes heat. Transformers make it possible to change voltage between efficient long-distance transmission and local delivery.

Calculate line heating from current

If the total line resistance is Rline, the heating loss is

Ploss=I2Rline.

For a fixed receiving-end power P and receiving-end rms voltage V at unity power factor, I=P/V. Thus

Ploss=P2RlineV2.

Increasing voltage by a factor of 20 reduces current by 20 and heating loss by 400. The comparison holds delivered power and line resistance fixed.

Suppose 10 MW is delivered through lines with total resistance 5.0 Ω. At 20 kV the current is 500 A and the loss is 1.25 MW, or 12.5% of delivered power. At 400 kV the current is 25 A and the loss is 3125 W, about 0.03% of delivered power. The source must provide delivered power plus these losses.

Use the voltage across the right component

The transmission voltage is mostly across the receiving load. It is not the voltage across the resistance of the wires. The line voltage drop is IRline: 2500 V in the first case and 125 V in the second.

You can calculate heating as Vdrop2/Rline, but inserting the full transmission voltage into that expression would describe an entirely different circuit. First identify where each voltage is measured.

Follow power through the grid

Large generators commonly supply about 10–25 kV. Step-up transformers raise voltage to hundreds of kilovolts for transmission. Substations reduce it for distribution, and local transformers reduce it again for users. Typical household supplies include about 230 V and about 120 V.

Frequency is standardized within each interconnected AC system, commonly at 50 or 60 Hz. Connected synchronous generators stay in step with that frequency. A country can contain separate frequency systems: Japan's eastern and western regions use 50 and 60 Hz, linked by frequency-converter stations.

High-voltage DC is also used for long routes and undersea cables. Converter stations connect these links to AC systems. A conventional transformer cannot change a steady DC voltage, so voltage conversion in a DC link needs conversion equipment.

Recognize stored-energy and high-voltage hazards

Household voltages can drive lethal current through the body, and transmission voltages can arc across an air gap. Use low-voltage supplies for experiments and stay clear of power lines and substations. Never interrupt a large coil's current by hand. Capacitors can retain charge after disconnection, and resonant circuits can build component voltages far above the source voltage. Disconnecting a source alone does not establish that a circuit is safe to touch.

Key Takeaways

  • Line heating is I²R for the resistance of the complete current path.
  • At fixed delivered power and unity power factor, line loss falls as voltage squared increases.
  • The line voltage drop differs from the voltage delivered to the load.
  • Transformers raise transmission voltage and lower it again for local use.
  • AC systems can have different standard frequencies and need converters to exchange power.
  • Stored energy and arcing remain hazards beyond the supply’s stated voltage.

Inductance and AC Circuits examples

5 Walkthroughs

1

From linked flux to stored magnetic energy

14 steps
Calculate coupling, self-induced voltage and energy by connecting coil fields to circuit quantities.
  1. 1
    IntroductionWhat a changing current does

    A coil carrying current produces magnetic flux. If that current changes, the flux can induce an emf in the same coil or in a neighboring one.

    Follow the chain from field to flux linkage to induced emf. Then use the work needed to build the current to find magnetic energy. The central distinction is between the current that creates a field and the rate of current change that creates the induced emf.

  2. 2
    ExplanationCount every linked turn

    For two linear coils, define mutual inductance by M=N2Φ21/I1. The flux is through one receiving turn; multiplying by N2 counts all its turns.

    The induced emf is ε2=−M dI1/dt. A steady current can create substantial flux without creating an emf. The minus sign tells you to oppose the flux change when choosing the induced direction.

  3. 3
    ExampleFind the field and receiving area

    A long solenoid has 1000 turns over 0.50 m. A coaxial 200-turn coil of radius 1.5 cm sits near its center.

    Imagine current I1 in the long solenoid, whose field is B1=μ0N1I1/ℓ. One inner turn receives flux B1π(0.015)2. Use the inner turn's own area: magnetic field outside that loop does not contribute to its flux.

  4. 4
    ExampleConvert flux linkage into coupling

    Multiply the one-turn flux by 200 and divide by the imagined current. The current cancels:

    M=μ0N1N2πr22ℓ≈0.355 mH.

    For a source current increasing at 50 A/s, calculate the emf magnitude:

    ∣ε∣=(3.55×10−4)(50)≈17.8 mV.

    Reciprocity gives the same mutual inductance when the coils exchange source and receiver roles.

  5. 5
    ChallengeChange the rate, not the current

    A pair of coils has mutual inductance 6.0 mH. The source current rises from 1.0 A to 4.0 A in 0.020 s. What emf magnitude is induced in the other coil?

    ---reveal---

    The rate is 3.0/0.020=150 A/s. Therefore ∣ε∣=(0.0060)(150)=0.90 V. Using the final current alone would not determine an emf; the time interval is essential.

  6. 6
    ExplanationLink a coil to its own field

    Self-inductance uses the coil's own flux: L=NΦB/I. A long solenoid has field proportional to its turn count, and each of its turns links that field.

    Thus L=μ0N2A/ℓ. The squared turn count has two origins: producing a stronger field and linking more turns. A toroid instead needs a radial field integral because its field decreases with radius.

  7. 7
    Key InsightKeep voltage signs and current continuity together

    Crossing an inductor along its current gives potential change −L dI/dt. This is a drop during current growth and a rise during decay.

    With finite voltage, current cannot jump: a jump would require an infinite derivative. Yet the voltage can change abruptly when a switch moves. Preserve the initial current first, then let the new circuit determine its rate of change.

  8. 8
    ChallengeRead a decaying current

    A 0.15 H coil carries positive current that is falling at 40 A/s. Traversing the ideal inductor in that current's direction, do you encounter a potential rise or drop, and of what size?

    ---reveal---

    The change is −L dI/dt=−(0.15)(−40)=+6.0 V: a rise. The coil is supplying energy to sustain the existing current while its magnetic field decreases.

  9. 9
    ExplanationIntegrate the work needed to build current

    Power entering an ideal inductor is P=LI dI/dt. During a small current increase, the stored energy changes by dU=LI dI.

    Integrate from zero current:

    U=∫0ILI′ dI′=12LI2.

    This is magnetic storage. When current decreases, the inductor can return the energy. Reversing current at unchanged magnitude leaves this squared-current energy unchanged.

  10. 10
    ExampleCheck stored energy in the field

    The 0.395 mH solenoid carrying 2.0 A stores LI2/2≈0.79 mJ.

    Its field is about 5.03 mT. In air, uB=B2/(2μ0)≈10.1 J/m3. Multiplying by its field-filled volume, about 7.85×10−5 m3, gives the same energy. The circuit and field calculations count the same stored work.

  11. 11
    ConnectionUse field energy when flux is awkward

    For a thin-conductor coaxial cable, the magnetic field varies as 1/r between the conductors. A shell of thickness dr has volume 2πrℓ dr.

    Integrating B2/(2μ0) over those shells gives U=μ0I2ℓln⁡(b/a)/(4π). Compare this with LI2/2 to obtain L/ℓ=μ0ln⁡(b/a)/(2π) without a flux-linkage calculation.

  12. 12
    ChallengeSeparate voltage from stored energy

    An ideal 0.60 H inductor carries a steady 2.0 A. What are its voltage and stored energy at that instant?

    ---reveal---

    Its voltage is zero because the current derivative is zero. Its energy is 12(0.60)(2.0)2=1.2 J. Zero voltage means energy is not changing at that instant; it does not mean that the magnetic field contains no energy.

  13. 13
    ChallengePredict two effects of rewinding

    A long solenoid is rewound with twice its original turns, keeping length and area fixed. It then carries the same current as before. How do its back-emf magnitude at a given current-change rate and its stored energy change?

    ---reveal---

    Both become four times as large. The new inductance is four times larger, and both L∣dI/dt∣ and LI2/2 scale with inductance under these fixed conditions.

  14. 14
    RecapChoose the quantity that matches the question

    For coupling or self-inductance, start with field and flux linkage. For induced emf, use the current-change rate and Lenz's law. For stored energy, use current squared or integrate field energy density.

    These choices separate three quantities that can behave differently: a steady current can produce flux and store energy while producing no self-induced voltage.

2

Follow a circuit through switching and oscillation

18 steps
Use initial conditions, changing current paths and energy to explain RL and RLC time responses.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionStart with the current already present
  2. 2
    ExplanationWrite the growth equation
  3. 3
    ExampleCalculate a growing current
  4. 4
    ChallengeFind the wait for a chosen fraction
  5. 5
    TipRebuild the network at each limit
  6. 6
    ExplanationLet the field drive the decay
  7. 7
    Key InsightWatch energy fall faster than current
  8. 8
    ChallengeUse a new decay resistance
  9. 9
    ExplanationFollow the first quarter cycle
  10. 10
    ExplanationUse the charge equation
  11. 11
    ExampleFind the energy and maximum current
  12. 12
    ChallengeCheck what changes the frequency
  13. 13
    AnalogyMatch the oscillator to a spring
  14. 14
    ExplanationLet resistance drain the oscillation
  15. 15
    ExampleSeparate the envelope from the frequency
  16. 16
    ChallengeChoose the fastest nonoscillatory case
  17. 17
    ChallengeAccount for energy at the first charge peak
  18. 18
    RecapMatch each time response to its cause
3

Read AC size, timing and phasors

13 steps
Connect rms readings to waveform peaks, element laws to phase, and rotating arrows to sinusoidal sums.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionTrack size and timing separately
  2. 2
    ExplanationRead the sine wave’s parameters
  3. 3
    ExplanationAverage the square for heating
  4. 4
    ExampleMove between a rating and a peak
  5. 5
    ChallengeRead a voltage equation
  6. 6
    ExplanationDifferentiate capacitor voltage
  7. 7
    ConnectionCompare resistance and inductance
  8. 8
    ChallengePredict a frequency change
  9. 9
    ExplanationTurn phase into an arrow angle
  10. 10
    ExampleDraw two perpendicular contributions
  11. 11
    ExampleFind the sum’s timing
  12. 12
    ChallengeCombine opposing reactive arrows
  13. 13
    RecapKeep a consistent AC description
4

Solve a series AC circuit and vary its frequency

16 steps
Build the voltage triangle, identify resonance, and connect phase to average power and supply current.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionOne current, three voltage directions
  2. 2
    ExplanationBuild impedance from a right triangle
  3. 3
    ExampleCalculate reactances first
  4. 4
    ExampleFind current and phase
  5. 5
    ChallengeInfer the missing reactance
  6. 6
    Key InsightCheck voltages as vectors
  7. 7
    ExplanationTune the reactive sum to zero
  8. 8
    ExplanationMeasure the peak’s width
  9. 9
    ExampleCalculate a resonator’s internal voltage
  10. 10
    ChallengeChange only resistance
  11. 11
    ExplanationInclude phase when finding real power
  12. 12
    ExampleCheck power with the resistor
  13. 13
    ConnectionReduce current without reducing load power
  14. 14
    ChallengeCompare line heating before and after correction
  15. 15
    ChallengeFind real power from phase and impedance
  16. 16
    RecapUse phase to connect current, tuning and power
5

Transform voltage and account for transmission losses

12 steps
Use flux, turns ratios and energy conservation to follow power through transformers and resistive lines.

Save this lesson to follow every Walkthrough step by step.

  1. 1
    IntroductionTrade voltage for current
  2. 2
    ExplanationShare a flux-change rate
  3. 3
    ExampleFind the secondary voltage
  4. 4
    ExampleLet the load set the current
  5. 5
    ChallengeReflect a resistance
  6. 6
    Key InsightSeparate heat loss from leakage
  7. 7
    ExampleCalculate the low-voltage transmission case
  8. 8
    ExampleRaise voltage while holding delivered power fixed
  9. 9
    ChallengeUse the line drop in a heating calculation
  10. 10
    ConnectionConnect systems with different supplies
  11. 11
    ChallengeAccount for the source’s extra power
  12. 12
    RecapFollow power and label each voltage

Inductance and AC Circuits practice questions

40 Practice Questions in 4 sets

Set 1: Switching paths, stored energy and phase10 Practice Questions

Question 1 of 10

Two coils have self-inductances 0.20 H and 0.45 H and coupling coefficient 0.60. One coil’s current falls at 8.0 A/s. What emf magnitude is induced in the other?
  1. 0.96 V
  2. 2.40 V
  3. 0.432 V
  4. 1.44 V
Show answerHide answer
Answer: D
The mutual inductance is M=kL1L2=0.60(0.20)(0.45)=0.18 H. The induced magnitude is then M∣dI/dt∣=(0.18)(8.0)=1.44 V. The 2.40 V result assumes perfect coupling and ignores the given coefficient.

Question 2 of 10

A rectangular air-core toroid keeps its turn count and height fixed. Its inner and outer radii are both doubled. How does its self-inductance change?
  1. It doubles.
  2. It stays the same.
  3. It halves.
  4. It becomes four times as large.
Show answerHide answer
Answer: B
Toroid inductance is proportional to hln⁡(R2/R1) at fixed turn count. Doubling both radii leaves their ratio unchanged, so the inductance is unchanged. A prediction of half the inductance accounts for the weaker field at larger radius but misses the wider radial integration region.

Question 3 of 10

A thin-conductor coaxial cable has inner radius 1.0 mm, outer radius 3.0 mm and length 4.0 m. It carries 5.0 A outward and the same return current. What magnetic energy is stored between its conductors? Use μ0=4π×10−7 H/m.
  1. 11.0 μJ
  2. 22.0 μJ
  3. 2.75 μJ
  4. 8.79 μJ
Show answerHide answer
Answer: A
The inductance per length is μ0ln⁡(3)/(2π)≈2.20×10−7 H/m, so total inductance is about 0.879 μH. Its energy is LI2/2≈11.0 μJ. The 22.0 μJ value omits the one-half factor after correctly finding the inductance.

Question 4 of 10

A 24 V battery feeds a 6.0 Ω resistor, then two parallel branches: a 12 Ω resistor and an initially unenergized ideal inductor. What are the battery currents immediately after connection and long afterward?
  1. 4.0 A, then 1.33 A
  2. 2.0 A, then 4.0 A
  3. 1.33 A, then 4.0 A
  4. 1.33 A, then 2.0 A
Show answerHide answer
Answer: C
Initially the inductor current stays zero, leaving the two resistors in series and battery current 24/18=1.33 A. Long afterward the ideal inductor bypasses the 12 Ω branch, leaving 24/6=4.0 A. Treating the final branches as two ordinary resistors misses the inductor’s zero DC voltage drop.

Question 5 of 10

A series RL current approaches a final value of 4.0 A. It reaches 3.0 A after 0.12 s. What is the circuit’s time constant?
  1. 0.173 s
  2. 0.040 s
  3. 0.120 s
  4. 0.0866 s
Show answerHide answer
Answer: D
The reached fraction is 0.75, so the remaining gap is e−t/τ=0.25. Therefore τ=0.12/ln⁡4≈0.0866 s. Using the reached fraction as the exponential would confuse the rising current with the shrinking gap between that current and its final value.

Question 6 of 10

A 30 V battery and 5.0 Ω resistor feed a 20 Ω resistor in parallel with a 0.50 H ideal inductor. After a long time, the battery branch is opened while the other two branches remain connected. How much energy is dissipated during the next 25 ms?
  1. 1.22 J
  2. 7.78 J
  3. 9.00 J
  4. 3.31 J
Show answerHide answer
Answer: C
The steady inductor current is 30/5=6.0 A, storing 9.0 J. The remaining 20 Ω loop has time constant 25 ms, so after that interval energy is 9e−2 J and heat released is 9(1−e−2)≈7.78 J. The 1.22 J value is energy still stored, not dissipated.

Question 7 of 10

An ideal LC circuit starts with maximum charge on its capacitor. Later the charge magnitude is one-half its maximum. What fraction of the maximum current magnitude is present?
  1. 0.500
  2. 0.866
  3. 0.750
  4. 0.707
Show answerHide answer
Answer: B
Capacitor energy depends on charge squared, so one-half maximum charge leaves one-quarter of the total energy electric. The remaining three-quarters is magnetic, giving ∣i∣/Imax⁡=3/4≈0.866. The value 0.750 is the magnetic energy fraction, not the current fraction.

Question 8 of 10

A lightly damped source-free series RLC circuit loses half its charge-envelope amplitude in 8.0 ms. Its inductance is 0.20 H. What is its resistance, and approximately what energy fraction remains after 16 ms?
  1. 34.7 Ω and 1/16
  2. 17.3 Ω and 1/4
  3. 34.7 Ω and 1/4
  4. 17.3 Ω and 1/16
Show answerHide answer
Answer: A
The envelope law gives R=2Lln⁡2/(0.0080)≈34.7 Ω. After two amplitude half-times the envelope is one-quarter, so the light-damping energy envelope is about one-sixteenth. The 17.3 Ω result uses the energy decay rate in the charge-amplitude equation and loses a factor of two.

Question 9 of 10

A sinusoidal voltage is applied across an ideal inductor in steady state. How is the current timed relative to that voltage?
  1. It leads by one-quarter cycle.
  2. It is in phase with voltage.
  3. It lags by one-quarter cycle.
  4. It lags by one-half cycle.
Show answerHide answer
Answer: C
Inductor voltage is proportional to the rate of current change, so a sinusoidal current reaches its peak one-quarter cycle after the voltage peak. Current therefore lags voltage by 90°. A quarter-cycle lead describes an ideal capacitor, whose current follows the rate of voltage change.

Question 10 of 10

Two same-frequency rms voltage phasors have magnitude 10 V each and differ in phase by 120°. What is the rms magnitude of their sum?
  1. 20 V
  2. 14.1 V
  3. 17.3 V
  4. 10 V
Show answerHide answer
Answer: D
Vector addition gives V2=102+102+2(10)(10)cos⁡120∘=100, so the resultant is 10 V rms. The 14.1 V value assumes a 90° separation, not the stated 120°. There is no extra peak conversion because all phasor magnitudes use the same rms convention.
Set 2: Diagnose and combine AC circuit behavior10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A transformer supplies a resistive load at 24 V rms and 3.0 A rms with 90% efficiency. The primary voltage is 120 V rms and its input power factor is 1. What is the primary rms current?
  1. 0.54 A
  2. 0.60 A
  3. 0.667 A
  4. 0.750 A
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A sinusoidal source supplies a fixed 18 Ω resistor with average power 100 W. What is the peak source voltage?
  1. 60.0 V
  2. 42.4 V
  3. 30.0 V
  4. 84.9 V
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A series RLC circuit draws 2.0 A rms from 100 V rms and dissipates 160 W in its resistor. Its current leads source voltage, and its inductive reactance is 25 Ω. What is its capacitive reactance?
  1. 5 Ω
  2. 30 Ω
  3. 55 Ω
  4. 65 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

A series RLC circuit has resistance 15 Ω and rms component voltages 30 V across the resistor, 80 V across the inductor and 40 V across the capacitor. What is the source rms voltage?
  1. 150 V
  2. 50 V
  3. 90 V
  4. 70 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A series resonator has resonant frequency 500 Hz and half-power bandwidth 50 Hz. It is driven at resonance by 12 V rms. What is the rms voltage across its capacitor?
  1. 12 V
  2. 60 V
  3. 240 V
  4. 120 V
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

A series RLC circuit is at current resonance. Its capacitance is then multiplied by four, and the driving frequency is doubled; inductance and resistance stay fixed. What is the new net reactance in units of the original resonant inductive reactance?
  1. +1.50
  2. +1.875
  3. −1.875
  4. +0.875
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A sinusoidal load has apparent power 500 VA and real power 400 W. What is its power factor?
  1. 1.25
  2. 0.60
  3. 0.80
  4. 0.64
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A 900 W inductive load operates at 150 V rms with power factor 0.75. A parallel capacitor corrects the supply power factor to 1 without changing load power or voltage. The total supply-wire resistance is 0.50 Ω. How much does the wire heating decrease?
  1. 14 W
  2. 8 W
  3. 18 W
  4. 32 W
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

An ideal transformer’s primary is connected to 120 V rms and draws 0.20 A rms while its secondary powers a 6.0 Ω resistor. What is the primary-to-secondary turns ratio?
  1. 14.1:1
  2. 5:1
  3. 20:1
  4. 10:1
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A resistive receiver takes 800 kW at 40 kV rms through lines of total resistance 10 Ω. What real power must the source supply, and what is the line voltage drop?
  1. 800 kW and 200 V
  2. 804 kW and 200 V
  3. 804 kW and 40 kV
  4. 796 kW and 200 V
Show answerHide answer

Save this lesson to see this answer.

Set 3: Series AC circuits and transformers10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A series circuit has resistance 30 Ω, inductive reactance 70 Ω and capacitive reactance 30 Ω. What is its impedance?
  1. 130 Ω
  2. 50 Ω
  3. 70 Ω
  4. 100 Ω
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

A series RLC circuit has resistance 24 Ω, inductive reactance 18 Ω and capacitive reactance 50 Ω. What is the phase angle by which source voltage leads current?
  1. +53.1°
  2. −36.9°
  3. +36.9°
  4. −53.1°
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A series tuning circuit has 80 mH inductance and 5.0 μF capacitance. At what frequency is its steady-state current largest?
  1. 252 Hz
  2. 1.58 kHz
  3. 503 Hz
  4. 126 Hz
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

At resonance, a series RLC circuit draws 0.30 A rms from a 9.0 V rms source. At that frequency its inductor has reactance 150 Ω. What are its quality factor and rms capacitor voltage?
  1. 5.0 and 9.0 V
  2. 16.7 and 150 V
  3. 5.0 and 45 V
  4. 16.7 and 45 V
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A sinusoidal load receives 48 V rms, draws 5.0 A rms and has power factor 0.60. What real average power does it receive?
  1. 240 W
  2. 144 W
  3. 400 W
  4. 72 W
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

An inductive load’s power factor is corrected from 0.60 to 0.90 while its real power and supply voltage stay fixed. What fraction of the original supply-wire heating remains?
  1. 4/9
  2. 2/3
  3. 3/2
  4. 9/4
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

An ideal transformer has 900 primary turns and 150 secondary turns. The primary receives 180 V rms, and a resistive secondary load draws 3.0 A rms. What is the primary rms current?
  1. 18 A
  2. 3.0 A
  3. 0.083 A
  4. 0.50 A
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A transformer core is replaced with one made of thin insulated laminations. Which core-loss mechanism is directly reduced by the interrupted conducting paths?
  1. Winding-resistance heating
  2. Magnetic hysteresis loss
  3. Circulating eddy-current heating
  4. Voltage drop from leakage flux
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

A receiver takes 2.0 MW at 100 kV rms and unity power factor through lines of total resistance 12 Ω. How much power heats the lines?
  1. 4.8 kW
  2. 240 kW
  3. 20 kW
  4. 480 kW
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

A resistive load receives 600 kW through lines of total resistance 8.0 Ω. Their combined heating must be no more than 1.2 kW. What is the minimum receiving-end rms voltage?
  1. 40.0 kV
  2. 49.0 kV
  3. 69.3 kV
  4. 24.5 kV
Show answerHide answer

Save this lesson to see this answer.

Set 4: Inductance, switching and AC foundations10 Practice Questions

Save this lesson to see every answer and practice every set.

Question 1 of 10

A sensor coil has mutual inductance 8.0 mH with a nearby coil. The nearby current rises at 15 A/s. What is the magnitude of the sensor’s induced emf?
  1. 0.0080 V
  2. 1.88 V
  3. 0.120 V
  4. 120 V
Show answerHide answer

Save this lesson to see this answer.

Question 2 of 10

An air-core solenoid is rewound with twice as many turns while its length and cross-sectional area stay fixed. How does its inductance change?
  1. It becomes four times as large.
  2. It becomes twice as large.
  3. It becomes half as large.
  4. It becomes one-quarter as large.
Show answerHide answer

Save this lesson to see this answer.

Question 3 of 10

A 0.40 H inductor carries 3.0 A. How much energy is stored in its magnetic field?
  1. 0.60 J
  2. 1.20 J
  3. 3.60 J
  4. 1.80 J
Show answerHide answer

Save this lesson to see this answer.

Question 4 of 10

An initially unenergized 0.48 H inductor and 12 Ω resistor are connected in series to 18 V DC. What is the current after 0.080 s?
  1. 0.203 A
  2. 1.30 A
  3. 0.948 A
  4. 1.50 A
Show answerHide answer

Save this lesson to see this answer.

Question 5 of 10

A 0.80 H inductor initially carries 2.5 A. Its source is removed, leaving a 10 Ω decay loop. How much of its initial magnetic energy remains after 0.080 s?
  1. 36.8%
  2. 63.2%
  3. 13.5%
  4. 86.5%
Show answerHide answer

Save this lesson to see this answer.

Question 6 of 10

An ideal LC circuit starts with a fully charged capacitor and zero current. Where is its stored energy when the capacitor first becomes uncharged?
  1. Entirely in the electric field
  2. Equally in both fields
  3. Converted to thermal energy
  4. Entirely in the magnetic field
Show answerHide answer

Save this lesson to see this answer.

Question 7 of 10

A source-free series circuit has 40 mH inductance, 10 μF capacitance and 80 Ω resistance. What form does its charge response have?
  1. Oscillations with shrinking peaks
  2. Oscillations with constant peaks
  3. A critically damped return
  4. An overdamped return
Show answerHide answer

Save this lesson to see this answer.

Question 8 of 10

A sinusoidal current has peak magnitude 6.0 A and flows through a 5.0 Ω resistor. What is the average heating power?
  1. 180 W
  2. 90 W
  3. 30 W
  4. 127 W
Show answerHide answer

Save this lesson to see this answer.

Question 9 of 10

The frequency of a sinusoidal source is doubled while its rms voltage stays fixed. It drives only an ideal capacitor. How does the rms current change?
  1. It becomes one-quarter as large.
  2. It becomes half as large.
  3. It becomes four times as large.
  4. It becomes twice as large.
Show answerHide answer

Save this lesson to see this answer.

Question 10 of 10

Two same-frequency voltage phasors have peak magnitudes 8.0 V and 6.0 V. Their resultant has peak magnitude 10.0 V. The 6.0 V phasor leads the 8.0 V phasor by an angle between 0° and 180°. By how much does the resultant lead the 8.0 V phasor?
  1. 36.9°
  2. 53.1°
  3. 90.0°
  4. 45.0°
Show answerHide answer

Save this lesson to see this answer.

Stuck on your own question? Homework Help

Key Terms

74 Key Terms, each with its definition

A

Alternating current
An alternating current changes direction repeatedly; a sinusoidal alternating current also varies smoothly in magnitude through each cycle.
A sinusoidal alternating current can average to zero over a cycle while still heating a resistor.
Amplitude envelope
An amplitude envelope is a curve describing the changing maximum size of an oscillation, distinct from its rapid sign changes.
The charge amplitude envelope in an underdamped RLC loop falls as e−Rt/(2L).
Angular frequency
Angular frequency is the rate of change of sinusoidal phase in radians per second, equal to 2π times frequency in hertz.
A 60 Hz source has angular frequency about 377 rad/s, which belongs in reactance formulas.
Apparent power
Apparent power is the product of rms voltage and rms current, measured in volt-amperes without including the phase-angle factor.
A load drawing 4 A rms at 50 V rms has apparent power 200 VA, even if its real power is lower.
Average real power
Average real power is net energy transferred per unit time over a cycle, equal to rms voltage times rms current times power factor for sinusoids.
Average real power becomes heat in the resistance of an idealized series RLC circuit.

B

Back emf
A back emf is the self-induced emf that opposes a change in current, resisting growth and supporting the current during decay.
During a coil’s discharge, its back emf drives current in the same direction as the original current.
Bandwidth
Bandwidth is the separation between a series resonator’s two half-power frequencies; its angular-frequency value equals resistance divided by inductance.
Lowering resistance narrows bandwidth while leaving the series current-peak frequency unchanged.

C

Capacitive reactance
Capacitive reactance is the voltage-to-current magnitude ratio of an ideal capacitor in sinusoidal steady state, equal to one divided by ωC.
Increasing capacitance lowers capacitive reactance and increases current at the same frequency and voltage.
Charge amplitude
Charge amplitude is the greatest magnitude of charge on the chosen capacitor plate during an oscillation, setting its maximum electric energy.
An initially charged capacitor at 12 V with 2.0 μF capacitance has charge amplitude 24 μC.
Coaxial cable
A coaxial cable has an inner conductor surrounded by an outer conductor on the same axis, carrying outward and return currents.
For thin conductors, a coaxial cable stores magnetic field energy in the space between their radii.
Coupling coefficient
The coupling coefficient is the dimensionless ratio of mutual inductance to the geometric mean of two coils’ self-inductances.
A coupling coefficient close to one indicates that the two coils share magnetic flux very effectively.
Critical damping
Critical damping is the boundary between oscillatory and overdamped response, giving the fastest nonoscillatory discharge from initial charge at rest.
Critical damping in a series RLC circuit occurs when resistance equals twice √(L/C).
Current continuity
Current continuity in an inductor means that its current cannot jump instantaneously when the voltage across it remains finite.
Current continuity preserves an energized coil’s current as a switch connects it to a new decay path.
Current half-time
The current half-time is the interval over which an exponential RL decay current falls to half its starting value, equal to τ ln 2.
After two current half-times, an RL loop carries one-quarter of its original current.

D

Damped angular frequency
The damped angular frequency is the oscillation rate within a decaying underdamped response, lower than the ideal LC angular frequency.
Near critical resistance, the damped angular frequency can be much smaller than its undamped value.
Decay path
A decay path is the closed route available to inductor current after switching, whose resistance determines the decay time constant.
Opening a battery branch can leave a decay path through a resistor that previously carried no current.

E

Eddy currents
Eddy currents are circulating currents induced within conducting material by changing magnetic flux, producing resistive heating in a transformer core.
Core laminations interrupt large eddy currents and reduce the heating they would otherwise produce.
Energy exchange
Energy exchange in an LC loop is the transfer between electric and magnetic storage as the capacitor discharges and reverses polarity.
LC energy exchange continues past zero capacitor charge because the inductor sustains the current.

F

Field-energy integral
A field-energy integral adds the energy density over space to find total stored energy when the field varies from point to point.
A coaxial cable’s field-energy integral sums thin cylindrical shells between its conductors.
Flux linkage
Flux linkage is the sum of the magnetic flux through all turns of a coil; identical turns give the flux per turn times turn count.
A receiving coil with 100 identical turns has flux linkage 100 times the flux through one turn.
Frequency
Frequency is the number of complete oscillation cycles per second, measured in hertz and related to period by f=1/T.
A 50 Hz voltage has frequency 50 cycles per second and completes one cycle in 20 ms.
Frequency converter
A frequency converter transfers power between AC systems with different frequencies, allowing systems that cannot be directly synchronized to exchange energy.
A frequency converter links power systems operating at 50 Hz and 60 Hz without forcing equal frequencies.

H

Half-power frequency
A half-power frequency is either frequency at which average resistor power equals half its maximum value for a fixed source voltage.
Current at a half-power frequency is the resonant current divided by √2, not divided by two.
Henry
A henry is the SI unit of inductance, equal to a volt-second per ampere; it connects induced voltage to a current-change rate.
An inductance of one henry produces a 1 V emf magnitude when current changes at 1 A/s.
Hysteresis loss
Hysteresis loss is energy dissipated as magnetic material repeatedly changes magnetization during successive AC cycles in a transformer core.
A transformer can have hysteresis loss even when the secondary winding is not connected to a load.

I

Impedance
Impedance is the ratio of voltage magnitude to current magnitude in sinusoidal steady state, combining resistance with reactive effects.
A series circuit’s impedance can exceed its resistance and lower current at a fixed source voltage.
In phase
Two sinusoids are in phase when corresponding points in their cycles occur together, so they have zero relative phase angle.
Resistor current is in phase with resistor voltage, so their positive peaks occur together.
Inductive reactance
Inductive reactance is the voltage-to-current magnitude ratio of an ideal inductor in sinusoidal steady state, equal to angular frequency times inductance.
Doubling frequency doubles inductive reactance and halves current at unchanged source voltage.
Inductive time constant
The inductive time constant is inductance divided by the resistance of the current path, setting the timescale of an RL exponential.
A 0.20 H coil with a 5.0 Ω series resistor has an inductive time constant of 0.040 s.
Inductive voltage spike
An inductive voltage spike is a large emf produced when an inductor’s current is forced to decrease over a very short time interval.
An inductive voltage spike can make a spark cross the contacts of an opening switch.
Inductor
An inductor is a circuit element designed to store energy in a magnetic field and produce an emf when its current changes.
An ideal inductor in a DC loop eventually has zero voltage drop while still carrying current.
Initial condition
An initial condition specifies a circuit quantity at the start of a time interval and selects the corresponding differential-equation solution.
The initial condition for an unenergized inductor is zero current immediately before and after switching.

L

Lagging current
A lagging current reaches each point in its cycle after the corresponding voltage does, as for an ideal inductor’s quarter-cycle lag.
A net inductive series load draws lagging current even though its current frequency equals the source’s.
LC oscillation
An LC oscillation is a repeated exchange of energy between capacitor and inductor fields, with constant total energy in the ideal loop.
At an LC oscillation’s empty-capacitor instant, current magnitude and magnetic energy are maximal.
Leading current
A leading current reaches each point in its cycle before the corresponding voltage does, as for an ideal capacitor’s quarter-cycle lead.
Leading current is greatest when an ideal capacitor’s voltage passes through zero while increasing.
Leakage flux
Leakage flux is magnetic flux that links one transformer winding without linking the other, behaving as an additional inductive effect.
Leakage flux contributes to a transformer’s load-dependent voltage drop without itself dissipating power.
Line voltage drop
A line voltage drop is the potential difference along the resistance of transmission conductors, equal to current times that resistance.
The line voltage drop across 6 Ω carrying 10 A is 60 V, distinct from the receiving load voltage.
Long solenoid
A long solenoid is a tightly wound cylindrical coil whose length makes its interior magnetic field approximately uniform away from its ends.
The nearly uniform field of a long solenoid makes its flux linkage straightforward to calculate.

M

Magnetic energy density
Magnetic energy density is magnetic energy per unit volume, equal to B squared divided by twice vacuum permeability in vacuum.
A uniform magnetic field lets magnetic energy density be multiplied by volume to obtain total energy.
Magnetic field energy
Magnetic field energy is stored energy associated with a magnetic field; an ideal constant-inductance coil stores one-half L times I squared.
Doubling a coil’s current quadruples its magnetic field energy without changing its inductance.
Mutual inductance
Mutual inductance measures the flux linkage in one coil per unit current in another coil, for a linear magnetic response.
Greater mutual inductance gives a larger sensor emf for the same current-change rate in a nearby coil.

N

Natural angular frequency
The natural angular frequency is the free oscillation rate in radians per second; for an ideal LC loop it is one divided by √(LC).
Increasing capacitance lowers an LC circuit’s natural angular frequency without changing its inductance.
Net reactance
Net reactance is inductive reactance minus capacitive reactance in a series circuit, determining the sign of its reactive voltage.
A negative net reactance makes series current lead the source voltage, indicating capacitive behavior.

O

Oscillation period
An oscillation period is the time required for a circuit’s charge and current to return to the same values and direction of change.
The capacitor first reverses its maximum charge after half an ideal LC oscillation period.
Overdamping
Overdamping is a source-free response above critical resistance that returns from initial capacitor charge without sustained oscillation.
Increasing resistance above the critical value makes an overdamping discharge slower, not faster.

P

Peak value
A peak value is the maximum magnitude of a time-varying quantity, such as the voltage amplitude of a sinusoidal AC source.
A sinusoidal source rated 120 V rms has a peak value near 170 V, not 120 V.
Phase
Phase specifies a sinusoid’s position in its cycle relative to a chosen time or waveform reference, usually as an angle.
A phase difference of 90° corresponds to one-quarter of a cycle between matching waveform points.
Phase angle
The phase angle φ is the voltage lead over current in the convention i = I₀ sin(ωt − φ), positive for a net inductive series load.
With net reactance −30 Ω and resistance 40 Ω, the phase angle is about −36.9°.
Phasor
A phasor is a rotating arrow that represents the magnitude and phase of a sinusoid, allowing same-frequency quantities to be combined as vectors.
A voltage phasor 90° ahead of a reference current represents an ideal inductor’s voltage.
Phasor sum
A phasor sum is the vector resultant of same-frequency sinusoidal quantities, whose projections add at every instant.
A perpendicular 3 V and 4 V phasor sum has magnitude 5 V, even though the scalar sum is 7 V.
Power factor
Power factor is average real power divided by apparent power; for sinusoidal voltage and current it equals the cosine of their phase angle.
A power factor of 0.80 makes real power 80% of the rms voltage–current product.
Power factor correction
Power factor correction reduces reactive supply current, often by adding a parallel capacitor to offset an inductive load’s lagging current.
Power factor correction can reduce supply-wire heating while a motor’s real power remains unchanged.
Primary winding
The primary winding is the transformer coil connected to the input source, which supports the changing flux used to induce secondary voltage.
A transformer’s primary winding draws more load current when its secondary supplies more power.

Q

Quality factor
The quality factor is a dimensionless measure of resonance sharpness, equal to resonant frequency divided by half-power bandwidth.
A higher quality factor lets a tuning circuit distinguish more closely spaced driving frequencies.

R

Reciprocity of mutual inductance
Reciprocity of mutual inductance means that the same inductance links either linear coil’s current to the other coil’s flux linkage.
Reciprocity of mutual inductance lets a calculation start with the coil whose field is easier to find.
Reference phasor
A reference phasor is the arrow chosen as the zero-angle direction when comparing sinusoidal quantities in a phasor diagram.
The common series current is a convenient reference phasor for all three RLC element voltages.
Reflected resistance
Reflected resistance is the resistance a secondary load presents at the primary, equal to the load times the squared primary-to-secondary turns ratio.
A 4:1 primary-to-secondary ratio makes a 5 Ω load have reflected resistance 80 Ω.
Relative permeability
Relative permeability is the ratio of a material’s permeability to vacuum permeability, describing its effect on magnetic response.
A core with high relative permeability can greatly increase a coil’s inductance for the same geometry.
Resonance
Resonance of series current is its maximum steady-state response at fixed source voltage, when inductive and capacitive reactances cancel.
At resonance, the current is in phase with the source even though each reactive voltage can be large.
RL decay
RL decay is the exponential decrease of current when an inductor releases its stored energy through a closed resistive path.
During RL decay, the coil’s magnetic energy supplies the heating in the resistor that still carries the coil’s current.
RL growth
RL growth is the exponential approach of current to its steady value when a DC source energizes a resistive path with inductance.
During RL growth, resistor voltage rises as the inductor’s opposing voltage decreases.
Rms value
An rms value is the square root of the time average of a quantity’s square, giving its heating-equivalent magnitude for a fixed resistor.
For a sinusoidal current, the rms value is about 70.7% of the current’s peak magnitude.

S

Secondary winding
The secondary winding is the transformer coil that provides induced voltage to the load through flux shared with the primary winding.
A secondary winding with fewer turns than the primary supplies a lower voltage in the ideal model.
Self-inductance
Self-inductance is a coil’s own flux linkage per unit current, relating a current change to the emf induced in that same coil.
A coil with greater self-inductance produces more back emf at the same current-change rate.
Steady state
A steady state is a circuit response after switching transients have decayed; under DC, ideal inductor current is then constant.
In a DC steady state, the voltage across an ideal inductor is zero even when current is large.
Step-down transformer
A step-down transformer has fewer secondary than primary turns and lowers voltage while increasing available load current in the ideal model.
A local step-down transformer reduces distribution voltage before power reaches nearby users.
Step-up transformer
A step-up transformer has more secondary than primary turns and raises voltage while reducing load current in the ideal model.
A step-up transformer reduces the line current needed to send a fixed power at high voltage.

T

Toroid
A toroid is a coil wound around a ring-shaped path, with an internal magnetic field that varies inversely with distance from its center.
A wide toroid requires integrating its magnetic field across the radial width of its cross-section.
Transformer
A transformer is a device that transfers energy between windings through changing shared magnetic flux, with voltage set by their turn counts.
A transformer can lower an AC source voltage before it supplies a low-voltage resistive load.
Transmission-line loss
Transmission-line loss is electrical power converted to heat by line resistance, equal to rms current squared times total line resistance.
Reducing current by a factor of five reduces transmission-line loss by a factor of twenty-five.
Turns ratio
The turns ratio compares the numbers of turns in a transformer’s windings and sets the ideal voltage ratio in the same order.
A secondary-to-primary turns ratio of one-fifth produces one-fifth of the primary voltage.

U

Underdamping
Underdamping is a source-free response that oscillates while its amplitude decreases, occurring below the series circuit’s critical resistance.
With underdamping, alternating positive and negative charge peaks shrink as a resistor removes field energy.

V

Voltage magnification
Voltage magnification is the ratio of reactive component voltage to source voltage at resonance, equal to the series circuit’s quality factor.
A quality factor of eight gives voltage magnification of eight across each reactive component at resonance.
Voltage triangle
A voltage triangle is the right-triangle phasor construction relating resistor voltage, net reactive voltage and source voltage in series RLC.
The voltage triangle combines 30 V resistive and 40 V net reactive contributions into a 50 V source.

About this lesson

By StudeliReport a mistake

Make your own Study Materials

Turn your notes, slides and documents into Study Guides, Practice Questions, Flashcards and 6 more tools.

Get Started